Labshake search
Citations for Molecular Devices :
801 - 850 of 887 citations for Proteasome 26S Subunit Non ATPase 10 PSMD10 Antibody since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... and signals were filtered at 10 kHz and digitized at 50kHz using Digidata1440A and pCLAMP v10 software (Molecular Devices, Sunnyvale, CA, USA). All data were corrected for liquid junctional potential (10mV).
-
bioRxiv - Neuroscience 2022Quote: ... Recordings were sampled at 100 kHz and low pass filtered at 10 kHz using a MultiClamp 700 B amplifier and Clampex (Molecular Devices, LLC). Leak currents before mechanical stimulations were subtracted offline from the current traces ...
-
bioRxiv - Neuroscience 2022Quote: ... Signal acquisition was performed at 10 kHz, filtered with a lowpass (Bessel, 2 kHz) and collected by the acquisition software pClamp 10.5 (Molecular Devices, Sunnyvale, CA). Nicotine tartrate (30 μM in aCSF ...
-
bioRxiv - Genetics 2022Quote: ... The absorbance at 540 nm was measured at 30 s intervals for 10 min on SpectraMax340 spectrophotometer (Molecular Devices, San Jose, California). Each reaction was done in at least biological triplicate ...
-
bioRxiv - Neuroscience 2022Quote: ... Data acquisition (digitized at 10 kHz and filtered at 3 kHz) was performed with pClamp 10.4 software (Molecular Devices, Sunnyvale, CA, USA). Input resistance and cells capacitance were measured online with the membrane test feature of the pClamp software ...
-
bioRxiv - Neuroscience 2020Quote: ... Signals were low-pass filtered with a 4-pole Bessel filter at 10 kHz and digitized by a DigiData 1440A (Molecular Devices Co.) at 25 kHz ...
-
bioRxiv - Neuroscience 2021Quote: ... The signals were filtered at 2.8 kHz and digitized at 10 kHz using a MultiClamp 700B amplifier and a Digidata 1440A interface (Molecular Devices, CA, USA). Data were analyzed by using custom macros written in Igor Pro (WaveMetrics ...
-
bioRxiv - Biophysics 2022Quote: ... The output signal was filtered by a lowpass Bessel filter at 10 kHz and saved at a sampling frequency of 50 kHz using an Axon Digidata 1440A digitizer (Molecular Devices, LLC). Data analysis was performed with an in-house analysis suite created with the LabVIEW software suite (National Instruments ...
-
bioRxiv - Biophysics 2024Quote: ... Both dye uptake and electrophysiological recordings were acquired at a 2 kHz sample rate and analyzed using pClamp 10 software (Molecular Devices, USA).
-
bioRxiv - Neuroscience 2023Quote: ... Membrane potentials and currents were recorded in the whole-cell configuration by EPC9 amplifier (HEKA, Germany), and analyzed using the Igor Pro (WaveMetrics, USA) and Clampfit 10 software (Axon Instruments, Molecular Devices, USA). Membrane potential was recorded at 0 pA ...
-
bioRxiv - Biophysics 2023Quote: ... Signals were lowpass filtered at 2 kHz by a 4-pole Bessel filter and acquired at a sampling rate of 10 kHz using a Digidata 1440A (Molecular Devices, USA). Data analysis was carried out in Clampfit 10 (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Membrane currents and I-V curve were recorded and plotted in the whole-cell configuration by pulse software with the EPC-9 amplifier (HEKA, Germany) and processed with the Igor Pro (WaveMetrics, USA) and Clampfit 10 software (Axon Instruments, Molecular Devices, USA). Membrane currents was recorded at −60 mV ...
-
bioRxiv - Biophysics 2023Quote: ... Current traces were filtered at 2 kHz and acquired at 10 kHz via a Digidata 1550B interface and pCLAMP software (Molecular Devices, USA). The membrane potential was held at -60 mV during the recording ...
-
bioRxiv - Neuroscience 2023Quote: ... Membrane currents and I-V curve were recorded and plotted in the whole-cell configuration by pulse software with the EPC-9 amplifier (HEKA, Germany) and processed with the Igor Pro (WaveMetrics, USA) and Clampfit 10 software (Axon Instruments, Molecular Devices, USA). I-V curve was recorded at a holding potential from –80 mV to 80 mV with 20 mV step voltages ...
-
bioRxiv - Neuroscience 2023Quote: ... Responses to CF stimulation were recorded at a holding membrane potential of −10 mV in Purkinje cells of lobule VI using a MultiClamp 700B amplifier (Molecular Devices, CA) and acquired using the freeware WinWCP written by John Dempster (https://pureportal.strath.ac.uk/en/datasets/strathclyde-electrophysiology-software-winwcp-winedr) ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrical signals were digitized and sampled at 10-ms intervals with the Digidata 1550B data acquisition system and the Multiclamp 700B Amplifier (Molecular Devices, USA) using the pClamp software.
