Labshake search
Citations for Phenomenex :
451 - 500 of 1779 citations since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2024Quote: ... 3 μm particle size (Phenomenex, Torrance, CA)] column packed in-house in Pico-Frit (100 μm X 30 cm ...
-
bioRxiv - Biochemistry 2024Quote: ... 150 x 3 mm2 column (Phenomenex). Solvent A was water with 0.1% formic acid ...
-
bioRxiv - Cancer Biology 2024Quote: ... Samples were randomized then 10 μL of extracts were injected into a Thermo Vanquish UHPLC system (San Jose, CA, USA) and resolved on a Kinetex C18 column (150 × 2.1 mm, 1.7 μm, Phenomenex, Torrance, CA, USA) at 450 μL/min through a 5 min gradient from 0 to 100% B (mobile phases ...
-
bioRxiv - Biochemistry 2024Quote: ... Separation was carried out using a Gemini 5 μm NX-C18 110 Å column (2 × 100 mm; Phenomenex) with a mixture of 0.1% formic acid in water (A ...
-
bioRxiv - Biochemistry 2024Quote: ... These analytes were separated using a linear gradient of 15 min comprising 8 min from 3 % to 35 % of solution B (0.1 % formic acid / acetonitrile) and 2 min to 90 % of solution B on a reverse phase C4 column(0.3 x 20mm, Phenomenex, USA). The solution A was 0.1 % formic acid and the flow rate was at 5ul/min ...
-
bioRxiv - Cancer Biology 2024Quote: ... or a Waters Acquity UPLC system (equipped with a Gemini C18 column (150×21 mm, 5 µm particle size, Phenomenex) coupled to a SQ mass spectrometer) ...
-
bioRxiv - Cancer Biology 2024Quote: ... purifications were performed on either an Agilent 1200 preparative HPLC system (equipped with a Gemini C18 column (250×10 mm, 5 µm particle size, Phenomenex) coupled to a 6130 quadrupole mass spectrometer ...
-
bioRxiv - Biochemistry 2024Quote: ... purified by HPLC on a semi-preparative column (Phenomenex Luna 5 μm C18 column (150 mm × 10 mm) and re-lyophilized ...
-
bioRxiv - Biochemistry 2024Quote: ... connected to a guard column of similar specificity (20 × 2.1 mm, 3 μm particle size; Phenomenex, Torrance, California, USA) at a constant flow rate of 0.2 ml min-1 with mobile phase A being 0.1% formic acid in water and phase B being 0.1% formic acid in methanol at 40°C ...
-
bioRxiv - Cancer Biology 2024Quote: ... Extracts were separated by a Synergi Hydro-RP column (2.0×100 mm, 2.5 μm, Phenomenex) with a flow rate of 0.5 mL min-1 ...
-
bioRxiv - Bioengineering 2024Quote: ... A total of four methods was applied to each sample using either a hydrophilic interaction chromatography (HILIC) column (Phenomenex Luna NH2, Torrance, CA, USA) or a reverse-phase column (Phenomenex Synergi Hydro-RP ...
-
bioRxiv - Bioengineering 2024Quote: ... or a reverse-phase column (Phenomenex Synergi Hydro-RP, Torrance, CA, USA) in both positive and negative ionization modes ...
-
bioRxiv - Biochemistry 2024Quote: The chromatographic separation was carried out on a Luna Omega polar C18 (2.1mm × 150 mm, 1.6 μm, Phenomenex, Torrance, CA, USA) at 30 °C with a flow elution rate of 400 μL/min ...
-
bioRxiv - Biochemistry 2024Quote: ... at the flow rate of 0.04 mL/min or Yarra 3μm SEC-2000 at the flow rate of 0.5 mL/min (Phenomenex #00H-4512-K0) using Thermo Vanquish UHPLC.
-
bioRxiv - Cancer Biology 2024Quote: ... 4 μm column (Phenomenex, Torrance, USA) and HPLC Prominence coupled LCMS-IT-TOF (Shimadzu ...
-
bioRxiv - Cancer Biology 2024Quote: ... Ten µl was injected and separation was achieved with a C18 column (Kinetex 2.6 µm EVO C18 100×4.6 mm, Phenomenex). The chromatography gradient started with 5 min 5 % acetonitrile in water ...
