Labshake search
Citations for Agilent :
1001 - 1050 of 7508 citations for Human High Sensitive Interleukin 8 IL8 CLIA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... FLAG-tagged human SLFN14 D249A was generated by site directed mutagenesis with the QuickChange Lightning Site-Directed Mutagenesis Kit (Agilent) using reverse primer SS1 (5’-atccaccccaatgaggacatatcc-3’ ...
-
bioRxiv - Cancer Biology 2023Quote: ... exome capture was performed on 200 ng DNA using a customised version of the Agilent Human All Exome V5 Kit (Agilent) according to the manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2023Quote: ... Patient M03’s DNA was captured with the SureSelect Human All Exon V6 Kit (Agilent Technologies, Santa Clara, CA, USA) and sequenced on a NextSeq500 (Illumina ...
-
bioRxiv - Cell Biology 2024Quote: Whole exome sequencing on genomic DNA of the patient was performed using the SureSelect Human All Exon V6 kit (Agilent) on an Illumina HiSeq 4000 sequencer ...
-
bioRxiv - Biochemistry 2022Quote: ... using 8×60K yeast genome DNA arrays (Agilent, Array #031697) with an average probe spacing of ca ...
-
bioRxiv - Plant Biology 2021Quote: ... Signal intensities were imported into Genespring (Version 8; Agilent Technologies), and an RMA normalization was performed without transformation ...
-
bioRxiv - Cancer Biology 2020Quote: ... slides were blocked with goat serum (DAKO; Cat #: X090710-8) and incubated overnight with anti-BrdU antibody (Calbiochem ...
-
bioRxiv - Neuroscience 2023Quote: ... or directly into 8-well Seahorse XF HS miniplates (Agilent) coated with 15 µg/mL poly-L-ornithine and 10µg/mL laminin ...
-
bioRxiv - Cell Biology 2020Quote: ... A High sensitivity DNA chip (Agilent Technologies) was used to control the library's size distribution and quality ...
-
bioRxiv - Immunology 2021Quote: ... and Bioanalyzer High Sensitivity DNA assay (Agilent). Illumina cDNA library was prepared using Nextera XT DNA Library Preparation Kits according to manufacturer protocol ...
-
bioRxiv - Genomics 2020Quote: ... and High Sensitivity DNA Bioanalyzer chip (Agilent). The library was sequenced using Illumina Miseq PE150 or Hiseq PE300.
-
bioRxiv - Genomics 2020Quote: ... and High Sensitivity DNA Bioanalyzer chip (Agilent). The library was sequenced using Illumina Miseq and ∼1 million paired-end reads of 150 bp were used for each sorted droplet ...
-
bioRxiv - Genomics 2020Quote: ... Agilent DNA High Sensitivity Chips (Agilent Technologies) were used to check library size and quality ...
-
bioRxiv - Neuroscience 2021Quote: ... High Sensitivity DNA ScreenTape (Agilent, 5067-5584) was used to verify the fragment length distribution of the library ...
-
bioRxiv - Developmental Biology 2020Quote: ... High Sensitivity DNA ScreenTape (Agilent, 5067-5584) was used to verify the fragment length distribution of the library ...
-
bioRxiv - Cancer Biology 2022Quote: ... High Sensitivity D1000 ScreenTape (Agilent, # 5067-5584), Qubit fluorometer and Qubit dsDNA HS Assay (ThermoFisher ...
-
bioRxiv - Neuroscience 2022Quote: ... and the Bioanalyzer High Sensitivity Analysis (Agilent). Libraries were multiplexed and sequenced on the Illumina NextSeq or HiSeq2500 to obtain ∼30 million single end ...
-
bioRxiv - Biochemistry 2022Quote: ... following the High Sensitivity Bioanalyzer protocol (Agilent). Libraries were then loaded on an Illumina MiSeq at 10 pM and run at 300 cycles (150×2 ...
-
bioRxiv - Pathology 2022Quote: ... and Bioanalyzer High Sensitivity (Agilent Technologies, USA). One sample from the control group was excluded from sequencing due to its low quality ...
-
bioRxiv - Molecular Biology 2019Quote: ... using high sensitivity DNA chips (Agilent Technologies). Samples were pooled and sequenced on a NextSeq 500 (Illumina ...
-
bioRxiv - Genomics 2021Quote: ... High Sensitivity DNA assay (Agilent, 5067-4626). 250ng cDNA per sample was prepared for rapid adapter ligation (approximately 190 fmol per sample).
-
bioRxiv - Genetics 2020Quote: ... and High Sensitivity DNA Bioanalyzer chips (Agilent). For confirmation of sequence identity ...
-
bioRxiv - Immunology 2020Quote: ... using High Sensitivity D1000 ScreenTapes (Agilent Technologies). Libraries were quantified by qPCR using a KAPA Library Quant Kit (KAPA Biosystems) ...
-
bioRxiv - Cancer Biology 2020Quote: ... high-sensitivity DNA chips (Agilent 5067-4626) and KAPA qPCR (Kapa Biosystems KK4824) ...
-
bioRxiv - Immunology 2021Quote: ... and Bioanalyzer High Sensitivity DNA assay (Agilent). The library samples were performed on Illumina HiSeq (2X150bp and dual index configuration ...
