Labshake search
Citations for Agilent :
251 - 300 of 3885 citations for 5 Nitro 1H benzo de isoquinoline 1 3 2H dione since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Synthetic Biology 2023Quote: ... and ethanol concentrations of fermentation broths were analyzed using the Agilent 1200 HPLC system equipped with a refractive index detector (Agilent Technologies, Wilmington, DE, USA) and Rezex ROA-Organic Acid H+ (8% ...
-
bioRxiv - Biochemistry 2023Quote: ... SEC fractionation of SCs was carried out using a Sepax Nanofilm SEC-500 (Sepax, Newark, DE) on an HP1200 (Agilent Technologies, Santa Clara, CA) chromatograph ...
-
bioRxiv - Bioengineering 2024Quote: ... 5 µm (Agilent). Next ...
-
bioRxiv - Cell Biology 2021Quote: ... 3-diaminobenzidine (DAB) solution (Dako, USA) until signal was detected ...
-
bioRxiv - Cancer Biology 2022Quote: ... and KI67 (clone TEC-3, Dako) were then incubated on the tissue slices and bound antibody was detected with biotinylated goat anti-rat IgG (Southern Biotechnology) ...
-
bioRxiv - Cancer Biology 2022Quote: ... 3’-diaminobenzidine tetrahydrochloride (DAB; Dako, K3467), as chromogen ...
-
bioRxiv - Biochemistry 2023Quote: ... or a BIOSEC 3 column (Agilent; flow rate ...
-
bioRxiv - Cancer Biology 2022Quote: ... 3’ diaminobenzidine (DAB) (Dako, Carpinteria, CA) and counter-staining was done with hematoxylin ...
-
bioRxiv - Neuroscience 2024Quote: ... the sections were incubated with Hoechst (1:1500) for 5 minutes and mounted with Fluoromont (Dako) after 3 baths of PBS.
-
bioRxiv - Biophysics 2020Quote: ... Optical absorption spectra of the samples in a 300-900 nm range were recorded within about 10 s at given time intervals (about 0.3-1.0 min) in a 3 mL quartz cuvette (Helma QS1000, 1 cm pathlength) using a Cary 60 spectrometer (Agilent). Alternatively ...
-
bioRxiv - Cancer Biology 2021Quote: ... Tissues next underwent antigen retrieval by submerging sides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating at 97°C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Cancer Biology 2021Quote: ... Tissues next underwent antigen retrieval by submerging sides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating at 97°C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Immunology 2020Quote: ... Tissues next underwent antigen retrieval by submerging sides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating at 97 °C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Immunology 2020Quote: ... Tissues next underwent antigen retrieval by submerging sides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating at 97 °C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Pathology 2021Quote: ... Tissues next underwent antigen retrieval by submerging slides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating at 97°C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Pathology 2021Quote: ... Tissues next underwent antigen retrieval by submerging slides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating at 97°C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... Quantity and quality of the extracted total RNA was checked using Nanodrop spectrophotometer (NanoDrop Technologies, Wilmington, DE, USA) and Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA) respectively ...
-
bioRxiv - Immunology 2021Quote: ... RNA quantification and quality assessments were performed by ultraviolet–visible spectrophotometry (Nanodrop Technologies, Wilmington, DE) and the RNA 6000 Nano Chip Kit with the Agilent 2100 Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA). RNA quality of all samples reached a RNA integrity number (Agilent Technologies ...
-
bioRxiv - Plant Biology 2021Quote: ... Extracted RNA was quantified and qualified using a NanoDrop 8000 UV–Vis spectrophotometer (NanoDrop, Wilmington, DE, USA) and an Agilent 2100 Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA) using an Agilent RNA 6000 Nano Assay ...
-
bioRxiv - Plant Biology 2022Quote: ... RNA quantification and quality metrics were carried out using a NanoDrop 2000 spectrophotometer (NanoDrop Products, Wilmington, DE, USA) and an Agilent Bioanalyzer 2100 (Agilent Technologies, Santa Clara, CA, USA) RNAseq library preparations and sequencing were performed at the Beijing Genomics Institute ...
