Labshake search
Citations for Phenomenex :
701 - 750 of 1749 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... SeGlcNAc-mBBr was purified by semi-preparative HPLC using a Luna C18 column (Phenomenex, 250 × 10 mm, 5 µm) with a flow rate of 2.5 mL/min and elution consisting of a gradient of 10–50% solvent B for 10 min ...
-
bioRxiv - Biochemistry 2022Quote: ... Reactions quenched with mBBr were filtered and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and an elution program consisting of a 5% solvent B wash for 3 min ...
-
bioRxiv - Biochemistry 2022Quote: ... and analyzed by LC-MS using a Synergi Hydro-RP column (Phenomenex, 250 × 4.6 mm, 4 µm) with a flow rate of 1 mL/min and an elution program gradient consisting of a 0% solvent B wash for 3 min ...
-
bioRxiv - Cell Biology 2022Quote: ... two 1.0 mm Empore C18 filter plugs were added to a pipette tip and 2 mg 5μm C18 resin (Phenomenex) was added to the top of the C18 filter plug ...
-
bioRxiv - Immunology 2022Quote: ... A Kinetex Pentafluorophenyl (PFP) column (50 × 2.1mm, 1.7µM, Phenomenex) was used for the separation of 25-OHC and 7α,25-OHC from other oxysterols ...
-
bioRxiv - Microbiology 2022Quote: ... and injected onto a nanoACQUITY UPLC (Waters) equipped with a self-packed Aeris 3.6 μm C18 analytical column (20 cm x 75 μm; Phenomenex). Peptides were eluted using standard reverse-phase gradients ...
-
bioRxiv - Molecular Biology 2022Quote: ... For separation a Core-Shell Technology column (Synergi, 2.5 μm Fusion-RP, 100 Å, 100 × 2 mm column, Phenomenex, Torrance, CA, USA) at 35 °C and a flow rate of 0.35 mL/min were used in combination with a binary mobile phase of 5 mM NH4OAc aqueous buffer A ...
-
bioRxiv - Cancer Biology 2022Quote: ... peptides were desalted using Strata X C18 SPE columns (Phenomenex) and reconstituted in 0.5 M TEAB ...
-
bioRxiv - Cancer Biology 2022Quote: ... Gas chromatograph was equipped with a 30 m (I.D. 250 μm, film 0.25 μm) ZB-35MS capillary column with 5 m guard column (Phenomenex). Helium was used as carrier gas with a constant flow rate of 1.2 ml/min ...
-
bioRxiv - Cancer Biology 2022Quote: ... sample clean-up was performed by solid phase extraction (SPE strata-X-C, Phenomenex). The labelling schemes per sets can be found in Tables SM1A ...
-
bioRxiv - Cancer Biology 2022Quote: ... after sample clean-up by solid phase extraction (SPE strata-X-C, Phenomenex), the sample pool was subjected to peptide IEF-IPG (isoelectric focusing by immobilized pH gradient ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... 50 x 2.1 mm analytical column (Phenomenex, Torrance, CA USA) using gradient separation ...
-
bioRxiv - Biochemistry 2022Quote: ... Sample separation occurred on a Kinetiex EVO C18 2.6 µM (2.1 × 50 mm column, Phenomenex) with a 0-8% gradient of acetronitrile with 100 mM ammonium bicarbonate as the solvent ...
-
bioRxiv - Biochemistry 2022Quote: ... Selenoneine-mBBr (SEN-mBBr) was purified by semi-preparative HPLC using a Luna C18 column (Phenomenex, 250 × 10 mm, 5 µm) with a flow rate of 2.5 mL/min and an elution program consisting of a gradient of 7.5–80% solvent B for 12 min ...
-
bioRxiv - Biochemistry 2022Quote: ... Analytes were separated on a Synergi Fusion-RP column (Phenomenex, 100 × 4.6 mm, 4 µm) with a flow rate of 0.5 mL/min and an elution program consisting of 0% solvent B wash for 5 min ...
-
bioRxiv - Biochemistry 2022Quote: ... For sample clean-up solid phase extraction using SPE strata-X-C columns (Phenomenex, Torrance, CA, USA) was performed ...
-
bioRxiv - Biochemistry 2022Quote: Peptides from all chemoproteomic experiments were pressure-loaded onto a 250 μm inner diameter fused silica capillary tubing packed with 4 cm of Aqua C18 reverse-phase resin (Phenomenex, 04A-4299), which was previously equilibrated on an Agilent 600 series high-performance liquid chromatograph using the gradient from 100% buffer A to 100% buffer B over 10 min ...
