bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp electrodes with a resistance of 4-7 MΩ were pulled from thick-wall borosilicate glass using a P-97 horizontal puller (Sutter Instrument Co., USA). They were filled with a solution containing (in mM) ...
-
bioRxiv - Physiology 2019Quote: ... were pulled to low tip resistance (5-7 MΩ) using a Flaming-Brown PC-84 micro-pipette puller (Sutter Instruments, Novato, CA, USA) and back-filled with 500 mM KCl solution ...
-
bioRxiv - Physiology 2021Quote: ... Borosilicate patch pipettes were pulled and polished to resistance of 3-6 MΩ for all experiments using a micropipette puller (model P-97, Sutter Instruments, Novato, CA). Freshly dissociated arterial myocytes were kept in ice-cold Mg2+-PSS before being recorded.
-
A transcriptomic atlas of the mouse cerebellum reveals regional specializations and novel cell typesbioRxiv - Genomics 2020Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Physiology 2022Quote: ... Borosilicate glass pipettes were pulled to a resistance of 2-4 MΩ using a flaming/brown micropipette puller (Model P-1000; Sutter Instrument, Novato, CA). Pipette tips were first dipped into intracellular solution containing 10mM NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... pulled to a resistance between 50 and 70 MΩ when filled with a 1M KCl solution (Sutter P97 Brown Flaming type puller, Sutter Instruments, CA, USA). Electrodes were positioned by microdrives (Luigs-Neumann ...
-
bioRxiv - Neuroscience 2023Quote: ... One to three neurons were recorded per mouse for each experiment using borosilicate glass capillary micropipettes pulled with a 2-5MΩ electrode tip resistance using a Flaming/Brown P97 electrode puller (Sutter Instruments, Novato, CA). Any changes greater than 20% from the initial access resistance throughout the experiment or a membrane capacitance greater than 30 MΩ led to the exclusion of that neuron from analysis ...
-
bioRxiv - Physiology 2023Quote: ... Borosilicate patch pipettes were pulled and polished to resistances of 3-6 MΩ using a micropipette puller (model P-97, Sutter Instruments, Novato, CA).
-
bioRxiv - Biophysics 2024Quote: ... Patch pipettes with a resistance of 2-6 MΩ were fabricated from thin-walled borosilicate glass on a horizontal puller (Model P-1000, Sutter Instruments, Novato, USA). The series resistance was <15 MΩ ...
-
bioRxiv - Biophysics 2023Quote: ... Patch pipettes with a resistance of 2-6 MΩ were fabricated from thin-walled borosilicate glass on a horizontal puller (Model P-1000, Sutter Instruments, Novato, USA). The series resistance was <15 MΩ ...
-
bioRxiv - Physiology 2024Quote: ... Borosilicate patch pipettes were pulled and polished to resistances of 3-6 MΩ for all experiments using a micropipette puller (model P-97, Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp recordings were performed using glass pipette electrodes (resistance 3–7 MΩ) pulled from borosilicate capillaries (BF150-86-10, Sutter Instruments, Novato, CA, USA) using a P-97 pipette puller (Sutter Instruments) ...
-
bioRxiv - Physiology 2020Quote: ... glass microelectrodes were pulled to a tip resistance of 5-7 MΩ on a Flaming-Brown P-1000 Micropipette puller (Sutter Instruments, Novato, CA, USA). TPP was measured with a Duo 773 intracellular/extracellular amplifier (World Precision Instruments ...
-
bioRxiv - Neuroscience 2021Quote: Borosilicate capillary tubes (OD: 1.50mm, ID: 0.86mm, Warner Instruments) were pulled using a horizontal puller (Sutter instruments P-97, resistance of 3-5 MOhm) and filled with artificial Cerebral Spinal Fluid (NaCl ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... Patch pipettes were pulled to a tip resistance of 6-8 MΩ using borosilicate glass capillary tubes with a P-1000 micropipette puller (Sutter Instrument, Novato, CA, USA). Current clamp recording was performed using a Multiclamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording electrodes were pulled from borosilicate glass (4-8 MΩ tip resistance) using a P-97 Flaming/Brown micropipette puller (Sutter Instrument Co., Novato, CA) and filled with intracellular patch electrode solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch clamp recordings were made at room temperature (20-24°C) using patch pipettes with a tip resistance of 2-4 MΩ that were pulled (Flaming-Brown puller, Sutter Instruments, Novato, CA, USA) from borosilicate glass capillaries (BF150-86-10 ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch electrodes with a resistance of 3-5MΩ were guided to neurons with an MPC-200-ROE controller and MP285 mechanical manipulator (Sutter Instruments, Novato, CA, USA). Patch-clamp recordings were collected through a UPC-10 USB dual digital amplifier and Patchmaster NEXT recording software (HEKA Elektronik GmbH ...
