Labshake search
Citations for Sutter Instruments :
701 - 750 of 770 citations for glass bottom plate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Both stimulation and recording electrodes were placed within area CA1 and pulled glass electrodes (Catalog # B150-110-10, Sutter Instruments, Novato, CA) filled with aCSF (2-5MΩ resistance ...
-
bioRxiv - Neuroscience 2024Quote: ... and interneurons were impaled and recorded in-vivo using sharp intracellular glass electrodes pulled using a micropipette puller (P97, Sutter instruments, CA). The electrode tip had a resistance of 5-15 MΩ when filled with electrolyte solution (1M K ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (9-12 MΩ) were fashioned from borosilicate glass capillaries (without filament) using a Flaming-Brown puller (Sutter Instrument #P-97) and further polished with a MF200 microforge (WPI ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (4-6 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) with a micropipette puller (P-87, Sutter Instruments Co.) and filled with a potassium gluconate-based intracellular solution containing (in mM) ...
-
bioRxiv - Biophysics 2024Quote: Delivery pipettes were fabricated from 1.5-mm thick wall borosilicate glass capillaries using a pipette puller (P-80/PC, Sutter Instruments, Novato, CA). Delivery pipette inner diameters ranged from 10 to 20 µm ...
-
bioRxiv - Cell Biology 2024Quote: ... Patch pipettes were fabricated from borosilicate glass capillaries (World Precision Instr., Inc., Sarasota, FL) on horizontal puller (Sutter Instruments Co., Novato, CA) and had a resistance in the range of 7-10 MΩ ...
-
bioRxiv - Cell Biology 2024Quote: Fertilized Casper zebrafish embryos were collected and injected at the one-cell stage into the cytoplasm with a laser-pulled borosilicate glass microneedle (H=370, FIL=5, VEL=50, DEL=245, PUL=140; P-2000 Sutter Instrument CO.) and a Nanoject IITM microinjector (Drummond Scientific ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were obtained using glass microelectrodes (3–5 MΩ) pulled using a Narishige PC-10 puller (Narishige Japan, Tokyo Japan) or Sutter P-1000 Glass puller (Sutter Instruments, Novato, CA) and were low-pass filtered at 3 kHz ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes (4-8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) with a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a potassium gluconate-based intracellular solution containing either (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ~4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Neuroscience 2020Quote: Single-unit extracellular spikes were recorded with micropipettes which were pulled from quartz glass tubes (Sutter Instrument, Novato, CA; product QF100-50-10) using a laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp electrodes with a resistance of 4-7 MΩ were pulled from thick-wall borosilicate glass using a P-97 horizontal puller (Sutter Instrument Co., USA). They were filled with a solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes (4–8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) using a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a KGlu based intra-pipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch clamp recordings were performed using micropipettes pulled from a borosilicate glass capillary tube using a Flaming/Brown electrode puller (Sutter P-97; Sutter Instruments, Novato, California). Electrode tip resistance was between 3 and 6 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: Whole-cell patch-clamp electrodes were produced from borosilicate glass capillaries (outer diameter 2 mm, inner diameter 1 mm, Hilgenberg, Germany) using a horizontal puller (P-97, Sutter Instruments, CA, USA) and filled with an intracellular solution consisting of (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes were prepared from borosilicate glass capillaries (G150F-3; Warner Instruments, Hamden, CT) using a P-1000 micropipette puller (Sutter Instruments, Novato, CA) and subsequently fire polished ...
-
bioRxiv - Developmental Biology 2021Quote: ... Pipettes with 2.0-4.0 MOhm resistance in symmetric 150 mM KCl buffer were pulled from Kimble Chase 2502 soda lime glass with a Sutter P-86 puller (Sutter Instruments, Novato, CA).
-
A transcriptomic atlas of the mouse cerebellum reveals regional specializations and novel cell typesbioRxiv - Genomics 2020Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼4 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Multiclamp 700B amplifier (Axon Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... One to three neurons were recorded per mouse for each experiment using borosilicate glass capillary micropipettes pulled with a 2-5MΩ electrode tip resistance using a Flaming/Brown P97 electrode puller (Sutter Instruments, Novato, CA). Any changes greater than 20% from the initial access resistance throughout the experiment or a membrane capacitance greater than 30 MΩ led to the exclusion of that neuron from analysis ...
