bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (3-5 MΩ) were pulled from borosilicate glass micropipettes (2mm O.D., Warner Instruments) using a P-1000 horizontal puller (Sutter Instruments).
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes of 3-6 MΩ resistance were made using borosilicate glass capillaries using a P-1000 puller (Sutter Instruments) and filled with internal solution ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes were pulled from glass capillaries (PG52151-4, Word Precision Instruments) using a P97 puller (Sutter Instruments, California, USA). Recording pipettes had 2.0–4.0 MΩ open-tip resistance in the bath solution ...
-
bioRxiv - Neuroscience 2024Quote: Patch pipettes (3–5 MΩ) were obtained from borosilicate glass capillaries pulled with a micropipette puller (P-97, Sutter Instrument) and filled with voltage-clamp internal solution ...
-
bioRxiv - Biophysics 2024Quote: ... The pipettes for delivering the stimulation solution were pulled from 1.5 mm outside diameter borosilicate glass capillaries (BF150-86-10, Sutter Instruments) using a P-1000 pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: Patch pipettes were pulled from thin-walled borosilicate glass capillaries with filament (BF150- 110-10HP, Sutter Instrument®, Novato, CA) using a P-1000 Flaming/Brown micropipette puller (Sutter Instrument® ...
-
bioRxiv - Biophysics 2024Quote: ... Patch pipettes (∼3 MΟ resistance) were fabricated from 1.5-mm thick wall borosilicate glass capillaries (P1000, Sutter Instruments, Novato, CA). Electrophysiological parameters of each patched cell were monitored with an amplifier (AxoPatch200b ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were made from borosilicate glass with a Flaming-Brown puller (P-97, Sutter Instruments; tip resistance 5-10 MΩ). The pipette solution contained (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... Somatic whole-cell patch-clamp recordings were performed using pipettes pulled from borosilicate glass capillaries (2 mm outer/1 mm inner diameter) on a horizontal puller (P-97, Sutter Instrument). The pipettes were filled with an intracellular solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... from thick-walled borosilicate glass capillaries with an inner filament (1.5 mm outer diameter, 0.86 mm inner diameter; Sutter Instruments, Novato, CA). Pipette resistance was 4 – 5 MΩ when filled with the intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording electrode was pulled from a borosilicate glass pipette (3–5 MΩ) using an electrode puller (P-1000; Sutter Instruments) and filled with a K-gluconate-based internal solution (in mM) ...
-
Pax6 loss alters the morphological and electrophysiological development of mouse prethalamic neuronsbioRxiv - Developmental Biology 2021Quote: ... Recording pipettes were pulled from borosilicate glass capillaries (Havard Apparatus, 30-0060) on a horizontal electrode puller (P-97, Sutter Instruments) to a tip resistance of 4-6 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes made from thin-walled borosilicate glass (outer diameter 1.5 mm, internal diameter 1.1 mm; Sutter instrument BF150-110-7.5) were pulled by a model P-97 puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: Antibodies/Fc-fragment was injected to lateral ventricular of pups by glass pipette with a sharp bevel at 45 degree (BV-10 Micropipette Beveler, Sutter instrument). The diameter of pipette tip was ~40-80μm (Vogt et al. ...
-
bioRxiv - Neuroscience 2020Quote: ... Pipettes pulled from borosilicate glass capillary tubes (cat. no. G85150T-4, Warner Instruments) using a P-97 pipette puller (Sutter Instrument) were filled with the following intracellular solution (in mM) ...
-
bioRxiv - Biophysics 2022Quote: ... Patch pipettes (4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries with filaments (OD=1.5 mm, ID=0.86 mm; Sutter Instruments, Novato, CA) and filled with perfusate ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell patch-clamp electrodes were pulled from thick-wall borosilicate glass using a Brown-Flaming puller (P97, Sutter Instrument, USA). The tip of the electrode was fire-polished using a microforge (MF-830 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes were fabricated from thick-walled borosilicate glass capillaries (outer diameter: 2 mm, inner diameter: 1 mm) with a horizontal pipette puller (P-97, Sutter Instruments). The intracellular solution for soma-dendritic whole-cell recordings contained 120 mM K-gluconate ...
