Labshake search
Citations for A-M Systems :
551 - 600 of 724 citations for Oleoyl Gly Lys m PEG11 amine since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... The copper-mesh surrounding the 3-D printed head cap was connected via a stainless-steel wire (A-M Systems, #792800) to a ground screw in the skull and served as a Faraday cage ...
-
bioRxiv - Neuroscience 2023Quote: ... signals were amplified 5 to 20K times and filtered with a Model 1700 Differential AC Amplifier (A-M Systems, Sequim, WA). Rectal body temperature was recorded using a Model TC-1000 temperature controller (CWe Inc. ...
-
bioRxiv - Neuroscience 2023Quote: ... Prior to surgery, probes were mounted to a plastic microdrive (NeuroNexus, d-XL) and a stainless-steel ground wire (0.001”, A-M systems) was soldered to the reference of the headstage ...
-
bioRxiv - Neuroscience 2022Quote: ... Briefly, AS4 carbon fibers (Hexel, Stamford, CT) were aspirated into glass capillaries (0.68 mm I.D.; A-M Systems, Inc., Sequim, WA) and a DKI - 700C Vertical Pipette Puller (David Kopf Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... Carbon fiber electrodes consisted of 7-μm diameter carbon fibers (Goodfellow) inserted into a glass pipette (A-M Systems, cat# 602500) with ~150-200 μm of exposed fiber ...
-
bioRxiv - Physiology 2022Quote: ... a left lumbar and postganglionic splanchnic sympathetic nerve bundle was isolated from surrounding tissue and mounted on a stainless steel wire electrode (0.127-mm OD; A-M Systems), and covered with a silicon-based impression material (Coltene ...
-
bioRxiv - Developmental Biology 2023Quote: ... Imaging was performed on E14 (no visible clusters at experiment start) embryonic intestinal explants that had been longitudinally cut open using tungsten needles (0.004in diameter, A-M systems). The fileted intestinal explants were cultured on Corning 8.0µm pore-size polycarbonate transwell membrane inserts in 6 well plates containing 1.5mL fetal gut media (BGJb media containing 1% Pen/Strep and 0.1 mg/mL ascorbic acid with the epithelial surface facing up) ...
-
bioRxiv - Neuroscience 2023Quote: ... Stimulus pulses were elicited at an intensity range from 0.25 µA – 25 µA every 30 s with a 0.5 ms stimulus duration using a Model 2100 Isolated Pulse Stimulate (A-M Systems) to acquire the maximal fEPSP slope ...
-
bioRxiv - Neuroscience 2022Quote: ... the optopatcher was used (Katz et al., 2013, 2019; Ketzef et al., 2017a; Alegre-Cortés et al., 2021) (A-M systems). Pulses (Two-channel universal LED driver ...
-
bioRxiv - Genetics 2023Quote: ... and the free ends of the electrode wires were attached to a differential amplifier (Model 1700, A-M Systems, Sequim, WA). Mice were allowed to recover from anesthesia for 30 minutes ...
-
bioRxiv - Neuroscience 2024Quote: ... Stimuli were delivered using a constant current stimulator (330 Hz, 45 ms duration train, every 2s, Model 2100: A-M Systems).
-
bioRxiv - Neuroscience 2024Quote: ... POLI fiber implant or a standard setup with custom-made silver bipolar electrode (two silver wires with each: inner diameter: 0.127 mm; outer diameter 0.178 mm, twisted together, A-M Systems, # 786000) and a 200 µm fiber optic cannula (CFMXC10 ...
-
bioRxiv - Neuroscience 2024Quote: ... with intensities ranging from 0.1 mV to 1.0 mV were delivered to evoke fEPSPs (Isolated pulse stimulator 2100, A-M systems, USA). The first response peak was used for plotting the I/O curve ...
-
bioRxiv - Neuroscience 2024Quote: ... while the other end (adapter) was connected to four channels of a differential amplifier (Model 1700, A-M Systems, United States). A silver ground wire was inserted into the locust’s abdomen.
-
bioRxiv - Neuroscience 2024Quote: ... The center of the conical base is drilled to glue a plastic guide for introducing the tetrode composed of 4 tungsten wires (Ø 50.8/101.6 μm) insulated with Teflon (ref. 795500, A-M systems). The tail of the tetrode along with the silver ground and reference wires were gently inserted into channels holes on the EIB-16-QC (Neuralynx) ...
-
bioRxiv - Neuroscience 2024Quote: ... EJPs were generated by applying a stimulus to severed segmental nerves at a frequency of 0.2 Hz using an isolated pulse stimulator 2100 (A-M Systems). Stimulus amplitude was adjusted to consistently elicit compound responses from both type Ib and Is motor neurons ...
