Labshake search
Citations for Molecular Devices :
351 - 400 of 457 citations for 5 tert Butyl 3 isocyanatoisoxazole since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Pathology 2020Quote: ... and incubated at room temperature for 10 min before reading in a FlexStation 3 Benchtop Multi-Mode Microplate Reader (Molecular Devices, San Jose, California) (250-ms integration).
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were done by impaling body-wall muscle 6-7 in abdominal segment 3 with a 20-25 MÙ electrode and were amplified using an Axoclamp 900A amplifier (Molecular Devices, San Jose, CA). Recordings were exported to a computer using an Axon Digidata 1550B (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell patch recordings from pyramidal neurons (PyNs) in layer 2/3 of the medial prefrontal cortex (mPFC) were performed using Axopatch 700B amplifiers (Molecular Devices, Union City, CA). Slices were visualized using an Olympus Bx51 microscope equipped with infrared-differential interference contrast optics (IR-DIC ...
-
bioRxiv - Molecular Biology 2024Quote: ... luciferase detection reagent was added to each well 10 min prior to luminescent determination with a FlexStation 3 Multimode Microplate Reader (Molecular Devices, San Jose, CA). In the absence of a known MNRR1-inducing small molecule ...
-
bioRxiv - Cell Biology 2022Quote: ... CM-DCF fluorescence inside cells was measured at 485 nm for excitation and 538 nm for emission with FlexStation® 3 Multi-Mode Microplate Reader (Molecular Devices, Sunnyvale, CA, USA). The amount of emitted fluorescence was correlated to the quantity of reactive oxygen species (ROS) ...
-
bioRxiv - Bioengineering 2022Quote: ... was normalized to bacterial growth using optical density measured as absorbance at 600 nm (OD600) on a plate reader (Spectra Max 3, Molecular Devices, San Jose, CA, USA). Bioluminescent signals were quantified using the 8x12 grid ROI for all wells (in vitro thermocycler induction ...
-
bioRxiv - Microbiology 2021Quote: ... The plates were then incubated for 3 min at room temperature and the luminescence was assessed using a plate luminometer (Molecular Devices, San Jose, CA, USA) with 1 sec integration time ...
-
bioRxiv - Neuroscience 2022Quote: ... Cells were loaded with GloSensor™ cAMP reagent (2mM) for 1-2 hours at 37°C and luminescence monitored using a Flexstation 3 (Molecular Devices, San Jose, USA) at 25°C ...
-
bioRxiv - Plant Biology 2023Quote: ... The plate was cooled for 3 min at room temperature before measuring the absorbance with a SpectroMax M5 UV/Vis spectrophotometer (Molecular Devices, San Jose, CA, USA) at 630 nm ...
-
bioRxiv - Plant Biology 2024Quote: ... LUC signals were measured using the Dual-Luciferase Reporter Assay Kit (Vazyme, Nanjing, China) and analyzed on a FlexStation 3 Multi-Mode Microplate Reader (Molecular Devices, San Jose, CA, USA). Relative luciferase activity was calculated based on LUC:REN ratios.
-
bioRxiv - Neuroscience 2021Quote: ... digitized at 10–20 kHz and low-pass filtered at 2–5 kHz with a Digidata 1440A analog-to-digital converter and analyzed off-line using Clampfit 10.7 software (Molecular Devices). Intrinsic excitability was determined in response to increasing depolarizing current pulses (+75 pA ...
-
bioRxiv - Biochemistry 2020Quote: ... Fluorescence intensity measurements were collected every 30 sec on a SpectraMax M5 fluorometer using Softmax Pro 5 software (Molecular Devices; excitation and emission set to 410 nm and 490 nm ...
-
bioRxiv - Neuroscience 2020Quote: ... The steady-state voltage responses were plotted against the amplitude of current injection and the slope of the linear fit between −5 pA to −30 pA was used to define Rin (Clampfit v. 11.1; Molecular Devices). Time constant (tau ...
-
bioRxiv - Microbiology 2021Quote: ... incubating 1 hour at 37ºC 5% CO2 and measuring fluorescence (λEX = 540 nm, λEM = 590 nm) on a SpectraMax M5 (Molecular Devices). The IC50 was calculated using GraphPhad Prism 9 using a non-linear regression analysis ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... was added and plates were gently shaken for 5 s to mix and then absorbance (O.D.) was measured at 450/620 nm on a SpectraMax M5 (Molecular Devices) instrument and data were processed by SoftMax Pro 6.4 software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2021Quote: ... the data acquired at 5 kHz with a Digidata 1440A (Axon instruments) interface using pCLAMP 10 acquisition software (Molecular Devices). The Internal and external (bath ...