-
bioRxiv - Neuroscience 2024Quote: ... was sampled at 20kHz and low pass filtered at 1 kHz and analyzed in ClampFit 10 software (Molecular Devices, San Jose, CA). Optical stimulation was achieved by using a Mightex LED controller system with a 455nm blue LED and a 617nm red LED receiving and conveying TTL signals from Clampex protocols.
-
bioRxiv - Biophysics 2024Quote: The experimental equipment setup consisted of a Digidata 1440A Digitizer and a MultiClamp 700B Amplifier piloted with the pCLAMP 10 Software (all from Molecular Devices, CA). Micropipettes were pulled from thin wall borosilicate capillaires (BF100-78-10 ...
-
bioRxiv - Neuroscience 2024Quote: Signals were digitized at 10 kHz and filtered at 3 kHz using a Multiclamp 700B amplifier and analyzed using Clampfit 10.7 software (Molecular Devices, Sunnyvale, CA). Traces were excluded from analysis of specific measures if there was spontaneous activity or instability in the section of trace needed for analysis.
-
bioRxiv - Neuroscience 2024Quote: ... All whole-cell currents in response to voltage steps were low-pass filtered at 10 kHz with a Bessel filter and sampled at 20 kHz frequency (Axon Digidata 15B, Molecular Devices, USA). For inclusion in the final dataset ...
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell patch-clamp recordings were performed using a Multiclamp 700B amplifier with signals sampled at 10 kHz and digitized using a Digidata 1550B with Axon pCLAMP software (all from Molecular Devices, USA).
-
bioRxiv - Neuroscience 2024Quote: ... Voltage and current signals were filtered at 10 kHz with the built-in low-pass Bessel filter and digitized at 20 kHz using a Digidata 1440A (Molecular Devices, Sunnydale). pClamp10 software (Molecular Devices ...
-
bioRxiv - Neuroscience 2021Quote: ... Data were low pass filtered at 10 kHz and digitized at 100 kHz with a Digidata 1320A (Molecular Devices, LCC, San Jose, CA). In order to extract Boltzmann parameters ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-cell current-clamp recordings were made in a room temperature environment using HEKA EPC 10 (HEKA, Bellmore, NY) or Axopatch 200B (Molecular Devices, Sunnyvale, CA) amplifiers at a 10 kHz sampling frequency and 2.9 kHz low-pass Bessel filtering ...
-
bioRxiv - Biophysics 2020Quote: ... and recorded using pClamp9.2 software at a sampling rate of 10 kHz via an AD/DA converter (Digidata 1322A, Molecular Devices, Sunnyvale, CA, USA).
-
bioRxiv - Neuroscience 2020Quote: ... acquired at 50 KHz using a Molecular Devices 1440A A/D converter (Scientifica, UK) and recorded using Clampex 10 software (Molecular Devices, Scientifica, UK). Electrodes were pulled with a Flaming-Brown puller (P1000 ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were filtered at 1 kHz and acquired at a 10 kHz sampling rate using a DigiData 1322A data acquisition system and pCLAMP 10.3 software (Molecular Devices, San Jose, CA). Distance of the somas of the paired recorded neurons within a layer varied from ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole cell currents were filtered at 2–5 kHz with an 8-pole low-pass Bessel filter and digitized at 10–20 kHz for later off-line analysis using the pClamp 9.0 program (Molecular Devices, Inc., Sunnyvale, CA). All experiments were carried out at room temperature (22–25°C).
-
bioRxiv - Neuroscience 2021Quote: ... Cells were voltage clamped in whole-cell configuration at a holding potential of −70 mV using an Axopatch 200B amplifier running pClamp 10 (Molecular Devices; Sunnyvale, CA). Currents were elicited from cells lifted from the coverslip by the fast application of 1 mM ACh using a piezo-ceramic bimorph system with a solution exchange time of ~1 ms ...
-
bioRxiv - Neuroscience 2021Quote: ... and acquired at a sampling rate of 10 kHz using a Digidata 1440 digitizer and Clampex 10.2 software (Molecular Devices Corporation, Sunnyvale, CA). Access resistance and capacitance were compensated on-line ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were low-pass filtered at 5 kHz and sampled at 10 kHz using a digitizer (Digidata 1440A; Molecular Devices, Sunnyvale, CA, USA). In ex vivo slice recordings ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... with recording electrodes coupled to an Axopatch 200B amplifier interfacing with a Digidata 1550A data acquisition digitizer controlled on a personal computer using the pClamp 10 software (Molecular Devices, California USA). Patch pipettes were made from thick-walled borosilicate glass (1.5 x 0.86mm outer and inner diameter ...
-
bioRxiv - Immunology 2022Quote: ... All arrays were scanned at 10 µm resolution using a microarray scanner (Axon 4200AL with GenePix Pro Software, Molecular Devices, Sunnyvale, CA, USA) and fluorescence of labelled IgG was detected according to the manufacturer’s instructions ...
