Labshake search
Citations for Agilent :
1701 - 1750 of 4255 citations for 6H 1 2 Thiazine 6 ethoxy 5 methyl 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... Immunofluorescence: insulin (Dako 1:1,000), PDX1 (Abcam AB47383 1:2000) ...
-
bioRxiv - Immunology 2022Quote: ... FCCP (1 μM; Agilent Technologies), OM (500 nM ...
-
bioRxiv - Cell Biology 2022Quote: ... MYOD1 (Dako, M3512; 1:100), MYOG (DSHB ...
-
bioRxiv - Neuroscience 2022Quote: ... anti-desmin (Dako, 1:500), anti-DNAJB4 (Abgent ...
-
bioRxiv - Neuroscience 2023Quote: ... GFAP (1:2000, Dako, #Z0334), mouse CD63 (1:200 ...
-
bioRxiv - Physiology 2024Quote: ... and GFAP (1:100; Dako). Slides were washed with TBS and incubated for 1 h in the dark with AlexaFluor 555 or 647 (Invitrogen ...
-
bioRxiv - Neuroscience 2024Quote: ... 1 pyruvate (Agilent #103578-100), 2 glutamine (Agilent #103579-100 ...
-
bioRxiv - Molecular Biology 2024Quote: ... 1 mM sodium pyruvate (Agilent) and 2 mM L-glutamine (Agilent ...
-
bioRxiv - Neuroscience 2024Quote: ... Rabbit-GFAP (1:1000, Dako), Goat-IBA1 (1:1000 ...
-
bioRxiv - Immunology 2024Quote: ... anti-GFAP (1:5000, Dako), anti-CD31/PECAM-1 (1:300 ...
-
bioRxiv - Cell Biology 2024Quote: ... 1 mM pyruvate (Agilent Technologies), and 2 mM glutamine (Agilent Technologies ...
-
bioRxiv - Immunology 2024Quote: ... β(1-4)-Galactosidase (Prozyme) (designated as “G”) ...
-
bioRxiv - Bioengineering 2024Quote: ... clone 22C3 (Agilent M365329-1). Primary antibodies for Western blotting are as follows ...
-
bioRxiv - Bioengineering 2024Quote: 1 mg of streptavidin (Agilent) was dissolved in 370 µL of deionized (DI ...
-
bioRxiv - Neuroscience 2023Quote: ... TauC (DAKO A0024, 1/5000), PHF1 (mouse monoclonal ...
-
bioRxiv - Cancer Biology 2022Quote: ... S100B (1:1000, Z0311, Dako) and vimentin (1:200 ...
-
bioRxiv - Neuroscience 2023Quote: ... GFAP (Dako Z0334, 1:1000), GAPDH (Millipore ...
-
bioRxiv - Cancer Biology 2023Quote: ... or CD3χ (1:1000; Dako) at room temperature for 1 h ...
-
bioRxiv - Cancer Biology 2023Quote: ... S100 (1:1000; Z0311, DakoCytomation), human vimentin (1:4000 ...
-
bioRxiv - Immunology 2023Quote: ... GFAP 1:200 (Agilent #ZO334), Lysozyme 1:150 (Agilent ...
-
bioRxiv - Bioengineering 2023Quote: ... GFAP (Dako GA524; 1:2000), Stem101 (Takara Y40400 ...
-
bioRxiv - Cell Biology 2023Quote: ... anti-Ki67 (DAKO 1:200), anti-CX43 (Abcam 1:200) ...
-
bioRxiv - Cell Biology 2024Quote: ... and insulin (Agilent, 1:500) overnight at 4 ℃ ...
-
bioRxiv - Neuroscience 2024Quote: ... GFAP (1:400, Dako, Z0334), vGlut1 (1:300 ...
-
bioRxiv - Cancer Biology 2024Quote: ... / CD3 (1:500, A0452, Agilent). Unconjugated primary antibodies were incubated with the corresponding Alexa Fluor®-labeled secondary antibodies at a 1:1000 dilution for one hour at room temperature ...
-
bioRxiv - Developmental Biology 2024Quote: ... GFAP (1/1000, Z0334 Dako), Hopx (1/500 ...
-
bioRxiv - Systems Biology 2024Quote: ... Ki67 (Dako #M7240 1:200), CTIP2 (Abcam #ab18465 1:500).
-
bioRxiv - Neuroscience 2019Quote: ... Paraffin embedded human brain sections were de-waxed for antigen retrieval with 90% formic acid (5 min) followed by citrate boiling (45min, 98°C DAKO Citrate Buffer, DAKO PT Link). Sections were then blocked using 0.1% (w/v ...
-
bioRxiv - Bioengineering 2021Quote: ... The samples were separated on an Eclipse XDB-C18 analytical column (250 mm × 4.6 mm, 5 µm, Agilent, Santa Clara, CA, USA). The mobile phase solvents were composed of 1% acetic acid in water (solvent A ...
-
bioRxiv - Neuroscience 2020Quote: ... blocked using 10% Normal Goat Serum (NGS) and incubated overnight with the following primary antibodies in 5% NGS overnight at 4°C: rabbit anti-GFAP (DAKO; #Z0334;1:1000), rat anti-L1-CAM (Millipore ...
-
bioRxiv - Plant Biology 2021Quote: ... Chromatographic separation was achieved using a DB-5 column (inner diameter, 0.25 mm × 30 m and film thickness, 1.00 μm, Agilent Technologies, Wilmingston, NC, USA). The carrier gas was helium at a flow rate of 1.1 ml min−1 ...
