Labshake search
Citations for Miltenyi Biotec :
1801 - 1850 of 2875 citations for Dengue Virus Serotype 2 Envelope Protein Insect Cells since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2022Quote: ... CD4+ T cells were purified using a negative-sorting CD4+ isolation kit (Miltenyi Biotec, Inc.). CD4+ T cell isolation was done following the manufacturer’s instructions and were consistently found to be > 90% pure ...
-
bioRxiv - Immunology 2023Quote: ... The numbers of viable cells were determined using propidium iodide and a MACSQuant (Miltenyi Biotec). Before cell sorting ...
-
bioRxiv - Immunology 2023Quote: B cells were isolated with anti-mouse CD19 microbeads (Catalog:130-097-144, Miltenyi Biotec) from Cd79acre/+Zbtb18fl/fl and Cd79acre/+ mice ...
-
bioRxiv - Microbiology 2023Quote: ... Single cell suspensions were obtained by filtering through MACS® SmartStrainers (100 μm, Miltenyi Biotec), centrifuged at 500×g for 10 min (4°C ...
-
bioRxiv - Microbiology 2023Quote: ... Single cell suspensions were obtained by filtering through MACS® SmartStrainers (100 μm, Miltenyi Biotec), centrifuged at 300×g for 10 min (4°C ...
-
bioRxiv - Developmental Biology 2023Quote: ... FLs were depleted of hematopoietic cells (Ter119+CD45+Kit+CD71+) using MACS columns (Miltenyi Biotec) according to manufacturer instructions ...
-
bioRxiv - Cancer Biology 2023Quote: ... 5 × 105 cells were stained using CD117-APC (Miltenyi Biotec, 130-098-207, 1:50) and CD133-PE (Miltenyi Biotec ...
-
bioRxiv - Neuroscience 2023Quote: ... The cell nuclei were then resuspended in ice-cold MACS buffer (Miltenyi Biotec, Gaithersburg, MD) for anti-GFP MACS microbeads incubation ...
-
bioRxiv - Microbiology 2023Quote: ... and subsequently activated using the T Cell Activation/Expansion Kit (Miltenyi Biotec, 130-091-441). From this point forward ...
-
bioRxiv - Cell Biology 2023Quote: ... cells were treated with FcR-blocking reagent and human CD34 Microbeads (Miltenyi Biotec, Gaithersburg, MD) for 30 min ...
-
bioRxiv - Immunology 2023Quote: ... CD45+ cells were isolated by CD45 magnetic beads isolation kit (130-052-301, Miltenyi Biotec).
-
bioRxiv - Cancer Biology 2023Quote: ... and CD34+ cells were isolated using the CD34 Microbead kit (Miltenyi Biotec, #130-046-702). The use of the cord blood samples for research purposes was approved by the Ethics Committee of the Medical College of Wisconsin ...
-
bioRxiv - Cancer Biology 2023Quote: ... AML cells were pre-incubated with FcR-blocker (100μg/mL) (Miltenyi Biotec, Leiden, The Netherlands) and subsequently stained with anti-CD34 antibody ((Clone ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were then incubated with anti-LNGFR MACSelect microbeads (Miltenyi Biotec, cataolog 130-091-330), and the pooled population was split in half and each half was loaded on an MS column (Miltenyi Biotec ...
-
bioRxiv - Neuroscience 2023Quote: ... enzymatic cell dissociation was performed using a neural tissue dissociation Kit (Miltenyi Biotec, Cologne, Germany). Then ...
-
bioRxiv - Cancer Biology 2023Quote: ... The T cells were stimulated with anti-CD3/CD28 beads (x 25 dilution; Miltenyi Biotec) in the presence or absence of recombinant mouse TGF-β1 (5 ng/ml ...
-
bioRxiv - Immunology 2023Quote: ... naïve T cells were cultured in the presence of IL-6 (30ng/mL; Miltenyi Biotec), soluble anti-CD28 (1µg/mL ...
-
bioRxiv - Immunology 2023Quote: ... Naïve OT-I cells were isolated from lymph nodes using magnetic CD8-microbeads (Miltenyi Biotec) following manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2023Quote: ... CD8+ DCs were isolated using CD8+ dendritic cell isolation kit (Miltenyi Biotec, 130-091-169), following the manufacturer protocol.
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... One quarter of the of the cell suspension volume human anti-fibroblast Microbeads (Miltenyi Biotec) were added for 30 min at RT ...
-
Pathogenic CD8 T cell responses are driven by neutrophil-mediated hypoxia in cutaneous leishmaniasisbioRxiv - Immunology 2023Quote: ... and CD8 T cells were purified using a magnetic bead separation kit (Miltenyi Biotec, Germany). Three million CD8 T cells were transferred intravenously into RAG-/- mice subsequently infected with L ...
-
Pathogenic CD8 T cell responses are driven by neutrophil-mediated hypoxia in cutaneous leishmaniasisbioRxiv - Immunology 2023Quote: ... and CD8 T cells were purified using a magnetic bead separation kit (Miltenyi Biotec, Germany). CD8 T cells were cultured in 96 well plates “U” bottom with 5μg/mL of plate-bound anti-CD3 (clone 145-2C11 ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... the tissue suspension was passed through a 100 µm cell strainer (Miltenyi Biotec, Gaithersburg, MD). Fixed tissue was washed ...
-
bioRxiv - Immunology 2023Quote: ... CD45+ cells were enriched by using magnetic beads and MS columns (CD45 MicroBeads; Miltenyi Biotec). Cells were then sorted as single/live/CD45+ cells for single cell sequencing from baseline hearts and from the ischemic myocardium 2 days after I/R injury ...