-
bioRxiv - Neuroscience 2024Quote: ... electrophysiological signals were recorded in the BFD cortex of 2 mice using a Parylene C-insulated tungsten microelectrode (A-M Systems) with an impedance of 2 MΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular field EPSPs were recorded with borosilicate glass pipettes (3–4MΩ) filled with ACSF using a differential extracellular amplifier (Microelectrode AC Amplifier Model 1800, A-M Systems), filtered at 2 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... Electroneurogram (ENG) recordings of the L5 and C5/C8 ventral roots were conducted using differential AC amplifier (A-M system, model 1700) with the band-pass filter between 300 Hz and 1 kHz ...
-
bioRxiv - Neuroscience 2020Quote: ... > 2.5 mA) was subcutaneously delivered by a pair of flexible steel electrodes (strand ø: 50.8 μm; coated ø: 228.6 μm; A-M Systems) inserted with the aid of a small needle (25G ...
-
bioRxiv - Bioengineering 2020Quote: ... A sniffing cannula located in the nose port was connected to a pressure sensor through an 8-12 cm long polyethylene tube (801000, A-M Systems). The pressure was transduced with a pressure sensor (24PCEFJ6G ...
-
bioRxiv - Neuroscience 2021Quote: ... ground and reference wires (insulated silver wires, PFA coated, 127 µm core dia, 178 µm outer dia, stripped at the terminals, A-M Systems) were connected to a light-weight electrode interphase board (modified EIB-18 ...
-
bioRxiv - Neuroscience 2021Quote: ... The stimulating electrode consisted of an insulated tungsten wire that passed through and extended 1.1 mm out of a 28G stainless steel tube (tungsten wire: PFA coated, 51 µm core dia, 102 µm outer dia, A-M Systems). This length was chosen so that when the tip of the tungsten wire reaches the pyramidal cell layer of the dorsal hippocampus ...
-
bioRxiv - Neuroscience 2021Quote: ... Signals were collected and band-passed filtered at 100 Hz to 1 kHz with an AC amplifier (Model 1700, A-M Systems) and live-integrated (Neurolog NL703 ...
-
bioRxiv - Neuroscience 2021Quote: ... a 12 cm pair of electrodes was prepared from Teflon-coated insulated steel wires with an outside diameter of 0.14 mm (A-M systems, # 793200). Two wires were lightly twisted together ...
-
bioRxiv - Neuroscience 2020Quote: ... ChR2-expressing axon terminals were stimulated by 5-20 ms laser pulses (3-10 mW) from a 473 nm laser delivered via fiber optic inside the recording pipette (Optopatcher, A-M Systems). To confirm the direct nature of optogenetically evoked currents 2μM TTX (Tocris ...
-
bioRxiv - Cell Biology 2021Quote: ... A stimulating electrode filled with saline was used to stimulate the severed segmental nerve using an isolated pulse stimulator (2100; A-M Systems). HFMR was induced by four trains of 100 Hz stimuli spaced 2 s apart in 0.3 mM extracellular Ca2+ ...
-
bioRxiv - Neuroscience 2020Quote: ... Target region localization was then refined using single unit microelectrode recording in combination with electrical stimulation through electrodes in SCP and GPi (single biphasic pulses <200μA, 0.2ms-duration at 2Hz max.; Model 2100, A-M Systems; Fig. 1) and proprioceptive stimulation ...
-
bioRxiv - Neuroscience 2022Quote: ... Single neuron spiking activity was pre-amplified and band-pass filtered (300– 3000 Hz) using a Model 3000 amplifier (A-M Systems). Neuronal spikes were digitized at 24.4 kHz by the RZ6 Processor (TDT) ...
-
bioRxiv - Neuroscience 2022Quote: ... For extracellular recordings we used self-wired tetrodes made out of formvar-insulated Nichrome wires (17.78 µm diameter, A-M Systems, USA), which were gold-plated to reduce the impedance to 300 – 400 kOm (controlled by nanoZ ...
-
bioRxiv - Neuroscience 2022Quote: ... A lengthwise incision was made to expose the skull and a unilateral craniotomy was performed to lower a depth electrode (PFA-coated stainless-steel wire, A-M systems) into the BLA (AP - 1.50 mm ...
-
bioRxiv - Neuroscience 2022Quote: ... was placed on the vagus nerve proximal to the implant region and connected to an isolated pulse generator (Model 2100, A-M Systems) (Figure S5a) ...