-
bioRxiv - Neuroscience 2023Quote: ... The electroporation solution was loaded into a glass needle (Standard Wall Borosilicate Tubing with Filament, BF100-50-10, Sutter Instruments, resistance 10-30 MΩ) and placed onto the headstage of an electroporation device (Axoporator ...
-
bioRxiv - Physiology 2023Quote: ... pulled to form low resistance tips (approximately 5–7 MΩ) using a model P-87 Flaming/Brown micropipette puller (Sutter Instruments, Novato, CA, USA). These microelectrodes were backfilled with 500 mM KCl ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell electrophysiological recordings were conducted using borosilicate glass electrodes having an internal resistance of 3-5 MΩ (Sutter Instrument Company, Novato, California, USA). The electrode solution contained (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: Labeled vagal neurons were approached by glass pipettes (2–4 MΩ resistance) using a micromanipulator (MP-285/ MPC-200, Sutter Instruments, Novato, CA, USA) attached to a head stage (CV203BU ...
-
bioRxiv - Neuroscience 2022Quote: ... The recordings were obtained using borosilicate glass pipettes (resistance 4–10 MΩ) prepared using a 2-stage vertical pipette puller (P-1000, Sutter Instrument, or PP-83, Narishige). The pipettes were filled with a solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell voltage- and current-clamp recordings were obtained from mouse DRG neurons or transiently transfected HEK293 cells with borosilicate glass patch-pipettes (Sutter Instruments, 4-8 MΩ resistance) and were performed simultaneously with temperature recordings ...
-
bioRxiv - Neuroscience 2020Quote: ... was recorded via a heat-pulled borosilicate glass electrode containing an Ag/AgCl filament and filled with aCSF (electrode tip Ø, 2–3 μm; inner Ø, 0.86 mm; outer Ø, 1.5 mm; Sutter Instrument; resistance 1.5–2.0 MΩ). The electrode was inserted under the glass coverslip ∼50 μm into the cerebral cortex ...
-
bioRxiv - Neuroscience 2022Quote: ... Whole-cell recordings were obtained from fluorescently-labelled DRN 5-HT and SOM neurons and unlabeled mPFC L5 pyramidal neurons using glass electrodes (Sutter Instruments; tip resistance 4 to 6 MOhm). For most experiments ...
-
bioRxiv - Microbiology 2020Quote: ... This vector and its product was targeted as the main contamination tracer in this study via PCR of vector sequences and macro-photography of the mNeonGreen protein fluorescence under 470 nm wavelength using a xenon arc lamp (Sutter Instruments; California, USA).
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Approximately 1-3 µL of protein solution was loaded into glass emitters that were made in-house using borosilicate capillaries and a micropipette puller (Sutter Instruments Model P-97, Novato, CA). A platinum wire was inserted into the solution and approximately 0.5-1 kV was applied to the wire to generate ions ...
-
bioRxiv - Developmental Biology 2024Quote: ... and 1 mm (BF200-100-10, SUTTER INSTRUMENTS) for 70 days old coricOs.
-
bioRxiv - Cell Biology 2020Quote: Solid borosilicate glass rods 1 mm in diameter (Sutter Instruments) were pulled into a needlepoint with a Brown-Flaming type micropipette puller (Sutter P-87) ...
-
bioRxiv - Neuroscience 2024Quote: ... standard-wall (1 mm outer diameter) borosilicate capillaries (Sutter Instrument) were pulled to resistances between 5–16 MΩ using a micropipette puller (Flaming/Brown ...