-
bioRxiv - Cell Biology 2023Quote: Schizont stage parasites were magnetically purified using the Magnetic Cell Separation (MACS) system (Miltenyi Biotec) and added to wells of a round bottomed 96-well plate containing erythrocytes or leukofiltered CD34+ or BEL-A-derived reticulocytes in culture medium as previously described [10] ...
-
bioRxiv - Cell Biology 2023Quote: ... but with final elution from the MiniMACSTM Large Cell Column (Miltenyi BioTec Ltd, Bisley, UK) into 150μL STM.
-
bioRxiv - Genomics 2024Quote: ... we further filtered the cells using a 30μm MACS SmartStrainer (Miltenyi Biotec 130-098-458). Cell counts and viabilities were measured using an automated cell counter (NanoEnTek EVE) ...
-
bioRxiv - Immunology 2024Quote: ... for 24hrs and subjected to a Dead Cell Removal kit via magnetic separation (Miltenyi Biotec) and live M- or G-MDSCs were subsequently used for in vitro experiments.
-
bioRxiv - Genomics 2024Quote: ... Edu positive cells were detected using a MACSQuant® Analyzer 10 Flow Cytometer (Miltenyi Biotec).
-
bioRxiv - Immunology 2024Quote: ... cell medium was replaced with fresh medium supplemented with IFN-γ1b (1ng/ml, Miltenyi Biotec) and TNFα (1ng/ml ...
-
bioRxiv - Immunology 2024Quote: ... CD3+ T cells from PBMCs were separated using CD3 microbeads (Miltenyi Biotec, Bergisch Gladbach, Germany) following the manufacturer’s instructions ...
-
bioRxiv - Immunology 2024Quote: Naive T cells from spleens and lymph nodes were purified by MACS microbeads (Miltenyi Biotec) and seeded in RPMI-1640 containing 10% FBS ...
-
bioRxiv - Cell Biology 2024Quote: ... MEF feeder cells were removed using magnetic feeder removal microbeads (Miltenyi Biotec, 130-095-531) according to the manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2024Quote: ... cells were re-plated with 10 uM StemMACSTM Y-27632 ROCK inhibitor (ROCKi; Miltenyi Biotec). Media was changed every 24 hours.
-
bioRxiv - Microbiology 2024Quote: ... and filtered through a 30-µm cell strainer (MACS, Miltenyi Biotec GmbH; Bergisch Gladbach, Germany) to remove remaining mycelium ...
-
bioRxiv - Cancer Biology 2024Quote: ... Cd11b+ (Mac-1+) cells were isolated from unfractionated bone marrow using Cd11b MicroBeads (Miltenyi Biotec) following the manufacturers’ instructions.
-
bioRxiv - Molecular Biology 2023Quote: ... CH12-F3 cells were stimulated with agonist anti-CD40 antibody (0.5μg/ml; Miltenyi Biotec; FGK45.5), mouse IL-4 (5 ng/μl ...
-
bioRxiv - Biochemistry 2024Quote: ... Cells were washed three times with selection buffer and purified on LS-columns (Miltenyi Biotec) according to the manufacturer’s instructions for positive and negative selections.
-
bioRxiv - Cancer Biology 2021Quote: ... Enrichment of CD34+ cells was performed by immunomagnetic bead selection using an CliniMACS instrument (Miltenyi Biotec). After enrichment ...
-
bioRxiv - Cell Biology 2020Quote: ... Stained cells were also quantified by Flow-cytometry in a MACSQuant-VYB (Miltenyi Biotec, Surrey, UK). Data analysis was carried out by using the FlowJo software ...
-
bioRxiv - Developmental Biology 2021Quote: ... Pooled E18.5 sutures were similarly processed and red blood cell lysis (Miltenyi Biotec, 130-094-183) was performed after pelleting filtered cells ...
-
bioRxiv - Bioengineering 2022Quote: ... CD34+ haematopoietic stem and progenitor cells (HSPCs) were purified using CD34+ Microbead kit (Miltenyi Biotec, UK) according to the manufacturer protocol ...
-
bioRxiv - Cell Biology 2022Quote: ... The cells were then trypsinized and incubated with anti-CD146 antibody coated microbeads (Miltenyi Biotec Inc.) for 15 mins at 4°C to obtain the CD140b+CD146+ cells for subsequent experiments ...
-
bioRxiv - Immunology 2022Quote: ... MAIT cell staining (1 ×106 PBMC) was performed using specific surface monoclonal antibodies (All Miltenyi Biotec) namely ...
-
bioRxiv - Immunology 2022Quote: ... Naive CD4+ T cells were purified from spleens of OT II mice by MACS (Miltenyi Biotec) according to the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2019Quote: ... The labelled cells were loaded onto a MACS LS Column (Cat# 130-042-401, Miltenyi Biotec), which is placed in the magnetic field of a MACS Separator ...
-
bioRxiv - Immunology 2019Quote: ... Cells were washed and filtered through a LS magnetic column on a QuadroMACS separator (Miltenyi Biotec). Cells were then used in transcriptomic analysis ...
-
bioRxiv - Cancer Biology 2019Quote: ... CD4+ or CD8+ T cell enrichment was performed using magnetic beads (Miltenyi Biotec or STEMCELL Technologies). Naïve CD4+ T cells were isolated using a naive CD4+ T cell isolation kit (Miltenyi Biotec).
-
bioRxiv - Immunology 2019Quote: CD11c+ DCs were enriched from spleen cells using magnetic separation kits and reagents from Miltenyi Biotec and/or StemCell Technologies ...
-
bioRxiv - Genomics 2019Quote: ... The cell suspension was then labeled for oligodendrocyte marker 1:50 anti-O4-PE (Miltenyi Biotec), endhothelial cell marker 1:50 anti-CD31-PE (Miltenyi Biotec ...