-
bioRxiv - Neuroscience 2020Quote: Recordings of extracellular field potentials in the pyramidal layer of CA3a region of hippocampus were obtained using glass micropipettes (15 MΩ pulled on a P-97, Sutter instruments) field with ACSF ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch-pipettes (5–13 MΩ) were made from borosilicate glass capillary with a Flaming-Brown puller (P-1000 or P-97; Sutter Instrument) and polished with a microforge ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes were pulled from borosilicate capillary glass (Havard Apparatus, 30-0060) on a horizontal electrode puller (P-97, Sutter Instruments) to a tip resistance of 4-6 MΩ and filled with K-gluconate-based internal solution (in mM ...
-
bioRxiv - Physiology 2020Quote: ... we used sharp microelectrodes (40-70 MΩ) fabricated from aluminosilicate glass capillaries (1.5mm OD 0.86mm ID) with a horizontal pipette puller (Sutter Instruments, CA, USA), and back-filled with 3M KCl ...
-
bioRxiv - Developmental Biology 2021Quote: ... Cells were assessed in the ruptured-patch whole-cell configuration of the patch-clamp technique using and EPC9 or EPC10 amplifier (HEKA) with borosilicate glass pipettes (Sutter Instruments) with 3-6 MΩ resistance when filled with pipette solution (130 mM glutamic acid ...
-
bioRxiv - Neuroscience 2022Quote: ... were pulled from borosilicate glass with an outer diameter of 1.5 mm using a P-97 micropipette puller (Sutter Instruments, USA) and filled with a solution containing 140 mM K-gluconic acid ...
-
bioRxiv - Neuroscience 2023Quote: ... in the supra-pyramidal blade of the dentate gyrus was recorded with a borosilicate glass pipette taper-pulled to an impedance of 5-7 MOhm (Sutter Instruments) and filled with the ACSF solution ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass patch pipettes (3.5−4.5 MΩ) were pulled using a P-2000 laser-based micropipette puller (Sutter Instruments, CA, U.S.A.). Current clamp recordings were conducted using a potassium gluconate based internal solution (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were fabricated from borosilicate glass capillaries with a Brown-Flamming model P-80 micropipette puller (Sutter Instruments, Novato, CA) with resistances of 4–10 MΩ when back-filled with an internal solution ...
-
bioRxiv - Neuroscience 2024Quote: ... fEPSPs responses were evoked by stimulating the Schaffer collateral with 0.2 ms pulses delivered through customized double barrel glass electrodes (Sutter Instrument Co.) and recording from stratum radiatum of area CA1 using glass pipettes filled with ACSF ...
-
bioRxiv - Neuroscience 2024Quote: Endogenous neurotransmitter release from MOC axons was evoked using electrical axon stimulation via glass micropipettes (Sutter Instrument Company, Novato, CA, USA) of ∼10-20 µm diameter containing extracellular solution described above ...
-
bioRxiv - Neuroscience 2024Quote: ... Borosilicate glass pipettes (Hilgenberg) of 6 - 8 MOhm resistance were pulled with a Flaming / Brown micropipette puller P-1000 (Sutter Instruments). The intracellular solution contained 130 mM K-gluconate ...
-
bioRxiv - Neuroscience 2024Quote: Whole-cell current-and voltage-clamp recordings were performed in a recording chamber at room temperature using pulled borosilicate glass pipettes (4-7 MΩ resistance, Sutter Instrument) filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch electrodes were pulled from thin-walled borosilicate glass capillary tubing using a pipette puller (P97; Sutter Instruments, Novato, CA, USA). Tip electrode resistance was 4.6–7.4 MΩ in artificial cerebrospinal fluid (ACSF) ...
-
bioRxiv - Neuroscience 2022Quote: ... glass electrodes with an impedance between 50-110 MΩ were pulled on a P-1000 micropipette puller (Sutter Instrument, P-1000) and placed in prelimbic cortex in lower layer 2/3 ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes with an open tip resistance of 4-6 MΩ were prepared from borosilicate glass (Sutter Instrument BF150-86-10) using a Flaming/Brown pipette puller (Sutter Instrument SU-P97) ...
