Labshake search
Citations for Agilent :
951 - 1000 of 7508 citations for Human High Sensitive Interleukin 8 IL8 CLIA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2022Quote: ... product size distribution and quantity were assessed on a Bioanalyzer using an Agilent 2100 high-sensitivity DNA assay kit (5067-4626, Agilent Technologies). The library preparation (KAPA Hyper Plus Library prep kit ...
-
bioRxiv - Immunology 2022Quote: ... the cDNA was evaluated for size distribution and quantity using the Fragment Analyzer High Sensitivity NGS Fragment Analysis Kit (Agilent Technologies) and the Qubit dsDNA HS Assay Kit (ThermoFisher ...
-
bioRxiv - Genomics 2022Quote: ... Libraries were individually cleaned-up with 0.9 volumes of sample purification beads and concentration and size distributions were measured by Qubit™ dsDNA high sensitivity kit and by Agilent 2100 Bioanalyzer with the Agilent high sensitivity DNA kit ...
-
bioRxiv - Plant Biology 2022Quote: ... The quality of the libraries was assessed using the Agilent 2100 High Sensitivity DNA Kit (Agilent Technologies, Santa Clara, CA, USA) and subjected to paired-end sequencing on the Illumina HiSeq 2500 platform (Illumina ...
-
bioRxiv - Microbiology 2022Quote: ... The Agilent High Sensitivity DNA Kit for naturally contaminated shellfish was used to visualise second-round PCR products for Bioanalyzer 2100 (Agilent Technologies).
-
bioRxiv - Plant Biology 2022Quote: ... The cDNA libraries were barcoded individually and analyzed for quantity and quality with the High Sensitivity DNA Analysis Kit in the Agilent 2100 Bioanalyzer (Agilent, USA). cDNA libraries were pooled in equal amounts for sequencing (single end ...
-
bioRxiv - Bioengineering 2022Quote: ... and the size distribution was confirmed using a High Sensitivity DNA Kit for Bioanalyzer (Agilent Technologies, Cat. No. / ID: 5067-4626). Libraries were sequenced on an Illumina NextSeq2000 in paired end mode with the read length of 50 nt and sequencing depth of 20 million reads per library ...
-
bioRxiv - Microbiology 2022Quote: ... on a Qubit Fluorometer (invitrogen) and fragment length was assessed with an Agilent 2100 Bioanalyzer (Agilent High sensitivity DNA Kit, Agilent). Samples were equimolarly pooled and sequenced on NextSeq™ 500 High Output Kit v2.5 (75 cycles ...
-
bioRxiv - Neuroscience 2023Quote: ... Required quality control steps and quantification measurements within this protocol were performed using the Agilent High Sensitivity DNA Kit (5067-4626, Agilent Technologies) and the KAPA Library Quantification Kit (2700098952 ...
-
bioRxiv - Microbiology 2022Quote: ... was performed to remove adapter dimers and 1 μl of the cleaned pool was visualised using the Agilent High Sensitivity DNA Kit for Bioanalyzer 2100 (Agilent Technologies) to confirm adapter-dimer removal.
-
bioRxiv - Neuroscience 2023Quote: ... The quality of each library was assessed by capillary electrophoresis on FragmentAnalyzer using the NGS High Sensitivity kit (Agilent, DNF-474). Sample libraries were pooled and sequenced on Illumina NovaSeq 2000 targeting 50,000 read pairs per tissue-covered spot.
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Fragment size distributions of tagmented and dual indexed libraries were analyzed by capillary gel electrophoresis using a Bioanalyzer High Sensitivity DNA kit (50067-4626, Agilent, USA). Up to 384 high quality libraries with size distribution between 250-1000bp were pooled using equal molar quantities ...
-
bioRxiv - Cell Biology 2023Quote: ... gene expression libraries were constructed using 1-100 ng of each amplified cDNA library and quantified using the TapeStation High Sensitivity D1000 kit (Agilent, Germany) to determine the average fragment size and library concentration ...
-
bioRxiv - Microbiology 2023Quote: ... samples were run on an Agilent Bioanalyzer 2100 using an Agilent High Sensitivity DNA Kit as recommended by the manufacturer (Agilent Technologies). Concentration of the libraries was determined using the Qubit® dsDNA HS Assay Kit as recommended by the manufacturer (Life Technologies GmbH ...
-
bioRxiv - Genomics 2023Quote: ... and their size range was checked by capillary electrophoresis using with the DNA high sensitivity kit and a Bioanalyzer 2100 (Agilent Technologies). Libraries were diluted to 1 nM and pooled equimolarly ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The average length of the DNA libraries was evaluated using Agilent Bioanalyzer 2100 and a High Sensitivity Kit (Agilent Technologies, USA) and the concentration of the DNA libraries was determined with a Qubit device (Thermo Fisher Scientific ...
