Labshake search
Citations for Sutter Instruments :
51 - 100 of 186 citations for Rat Oxidation resistance protein 1 Oxr1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2020Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Electrophysiological recordings from neurons were obtained in Tyrode’s medium ([mM] 150 NaCl ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (resistance, 8–10 MΩ) were pulled from 1.5 mm thin-walled borosilicate glass (Sutter Instruments, Novato, CA) on a horizontal puller (model P-97 ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (resistance, 8-10 MΩ) were pulled from 1.5 mm thin-walled borosilicate glass (Sutter Instruments, Novato, CA) on a horizontal puller (model P-97 ...
-
bioRxiv - Neuroscience 2022Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Pipettes were filled using standard intracellular solution (in mM ...
-
bioRxiv - Neuroscience 2022Quote: ... recording pipettes with a resistance of 4-6 MΩ were obtained using the SU-P97 puller (Sutter Instrument Company). Recordings were carried out at room temperature (24-25°C) ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes with resistance ranging from 6 to 10 MΩ were fabricated from borosilicate glass (Sutter Instruments, Novato, CA) on a 4-step micropipette P-90puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate pipettes of 5 – 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter instruments). All recordings were done in current clamp with an intracellular solution containing 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2021Quote: ... Electrodes with resistance (RE) of 20–30 MΩ were made from borosilicate glass pipettes (BF100-58-10; Sutter Instruments) using a laser pipette puller (P-2000 ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Patch electrodes with resistances of 2-5 MΩ were pulled with a P-97 micropipette puller (Sutter Instruments, USA). The conventional whole-cell recordings were obtained by manual suction for hERG ...
-
bioRxiv - Neuroscience 2021Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). For hippocampal neuron cultures ...
-
bioRxiv - Neuroscience 2022Quote: ... Micropipettes were made with borosilicate glass pulled to a resistance of 3.5 – 5.5 MΩ on a Flaming/Brown P-1000 micropipette puller (Sutter Instruments) and filled with the same ACSF ...
-
bioRxiv - Biophysics 2023Quote: ... CT) to resistances of 1.5 MΩ to 3 MΩ using a micropipette puller (P-1000, Sutter Instruments, Novato, CA) and fire-polished ...
-
bioRxiv - Neuroscience 2023Quote: ... Electrodes with resistance (RE) of 15-25 MΩ were made from borosilicate glass pipettes (BF100-58-10; Sutter Instruments) using a laser pipette puller (P-2000 ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (6–7 MΩ tip resistance, borosilicate glass, outer diameter 1.5 mm, inner diameter 0.86 mm, Sutter Instruments) were filled with the following internal solution (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass (3-7 MΩ resistance) recording pipettes were pulled using a P-1000 Flaming/ Brown micropipette puller (Sutter Instruments). Recordings were performed using an Axopatch 200B amplifier (Molecular Devices) ...
-
bioRxiv - Neuroscience 2020Quote: ... World Precision) to obtain pipette resistance ranging from 5 – 8 MΩ using next generation micropipette puller (P-1000, Sutter Instrument). External solution is consist of 140 mM NaCl ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (resistance 5-10 MΩ, pulled using a P-87 Flaming/Brown micropipette puller, Sutter Instruments, Novato, CA, USA) were filled with low chloride internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... to a tip resistance of 3-4MOhms with a P-97 Flaming/Brown type micropipette puller (Sutter Instruments, Atlanta, Georgia).
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with a tip resistance of 8-12 MΩ were made of borosilicate capillaries (Sutter Instruments, Novato, CA, USA) and filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... The patch pipettes with resistance 3-5 MΩ were pulled by the pipette puller (Sutter Instrument Co., Model P-97). To measure spontaneous action potential (sAP) ...
-
bioRxiv - Neuroscience 2023Quote: Pipettes with resistance of 3.5-6 MΩ were fabricated from borosilicate filamented capillaries using the P-97 micropipette puller (Sutter Instrument). The pipettes were filled with an internal solution composed of 8mM NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (resistance 5-10 MΩ, pulled on a P-87 Flaming/Brown micropipette puller, Sutter Instruments, Novato, CA, USA) were filled with low chloride internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass micropipettes with a tip resistance of ∼4-5 MΩ were prepared using a P-1000 puller (Sutter Instruments) and then filled with an intracellular recording solution containing (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were pulled from borosilicate glass (Flaming-Brown puller, Sutter Instruments, P-97, tip resistance of 5–10 MΩ) and filled with pipette solution consisting of 120 mM potassium gluconate ...
-
bioRxiv - Cancer Biology 2024Quote: ... Recording pipettes were generated from borosilicate glass (Flaming-Brown puller, Sutter Instruments, P-97, tip resistance of 5–10 MΩ) and were filled with pipette solution consisting of 120 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipette of 5-8 MΩ tip resistance were fabricated from borosilicate glass by using a microelectrode puller (Sutter Instruments). The initial access resistance was 18.2±0.5 MΩ for current-clamp recordings (n=21 ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes with a tip resistance of 4–7MΩ were pulled with a flaming-Brown puller P-97 (Sutter Instruments) from borosilicate glass capillaries (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... to a resistance of 2–4 MΩ using a horizontal puller (P-97 or P-1000; Sutter Instruments, Novato, CA). In most experiments ...
