Labshake search
Citations for Phenomenex :
51 - 100 of 107 citations for Fmoc Rink Amide OctaGel Resin since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2021Quote: ... The peptides were cleaved from the resin and purified via RP-HPLC (Phenomenex Luna Omega ...
-
bioRxiv - Molecular Biology 2021Quote: ... 2.3- to 2.5-cm 5 μm strong cation exchange resin (100 Å, Phenomenex) and again with 2.3- to 2.5-cm reversed-phase 5 μm Aqua C18 resin ...
-
bioRxiv - Cell Biology 2022Quote: ... The column was filled with 2.5 cm of reversed-phase 5 µm C18 resin (Phenomenex) followed by 2.5 cm of strong cation exchange resin ...
-
bioRxiv - Molecular Biology 2021Quote: ... followed by packing with at least 15-cm reversed-phase 3 μm Aqua C18 resin (Phenomenex). After further MeOH wash and Buffer A pre-equilibration ...
-
bioRxiv - Immunology 2022Quote: ... The eluted peptides were injected onto a 75um analytical column packed with Luna C18 resin (Phenomenex) and separated at a flow rate of 350nL/min ...
-
bioRxiv - Cell Biology 2023Quote: ... followed by packing with at least 15-cm reversed-phase 3 µm Aqua C18 resin (Phenomenex).
-
bioRxiv - Microbiology 2024Quote: Triphasic MuDPIT columns(83) were packed with 1.5cm Aqua 5 µm C18 resin (Phenomenex, #04A-4299), 1.5cm Luna 5 µm SCX resin (Phenomenex # 04A-4398) ...
-
bioRxiv - Molecular Biology 2021Quote: ... 25 cm column packed in-house with reversed-phase 3 µm Kinetex core-shell C18 resin (Phenomenex) at a flow rate of 400 nL/min at 40°C ...
-
bioRxiv - Biochemistry 2024Quote: ... the MudPIT column was packed with 1.5 cm of Aqua 5 µm C18 resin (Phenomenex # 04A-4299), 1.5 cm Luna 5 µm SCX resin (Phenomenex # 04A-4398) ...
-
bioRxiv - Cell Biology 2023Quote: ... and then packing with 2.5-cm-long reversed-phase 5 µm Aqua C18 resin (125 Å, Phenomenex). C18 loading columns were washed with MeOH and Buffer A prior to analysis ...
-
bioRxiv - Biophysics 2022Quote: ... Proteins were separated using a 5 cm x 0.5 mm column in-house packed with Jupiter 5μm C4 resin (Phenomenex). The ToF was set to scan at 1 s intervals and an analyzer setting of “Resolution” was used ...
-
bioRxiv - Microbiology 2021Quote: ... from each sample were suspended in solvent A (2% acetonitrile / 0.1% formic acid) and injected onto a C18 resin 75 μm microcapillary column (1.7 μm, 100Å, Phenomenex). Separation was accomplished at a constant flow rate of 250 nL/min with a 90-minute gradient from 2 to 30% solvent B (0.1% formic acid / 80% acetonitrile ...
-
bioRxiv - Molecular Biology 2021Quote: ... and then packing with 2.3- to 2.5-cm-long reversed-phase 5 μm Aqua C18 resin (125 Å, Phenomenex), 2.3- to 2.5-cm 5 μm strong cation exchange resin (100 Å ...
-
bioRxiv - Systems Biology 2021Quote: ... The trapping column (100 µm ID) was packed with 10 cm of 5 µm Kinetex C18 RP resin (Phenomenex) while the nanospray emitter (75 µm ID ...
-
bioRxiv - Cell Biology 2022Quote: ... two 1.0 mm Empore C18 filter plugs were added to a pipette tip and 2 mg 5μm C18 resin (Phenomenex) was added to the top of the C18 filter plug ...
-
bioRxiv - Synthetic Biology 2020Quote: ... Peptides were separated across a 180 min organic gradient using an in-house pulled nanospray emitter packed with 15 cm of 1.7-micron Kinetex reversed-phase resin (Phenomenex). Peptide fragmentation spectra were analyzed/sequenced by Proteome Discoverer software (Thermo Scientific ...
-
bioRxiv - Synthetic Biology 2020Quote: ... coupled to an in-house-pulled nanospray emitter of 75 μm inner diameter packed with 25 cm of 1.7 μm of Kinetex C18 resin (Phenomenex). For each sample ...
-
bioRxiv - Biochemistry 2020Quote: ... were loaded onto a triphasic column filled sequentially with 1.5 or 2.5 cm layers of 5 µm 100 Å C18 resin (Phenomenex), Luna 5 µm 100 Å strong cation exchange resin (Phenomenex ...