-
bioRxiv - Developmental Biology 2020Quote: ... High Sensitivity DNA ScreenTape (Agilent, 5067-5584) was used to verify library sizes ...
-
bioRxiv - Immunology 2021Quote: ... High Sensitivity DNA chip (Agilent, 5067-4626). Libraries were sequenced on the Illumina NovaSeq platform with the following read lengths ...
-
bioRxiv - Immunology 2022Quote: ... using High Sensitivity D1000 ScreenTapes (Agilent Technologies). Libraries were quantified by qPCR using a KAPA Library Quant Kit (KAPA Biosystems) ...
-
bioRxiv - Immunology 2022Quote: ... High Sensitivity DNA chip (Agilent, 5067-4626). Libraries were sequenced on the Illumina NovaSeq platform with the following read lengths ...
-
bioRxiv - Neuroscience 2023Quote: ... using High Sensitivity chip (Agilent #5067-4627). Sample libraries were pooled and sequenced across a single lane using NovaSeq 6000 S4 platform using 150bp pair-end reads (Novogene ...
-
bioRxiv - Neuroscience 2022Quote: ... High-sensitivity RNA ScreenTape System (Agilent, Inc.) was used on the TapeStation and RNA 6000 nano kit (Agilent ...
-
bioRxiv - Neuroscience 2023Quote: ... using High Sensitivity chip (Agilent #5067-4627). Sample libraries were pooled and sequenced across a single lane using NovaSeq 6000 S4 platform using 150bp pair-end reads (Novogene ...
-
bioRxiv - Immunology 2023Quote: ... and BioAnalyzer High Sensitivity DNA Chip (Agilent). Libraries were diluted to 2 nM and pooled for sequencing in the following proportions ...
-
bioRxiv - Developmental Biology 2023Quote: ... and High Sensitivity RNA ScreenTape Assay (Agilent), respectively ...
-
bioRxiv - Molecular Biology 2023Quote: ... and BioAnalyzer High Sensitivity DNA Analysis (Agilent) were used to determine library concentration and their average size ...
-
bioRxiv - Molecular Biology 2023Quote: ... and Bioanalyzer High Sensitivity DNA Analysis (Agilent) prior to sequencing on either an Illumina HiSeq2500 or NovaSeq6000 ...
-
The T-cell niche tunes immune function through modulation of the cytoskeleton and TCR-antigen forcesbioRxiv - Bioengineering 2024Quote: ... a high-performance liquid chromatography (HPLC, Agilent) 1100 with an AdvanceBio Oligonucleotide C18 column (Agilent # 653950-702 ...
-
bioRxiv - Cancer Biology 2023Quote: ... high-sensitivity DNA chips (Agilent 5067-4626) and KAPA qPCR (Kapa Biosystems KK4824) ...
-
bioRxiv - Cell Biology 2023Quote: ... High-fidelity DNA polymerase PfuUltra II (Stratagene) was performed for site-directed mutagenesis ...
-
bioRxiv - Developmental Biology 2023Quote: ... using High Sensitivity RNA ScreenTape (Agilent Technologies). All samples passed quality control.
-
bioRxiv - Cell Biology 2024Quote: ... high-sensitivity DNA chips (Agilent 5067-4626), and KAPA qPCR (Kapa Biosystems KK4824) ...
-
bioRxiv - Microbiology 2024Quote: ... and High Sensitivity D5000 ScreenTape (Agilent Technologies), and subsequently sequenced on Illumina NextSeq500 with custom primers according to the original protocol (38).
-
bioRxiv - Biochemistry 2020Quote: Human ISG15 cDNA was amplified by RT-PCR from universal human reference RNA (Agilent 740000-41), adding BamHI and NotI restriction sites at the 5’ and 3’ ends respectively ...
-
bioRxiv - Cell Biology 2023Quote: Non-codon optimised sequences were amplified from a human cDNA library (MegaMan human transcription library, Agilent). Mis18α ...
-
bioRxiv - Genomics 2019Quote: ... SureSelect Human All Exon V6 (Agilent), and the Human Core Exome Kit + RefSeq V1 (Twist) ...
-
bioRxiv - Pathology 2019Quote: ... and mouse anti-human CD31 (DAKO) was applied overnight at 4°C ...
-
bioRxiv - Genetics 2021Quote: ... Universal Human Reference RNA (UHRR, Agilent) was spiked into each of the samples for a final RNA amount of 300 ng to balance the RNA concentrations in the pools ...
-
bioRxiv - Neuroscience 2021Quote: ... Anti-human tau (Dako, 1:10,000), the phosphorylation specific anti-tau antibody Ser396/Ser404 (PHF1 ...
-
bioRxiv - Neuroscience 2019Quote: ... total tau (total human tau, Agilent), Tau-1 (Millipore) ...
-
The heterogeneity of the DNA damage response landscape determines patient outcomes in ovarian cancerbioRxiv - Cell Biology 2021Quote: ... SureSelect Human All Exon V6 (Agilent) exome libraries were prepared and samples were paired-end whole exome sequenced (WES ...