Labshake search
Citations for Agilent :
1301 - 1350 of 6807 citations for Creatinine Serum Kit 2 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... Endogenous peroxidase was blocked using a ready-to-use peroxidase-blocking solution (S202386-2, Dako). The primary antibody was diluted in antibody diluent (S080983-2 ...
-
Adolescent parvalbumin expression in the left orbitofrontal cortex shapes sociability in female micebioRxiv - Animal Behavior and Cognition 2023Quote: ... for 2 hours at RT before mounting them in clear mounting medium (DAKO, cat#S3023). We imaged fluorescent signals of mounted brain sections under a scanning microscope (ZEISS ...
-
bioRxiv - Immunology 2023Quote: ... and 2 min hold time at each temperature using Stratagene DSF Instrument (Agilent, Model 401513). Fluorescence data was collected using three samples and three buffer blanks using SYPRO (610 nm ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... after which it was read at 595 nm in Epoch 2 Microplate Spectrophotometer (Biotek/Agilent). The standard curve was constructed using BSA dilutions ranging from 125 to 1,000 µg/mL (Quick Start Bovine Serum Albumin Standard ...
-
bioRxiv - Neuroscience 2023Quote: ... HRP-conjugated polyclonal antibody (goat anti-rabbit) was purchased from DakoCytomation (Glostrup, Denmark; D048701-2). Mouse LH reference prep (AFP5306A ...
-
bioRxiv - Immunology 2024Quote: ... Cells (1-2 × 105) were plated in Poly-D-Lysine coated 96-well microplates (Agilent) with 4-5 technical replicates ...
-
bioRxiv - Molecular Biology 2023Quote: ... goat anti-rabbit IgG (250 ng ml−1, 1% BSA in PBST; Agilent, P044801-2) or rabbit anti-goat IgG (500 ng ml−1 ...
-
bioRxiv - Microbiology 2023Quote: ... Growth curves of three biological triplicates were performed using an EPOCH 2 microplate spectrophotometer (Agilent) with constant orbital shaking at 42°C ...
-
bioRxiv - Microbiology 2024Quote: ... The plasmid pEGFP-Dynamin 2.WT was constructed using a Quik Change II XL (Agilent) site-directed mutagenesis kit to change the GCC (alanine ...
-
bioRxiv - Immunology 2023Quote: ... Antibodies were diluted to appropriate working concentration using Antibody Diluent (S302283-2, Agilent Technologies Inc).
-
bioRxiv - Cancer Biology 2024Quote: ... Proteins were visualized with 3,3′-diaminobenzidine (DAB) (K346811-2, Agilent Technologies, Inc., Santa Clara, CA) or Vina Green (BRR807AS ...
-
bioRxiv - Biophysics 2021Quote: ... The thermal variations were in the range 25-95°C in a stepwise increment of 1 °C/minute step and using a 96-well PCR plate (Agilent Technologies) sealed with optical quality sealing tape (Microseal® ‘B’ seal from BIO-RAD) ...
-
bioRxiv - Cell Biology 2020Quote: ... Each well of a Seahorse XFe24 Utility Plate was filled with 200 μL of Seahorse XF Calibrant Medium (Agilent; 100840-000). The Seahorse sensor cartridge was added to the utility plate ...
-
bioRxiv - Immunology 2019Quote: ... Immuno-affinity purification through Protein-A Sepharose beads covalently bound to W6-32 antibodies was performed in a format of 96-well single-use micro plate with 10 µm polypropylene membranes (SeaHorse Bioscience). The plates were then washed 4 times with 2mL 150 mM NaCl and 20 mM Tris HCl (buffer A) ...
-
bioRxiv - Bioengineering 2021Quote: ... were measured in hypoxic hCMEC/D3 monolayers (20,000 cells/well cultured for four days) in a Seahorse XF96 plate by XF analysis (XF24, Agilent Seahorse Technologies) as previously described [43] ...
-
bioRxiv - Immunology 2021Quote: ... SC-macrophages or SC-macrophages treated with 10 nM RvD1 as above were seeded (30,000 cells/well) on a Seahorse XF96 cell culture plate (Agilent, #102601-100). The cells were incubated in glucose-free ...