-
bioRxiv - Cell Biology 2021Quote: ... Peptide mixtures were loaded onto 250 μm fused silica microcapillary columns packed with strong cation exchange resin (Luna, Phenomenex) and 5-μm C18 reverse phase (Aqua ...
-
bioRxiv - Microbiology 2022Quote: ... outfitted with a 75 µm ID nanospray emitter packed with 15 cm Kinetex C18 resin (1.7 µm particle size; Phenomenex). Mobile phases included solvent A (95% H2O ...
-
bioRxiv - Systems Biology 2022Quote: ... were injected into a split-flow HPLC setup plumbed directly to an in-house pulled nanospray emitter packed with 15 cm of C18 resin (1.7 µm Kinetex C18 RP; Phenomenex) flowing at 300 nL/min ...
-
bioRxiv - Microbiology 2024Quote: ... 5 µL of supernatant was split-loaded onto an in-house pulled nanospray emitter (75 µm inner diameter) packed with 15 cm of C18 resin (1.7 µm Kinetex; Phenomenex) and separated over a 15 min reversed-phase gradient using a Vanquish HPLC interfaced directly to a Q Exactive Plus mass spectrometer (Thermo Scientific ...
-
bioRxiv - Plant Biology 2023Quote: ... a single 1µg injection of peptides were separated on an in-house-pulled nanospray emitter of 75μm inner diameter containing 25 cm of Kinetix C18 resin (1.7 µm, 100 Å, Phenomenex) across a linear organic gradient of 0–22% (80% acetonitrile ...
-
bioRxiv - Microbiology 2023Quote: ... 10 μL inject was flowed across an in-house made nanospray analytical column (75 μm X 150mm) packed with 1.7 μm C18 Kinetex RP C18 resin (Phenomenex). The mobile phase included Solvent A (95% water ...
-
bioRxiv - Plant Biology 2024Quote: ... with an integrated fritted emitter (15 µm; CoAnn Technologies) packed in-house with Kinetex C18-XB core shell 1.7 µm resin (Phenomenex). The analytical column was encased by a column oven (Sonation ...
-
bioRxiv - Genomics 2024Quote: ... with an in-house-pulled 100 µm inner diameter nanospray emitter (packed to 15 cm with 1.7 µm Kinetex C18 reverse-phase resin (Phenomenex)) ...
-
bioRxiv - Neuroscience 2020Quote: ... this biphasic column was connected to a 100 μm inner diameter-fused silica capillary (Polymicro Technologies) analytical column with a 3 μm pulled tip packed with 10 cm of 3 μm C18 resin (Phenomenex). The entire three-phase column was then laced in line with a 1,200 quaternary HPLC pump (Agilent Technologies ...
-
bioRxiv - Developmental Biology 2020Quote: ... [50,51] Peptide mixtures were loaded onto 250 μm fused silica microcapillary columns packed with strong cation exchange resin (Luna, Phenomenex) and 5-μm C18 reverse-phase (Aqua ...
-
bioRxiv - Cell Biology 2021Quote: ... self-packed with C-18 reverse-phase resin (Jupiter 5 um particles, 300 Å pore size; Phenomenex, Torrance, CA, USA) using a high- pressure packing cell on the Easy-nLC II system (Proxeon Biosystems ...
-
bioRxiv - Microbiology 2021Quote: ... Peptide samples were pressure loaded onto a 250-mm fused silica desalting column packed with 4 cm of Aqua C18 reverse phase resin (Phenomenex). Peptides were eluted onto a 100-mm fused silica biphasic column packed with 10 cm C18 resin and 4 cm Partisphere strong cation exchange resin (SCX ...
-
bioRxiv - Molecular Biology 2020Quote: ... Peptides were suspended in 0.1% formic acid and injected in an in-house made 5 cm reversed phase pre-column (inner diameter 100 µm, filled with a 10 µm C18 Jupiter resins-Phenomenex) coupled to a nano-HPLC (NanoLC-1DPlus ...
-
bioRxiv - Molecular Biology 2020Quote: ... The peptide fractionation was carried out on an in-house 10 cm reversed phase capillary emitter column (inner diameter 75 µm, filled with 5 µm C18 Aqua resins-Phenomenex) with a gradient of 2-35 % of acetonitrile in 0.1% formic acid for 52 min followed by a gradient of 35-95% for 5 min at a flow rate of 300 ml/min ...
-
bioRxiv - Microbiology 2021Quote: ... Azo digests were pressure loaded onto 250 μm fused silica desalting columns packed with 4 cm Aqua C18 reverse phase resin (Phenomenex). Peptides were then eluted onto a biphasic column consisting of 100 μm fused silica packed with 10 cm C18 and 4 cm PartiSphere SCX resin (Whatman ...