-
bioRxiv - Biophysics 2023Quote: ... in positive mode with a nanospray tip pulled in-house with a Flaming/Brown P-97 micropipette puller from thin-walled glass capillaries (i.d. 0.78 mm, o.d. 1.0 mm, 10 cm length, both from Sutter Instrument Co., Novato, CA, USA). A positive potential of 1.2-1.6 kV was applied to the solution via a thin platinum wire ...
-
bioRxiv - Neuroscience 2023Quote: ... Intracellular recordings were obtained from neuronal somata in the STG using sharp glass microelectrodes prepared with the Flaming-Brown micropipette puller (P97, Sutter Instruments). They were filled with an electrolyte solution of 0.6 M K2SO4 and 20 mM KCl ...
-
bioRxiv - Neuroscience 2023Quote: ... The patch pipettes were produced from borosilicate glass capillary tubes (Hilgenberg GmbH) by using a horizontal puller (P-97, Sutter instruments) and filled with an intracellular solution containing K-gluconate 130 mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Visually guided whole-cell recordings were obtained with patch pipettes of ∼1-3-MΩ resistance for PCs and ∼3-6-MΩ resistance for MLIs pulled from borosilicate capillary glass (BF150-86-10, Sutter Instrument). Slice recordings with PC leak currents greater than 500 pA were rejected ...
-
bioRxiv - Biophysics 2023Quote: ... were fabricated from borosilicate glass with filament (GB150F-8P, Science Products GmbH) on a horizontal puller (Model P-1000, Sutter Instruments). Light was provided by a pE-800 system (CoolLED) ...
-
bioRxiv - Neuroscience 2023Quote: ... and monopolar stimulator pipettes (3 – 4 MΩ) were obtained from borosilicate glass capillaries with a horizontal pipette puller (P-97, Sutter Instruments). The internal pipette solution contained the following (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Sharp micropipettes from quartz glass capillaries with a filament (OD/ID: 1.2/0.6mm) were fabricated with a laser-based micropipette puller (Sutter Instrument #P-2000), backfilled with Calcium Green dextran [5% (v/v ...
-
bioRxiv - Biochemistry 2024Quote: The glass capillary needles for injections were prepared using glass capillaries (3.5” Drummond #3-000-203-G/X) and a micropipette puller (Sutter Instrument Company). After backfilling the glass capillary needles with mineral oil (Sigma BioReagent ...
-
bioRxiv - Neuroscience 2024Quote: ... infused with Nanoject (3-000-207, Drummond) using glass injectors (3-000-203-G/X, Drummond) pulled on a horizontal pipette puller (P-1000 Sutter Instrument). After infusion the injector was left for 3 to 5 min then withdrawn ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... Pipettes were pulled from borosilicate thin wall glass (Warner Instruments, USA) using a P-87 micropipette puller (Sutter Instruments, Novato, CA), after which the tips were fire-polished on a microforge to yield pipette resistances of 3-5 MΩ after filling with intracellular pipette solution ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes made of borosilicate glass (3-7 MΩ resistance) were pulled using a P-1000 Flaming/Brown micropipette puller (Sutter Instruments). Recordings were performed using a Multiclamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell patch-clamp recordings were performed on fluorescently labeled cells using 6–8 MΩ resistance glass microelectrodes (BF150-86-10; Sutter Instrument) containing an internal solution comprised of (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument; Novato, CA, USA) filled with artificial cerebral spinal fluid (aCSF ...
-
bioRxiv - Neuroscience 2024Quote: ... Visually guided cell-attached recordings were made in lobule X of the cerebellar vermis with 3-5 MΩ patch pipettes pulled from borosilicate glass capillaries (BF150-86-10, Sutter Instrument) with a P-97 Flaming/Brown puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes were pulled from thick-walled borosilicate glass tubing (outer diameter: 2 mm, inner diameter: 1 mm; Hilgenberg, Germany) with a horizontal puller (P-97, Sutter Instruments). The composition of the internal solution was ...
-