-
bioRxiv - Physiology 2021Quote: ... Currents were filtered at 1 kHz and digitized at 5 kHz using an Axopatch 200B amplifier and Clampex 10.4 (Molecular Devices. Offline analysis was performed using Clampfit 10.4 ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were filtered at 5-10 kHz and digitized at 50 kHz using an acquisition board (Digidata 1440, Molecular Devices) attached to a personal computer running pCLAMP 10.2 software package (Molecular Devices) ...
-
bioRxiv - Immunology 2021Quote: ... DAF fluorescence intensities were measured every 5 minutes for a total of 60 minutes using a SpectraMax iD3 (Molecular Devices). All experiments were repeated at least four times per batch.
-
bioRxiv - Neuroscience 2022Quote: ... digitized at 5-20 kHz and acquired using a Digidata 1440A digitizer and pClamp 10 software (all from Molecular Devices).
-
bioRxiv - Molecular Biology 2022Quote: ... filtered at 2 kHz and digitized at 5 kHz using Digidata 1440A interface with pClamp 10 software (Molecular Devices Corporation). Series resistance was typically 5–20 MΩ ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrophysiological recordings were obtained from one neuron per slice and 4-5 slices per mouse using a Multiclamp 700B amplifier and analyzed using a digital system (pClamp version 11.2, Molecular Devices). Series and input resistances were monitored throughout the experiment using a -5 mV pulse ...
-
bioRxiv - Neuroscience 2024Quote: Currents were filtered at 5 kHz using low-pass Bessel filter of the amplifier and digitized using a Digitata 1,440 unit (Molecular Devices). All voltage clamp measurements were performed at a holding voltage of -60 mV ...
-
bioRxiv - Neuroscience 2024Quote: ... were plotted against the amplitude of current injection and the slope of the linear fit between −5 pA to −30 pA was used to define Rin (Clampfit v. 11.2; Molecular Devices). Time constant (tau ...
-
bioRxiv - Systems Biology 2022Quote: ... and the EtBr accumulation was measured by measuring the fluorescence in a microplate reader (spectramax multimode M 5, Molecular devices) at 37°C using 530 nm excitation wavelength and 585 nm as the emission wavelength ...
-
bioRxiv - Biochemistry 2023Quote: ... Data were sampled at 10 kHz and filtered at 5 kHz using a Digidata 1550A device controlled by pCLAMP 10.5 (Molecular Devices). Capacitance transients and leak currents were removed by subtracting a scaled control trace utilizing a P/4 protocol.
-
bioRxiv - Cancer Biology 2023Quote: ... Whole-cell currents were filtered at 5 kHz and digitized at 10 kHz using the software pCLAMP 10 (Molecular Devices). Micropipettes were pulled from Corning 8161 capillary glass tubes (Warner Instruments ...
-
bioRxiv - Neuroscience 2023Quote: Spontaneous IPSCs were detected and analyzed for 5-minute epochs during baseline and following drug exposure (Clampfit 11.1, Molecular Devices). For electrically-evoked IPSCs ...
-
bioRxiv - Neuroscience 2024Quote: ... Continuous current traces of 5-min duration (recorded at least 5 min after achieving whole-cell configuration) were acquired and analyzed with Clampfit 10.7 (Molecular Devices). The frequency and amplitude of recorded sIPSCs were quantified.
-
bioRxiv - Neuroscience 2024Quote: ... We detected the evoked qEPSCs 0.5-1.5s after the light onset and calculated the average number of qEPSCs from 5 sweeps using Clampfit 11 (Molecular Devices).
-
bioRxiv - Neuroscience 2020Quote: Membrane currents from voltage-clamp electrophysiology experiments were amplified and low-pass filtered at 5 kHz using a MultiClamp 700B amplifier (Molecular Devices), digitized at 10 kHz and acquired using a Digidata 1550A digitizer (Molecular Devices) ...
-
bioRxiv - Cell Biology 2020Quote: ... were acquired at 20–100 kHz and filtered at 5–10 kHz (low-pass Bessel filter) using a computer attached to a DigiData 1200 (Molecular Devices). Patch pipettes were pulled from borosilicate glass (Kimble® Queretaro ...
-
bioRxiv - Molecular Biology 2021Quote: ... Cells were transfected in glass bottom 96 well plates (3-5 replicate wells per treatment) followed by imaging using a Zeiss Axioskop-2 microscope or an ImageXpress Micro Confocal (Molecular Devices) using a 20X objective (S Plan Fluor ...