-
bioRxiv - Cell Biology 2022Quote: ... only 10 μL of MTS reagent was added to plate wells because there was not enough reagent to add 20 μL to all 96 wells.) End-point absorbance measurements were taken with a plate reader at 490 nm (BioTek Instruments, Agilent Technologies).
-
bioRxiv - Molecular Biology 2020Quote: HeLa and MDA-MB-231 cells were plated accordingly as low (50% confluency) and high (100% confluency) density cultures in 24 well cell plates (Seahorse bioscience) in DMEM growth medium containing 10% FBS and placed in a 5% CO2 incubator ...
-
bioRxiv - Cell Biology 2022Quote: ... were isolated by flow cytometric cell sorting into 96-well plates and preamplification-free single-cell whole genome sequencing libraries prepared using a Bravo automated liquid handling platform (Agilent Technologies) as previously described31,32 ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... 3-5 mg of homogenized powder was pressured on a diamond ATR plate using self-levelling sapphire anvil of a Cary 660 Fourier transform infrared (FTIR) spectrometer (Agilent Technologies) coupled with Golden Gate single-reflection diamond Attenuated Total Reflectance (ATR ...
-
bioRxiv - Cell Biology 2020Quote: ... parental HCT116 cells and HCT116 cells with SMYD5 overexpression (OE) or knockout (KO) were seeded in 96-well plate (in triplicates) (#101085-004, Seahorse Bioscience) one day before measurement ...
-
bioRxiv - Physiology 2020Quote: ... Rod shaped adult cardiomyocytes were collected by settling down of cells and plated in 24 well plates for XF24e Extracellular Flux Analyzer analysis (Seahorse Bioscience) or on glass coverslips for confocal imaging.
-
bioRxiv - Cancer Biology 2020Quote: ... we plated A101D and MeWo cells at 30,000 live cells per well in a 96-well plate (Agilent, Santa Clara, CA). Cells were plated in either control or homocysteine media and incubated for 24 hours ...
-
bioRxiv - Microbiology 2020Quote: ... Single-cell clones were made for each strain by depositing epimastigotes into a 96-well plate at a density of 0.5 cell/well by using a MoFlow cell sorter (Dako-Cytomation, Denmark). One healthy clone that has confirmed to have cycled through all life stages was chosen for sequencing for each strain ...
-
bioRxiv - Bioengineering 2022Quote: Cells were dissociated from differentiation wells and seeded at 8 × 104 cells well−1 in CM support medium on Matrigel-coated XFe96 monolayer plates (Agilent Technologies). Culture medium was changed the next day to the well’s respective treatment ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were then washed and 5 × 105 osteoclasts were seeded onto a XF96 plate containing Seahorse XF RPMI medium (Agilent Technologies). The cells were left for 1 h at 37 °C after which the different metabolic drugs were injected (oligomycin 1μM ...
-
bioRxiv - Microbiology 2022Quote: ... Excess dye was removed by media change and the fluorescence at ex/em 574/594 was measured on a Biotek Neo plate reader (Agilent Technologies).
-
bioRxiv - Microbiology 2023Quote: ... OD600 nm was measured at regular 40 minutes intervals for up to 14 h in a Synergy H1 plate reader (Agilent, USA). Experiments were conducted in triplicates ...
-
bioRxiv - Microbiology 2022Quote: ... 100 μl of 1N sulfuric acid was added to each well and absorbance was measured at A450 and A650 using a Synergy H1 plate reader with Gen5 analysis software (Agilent Technologies). IgG endpoint titers were determined as 4-fold above the average absorbance of those wells not containing primary antibody.
-
bioRxiv - Systems Biology 2023Quote: The kinetic data in this study are published and were acquired from xCELLigence assays using the xCELLigence Real Time Cell Analysis (RTCA) Single Plate device (Agilent Technologies) (Dankwa et al ...