-
bioRxiv - Neuroscience 2021Quote: ... RNA yield was quantified with a NanoDrop Spectrophotometer (NanoDrop Technologies, Wilmington, DE, USA) and RNA integrity was assessed with Bioanalyzer 2100 RNA 6000 Nano Kit (Agilent Technologies, Santa Clara, CA, USA). All samples had an RNA Integrity Number (RIN ...
-
bioRxiv - Microbiology 2021Quote: ... Ribonucleic acid was quantified using a NanoDrop Spectrophotometer ND-100 (NanoDrop Technologies, Wilmington, DE, USA) and integrity was evaluated with a Bioanalyzer 2100 (Agilent Technologies, Santa Clara, CA, USA). Reverse transcription was performed with 2 μg of total RNA using the Reverse transcriptase Superscript II (Invitrogen ...
-
Phylogeny-metabolism dual-directed single-cell genomics for dissecting and mining ecosystem functionbioRxiv - Microbiology 2023Quote: ... GC and GC-MS analyses were performed on an Agilent 7980A gas chromatograph equipped with an Agilent 5975C mass selective detector (Agilent Technologies, Little Falls, DE, USA) and a HP-INNOWAX capillary column (30 m × 0.25mm × 0.25µm ...
-
bioRxiv - Plant Biology 2023Quote: ... RNA quantity and integrity were assessed respectively using a NanoDrop ND-1000 (NanoDrop Technologies, Wilmington, DE, USA) and a 2100 Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA). Library constructions and single-end sequencing (SE50 ...
-
bioRxiv - Physiology 2023Quote: ... The concentration and quality of each RNA sample were assessed using a NanoDrop™ND-1000 spectrophotometer (NanoDrop Technologies, Wilmington, DE) and Agilent 2100-bioanalyzer (Agilent Technologies, Santa Clara, CA)(Zhou et al. ...
-
bioRxiv - Molecular Biology 2024Quote: The quantity and quality of the isolated RNA was measured with the NanoDrop ND-2000 (NanoDrop Technologies, Wilmington, DE, USA) and analyzed with the Agilent 2100 Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA). The isolated RNA was processed using the Takara Smarter Stranded Total RNA-seq Kit v2 Pico Input Mammalian according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2022Quote: 3*10^3 of HPLFs per well were seeded into Seahorse XFe96 well plate (Agilent Technologies, 200941) for overnight ...
-
bioRxiv - Cell Biology 2021Quote: ... RNA concentration was measured by Nanodrop and 1 to 3 μg of RNA was reverse transcribed with AffinityScript Multi-Temp RT (Agilent) according to the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2020Quote: ... an optimal mutation rate (0.3–1 base/kb) for 1µg of template was adopted as recommended in GeneMorph II Random Mutagenesis kit (Agilent Technologies). The PCR products were then digested with EcoRI and HindIII and ligated into the pJF118EH vector using the same restriction enzymes ...
-
bioRxiv - Cancer Biology 2021Quote: ... Samples were subjected to antigen retrieval antigen retrieval (pH = 6.0 for cleaved caspase-3 and pH = 9.0 for cleaved PARP-1) followed by washing with PBS and incubation in hydrogen peroxide (Dako, #S2003) to inhibit endogenous peroxidase ...
-
bioRxiv - Immunology 2022Quote: ... the ELISA plates were washed 3 times with TBS buffer and a rabbit anti-human HRP antibody 1:3000 (Dako) in blocking solution was applied for 1 hour (RT ...
-
bioRxiv - Neuroscience 2021Quote: ... free floating sections were blocked with 3% donkey serum and incubated overnight with either rabbit anti-GFAP (1:10000, Dako), rat anti-CD68 (1:200 ...
