Labshake search
Citations for Sutter Instruments :
101 - 150 of 217 citations for 5 tert Butyl 3 isocyanatoisoxazole since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... were pulled to resistances of 5 - 8 MΩ (P-2000; Sutter Instruments, Novato CA). The standard pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 5 or 10 µL microsyringe (Hamilton) equipped with a microinjector (Sutter Instrument) and controller (World Precision Instruments) ...
-
bioRxiv - Molecular Biology 2024Quote: ... with a Flaming-Brown P-97 puller (Sutter Instruments; tip resistance 5–8 MΩ). The pipette solution contained (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Glass pipettes (5-000-2005, Drummond) were pulled (Model P-97, Sutter Instrument Co) and further broken to obtain a tip of -10-15 µm inner diameter and further beveled to create a sharp tip and avoid cortical damage during insertion.Callosal projections tracings ...
-
bioRxiv - Cell Biology 2020Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Electrophysiological recordings from neurons were obtained in Tyrode’s medium ([mM] 150 NaCl ...
-
bioRxiv - Physiology 2021Quote: ... Recording electrodes (3–4 MΩ) were pulled on a model P-87 micropipette puller (Sutter Instruments, Novado, CA, USA) and polished using a MF-830 MicroForge (Narishige Scientific Instruments Laboratories ...
-
bioRxiv - Neuroscience 2022Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). Pipettes were filled using standard intracellular solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (3–6 MΩ) were manufactured from filamented borosilicate glass capillaries (Sutter Instruments, Novato, CA, BF100-58-10) and filled with an intracellular solution containing (in mM) ...
-
bioRxiv - Cell Biology 2022Quote: ... were used to pull patch pipettes (3 MΩ) on a horizontal Flaming/Brown micropipette puller (P-1000, Sutter Instruments) and polished by microforge (Narishige MF-830 ...
-
bioRxiv - Neuroscience 2021Quote: ... with resistances ranging from 3–7 MΩ were pulled using a laser micropipette puller (Sutter Instrument Model P-2000). For hippocampal neuron cultures ...
-
bioRxiv - Biophysics 2024Quote: ... CT) to resistances of 1.5 MΩ to 3 MΩ using a micropipette puller (P-1000, Sutter Instruments, Novato, CA) and fire-polished ...
-
bioRxiv - Biophysics 2024Quote: ... Coarse microelectrodes were fabricated from borosilicate capillaries (TW120F-3, World Precision Instrument) with a pipette puller (P97, Sutter Instrument); their resistance ranged from 0.8 to 1.5 MΩ when filled with 3-M KCl and immersed in the same solution ...
-
bioRxiv - Neuroscience 2020Quote: ... at approximately 5 mm away from the tip) using a laser electrode puller (Sutter Instrument, model P-2000 ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (3.5-5 MΩ) were pulled with P-97 horizontal micropipette puller (Sutter Instruments) filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass (3-7 MΩ resistance) recording pipettes were pulled using a P-1000 Flaming/ Brown micropipette puller (Sutter Instruments). Recordings were performed using an Axopatch 200B amplifier (Molecular Devices) ...
-
bioRxiv - Microbiology 2020Quote: ... were used to pull patch pipettes (3–4 MΩ) on a horizontal Flaming/Brown micropipette puller (P-97, Sutter Instruments) and then were backfilled with intracellular solution ...
-
bioRxiv - Cell Biology 2021Quote: ... with motorized stage controller (MS-2000, ASI, Eugene, OR) and filter wheel controller (Lambda 10-3, Sutter Instrument, Novato, CA). The sample was illuminated with a LED light source (pE-300 ...
-
bioRxiv - Neuroscience 2021Quote: ... to a tip resistance of 3-4MOhms with a P-97 Flaming/Brown type micropipette puller (Sutter Instruments, Atlanta, Georgia).
-
bioRxiv - Neuroscience 2022Quote: ... Glass capillaries (G150F-3, Warner Instruments, Hamden) were pulled by a micropipette puller (Model P-87, SUTTER INSTRUMENT, Novato, USA) and their tips were mechanically crushed by approximately 2 mm ...
-
bioRxiv - Cell Biology 2024Quote: ... and emission light was separated using filters in a filter wheel controlled by a Lambda 10-3 unit (Sutter Instruments). GFP/Alexa488 (530/50 ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes of 3-6 MΩ resistance were made using borosilicate glass capillaries using a P-1000 puller (Sutter Instruments) and filled with internal solution ...
-
bioRxiv - Biophysics 2024Quote: ... Patch pipettes (∼3 MΟ resistance) were fabricated from 1.5-mm thick wall borosilicate glass capillaries (P1000, Sutter Instruments, Novato, CA). Electrophysiological parameters of each patched cell were monitored with an amplifier (AxoPatch200b ...
-
bioRxiv - Neuroscience 2021Quote: ... The borosilicate patch pipettes (2–5 MΩ) were pulled with a Flaming-Brown puller (Sutter Instruments) and contained the following (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: Fluorescence imaging was performed with a Lambda DG-5 wavelength changer (Sutter Instruments, Novato, CA, USA) and a Chroma 79001 filter set (340 nm and 380 nm band-pass filters for excitation ...
-
bioRxiv - Neuroscience 2024Quote: ... A Lambda XL Xenon lamp (Sutter) with 5 mm liquid light guide (Sutter Instrument, Novato, CA) was used to illuminate samples ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrodes were pulled to tip resistances of 5-8 MΩ using a multistage puller (Sutter Instruments) and filled with intracellular solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Taste bud cells were illuminated with Lambda DG-5 illumination system (Sutter Instruments, Novato, CA, USA), and imaging was performed using an acA720 camera (Basler ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass pipettes with a tip resistance of 3–4 MΩ (G150F-4, Warner Instruments) were pulled on a P-97 Flaming-Brown micropipette puller (Sutter Instruments) and filled with an internal solution containing ...