-
bioRxiv - Bioengineering 2023Quote: ... and the size distribution was confirmed using a High Sensitivity DNA Kit for Bioanalyzer (Agilent Technologies, Cat. No. / ID: 5067-4626). Libraries were sequenced on an Illumina NextSeq2000 in paired end mode with the read length of 50 nt and sequencing depth of 25 million reads per library ...
-
bioRxiv - Cancer Biology 2023Quote: ... The libraries were quality controlled using a 2100 Bioanalyzer system with Agilent High Sensitivity DNA Kit (Agilent Technologies, Inc., 5067-4626) and quantified with Qubit™ 1X dsDNA HS Assay Kit (Invitrogen ...
-
bioRxiv - Cancer Biology 2023Quote: ... The quality of sequencing libraries was validated with a Bioanalyzer 2100 using the Agilent High Sensitivity DNA Kit (Agilent, 5067-4626). The pooled sequencing libraries were quantified and sequenced on either the MiSeq (v2 or v2 nano ...
-
bioRxiv - Genetics 2023Quote: ... The final libraries were then quality checked and quantified for multiplexing using the Bioanalyzer High-Sensitivity DNA kit (Agilent, 5067-4626) and Qubit dsDNA HS Assay kit (Thermo Scientific ...
-
bioRxiv - Genomics 2023Quote: ... All library quantifications were performed on a Qubit 3.0 fluorometer with High Sensitivity DNA Quantitation Assay kit according manufacturer’s recommendations (Agilent, ThermoFisher Scientific, Q32851). All library validations were performed on a 2100 Bioanalyzer with High Sensitivity DNA kit according to manufacturer’s recommendations (Agilent Technologies ...
-
bioRxiv - Genomics 2023Quote: ... and library profiles were assessed using a High Sensitivity DNA kit on an Agilent Bioanalyzer (Agilent Technologies, Santa Clara, CA, USA). Libraries were then sequenced on an Illumina NovaSeq instrument (Illumina ...
-
bioRxiv - Cancer Biology 2023Quote: ... The quality and quantity of libraries were determined using Fragment Analyzer by DNF-474 High Sensitivity NGS Fragment Analysis Kit (Agilent Technologies) and QuantiFluor dsDNA System (Promega) ...
-
bioRxiv - Microbiology 2023Quote: ... Two μl of RNA samples was used for reverse transcription with the AccuScript High-Fidelity 1st Strand cDNA Synthesis Kit (Agilent; 200820) using random hexamer primers ...
-
bioRxiv - Microbiology 2023Quote: ... The purified libraries were then assessed for their fragment sizes using the High Sensitivity DNA kit on the Bioanalyzer 2100 (Agilent Technologies). After applying the NetoVIR protocol ...
-
bioRxiv - Cancer Biology 2023Quote: ... Single-cell RNA-seq and CMO libraries were prepared according to the manufacturer’s protocol and the library quality was confirmed with a Bioanalyzer High-Sensitivity DNA Kit (Agilent, 5067-4627). Cellecta barcode libraries were prepared using 25% of the adaptor-ligated cDNA to amplify only the barcoded cDNA product ...
-
bioRxiv - Molecular Biology 2023Quote: ... Quality control for the constructed library was performed by the Agilent Bioanalyzer High Sensitivity DNA Kit (Agilent Technologies; Catalog # 5067-4626), while Qubit DNA HS Assay Kit was used for qualitative and quantitative analysis ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... The quality of each library was assessed using a Bioanalyzer high sensitivity kit on an Agilent 2100 Bioanalyzer (Agilent 5067-4626). The libraries were submitted for sequencing at Cancer Research UK Cambridge Institute Genomic Core Facility using Illumina NovaSeq with 100bp single-end reads.
-
bioRxiv - Cell Biology 2023Quote: The NGS sample was diluted with TE buffer and assayed using a High Sensitivity DNA Kit (cat. #5067-4626, Agilent Technologies) on a Bioanalyzer 2100 ...
-
bioRxiv - Developmental Biology 2023Quote: ... GHTF assessed the quality and quantity of the amplified cDNA by electrophoresis using Agilent’s Agilent High Sensitivity DNA Kit (Agilent: 5067-4626) and Bioanalyzer before library construction ...
-
bioRxiv - Developmental Biology 2024Quote: ... Post cDNA amplification and post-library construction quality control was performed using the Agilent Bioanalyzer High Sensitivity kit (Agilent 5067–4626). Libraries were sequenced using a NovaSeq 6000 and the S2 flow cell ...
-
bioRxiv - Microbiology 2024Quote: ... The quality and quantity of each library was analyzed on the Bioanalyzer with a High Sensitivity DNA analysis Kit (Agilent technologies) and Collibri Library Quantification Kit (Invitrogen).
-
bioRxiv - Microbiology 2024Quote: ... The quality and quantity of each library was analyzed on the Bioanalyzer with a High Sensitivity DNA analysis Kit (Agilent technologies) and Collibri Library Quantification Kit (Invitrogen).
