Labshake search
Citations for Phenomenex :
101 - 107 of 107 citations for Fmoc Rink Amide OctaGel Resin since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which had been previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Biochemistry 2023Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Microbiology 2024Quote: ... MudPIT columns were installed on the LC column switching valve and followed by a 20cm fused silica microcapillary analytical column packed with 3 µm Aqua C18 resin (Phenomenex, # 04A-4311) ending in a laser-pulled tip ...
-
bioRxiv - Cell Biology 2024Quote: Peptides were resuspended in 0.1% formic acid and injected into a custom-made 5 cm reversed- phase pre-column (inner diameter 100 µm, filled with 10 µm C18 Jupiter resins - Phenomenex, Torrance, California) connected to a nano HPLC system (NanoLC-1DPlus ...
-
bioRxiv - Biochemistry 2020Quote: Total peptides from TEV protease digestion for isoTOP-ABPP or tryptic peptides for mapping EN219 site of modification on pure RNF114 were pressure loaded onto 250 mm tubing packed with Aqua C18 reverse phase resin (Phenomenex no. 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Molecular Biology 2020Quote: ... Three µl of each sample was loaded onto a 30 cm fused silica 75 µm column and 3.5 cm 150 µm fused silica KASIL 1 frit trap (PQ Corporation, Malvern, PA, USA) loaded with 4 µm Jupiter C12 Proteo reverse-phase resin (Phenomenex, Torrance, CA, USA) and analyzed with Thermo Fisher Scientific EASY-nLC ...
-
bioRxiv - Microbiology 2023Quote: ... PF360-75-15-N-5, New Objective, 360 µm OD, 75 µm ID, 15 µm Tip PicoFrit Emitter; resin: 04A-4506, Phenomenex Aeris Peptide, C18 1.7 µm) via trapping column (column ...