-
bioRxiv - Neuroscience 2021Quote: ... 0.5-1 μL per point) with sharpened glass pipettes (Sutter Instrument), self-made to have a bevel of 35° and an opening of 20-μm diameter at the tip (64) ...
-
bioRxiv - Cell Biology 2020Quote: Glass capillaries (0.75mm inner diameter, 1 mm outer diameter; Sutter Instrument) were forged into glass needles by pulling them on a vertical pipette puller (Narishige PC-10) ...
-
bioRxiv - Cancer Biology 2023Quote: Borosilicate glass capillaries (O.D.: 1 mm, I.D.: 0,75 mm, Sutter Instrument) were pulled using glass micropipette puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2019Quote: ... glass microelectrodes with 1-micron tips were pulled (Sutter Instruments, Borosilicate Glass with filament) and filled with 2M NaCl (resistance 1-2 MΩ) ...
-
bioRxiv - Neuroscience 2022Quote: ... glass capillary tubes (GD-1; Narishige) were pulled using a micropipette puller (Sutter Instruments). Embryos were injected into the lateral ventricle with 1 microliter of DNA solution (expression plasmids other than pCAG-tTA2s ...
-
bioRxiv - Biochemistry 2021Quote: ... with an emitter tip pulled to approximately 1 µm using a laser puller (Sutter Instruments). Peptides were loaded on-column at a flow-rate of 400nL/min for 30 minutes and then eluted over 120 min at a flow-rate of 300 nl/minute with a gradient of 2-30% acetonitrile in 0.1% formic acid ...
-
bioRxiv - Biochemistry 2021Quote: ... Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm were purchased from Sutter Instruments.
-
bioRxiv - Biochemistry 2021Quote: ... Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm were purchased from Sutter Instruments, Germany.
-
bioRxiv - Neuroscience 2022Quote: ... Glass micropipettes (O.D. 1 mm, I.D. 0.5 mm Sutter Instruments, cat no. BF100-50-10) pulled by using a P1000 pipette puller (Shutter Instruments ...
-
bioRxiv - Cell Biology 2022Quote: ... with 1 mm inner diameters using a Flaming-Brown Micropipette Puller (Sutter Instrument, Novato, CA). Pulled tips were cut with ceramic tile to final inner diameter 50-100 µm ...
-
bioRxiv - Neuroscience 2021Quote: ... Germany. Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm) were purchased from Sutter Instruments. Water used in the experiments was deionised in house using a Millipore column and had a resistivity of 18MΩ.
-
bioRxiv - Biophysics 2022Quote: Micropipettes made of borosilicate capillaries (ID =0.78 mm, OD = 1 mm, B100-75-15, Sutter Instrument) were formed using a puller (P-1000 ...
-
bioRxiv - Developmental Biology 2022Quote: ... Dissection was carried out by means of pulled borosilicate rods (1 mm of diameter, Sutter instrument) pulled using a P97 filament-based pipette puller (Sutter instrument ...
-
bioRxiv - Neuroscience 2022Quote: ... was slowly inserted (0.1 mm per 1 minute) using motorized micromanipulator (MP-225; Sutter Instrument Co.) into the cerebellum with the tip reaching depth of 3-5.5 mm below the brain surface ...
-
bioRxiv - Neuroscience 2023Quote: ... Slices were maintained at 24±1 °C using a dual TC344B temperature control system (Sutter Instruments). S1HL slices were continuously perfused with oxygenated (95%O2/ 5%CO2 ...
-
bioRxiv - Developmental Biology 2021Quote: The glass capillary tubing (OD=1 mm, ID=0.58 mm, length=7.5 cm) was pulled (Sutter instruments Co. ...
-
bioRxiv - Biochemistry 2021Quote: ... monosodium phosphate (NaH2PO4). Quartz capillaries (o.d. 1 mm, i.d. 0.5mm, length 7.5 cm) were purchased from Sutter Instruments. Deionised (Millipore ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch electrodes (2–4 MΩ) were pulled from borosilicate capillary glass of external diameter 1 mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...
-
bioRxiv - Neuroscience 2021Quote: Patch electrodes (2–3□MΩ) were pulled from borosilicate capillary glass of external diameter 1□mm (Sutter Instruments) using a Flaming/Brown micropipette puller (model P-2000 ...