-
bioRxiv - Neuroscience 2022Quote: ... We firmly attached the 3D-printed chamber and headplate to the mouse skull using Metabond and dental cement (dental cement powder #525000; solution #526000; A-M Systems). After surgery ...
-
bioRxiv - Neuroscience 2020Quote: ... the electrode was placed at least 125 µm laterally from the recorded neuron and a model 2100 Isolated Pulse Stimulator (A-M Systems) was used to generate stimulus ...
-
bioRxiv - Neuroscience 2020Quote: ... The electrodes were made of Teflon-coated insulated steel wires with an outside diameter of 0.14 mm (A-M systems, ref 793200). For each animal ...
-
bioRxiv - Neuroscience 2020Quote: ... The neural recordings were grounded to one of the frontal screws with a stainless-steel wire (#792800, A-M Systems, Sequim, WA). Two ~4 mm x ~2 mm polished and reinforced thinned-skull windows (Drew et al. ...
-
bioRxiv - Neuroscience 2020Quote: ... STNS neuron action potentials were recorded extracellularly from isolated sections of nerves using pairs of stainless steel pin electrodes (reference and recording) and amplified via model 3500 AC amplifiers (A-M Systems). To this end ...
-
bioRxiv - Neuroscience 2022Quote: ... During each imaging session repeated electrical stimulations spaced by 20 s with a current of 750 μA at 50 Hz (100 μs pulses for 1 s) were delivered through the previously implanted bipolar twisted platinum electrodes using an isolated pulse stimulator (Model 2100, A-M Systems).
-
bioRxiv - Neuroscience 2022Quote: ... the coating was removed from a 300 µm length at one end of 10-cm-long pieces of insulated tungsten wires (A-M Systems, 50 µm bare diameter ...
-
bioRxiv - Neuroscience 2020Quote: Extracellular field stimulation was delivered by a SIU-102B bipolar stimulator (Warner) with triggering provided through an Isolated Pulse Stimulator (Model 2100; A-M Systems) via TTL cable ...
-
bioRxiv - Neuroscience 2020Quote: ... attenuated with an attenuator (PA5, Tucker Davis Technologies) and isolated from ground with a stimulus isolation unit (Model 2200, A-M Systems).
-
bioRxiv - Evolutionary Biology 2021Quote: We made microelectrodes from borosilicate glass capillary tubes (1mm outer diameter, 0.58 mm inner diameter; A-M systems #5960, Sequim, WA, USA) using a Flaming-Brown type puller (model P-97 ...
-
bioRxiv - Neuroscience 2021Quote: Antidromic action potentials elicited by laser stimulation of ChR2-eYFP-expressing terminals in the NAc core were fed into a high impedance headstage connected to a microelectrode amplifier (A-M Systems, Model 1800 ...
-
bioRxiv - Physiology 2022Quote: ... Signals from the electrodes positioned on the stomach and intestine were led into Model 3000 AC/DC differential amplifiers (A-M Systems) with the high-pass filter in DC mode ...
-
bioRxiv - Neuroscience 2022Quote: ... a second craniotomy is then drilled on top of the visual cortex where a ground wire (A-M system, Cat. No. 781000) is lowered 300 μm below the brain surface ...
-
bioRxiv - Neuroscience 2022Quote: ... A laminectomy was performed to expose L3–L5 segments of the spinal cord and extracellular recordings were made from wide dynamic range neurones in the deep dorsal horn (lamina III–V, 200–600□μm) using parylene-coated tungsten electrodes (A-M Systems, USA ...
-
bioRxiv - Neuroscience 2022Quote: Intracellular recordings were made from group Ia afferents with electrodes made from glass capillary tubes (1.5 mm and 0.86 mm outer and inner diameters, respectively; with filament; 603000 A-M Systems; Sequim, USA) pulled with a Sutter P-87 puller (Flaming-Brown ...
-
bioRxiv - Physiology 2024Quote: ... Rectangular stimulation pulses were applied via the apical pair of electrodes by use of a multiprogrammable stimulator (Model 2100, A-M Systems, USA ...
-
bioRxiv - Neuroscience 2024Quote: ... The MOC axon stimulation was applied using an electrical stimulus isolation unit (Iso Stim, AMPI or SIU isolation unit A-M System). Stimulation timing and rate (for imaging experiments ...
-
bioRxiv - Neuroscience 2024Quote: ... we marked electrode locations by passing monophasic electrical current at 100 µA for 60 seconds using a constant current stimulator (Model 2100/4100; A-M Systems) between each electrode and the ground screw to generate electrolytic lesions while mice were anesthetized ...