-
bioRxiv - Microbiology 2020Quote: ... 10% trifluoroacetic acid was added to the solution to bring the pH of the sample less than 2 before desalting and peptide isolation using Strata-X reverse phase resin (Phenomenex). Sample were dried under reduced pressure ...
-
bioRxiv - Molecular Biology 2021Quote: Peptides were loaded onto a 100-μm fused silica (Polymicro Technologies) capillary column packed with 3 cm of 5-μm reverse-phase C18 resin (Aqua; Phenomenex), 4 cm of 5-μm strong cation exchange resin (Luna ...
-
bioRxiv - Cell Biology 2022Quote: ... × 150 mm fused silica capillary packed in house with 4 μm 80 Å Synergi Hydro C18 resin (Phenomenex; Torrance, CA)) was then switched on-line at 600 nL/min for 10 min to load the sample ...
-
bioRxiv - Molecular Biology 2022Quote: ... × 150 mm fused silica capillary packed in house with 4 μm 80 Å Synergi Hydro C18 resin (Phenomenex; Torrance, CA)) was then switched online at 600 nL/min for 10 minutes to load the sample ...
-
bioRxiv - Microbiology 2024Quote: ... to separate peptides across an in-house pulled nanospray emitter analytical column (75 µm X 350 mm) packed with 35 cm of C18 Kinetex RP C18 resin (1.7 µm; Phenomenex, USA). Mass spectra were acquired with the Q Exactive Plus instrument in a top 10 data-dependent acquisition setup ...
-
bioRxiv - Physiology 2024Quote: ... Peptides were loaded on a trapping column and eluted over a 75 uM analytical column at 350 nL/min packed with Luna C18 resin (Phenomenex). The mass spectrometer was operated in a data dependent mode ...
-
bioRxiv - Plant Biology 2023Quote: ... which was then switched to be in-line with an in-house pulled nanospray emitter analytical column (75 μm X 350 mm) packed with Kinetex RP C18 resin (1.7 μm; Phenomenex, USA). Peptides were separated over a 160-minute linear gradient from 2 to 25% of mobile phase (0.1% FA ...
-
bioRxiv - Biochemistry 2023Quote: ... column (150 μm i.d.) packed in-house with Luna SCX resin (5 μm in particle size and 100 Å in pore size, Phenomenex) with buffer A (0.1% formic acid in water ...
-
bioRxiv - Systems Biology 2023Quote: ... The trapping column (100 µm ID) was packed with 6 cm of 5 µm Kinetex C18 reversed phase (RP) resin (Phenomenex), while the nanospray emitter (75 µm ID ...
-
bioRxiv - Biochemistry 2024Quote: Digested peptides from three biological replicates were resuspended in 0.1% formic acid and fractionated on an in-house reverse-phase capillary column (10 cm × 75 µm, filled with 5 µm particle diameter C18 Aqua resins-Phenomenex) coupled to nano-HPLC (NanoLC ...
-
bioRxiv - Cell Biology 2024Quote: ... Peptide fractionation was performed on a custom 10 cm reversed- phase capillary emitter column (inner diameter 75 µm, filled with 5 µm C18 Aqua resins - Phenomenex) using a gradient of 3–35% acetonitrile in 0.1% formic acid over 45 min ...
-
bioRxiv - Cell Biology 2021Quote: ... and separated on an analytical column (75 μM ID, 10 cm long, packed with Luna C18 3 μm 100 Å resin from Phenomenex) using an acetonitrile gradient from 0–8% in 100 min at a flow rate of 200 nl/min ...
-
bioRxiv - Biochemistry 2022Quote: ... before being loaded onto a capillary column (75 μm ID and 20 cm in length) in-house packed with Luna C18 resin (5 μm, 100 Å, Phenomenex). The peptides were separated with a linear gradient of 7% to 35% HPLC Buffer B (0.1% formic acid in 90% acetonitrile ...
-
bioRxiv - Biochemistry 2021Quote: ... and loaded onto a home-made capillary column (10 cm length with 75 μm ID) packed with Jupiter C12 resin (4 μm particle size, 90 Å pore size, Phenomenex) connected to an EASY-nLC 1000 HPLC system (Thermo Fisher Scientific) ...
-
bioRxiv - Biochemistry 2020Quote: ... 100 µm ID fused-silica microcapillary column with a laser-pulled tip filled with 3 µm 100 Å C18 resin (Phenomenex). Mass spectrometry was carried out on a Q-Exactive HF or an Exploris 480 instrument (ThermoFisher) ...
-
bioRxiv - Biochemistry 2022Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Cell Biology 2022Quote: ... Purified peptides were pressure-loaded onto a 250 mm silica capillary tubing filled with 4 cm of Aqua C18 reverse-phase resin (Phenomenex # 04A-4299). The samples were then attached using a MicroTee PEEK 360 µm fitting (Thermo Fisher Scientific #p-888 ...