-
bioRxiv - Developmental Biology 2021Quote: ... All sections were washed once with PBS for 5 min and mounted with Fluorescence Mounting Medium (Dako, Agilent, Santa Clara, California, USA). Images were acquired on a fluorescent slide scanner (Zeiss Axioscan ...
-
bioRxiv - Developmental Biology 2021Quote: ... All sections were washed once with PBS for 5 min and mounted with Fluorescence Mounting Medium (Dako, Agilent, Santa Clara, California, USA). Images were acquired on a fluorescent slide scanner (Zeiss Axioscan ...
-
bioRxiv - Cancer Biology 2020Quote: ... Samples were washed twice with PBS + 0.5% Triton X-100 and then rinsed one time with PBS before mounting with DAKO Fluorescence Mounting Medium (S3023; Dako NA Inc.). Images were analyzed with a Nikon Eclipse Ti fluorescence microscope with a Plan Fluor 40 Å∼ /1.30 Oil DIC N2 objective ...
-
bioRxiv - Physiology 2019Quote: ... Endogenous peroxidase was blocked using the EnVision FLEX Peroxidase-Blocking kit followed by two washes for 5 min each (Dako wash buffer). Sections were incubated for 60 min with a rabbit anti-KCNN4 primary antibody (AV35098 ...
-
bioRxiv - Molecular Biology 2019Quote: ... The original eGFP-C2-DEF6 plasmid (5) was used to generate the mutant DEF6 proteins by mutagenesis PCR (QuikChange Lightning Multi Site-Directed Mutagenesis Kit, Agilent Technologies, #210516). All mutations were verified by sequence analysis (see Suppl ...
-
bioRxiv - Microbiology 2020Quote: Each ELV and MV preparation were reconstituted in 10 μl of 5% formic acid and injected onto a 50 mm 300 μm C18 trap column (Agilent Technologies, USA). The samples were then desalted for 5 min at 30 μl/min using 0.1% formic acid and the peptides were then eluted onto an analytical nano-HPLC column (150 mm × 75 μm 300SBC18 ...
-
bioRxiv - Zoology 2020Quote: ... 5890 Series II gas chromatograph equipped with an HP-5 column (30 m×0.32 mm ID× 0.25 mm) (Agilent, Palo Alto, CA, USA). The oven temperature was held at 40 °C for 5 min ...
-
bioRxiv - Molecular Biology 2021Quote: ... column protected with an ZORBAX RRHD Eclipse Plus C18 5 × 2.1 mm ID (1.8 μm) guard column (Agilent Technologies, Foster City, CA). The mobile phase consisted of water and methanol (both added 0.1% formic acid ...
-
bioRxiv - Genomics 2020Quote: Dried peptides were separated by high pH reverse phased liquid chromatography on an Agilent 1100 HPLC system using a Zorbax Eclipse column (2.1 × 150 mm, 5 um) (Agilent Technologies, Palo Alto). Peptides were eluted with a linear gradient of 20 mM ammonium formate pH 10 ...
-
bioRxiv - Cancer Biology 2022Quote: ... The membranes were washed thrice for 5 min in TBS-T and incubated with Horseradish peroxidase secondary antibodies (DAKO, Santa Clara, USA) for 1 hr at RT ...
-
bioRxiv - Plant Biology 2023Quote: ... samples were separated on an Eclipse XDB-C18 analytical column (250 mm x 4.6 mm, 5 μm, Agilent, Santa Clara, CA, USA). The mobile phase solvents were composed of 1% acetic acid in water (solvent A ...
-
bioRxiv - Cell Biology 2022Quote: ... PSC27 was seeded at a density of 5 × 104 cells/ well in the XF24 cell culture microplate (Agilent Technologies, 04721 and Q01321) at a 37[5% CO2 incubator for overnight ...
-
bioRxiv - Neuroscience 2024Quote: ... fibroblasts were seeded at 45 × 103 cells per well (5-10 replicates per cell line) in fibroblast growth media in a Seahorse XFe24 Microplate (Agilent, 100777-004) and incubated for 24 hours to allow cells to adhere ...
-
bioRxiv - Cancer Biology 2024Quote: ... Drug was then washed out and 1x105 cells plated in 5 replicate wells for immediate analysis using the Mito Stress Test Kit (Agilent, 103015-100) according to the manufacturer’s instructions and using the following drug concentrations ...
-
bioRxiv - Cell Biology 2023Quote: ... Cells were then washed in PBS 5 x 5 mins, then mounted with a cleaned glass coverslip (#1.5, 24 mm x 60 mm) in mounting media (Dako; Pathology Products, S3023).
-
bioRxiv - Molecular Biology 2023Quote: ... column protected with an ZORBAX RRHD Eclipse Plus C18 5 x 2.1 mm ID (1.8 µm) guard column (Agilent Technologies, Foster City, CA). The mobile phase consisted of water and methanol (both added 0.1% formic acid ...
-
bioRxiv - Neuroscience 2023Quote: ... Pools were diluted to 5 ng/µL and quality and size are assessed using Agilent DNA High Sensitivity chip (Agilent Technologies, Inc.) on the Bioanalyzer ...
-
bioRxiv - Molecular Biology 2023Quote: A fluorescent image of rehydrated brain tissue with a thickness of 275 μm stained with Amy tracker and placed on glass microscopic slides was acquired using the manual mode in a Cytation 5 multimode reader (Agilent Technologies, USA). Montage images were collected at 4x and 20x magnification ...
-
bioRxiv - Genetics 2023Quote: ... Kallisto quant settings were adjusted to -b 5 -l 160 -s 20 - -single - -threads 4 based on fragment lengths determined by the Agilent 4200 TapeStation (Agilent Technologies, Inc.)