-
bioRxiv - Cancer Biology 2022Quote: ... Blood samples were centrifuged to obtain plasma (300g for 5 min at room temperature) and OG fluorescence was read with a plate reader (FlexStation II Molecular Devices) at 480nm excitation/520nm emission.
-
bioRxiv - Neuroscience 2021Quote: ... 5-minute traces were recorded and mEPSCs events were detected using a template matching built-in feature in Clampfit (Molecular devices).
-
bioRxiv - Biophysics 2022Quote: ... The data was passed through a low-pass filter (1 kHz cutoff frequency) and stored in PC using an analog-to-digital converter (5 kHz sampling; Digidata 1550A; Molecular Devices) and pCLAMP software (Molecular Devices).
-
bioRxiv - Immunology 2021Quote: ... cells were lysed using a previously described assay buffer (109) and shaken for 5 min prior to quantitation of luciferase expression using a Spectramax L luminometer (Molecular Devices). Percent neutralization was determined by subtracting background luminescence measured from cells control wells (cells only ...
-
bioRxiv - Plant Biology 2020Quote: ... using 10mM EDTA for 15 min while shaking followed by the addition of CaCl2 to a final concentration of 5 or 50mM after which the optical density at 600nm (Versamax, Molecular Devices) was measured over time.
-
bioRxiv - Biochemistry 2021Quote: ... centrifugal drying (1,000 rpm for 5 min at RT) was performed and the arrays scanned using a GenePix scanner (4100A by Molecular Devices). Microarray images were gridded and quantitated using GenePix Pro (v7 ...
-
bioRxiv - Systems Biology 2020Quote: ... DNA concentrations were measured using the SpectraMax Microplate Reader integrated on the robot (5 μl DNA samples on the SpectraDrop Micro-Volume Microplates, Molecular Devices).
-
bioRxiv - Cell Biology 2020Quote: ... The data from whole-cell patch-clamp recordings were acquired at 10 kHz and filtered at 5 kHz for analysis (Axopatch 200B amplifier with pCLAMP software, Molecular Devices). Membrane potential was clamped at 0 or −60 mV and voltage ramp-pulses from −100 to +100 mV (300 ms ...
-
bioRxiv - Biophysics 2021Quote: ... The measured membrane currents were low-pass filtered at 5 kHz and digitized at 10 kHz using a Digidata 1440A device (Molecular Devices). Data analysis was performed with Clampfit 10.2 (Molecular Devices ...
-
bioRxiv - Neuroscience 2022Quote: ... live imaging is performed with a live cell chamber-equipped to maintain 5% CO2 and 37 degrees on an IXM High throughput microscope (Molecular Devices) using a 10x objective ...
-
bioRxiv - Microbiology 2021Quote: ... aureus grown in DMEM supplemented with 10% FBS and 1% L-Glu at pH 5.5 for three days were washed with PBS before measuring luminescence on a SpectraMax i3 MiniMax 300 plate reader (Molecular Devices) in white 96-well flat bottom plates ...
-
bioRxiv - Neuroscience 2020Quote: ... Z-stacks (200-250 slices, 5 μm step) of explants were then acquired using the ImageXpress high content imaging system (Molecular Devices). 2-D projections were used for analysis of positively labelled nuclei with the Custom Module Editor (image analysis pipeline described in detail in supplementary data (fig ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were made with a pipette (tip diameter, 5–10 μm) connected to the headstage of a patch-clamp amplifier (Multiclamp 700A, Molecular Devices). Gentle suction was applied to draw the soma and a small portion of neurite into the pipette ...
-
bioRxiv - Biochemistry 2020Quote: ... Conversion of GTP to the product 2,5-diamino-6-β-ribosyl-4(3H)-pyrimidinone-5’-phosphate (DARPP) was monitored by measuring absorbance at 310 nm for 5 min using a microplate reader (Spectramax M5, Molecular Devices). The reaction rate was calculated using the extinction coefficient for DARPP (7.43 cm-1 mM-1 ...
-
bioRxiv - Immunology 2022Quote: ... The optical density was measured at 450 nm with SpectraMax ID3 microplate reader with SoftMax Pro Version 5 (both from Molecular Devices) and either titers or concentrations were calculated using as cutoff three times the optical density of the background.
-
bioRxiv - Biophysics 2020Quote: ... Currents were digitized at 5 kHz and low pass filtered at 1 kHz using a voltage clamp amplifier (Axopatch 200B, Molecular Devices) via a digitizer (DigiData 1440A ...
-
bioRxiv - Immunology 2020Quote: ... and kept at 37°C with 5% (v/v) CO2 incubator and Sytox Green fluorescence intensities were detected by a SpectraMax M2 fluorescence microplate reader (Molecular Devices) every 30 min for 180 min ...