-
bioRxiv - Systems Biology 2023Quote: ... Tissues next underwent antigen retrieval was carried out by submerging sides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating them at 97°C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Cancer Biology 2023Quote: ... Organoids were incubated in the following primary antibodies for 3 h at 24L: gastrin (1:1000, Cat #A0568, A0568, AB_2757270, Dako Agilent Technologies), Chromogranin A (1:100 ...
-
bioRxiv - Immunology 2024Quote: ... residues D141 of Regnase-1 and D252 of Regnase-3 were mutated to asparigines using the QuikChange II XL Site-Directed Mutagenesis Kit (Agilent) following manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2023Quote: ... Endogenous peroxidases were blocked by incubation with 3 % H2O2 and then blocked for 1 h (Dako Serum-free protein block). Sections were then incubated with the 1st primary antibody (FABP7 ...
-
bioRxiv - Cell Biology 2024Quote: ... 5[μm column (Agilent).The mobile phases were MS solvent A (H2O ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5% goat serum (Dako) for 1h ...
-
bioRxiv - Cell Biology 2024Quote: ... Step 3 was endogenous peroxidase blocking (Dako REAL Peroxidase-blocking reagent ...
-
Machine learning and data-driven inverse modeling of metabolomics unveil key process of active agingbioRxiv - Systems Biology 2024Quote: ... Gas separation was performed on the HP-5MS column (30 m 3 0.25 mm 3 0.25 mm, Agilent Technologies).
-
bioRxiv - Neuroscience 2021Quote: ... 5–20 ms at 1 Hz) controlled by a Picospritzer III (General Valve) and a pulse generator (Agilent). The rate of injection was ∼20 nl/minute ...
-
bioRxiv - Neuroscience 2021Quote: ... Mobile phase B consisted of acetonitrile:water 9:1 with 10 mM ammonium acetate + 5 μM medronic acid (Agilent), pH 9 ...
-
bioRxiv - Neuroscience 2021Quote: ... 5-20 ms at 1 Hz) controlled by a Picospritzer III (General Valve) and a pulse generator (Agilent). The rate of injection was ~20 nl/min ...
-
bioRxiv - Neuroscience 2023Quote: ... 5–20 ms at 1 Hz) controlled by a Picospritzer III (General Valve) and a pulse generator (Agilent). The speed of injection was ∼0.1 μl/10 min ...
-
bioRxiv - Plant Biology 2024Quote: ... 1uL of sample was injected with a 5:1 split ratio onto a 60m DB-5ms column (Agilent). The initial oven temperature was 120 °C with an oven ramp of 6 °C/min until 300 °C and held for 8 minutes ...
-
bioRxiv - Neuroscience 2021Quote: ... DNA was labeled with Hoechst (1:2000) for 3 min and the sections were mounted using fluorescence mounting media (Dako, S3023). All images were taken using a Zeiss Observer Z1 fluorescent microscope using a 10X objective ...
-
bioRxiv - Systems Biology 2023Quote: ... Tissues next underwent antigen retrieval was carried out by submerging sides in 3-in-1 Target Retrieval Solution (pH 9, DAKO Agilent) and incubating them at 97°C for 40 minutes in a Lab Vision PT Module (Thermo Fisher Scientific) ...
-
bioRxiv - Cancer Biology 2023Quote: ... Organoids were incubated in the following primary antibodies for 3 h at 24L: gastrin (1:1000, Cat #A0568, A0568, AB_2757270, Dako Agilent Technologies), Chromogranin A (1:100 ...
-
bioRxiv - Microbiology 2022Quote: ... The resulting membrane was blocked for 1 hr in PBS + 5% BSA (Fisher Bioreagents, BP1605-100) before being incubated overnight with primary antibodies [anti-VP1 (Dako, anti-enterovirus clone5-D8/1) or anti-eIF4G (Cell Signaling Technology ...
-
bioRxiv - Physiology 2020Quote: ... Acetone was measured using an agilent DB-35MS column (30 m 3 0.25mm i.d. 3 0.25 mm, Agilent J&W Scientific) installed in an Agilent 7890A gas chromatograph (GC ...