-
bioRxiv - Cell Biology 2021Quote: ... and emission light was separated using the following filters fitted into a filter wheel controlled by a Lambda 10-3 unit (Sutter Instruments): GFP/Alexa488 (530/50 ...
-
bioRxiv - Plant Biology 2021Quote: ... Fura-2 fluorescence imaging was performed using the Zeiss Axiovert 200 microscope equipped with two filter wheels (Lambda 10-3; Sutter Instruments) and a CMOS camera (Prime sCMOS ...
-
bioRxiv - Biophysics 2020Quote: ... A Lambda 10-3 filter switcher and shutter controller was used with a Lambda LB-LS/30 Xenon arc lamp (Sutter Instruments). Images were acquired at 1 frame/15 s for 5 m at low glucose and 1 frame/15 s for 25 m after stimulation high glucose using a Andor CCD camera ...
-
bioRxiv - Cancer Biology 2020Quote: ... and triple-band laser emission filter ZET405/488/561m (Chroma), mounted in the metal cube (Chroma, 91032) together with emission filter wheel Lambda 10-3 (Sutter instruments) with ET460/50m ...
-
bioRxiv - Neuroscience 2020Quote: Gross manipulation of the pipette is performed under manual control of the Sutter MP 285 3-axis patch manipulators (Sutter Instruments). Axial movements of the pipette are performed by the one-axis motorized translation stage (PT1-Z8 ...
-
bioRxiv - Neuroscience 2023Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼1-3-MΩ resistance for PCs and ∼3-6-MΩ resistance for MLIs pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument). Slice recordings with PC leak currents greater than 500 pA were rejected ...
-
bioRxiv - Neuroscience 2023Quote: ... and monopolar stimulator pipettes (3 – 4 MΩ) were obtained from borosilicate glass capillaries with a horizontal pipette puller (P-97, Sutter Instruments). The internal pipette solution contained the following (in mM) ...
-
bioRxiv - Cell Biology 2022Quote: ... 2D triple-color imaging were performed using an Olympus IX81 microscope equipped with a high-speed filter changer (Lambda 10-3; Sutter Instruments) that can change filter sets within 40 ms ...
-
Dietary potassium and cold acclimation additively increase cold tolerance in Drosophila melanogasterbioRxiv - Physiology 2024Quote: ... and pulled to a ∼ 1-3 mm tip on a Flaming-Brown micropipette puller (P-1000, Sutter Instruments, Novato, CA, USA). After pulling ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes made of borosilicate glass (3-7 MΩ resistance) were pulled using a P-1000 Flaming/Brown micropipette puller (Sutter Instruments). Recordings were performed using a Multiclamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Neuroscience 2024Quote: ... infused with Nanoject (3-000-207, Drummond) using glass injectors (3-000-203-G/X, Drummond) pulled on a horizontal pipette puller (P-1000 Sutter Instrument). After infusion the injector was left for 3 to 5 min then withdrawn ...
-
bioRxiv - Neuroscience 2024Quote: ... equipped with infrared-oblique illumination and patched with pipettes of 3 to 6 MΩ (#30-0060, Warner Instruments) made with a laser puller (P-2000, Sutter Instruments). The pipette solution contained (in mM) ...
-
bioRxiv - Biochemistry 2024Quote: The glass capillary needles for injections were prepared using glass capillaries (3.5” Drummond #3-000-203-G/X) and a micropipette puller (Sutter Instrument Company). After backfilling the glass capillary needles with mineral oil (Sigma BioReagent ...
-
bioRxiv - Biophysics 2024Quote: ... Patch pipettes were pulled from G150F borosilicate capillaries (Warner Instruments) to a resistance of 2-3 MΩ using a P-97 puller (Sutter Instrument) and heat-polished using a Microforge-MF2 (Narishige) ...
-
bioRxiv - Neuroscience 2020Quote: ... were pulled to tip resistances of 5-8 M Ώ using a multi-stage puller (Sutter Instruments) and were filled with K-gluconate based intracellular solution ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes of 5–10 MΩ were pulled with a P-97 Flaming/Brown puller (Sutter Instruments) from borosilicate glass capillaries and the intracellular solution used contained (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (5-6 MΩ) were pulled from borosilicate glass capillaries (GBF-150-117-10; Sutter Instruments) with a micropipette horizontal puller (P-97 ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were pulled to tip resistances of 5-8 MΩ using a multistage puller (Sutter Instruments) and were filled with intracellular solution ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (5-6 MΩ) were pulled from borosilicate glass capillaries (GBF-150-117-10; Sutter Instruments) with a micropipette horizontal puller (P-97 ...
-
bioRxiv - Neuroscience 2024Quote: ... For stereotaxic injections, glass pipettes (5-000-2005, Drummond) were pulled (Model P-97, Sutter Instrument Co) and broken to obtain a tip of ∼10-15µm inner diameter ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrodes were pulled to tip resistances of 5–12 MΩ using a multi-stage puller (Sutter Instruments) and were filled with intracellular solution which contained (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... POMC neurons in the arcuate nucleus were visually identified by GFP expression and subjected to whole cell patch clamp using 3-6 MΩ borosilicate glass micropipettes (Sutter Instruments, UK) filled with potassium gluconate internal containing (in mM) ...