-
bioRxiv - Cancer Biology 2024Quote: ... Samples were randomized then 10μL of extracts were injected into a Thermo Vanquish UHPLC system (San Jose, CA, USA) and resolved on a Kinetex C18 column (150 × 2.1 mm, 1.7 μm, Phenomenex, Torrance, CA, USA) at 450μL/min through a 5 min gradient from 0 to 100% B (mobile phases ...
-
bioRxiv - Cancer Biology 2024Quote: ... and a one-tenth aliquot was loaded onto a Luna 3-µm NH2 100A (150 × 2.0 mm) column (Phenomenex, Torrance, CA, USA). The chromatographic separation was performed on an UltiMate 3000 RSLC (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... × cm pulled-tip C-18 column (Jupiter C18 300 Å, 5 microns, Phenomenex). We used a Thermo Q Exactive HF-X mass spectrometer equipped with a Nanospray Flex ion source (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... A Zorbax C18 column (4,6 x 250 mm x 5 µm, Phenomenex) kept at 25°C was employed ...
-
bioRxiv - Cancer Biology 2024Quote: ... Dried metabolites were resuspended in 100 µl 50% ACN:water and 5 µl was loaded onto a Luna 3µm NH2 100A (150 × 2.0 mm) column (Phenomenex). The chromatographic separation was performed on a Vanquish Flex (Thermo Scientific ...
-
bioRxiv - Cancer Biology 2024Quote: ... with Luna 5 μm C18 (2) 100 Å media (Phenomenex, Torrance, CA). The samples were eluted at a flow rate of 0.25 uL/min with a gradient of 0.1% FA in water (Solvent A ...
-
bioRxiv - Cancer Biology 2024Quote: ... Samples were injected on to a Securityguard C18 pre-column (Phenomenex, Utrecht, The Netherlands) connected to a ZORBAX Extend-C18 column (Agilent ...
-
bioRxiv - Developmental Biology 2024Quote: ... and normal phase chromatography was performed using a silica column (150x2 mm, Luna Silica 5 µm, Phenomenex). The mobile phase system consisted of solvent A (isopropanol/hexane/water (58/40/2 ...
-
bioRxiv - Developmental Biology 2024Quote: ... equipped with a Gemini C18 column (3 μm, 110 Å, 100 x 1.0 mm, Phenomenex) (Reichel ...
-
bioRxiv - Developmental Biology 2024Quote: ... HPLC was conducted at 40 ° C using a Kinetex C18 column (100 × 4.60 mm) with 2.6 mm particle size and 100 Å pore size (Phenomenex). The following solvents were used ...
-
bioRxiv - Cell Biology 2024Quote: ... with a Gemini NX C18 Security Guard Cartridge (4.0 × 3.0 mm) (Phenomenex, AJ0-8368). Mobile phase A consisted of 2.8% acetonitrile ...
-
bioRxiv - Cell Biology 2024Quote: ... HILIC chromatography was performed using a Luna 3u HILIC 200A column (150 × 2.0 mm, 3 µm particle size, Phenomenex). The mobile phase consisted of solvent A (10 mM ammonium formate ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... and separated using a 0.075 mm × 250 mm bioZen 2.6 µm Peptide XB-C18 RP column (Phenomenex) at 0.25 μl/min ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... Jupiter C18 bonded particles (Phenomenex, Torrence, CA). Separations were performed at a flow rate of 2.2 µL/min on binary pump systems ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... The trapping column was slurry packed in-house using Jupiter 5um C18 particles (Phenomenex, Torrence, CA) into a 4cm long piece of 360um od x 150um id fused silica (Polymicro Technologies ...
-
bioRxiv - Cell Biology 2024Quote: ... Dried metabolites were resuspended in 100 ul 50% ACN:water and 5 ul was loaded onto a Luna NH2 3um 100A (150 × 2.0 mm) column (Phenomenex) using a Vanquish Flex UPLC (Thermo Scientific) ...
-
bioRxiv - Cell Biology 2024Quote: ... A portion of the hit fraction (0.48 mg) was subjected to RP-HPLC (Phenomenex, Luna 5u C18(2) 100A ...
-
bioRxiv - Cell Biology 2024Quote: ... A portion of this fraction (16 mg) was subjected to RP-HPLC (Phenomenex Luna 5 μm C18(2), φ10 x 250 mm ...