-
bioRxiv - Neuroscience 2020Quote: ... All whole-cell experiments were recorded using borosilicate glass pipettes with resistances in the 3 – 5 MΩ range and were pulled on a Flaming-Brown micropipette puller (P-1000, Sutter Instruments). Whole-cell voltage-clamp electrophysiology recordings were made from spiny projection neurons (SPNs ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were made from borosilicate glass with a Flaming-Brown puller (P-97, Sutter Instruments; tip resistance 5-10 MΩ). The pipette solution contained (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass pipettes with a tip resistance of 3–4 MΩ (G150F-4, Warner Instruments) were pulled on a P-97 Flaming-Brown micropipette puller (Sutter Instruments) and filled with an internal solution containing ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell patch clamp recordings were obtained using thin-walled borosilicate glass microelectrodes (Warner) pulled to a tip resistance of 3-5 MΩ pulled using a P-97 Flaming/Brown Micropipette Puller (Sutter Instrument). Electrodes were filled with an intracellular recording solution containing (in mM) ...
-
bioRxiv - Cell Biology 2021Quote: ... and the resistance of each microelectrode was set to zero and then secured in an MPC-325 micromanipulator (Sutter Instrument Company) within an environmental chamber maintained at 37°C and 10% CO2 ...
-
bioRxiv - Neuroscience 2022Quote: ... 1.5 mm diameter borosilicate pipettes with tip resistances of 2-5 MΩ were pulled using a P-1000 micropipette puller (Sutter Instruments). Pipettes were filled intracellular solution containing (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes with an open tip resistance of 4-6 MΩ were prepared from borosilicate glass (Sutter Instrument BF150-86-10) using a Flaming/Brown pipette puller (Sutter Instrument SU-P97) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch electrodes with a 2–3 M tip resistance were fabricated using a three-stage custom program on a Flaming-Brown micropipette puller (P-97, Sutter Instruments) and filled with solution containing the following (in mM) ...
-
bioRxiv - Developmental Biology 2023Quote: ... The fine recording (borosilicate) electrodes with a resistance of 20-25 MΩ were pulled using a P-97 micropipette puller (Sutter Instruments) and back-filled with 3M KCl ...
-
bioRxiv - Neuroscience 2024Quote: ... Warner Instruments) were pulled to have resistances of 3-7 MΩ using a Flaming-Brown pipette puller (model P-97; Sutter Instruments). The pipette tip was initially filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell current-and voltage-clamp recordings were performed in a recording chamber at room temperature using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (Hilgenberg) of 6 - 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter Instruments). The intracellular solution contained 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2020Quote: ... whole-cell patch-clamp recordings were obtained at the soma under 60x magnification in BGMT neurons from control and 6-OHDA-lesioned mice with glass pipettes (at resistances 4-8 MΩ) pulled from 1.5 mm OD borosilicate glass on a Sutter P-97 puller (Sutter Instruments, Novato, CA).
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes were fabricated from 1.7 mm capillary glass and fire-polished to a resistance of 0.9-1.3 MΩ using a Sutter P-97 puller (Sutter Instrument Company, Novato, CA). All voltage protocols were started 5 minutes after obtaining a gigaΩ seal and entering the whole-cell configuration ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell configuration in both voltage- and current-clamp modes (VC and CC, respectively) was obtained with borosilicate glass pipettes produced with horizontal puller (resistance ∼7 MΩ; Sutter Instruments, USA) and suction applied by an Ez-gSEAL100B Pressure Controller (Neo Biosystem ...
-
bioRxiv - Physiology 2021Quote: ... Low resistance electrodes (5-10 megaohms) were fashioned from cleaned capillaries using the P-87 Faming/Brown micropipette puller (Sutter Instrument Co.). The electrodes were silanized with dichlorodimethylsilane (440272-100ml ...
-
bioRxiv - Cancer Biology 2021Quote: ... non-filamented borosilicate micropipettes were pulled to a resistance of 5-10 MΩ (P-97 micropipette puller, Sutter Instruments, Novato, CA, USA) and coated with a hydrophobic layer of N,N-dimethyltrimethylsilylamine (Sigma Aldrich ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4-6 MΩ resistance) were pulled from borosilicate capillaries using a P-97 Flaming/Brown micropipette puller (Sutter Instrument Co.). For recording sEPSCs ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch electrodes (resistance of 4-7 MΩ) were pulled on a P-87 or P-1000 pipette puller (Sutter Instruments Co., USA). Pyramidal neurons and PV+ interneurons from L2/3 of the somatosensory or motor cortex were recorded with the whole-cell patch clamp configuration in voltage or current-clamp mode ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were then conducted at RT using pipettes with resistances typically ranging from 6-8 MΩ (P-2000, Sutter Instruments, USA). The pipette solution consisted of the following concentrations (in mM) ...
-
bioRxiv - Bioengineering 2021Quote: Borosilicate glass pipettes were pulled to a resistance of 2-4 MΩ using a flaming/brown micropipette puller (Model P-1000; Sutter Instrument, Novato, CA). The pipettes were filled with intracellular solution containing 10 mM NaCl ...
-
bioRxiv - Neuroscience 2021Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ~4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...