-
bioRxiv - Biochemistry 2022Quote: ... Peptides were purified by reversed-phase high-performance liquid chromatography on a C4 column (Phenomenex Jupiter C4, 5 μm, 300 Å, 250 × 10 mm) using a gradient of acetonitrile/water containing 0.1% TFA ...
-
bioRxiv - Biochemistry 2022Quote: ... Proteins were separated on an Aeris Widepore C4 column (3.6 μm particle size, dimensions 2.1 x 150 mm, Phenomenex) with a working temperature of 55 °C ...
-
bioRxiv - Cancer Biology 2022Quote: ... Gas chromatograph was equipped with a 30 m (I.D. 250 μm, film 0.25 μm) ZB-35MS capillary column with 5 m guard column (Phenomenex). Helium was used as carrier gas with a constant flow rate of 1.2 ml/min ...
-
bioRxiv - Pathology 2022Quote: ... 360µm OD x 100µm ID fused silica tip packed with Aeris Peptide 3.6µm XB-C18 100Å material (Phenomenex, Torrance, CA, USA). Peptides were eluted under a 90min 2%-44% acetonitrile gradient and transferred by Nanospray Flex nanoelectrospray source (ThermoFisher ...
-
bioRxiv - Biochemistry 2022Quote: ... Neutral lipids were quantified by HPLC equipped with an ELSD (Evaporative Light Scattering Detector) using a cyanopropyl column (Luna 5 μm CN 100Å 250 x 4.6 mm; Phenomenex) with hexane as mobile phase A and methyl tertiary-butyl ether (MTBE):isopropanol (95:5 v/v ...
-
bioRxiv - Neuroscience 2022Quote: ... Processed samples were separated using a 100 x 4.6 mm Kinetex (C18 5 μm 100 Å, Phenomenex) column on a reverse-phase HPLC system with a BAS LC-4B electrochemical detector with dual 3mm carbon electrode (MF-1000 ...
-
bioRxiv - Molecular Biology 2022Quote: ... the soluble muropeptides of each sample were separated by reverse-phase high-performance liquid chromatography (RP-HPLC) on a Kinetex C18 Column (1.7 μm, 100 Å, 150 × 2.1 mm, Phenomenex) coupled to an LXQ mass spectrometer (MS ...
-
bioRxiv - Neuroscience 2022Quote: ... with pre-slit caps (Phenomenex, Torrance, CA, USA; Cat #AR0-8972-13-B) and inserts (Waters Corporation ...
-
bioRxiv - Neuroscience 2022Quote: ... The filtered samples were transferred into 2 mL amber LC-MS vials (Phenomenex, Torrance, CA, USA; Cat #AR0-3911-13) with pre-slit caps (Phenomenex ...
-
bioRxiv - Neuroscience 2022Quote: ... 45 µL of supernatant containing extracted metabolites was mixed with 5 µL 0.5 M Potassium Phosphate buffer and quantified by HPLC (Nexera X2) on a Kinetex (100 × 3 mm, 2.6 µm; Phenomenex) column ...
-
bioRxiv - Neuroscience 2022Quote: ... Neurotransmitters and their metabolites were separated on a Luna 100 × 3.0 mm C18 3 μm HPLC reversed-phase column (Phenomenex). The mobile phase consisted of 75 mM NaH2PO4 ...
-
bioRxiv - Systems Biology 2022Quote: ... equipped with a refractive index detector using a Rezex ROA Organic Acid H+ (8%) column (Phenomenex Inc. Germany). The column was eluted with 0.005 N of H2SO4 at a flow rate of 0.6 mL/min at 50°C65 ...
-
bioRxiv - Systems Biology 2022Quote: ... glucose and fructose were analyzed using RCM Monosaccharide Ca2+ column (Phenomenex Inc., Germany). The column was eluted with deionized water at a flow rate of 0.6 mL/min at 80°C66 ...
-
bioRxiv - Microbiology 2022Quote: ... Kinetex C8 (Phenomenex) reversed-phase column (particle size 2.6 μm ...
-
bioRxiv - Synthetic Biology 2022Quote: ... equipped with Rezex™ ROA-Organic Acid H+ (8%) column (Phenomenex Inc., Torrance, CA) and a refractive index detector (RID) ...