-
bioRxiv - Biochemistry 2024Quote: ... C18 beads (Phenomenex, Jupiter). Peptides were loaded on-column at a flowrate of 2 µL/min for 15 min and then eluted over 40 min at a flowrate of 2 µL/min with a gradient of 0% to 70% acetonitrile in 20mM ammonium formate ...
-
bioRxiv - Cell Biology 2024Quote: ... 1.7 µm particle (Phenomenex) column at 35 °C ...
-
bioRxiv - Molecular Biology 2023Quote: ... Digested peptides were loaded onto a Luna Micro C18 trap column (20-x 0.30 mm, 5-µm particle size; Phenomenex, Torrance, CA) over 2 min at 10 µL/min with 100% solvent A ...
-
bioRxiv - Molecular Biology 2023Quote: ... Peptides were eluted onto a Kinetex XB-C18 analytical column (150 x 0.30 mm, 2.6-µm particle size; Phenomenex) at 5 µL/min using a 120- ...
-
bioRxiv - Molecular Biology 2023Quote: ... 0.1% FA in H2O and then separated on a BioZen peptide XB-C18 nano-column (75 μm ID x 25 cm, 2.6 μm, Phenomenex) at 350 nl/min and 45°C with a 60 min linear gradient from 9% to 30% buffer B (A ...
-
bioRxiv - Neuroscience 2023Quote: ... Allopregnanolone was separated from interferents using a Luna 5u C8(2) 50×2 mm column (Phenomenex) kept at 35 °C using a column oven ...
-
bioRxiv - Microbiology 2023Quote: ... Zn-PPIX was purified by RP-HPLC over a C18 solid phase (Phenomenex) with isocratic acetone:MeOH:water:formic acid (280:120:100:1 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... to 2/98% over 2:50 min:sec on a Luna™ 5 µm C18 50x2.0 mm 100 A column (Phenomenex, Aschaffenburg, Germany). For MS/MS analyses in the positive electrospray ionisation mode on a Varian 1200 TSQ (Agilent Technologies ...
-
bioRxiv - Microbiology 2023Quote: ... digested samples were loaded onto a fused silica capillary column with a 5-μm electrospray tip and packed in house with 18 cm of Luna C18 3 μM particles (Phenomenex). The column was then placed in line with a Q-exactive mass spectrometer (ThermoFisher ...
-
bioRxiv - Microbiology 2023Quote: ... muropeptides were separated using an UPLC system (Waters) equipped with a trapping cartridge precolumn (SecurityGuard ULTRA Cartridge UHPLC C18 2.1 mm, Phenomenex) and an analytical column (Waters ACQUITY UPLC BEH C18 ...
-
bioRxiv - Plant Biology 2023Quote: ... A 100 × 2.1 mm 2.6μ Kinetex EVO column (Phenomenex) was used for separation using an acetonitrile versus 1% (v/v ...
-
bioRxiv - Plant Biology 2023Quote: ... Separation was achieved on a Lux® 3 μm AMP column (150 x 3.0 mm, Phenomenex, Torrance, USA) with an eluent flow rate of 0.3 mL/min and a column temperature of 40°C ...
-
bioRxiv - Plant Biology 2023Quote: ... Compounds were separated on a Kinetex® 1.7 μm EVO C18 100 Å column (100 x 2.1 mm, Phenomenex, Torrance, USA) applying an eluent flow rate of 0.3 mL/min and a column temperature of 40°C ...
-
bioRxiv - Zoology 2023Quote: ... on a polar analytical column (ZB5-5MS; 60m length, 0.32mm diameter, 0.25μm film thickness; Phenomenex, USA).
-
bioRxiv - Zoology 2023Quote: ... The FAMEs from feces and gut content were separated on a ZB5-5MS column (60 m length, 0.32 mm diameter, 0.25 μm film thickness; Phenomenex, USA) on the same GC ...
-
bioRxiv - Plant Biology 2023Quote: ... dsGLS were analyzed by LC-MS/MS on an Advance UHPLC system (Bruker, Bremen, Germany) equipped with a Kinetex® XB-C18 column (100 × 2.1 mm, 1.7 μm, 100 Å, Phenomenex, USA) coupled to an EVOQ Elite TripleQuad mass spectrometer (Bruker ...