-
bioRxiv - Neuroscience 2023Quote: ... pulled from 1 mm diameter thin-walled quartz glass tubing on a Sutter P-2000 micropipette puller (Sutter Instrument Novato, CA 94949, USA). Signals were amplified with a recording bandwidth of DC - 100 kHz using a custom preamplifier (Brighton lab ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were performed using borosilicate glass pipettes of 3–5 MΩ pulled with a micropipette puller (P-1000; Sutter Instrument, Novato, CA). For voltage-clamp recording ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected into the midbrain ventricle together with tol2 mRNA (20ng/μl) and Phenol-red (∼0.025%) at 5-8nL using a micro glass needle (0.58mm inside diameter, Sutter Instrument, Germany, BF100-58-15) pulled using a micropipette puller (Model P-87 Sutter Instrument ...
-
bioRxiv - Biochemistry 2024Quote: ... pulled from 1.5 mm borosilicate glass capillaries (Zeitz-Instruments GmbH, München, Germany) using micropipette puller P 97 (Sutter Instruments, Novato, CA, United States). The tips were polished for 2–4 MΩ pipette resistance in the bath solution ...
-
bioRxiv - Biophysics 2024Quote: ... Patch pipettes with a resistance of 2-6 MΩ were fabricated from thin-walled borosilicate glass on a horizontal puller (Model P-1000, Sutter Instruments, Novato, USA). The series resistance was <15 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal CPA (0.1 mg/ml) and SR101 (0.1 mg/ml) application was performed by means of borosilicate glass pipettes (BF150-86-10, Sutter Instrument, Novato, CA, US) mounted on 3-axis micromanipulator units (LN Mini 25 ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings were made in voltage-clamp configuration (holding potential -40 mV) with a borosilicate glass pipette (Sutter Instrument Company, Novato, CA) filled with intracellular solution containing (in mM) ...
-
bioRxiv - Cancer Biology 2022Quote: ... Xenotransplantation was performed using injection capillaries (glass capillaries GB100T-8P, without filament, Science Products GmbH, Germany) pulled with a needle puller (P-97, Sutter Instruments, Novato, USA) mounted on a micromanipulator (M3301R ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes were prepared from borosilicate glass capillaries (G150F-3; Warner Instruments, Hamden, CT) using a P-1000 micropipette puller (Sutter Instruments, Novato, CA) and were subsequently fire-polished ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes (4–8 MΩ) were pulled from thin wall borosilicate glass (G150TF-3, Warner Instruments) using a micropipette puller (P-87, Sutter Instruments, Novato, CA) and filled with a potassium gluconate (KGlu)-based intrapipette solution containing (in mM) ...
-
bioRxiv - Developmental Biology 2023Quote: ... Both the holding pipette and pulled needle were custom-made from glass capillaries (Warner Instrument, GC100T-15) using a micropipette puller (Sutter Instrument, P-1000) and a microforge (Narishige ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes with electrode resistance of 4-9 MΩ were pulled with Zeitz puller (Werner Zeitz, Martinsried, Germany) from borosilicate thick glass (GC150F, Sutter Instruments, Novato, CA) and with an intracellular patch pipette solution containing 120 mM K-gluconate ...
-
bioRxiv - Neuroscience 2024Quote: ... Specialized glass pipettes (tip diameter: 10– 20 μm) for AAV microinjections were expertly crafted using a P-97 Micropipette Puller (Sutter glass pipettes, Sutter Instrument Company, USA). These microinjection pipettes ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes with a tip resistance of 3–6 MΩ were prepared using a P-97 puller (Sutter Instruments, Novato, CA, USA) and filled with intracellular recording solution (ICS ...