-
bioRxiv - Synthetic Biology 2022Quote: ... equipped with ESI positive ion mode (Bruker, Amazon SL Ion Trap) and a Kinetex 2.6-μm XB-C18 100 Å (Phenomenex). (2 ...
-
bioRxiv - Synthetic Biology 2022Quote: ... samples (soil and liquid culture) were added to 2 mL gas-tight vials (AR0-37L0-13, Phenomenex) and crimped with VEREX tops (AR0-5710-13 ...
-
bioRxiv - Synthetic Biology 2022Quote: ... Gas tight vials (2 mL) were from Phenomenex, and gas sample canisters were from LabCommerce.
-
bioRxiv - Synthetic Biology 2022Quote: ... and crimped with VEREX tops (AR0-5710-13, Phenomenex). After incubation ...
-
bioRxiv - Systems Biology 2022Quote: ... a reverse phase (Kinetex C18 column 2.1 x 150 mm, 1.7 μm; Phenomenex, Torrance, CA, USA)[23] was used at room temperature using 50 mM ammonium acetate pH 5.0 as mobile phase A ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The separation was done at 40 °C in a C18 column (Kinetex 2.6 μm C18 100 Å, 100 × 4.6 mm, Phenomenex, Torrance, USA) using isocratic elution for 10 min using acetone:water (70:30 ...
-
bioRxiv - Systems Biology 2022Quote: ... Organic acids and alcohols were analysed by HPLC (Shimadzu Prominence-I LC-2030 plus system) using a Rezex™ ROA-Organic Acids H+ (8%) 300 × 7.8 mm column (00H-0138-K0; Phenomenex) and a guard column (03B-0138-K0 ...
-
bioRxiv - Systems Biology 2022Quote: ... and a guard column (03B-0138-K0; Phenomenex). Twenty microlitres of the sample were injected using an auto-sampler and eluted isocratically with 0.5 mM H2SO4 at 0.6 mL/min for 30 min at 45°C ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Buffer was run at a flow rate of 0.6 mL/minute through a C8 column (Exlipse XDB-C8, 3 μm, 3.0×100 mm, Phenomenex). Dexamethasone was detected using UV absorbance at 240 nm and the assay had a linear range of 1.56 – 100 μg/mL (Supplemental Figure 14) ...
-
bioRxiv - Neuroscience 2022Quote: ... a 5 μm particle size C18 column (100×46 mm, Kinetex EVO, Phenomenex) and a Waters 2465 amperometric detector set at an oxidation potential of 0.75 V ...
-
bioRxiv - Neuroscience 2022Quote: ... Standards and synaptosome extracts (20 µl each) were injected onto a Luna NH₂ column (3 µm, 2.0 mm × 150 mm) (Phenomenex, Australia) maintained at room temperature ...
-
bioRxiv - Molecular Biology 2022Quote: ... a C18 reverse HPLC column (SynergiTM 4 µM particle size, 80 Å pore size, 250 × 2.0 mm; Phenomenex) was used ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 150 × 2 mm; Phenomenex, Torrence, CA), guard column (BDS-Hypersil-C18 ...
-
bioRxiv - Neuroscience 2022Quote: ... A Luna C18(2) LC Column (3 µm particle size, 100 Å, 50 × 1 mm; Phenomenex, Torrence, CA) and SenCell (2 mm glassy carbon electrode ...
-
bioRxiv - Microbiology 2022Quote: ... with a Kinetex C18 biphenyl column (2.6 um 50 x 3 mm Phenomenex) at 45°C with 98% MS-grade water (Sigma-Aldrich) ...
-
bioRxiv - Cell Biology 2022Quote: ... Purified peptides were pressure-loaded onto a 250 mm silica capillary tubing filled with 4 cm of Aqua C18 reverse-phase resin (Phenomenex # 04A-4299). The samples were then attached using a MicroTee PEEK 360 µm fitting (Thermo Fisher Scientific #p-888 ...
-
bioRxiv - Microbiology 2022Quote: ... at room temperature on a Shimadzu LC-10 HPLC system using a semi-preparative C18 Jupiter column (10 mm; 300A; 10 × 250 mm) (Phenomenex International, Torrance, CA, USA) equilibrated at room temperature with 0.05% TFA in ultrapure water ...
-
bioRxiv - Microbiology 2022Quote: ... Ten μL of each sample were automatically injected on a C18 pre-column (100 mm I.D. × 50 mm; Jupiter 10 mm, Phenomenex Inc., Torrance, California, USA) coupled to a C18 analytical column (75 mm I.D ...