-
bioRxiv - Genomics 2024Quote: ... quality control was performed by run on an Agilent 2100 Bioanalyzer System using the High Sensitivity DNA Kit (Agilent, 5067-4626). Libraries were then created from each fraction using the NEBNext Ultra II DNA Library Prep Kit for Illumina (NEB ...
-
bioRxiv - Microbiology 2024Quote: ... Library pools concentrations were measured using Qubit dsDNA HS Assay Kit and the quality of the libraries was assessed by High Sensitivity D5000 ScreenTape (Agilent Technologies), followed by sequencing using Illumina NextSeq500.
-
bioRxiv - Cancer Biology 2024Quote: ... and the library quality check has been performed using a High Sensitivity NGS Fragment Analysis Kit on a Fragment Analyzer System (Agilent Technologies). Indexed libraries were normalized and pooled to be sequenced on an Illumina Novaseq 6000 sequencer according to manufacturer’s instructions with targeted conditions of 2 x 75bp and 25M reads/sample.
-
bioRxiv - Genomics 2019Quote: ... The sheared DNA was used to prepare indexed whole exome sequencing libraries using the Agilent SureSelect XT Human all exon v6 + UTR kit (Agilent Technologies ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Deletion and site-directed mutants were generated in human ENaC cDNAs cloned into a pGEM HE vector using the QuikChange II Site-Directed Mutagenesis kit (Stratagene) (Ji & Benos ...
-
bioRxiv - Genomics 2019Quote: ... or 100 ng of gDNA was assembled into exome sequencing libraries using the SureSelect Human All Exon V7 Exome kit (Agilent). DNA samples were pooled to achieve an on-bait depth of 100× for the buffy coat gDNA and 300× for the plasma cfDNA.
-
bioRxiv - Cancer Biology 2019Quote: ... Library preparation was performed using SureSelect Human All Exon Kit v5 (cat# 5990-9857EN, Agilent Technologies, Santa Clara, CA, USA), sequencing was performed on the Illumina Xten platform ...
-
bioRxiv - Cancer Biology 2020Quote: ... Exome regions were captured by an Agilent SureSelect Human All Exon V4 Kit and V5+ LincRNA (Agilent Technologies, CA, USA). Sequencing was performed on an Illumina HiSeq 2000 instrument (Illumina ...
-
bioRxiv - Neuroscience 2021Quote: Exonic sequences were enriched with the SureSelect Human All Exon 50□Mb V5 Kit (Agilent Technologies, Santa Clara, CA, USA). Sequences were generated on a HiSeq2500 (Illumina ...
-
bioRxiv - Cancer Biology 2020Quote: ... Kinase dead catalytically inactive versions of Drosophila and human RIOK2 (dRIOK2123A,246A, RIOK2123A,246A) were created using site directed mutagenesis (Lightning Quick Change Kit, Agilent) to make alanine substitutions at catalytic residues Lys-123 and Asp-246 in both human RIOK2 and dRIOK2 as described by other groups (22 ...
-
bioRxiv - Biochemistry 2021Quote: ... Mutations of the two Walker-A motifs in human ABCF1 (K324M, K664M) were created by using Quikchange II Site Directed Mutagenesis Kit (Agilent). Human ABCF1 and yeast GCN20 domain fusion cDNAs were created by PCR-mediated ligation and cloned into modified pMtac-His6 vector ...
-
bioRxiv - Cancer Biology 2022Quote: ... WES libraries were generated by exome capture of approximately 20,000 coding genes using SureSelect human All exon V6 kit (Agilent Technologies) and paired-end sequencing was performed on a HiSeq sequencer (Illumina ...
-
bioRxiv - Pathology 2022Quote: Exonic sequences were enriched in the DNA sample of patient II-6 using SureSelect Human All Exon 50 Mb Kit (Agilent Technologies ...
-
bioRxiv - Genetics 2021Quote: ... Partition barcoded libraries were then prepared based on the Chromium Exome Solution (10X Genomics) and the exome target regions was enriched by SureSelect Human All Exon V5 Kit (Agilent) according to the protocols ...
-
bioRxiv - Cell Biology 2019Quote: ... total leukocyte DNA was enriched using the Agilent SureSelect Human All Exon 50 Mb capture kit (Agilent Technologies, SantaClara, CA). Bidirectional 100-bp paired-end sequencing (Illumina Hi-Seq 2000 ...
-
bioRxiv - Biochemistry 2021Quote: ... The kinase domain c-Abl mutations were introduced into the human c-Abl kinase domain by site-directed mutagenesis using the QuikChange II kit (Agilent) and verified by DNA sequencing.
-
SMDT1 variants impair EMRE-mediated mitochondrial calcium uptake in patients with muscle involvementbioRxiv - Genetics 2022Quote: ... exome enrichment was performed using the SureSelect Human All Exon 50 Mb Kit V5 (Agilent Technologies, Santa Clara, CA, USA). Sequencing was done on a HiSeq4000 (Illumina ...