-
bioRxiv - Neuroscience 2024Quote: Voltage-clamp recordings of DA neurons were conducted with patch pipettes from thick walled borosilicate glass tubing (outer diameter: 2 mm, inner diameter: 1 mm, Hilgenberg, Germany) with a horizontal puller (P-97, Sutter Instruments, Novato, USA). Pipettes were first filled with a potassium gluconate-based internal solution (∼1 mm from the tip ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes with electrode resistance of 3-7 MΩ were made fresh with a Zeitz puller (Werner Zeitz, Martinsried, Germany) from borosilicate thick glass (GC150F, Sutter Instruments, Novato, CA). Intracellular patch-pipette solution was the same as previously described (Zurek et al. ...
-
bioRxiv - Neuroscience 2024Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼3 MΩ resistance pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument, Novato, CA). Electrophysiology data was acquired using a Sutter dPatch amplifier (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2024Quote: ... ≈ 1012 genomic copies per mL) were injected through a pulled glass pipette (pulled with a P-97 model Sutter Instrument Co. pipette puller) using a nanoinjector (World Precision Instruments ...
-
bioRxiv - Neuroscience 2024Quote: Focal electrical field evoked stimulation was performed via a theta-glass (borosilicate; Hilgenberg) pipette pulled using a P1000 pipette puller (Sutter Instruments, Novato, CA), and filled with the recording ACSF solution ...
-
bioRxiv - Neuroscience 2020Quote: ... Keratinocytes were patch clamped in both voltage clamp and current clamp mode (holding voltage -40 mV) with a borosilicate glass pipette (Sutter Instrument Company, Novato, CA) filled with intracellular normal HEPES solution containing (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... pacemaker recordings (intracellular or extracellular) were performed with borosilicate glass sharp electrodes (30-90MΩ, P-2000 electrode puller, Sutter Instrument Company, Novato, CA, USA) using an Axoclamp 2B amplifier (Molecular Devices ...
-
bioRxiv - Neuroscience 2020Quote: ... product HS-532B) about 1 cm away from the ends of 3-barrel borosilicate glass capillary tubes (Sutter Instrument, product FG-G3BF100-75-10) and shrinking it with an infrared lamp ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell patch-clamp recordings were performed using glass pipette electrodes (resistance 3–7 MΩ) pulled from borosilicate capillaries (BF150-86-10, Sutter Instruments, Novato, CA, USA) using a P-97 pipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2020Quote: ... 3–8 MΩ) fabricated from borosilicate glass capillaries (GC150F10; Warner Instruments, Hamden, CT, USA) pulled with a horizontal puller (P-97; Sutter Instruments, Novato, CA, USA). For whole-cell voltage-clamp recordings ...
-
bioRxiv - Microbiology 2021Quote: ... The micropipettes used for microinjection were prepared from thin wall glass capillary (TW100F-4 with length 100 mm and diameter 1mm) using a Flaming/Brown Micropipette Puller (Sutter Instruments model P-87) set at pressure 360 ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... Patch pipettes were pulled to a tip resistance of 6-8 MΩ using borosilicate glass capillary tubes with a P-1000 micropipette puller (Sutter Instrument, Novato, CA, USA). Current clamp recording was performed using a Multiclamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Developmental Biology 2021Quote: ... Needles for injection were made by pulling glass capillaries with filament (Narishige catalogue # GD-1) with a pipette puller (Sutter Instrument catalogue # P-1000IVF), using the following pulling program ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording electrodes were pulled from borosilicate glass (4-8 MΩ tip resistance) using a P-97 Flaming/Brown micropipette puller (Sutter Instrument Co., Novato, CA) and filled with intracellular patch electrode solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... The electroporation solution was loaded into a glass needle (Standard Wall Borosilicate Tubing with Filament, BF100-50-10, Sutter Instruments, resistance 10-30 MΩ) and placed onto the headstage of an electroporation device (Axoporator ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected at 1 μl/min into the cochlear nucleus (CN) using pulled glass pipettes with a 20 μm opening (Sutter Instrument, P-97, U.S.A.). Two viral vectors ...
-
bioRxiv - Bioengineering 2024Quote: ... Each peptide was prepared as a 1 mg/mL solution in distilled water and 46 nL was injected into the thorax using glass capillaries pulled on a P-2000 Laser-Based Micropipette Puller (Sutter Instrument, Novato, CA, USA) held on a Nanoject II device (Drummond Scientific ...