-
bioRxiv - Biophysics 2022Quote: ... 4-pole Bessel), sampled at 5 kHz (Digidata, 1440A) and written into digital files with pClamp 10 acquisition software (Molecular Devices, Sunnyvale, CA). Clamped cells were extracellularly perfused with solutions using BPS-8SP solenoid-valve perfusion system (ALA Scientific Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... The currents were filtered at 1 kHz and digitized at 10 kHz using a Digidata 1322A analog-to-digital converter and the Clampex 9 software package (Axon CNS Molecular Devices, Sunnyvale, CA). Data were analyzed by the customized macro for IGOR PRO software (Mosharov ...
-
bioRxiv - Neuroscience 2021Quote: ... amplifier and filtered online at 10 kHz with the built-in 4-pole Bessel filter and digitized at 20 kHz (Digidata1550B, Molecular Devices, CA, USA).)
-
bioRxiv - Neuroscience 2021Quote: ... Data were low-pass filtered at 5 kHz and acquired at 10 kHz with Axopatch 200B amplifiers and CV-7B headstages (Molecular Devices, Sunnyvale, CA). Data were acquired using an in-house program written either in Igor Pro (Wavemetrics ...
-
bioRxiv - Neuroscience 2021Quote: ... All recordings were filtered online at 10 kHz with the built-in 4-pole Bessel Filter and digitized at 20 kHz (Digidata1440, Molecular Devices, CA, USA). Traces were recorded in pCLAMP 9 (Molecular Devices ...
-
bioRxiv - Neuroscience 2020Quote: ... from the Multiclamp 700B were recorded for impulse response estimation on an NI USB-6221 BNC DAQ (National Instruments) and also recorded on a Molecular Devices Digidata 1550 digitizer and visualized with PClamp 10 (Molecular Devices, Sunnyvale, CA) for post processing.
-
bioRxiv - Microbiology 2022Quote: ... Kinetic turnover was monitored at 340 nm for 45 min every 10 s using the SpectraMax® M2 Microplate Reader (Molecular Devices, U.S.A). All data are presented as mean ± SD (n = 3) ...
-
bioRxiv - Microbiology 2022Quote: ... and the absorbance measured from 190 to 1000 nm in 10 nm intervals on a Spectramax 384 Spectrophotometer (Molecular Devices, Sunnyvale, CA, USA).
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were made with pClamp 10.3 software using a MultiClamp 700B amplifier set with 4 kHz low-pass Bessel filter and 10 kHz digitization (Molecular Devices, Sunnydale, CA). The light beam of the same laser was directed at the preparation using an 200μm optic fiber submerged into the bath with light beam aimed at the STN ...
-
bioRxiv - Neuroscience 2023Quote: ... Recorded signals were digitised online (10 kHz) with a PC based system (Digidata 1322A and Clampex 10.3 software, Molecular Devices, Sunnyvale CA, USA) and analysed off-line (Clampfit 10.3).
-
bioRxiv - Molecular Biology 2022Quote: ... Phase-contrast images were acquired at 10× magnification using a Nikon Ti-E inverted microscope with MetaMorph version 7.8 (Molecular Devices, California, United States). We performed quantitative analysis of endothelial cord-like structures using Angiogenesis Analyzer on ImageJ [29].
-
bioRxiv - Neuroscience 2024Quote: ... was loaded into individual RGCs using the single-pulse function (500 ms, -10 nA) of a MultiClamp 900A amplifier (Axon Instruments/Molecular Devices, Wokingham, UK). For the visualisation of single RGC morphologies ...
-
bioRxiv - Bioengineering 2023Quote: ... The plate was incubated for 10 min at 37°C before reading on a plate reader (SpectraMax M2, Molecular Devices, San Jose, CA) at 513 nm ...
-
Autoimmune inflammation triggers aberrant astrocytic calcium signaling to impair synaptic plasticitybioRxiv - Neuroscience 2023Quote: ... Signals were filtered at 1 kHz and acquired at a 10 kHz sampling rate using a DigiData 1550 data acquisition system and pCLAMP 10.3 software (Molecular Devices, San Jose, CA). Theta capillaries (2-5 µm tip ...
-
bioRxiv - Neuroscience 2023Quote: ... Signals were filtered at 3 KHz and sampled at 10 KHz with a Digidata 1500A analogue-to-digital conversion card (Molecular Devices, Sunnyvale, CA). Mice embryonic cortex neurons cultured in vitro between 7-14 days were recorded as a positive control ...
-
bioRxiv - Neuroscience 2023Quote: ... The recordings were low-pass filtered at 2 kHz and digitized at 10 kHz using a Multiclamp 700B amplifier (Molecular Devices, Sunnyvale, CA), Digidata 1322A digitizer (Molecular Devices) ...
-
bioRxiv - Cell Biology 2024Quote: ... Signals were filtered at 1 kHz and acquired at a 10 kHz sampling rate using a DigiData 1550 data acquisition system and pCLAMP 10.3 software (Molecular Devices, San Jose, CA). The bath solution contained (in mM) ...