-
bioRxiv - Cell Biology 2022Quote: ... The concentrations of purified EMC complexes for disulfide crosslinking were normalized by measuring GFP fluorescence on a BioTek Synergy HTX plate reader (Agilent, USA). Normalization was verified by SDS-PAGE and Sypro Ruby staining (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... Library quality and fragment size of the plate pools was checked using the High Sensitivity DNA Chip on a 2100 Bioanalyzer (Agilent Technologies). DNA concentration was measured with 1×dsDNA HS Assay Kit on a Qubit 4 Fluorometer (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2023Quote: ... MIC values were determined at 18 hours post-inoculation by reading optical density at 600 nm (OD600) on a Synergy Neo2 Multi-Mode Plate Reader (Agilent BioTek), and inhibition of growth defined as OD600<0.5 above background ...
-
bioRxiv - Bioengineering 2024Quote: ... Fluorescence was quantified using an excitation of 530/15 nm and emission of 590/15 nm on a fluorescent plate reader (BioTek Cytation 5, Agilent Technologies).
-
bioRxiv - Bioengineering 2024Quote: ... DMMB solution was added (200 µL/well) and absorbance was measured at 540 nm and 590 nm using a plate reader (BioTek Cytation 5, Agilent Technologies). For all samples ...
-
bioRxiv - Immunology 2024Quote: A total of 10 µg/ml rHA were coated on an ELISA plate at 4 °C ON and afterwards incubated with rabbit anti-HA antibody (1:2000 dilution) (Dako, A0001) 2h at RT ...
-
bioRxiv - Microbiology 2024Quote: ... OD600 was measured at regular 30-minute intervals for up to 12 h in a Synergy H1 plate reader (Agilent, USA).
-
bioRxiv - Microbiology 2024Quote: ... The plate was sealed with a gas permeable seal (Azenta Life Sciences 4ti-0516/96*) and incubated at 37°C and 237 cpm for indicated times in a Synergy H1 plate reader (Agilent BioTek). OD600nm was measured every 10 min ...
-
bioRxiv - Zoology 2021Quote: ... with Agilent DNA 1000 Kit (Agilent Technologies). Subsequently ...
-
bioRxiv - Cell Biology 2019Quote: ... The Seahorse MitoStress kit (103015-100, Agilent) was used to prepare dilutions of the mitochondrial inhibitors which had the following final concentrations ...
-
bioRxiv - Biochemistry 2021Quote: ... The QuikChange Site-Directed Mutagenesis kit (Stratagene) was used to introduce mutations into Env in plasmid pRS1 as described before ...
-
bioRxiv - Molecular Biology 2021Quote: ... using RNA 6000 pico kit (Agilent Technologies). Directional polyA RNA-Seq libraries were constructed using the TruSeq Stranded mRNA library prep kit (Illumina) ...
-
bioRxiv - Neuroscience 2020Quote: ... D1000 ScreenTape kit (Agilent Technologies; 5067-5582), Qubit(r ...
-
bioRxiv - Molecular Biology 2020Quote: ... using the RNA 6000 Nano kit (Agilent). Minute run-to-run shifts in band sizes are due to inherent limitations of the instrument.
-
bioRxiv - Immunology 2021Quote: ... with the RNA 6000 Pico kit (Agilent) in order to calculate RNA integrity ...
-
bioRxiv - Immunology 2019Quote: ... Bioanalyzer fragment analysis (HS DNA Kit, Agilent) and KAPA library quantification qPCR (Roche) ...
-
bioRxiv - Genomics 2019Quote: ... with an RNA 6,000 Nano Kit (Agilent). RNA sequencing libraries were made using the TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat kit (Illumina ...
-
bioRxiv - Physiology 2019Quote: ... with the Mito Stress Test Kit (Agilent). Chemicals (1μM oligomycin ...
-
bioRxiv - Systems Biology 2019Quote: ... and Bioanalyzer RNA 6000 Nano Kit (Agilent), respectively.
-
bioRxiv - Microbiology 2019Quote: ... with the High Sensitivity DNA kit (Agilent). The concentration of libraries was quantified using Picogreen dsDNA assay as above ...