Labshake search
Citations for Molecular Devices :
651 - 700 of 732 citations for 3 2 5 Dioxoimidazolidin 4 yl propanoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... digitized at 20 kHz and low-pass Bessel-filtered at 2 kHz with a personal computer running Clampex 11 and a DigiData 1440 (Molecular Devices). Two concurrent channels were captured ...
-
bioRxiv - Physiology 2020Quote: ... and Vm was recorded using sharp microelectrodes backfilled with 2 M KCl (∼150-MΩ tip resistance) connected to an amplifier (AxoClamp 2B, Molecular Devices), data acquisition system (Digidata 1322A ...
-
bioRxiv - Biophysics 2021Quote: ... 10 kHz or by-pass setting and digitized with a Digidata 1550B at a 100 kHz (10 μs bandwidth) or 500 kHz (2 μs bandwidth) sampling rate and recorded using the software pClamp 10 (Molecular Devices). The current trace was analysed using a custom written MATLAB script provided by Prof Joshua B ...
-
bioRxiv - Microbiology 2021Quote: Competitive binding of mAbs to recombinant SARS-CoV-2 RBD with hACE2 was evaluated using the ForteBio Octet HTX instrument (Molecular Devices) as described previously (34) ...
-
bioRxiv - Biophysics 2020Quote: ... Currents were filtered at 2 kHz using low-pass Bessel filter of the amplifier and digitized using a Digidata 1440 unit (Molecular Devices). All measurements were performed with extracellular (EC ...
-
bioRxiv - Neuroscience 2021Quote: ... Currents were filtered at 2 kHz using low-pass Bessel filter of the amplifier and digitized using a Digidata 1440 unit (Molecular Devices). Mechanical stimulation in cell attached patches was performed using a high-speed pressure clamp (Besch et al. ...
-
bioRxiv - Biochemistry 2023Quote: ... The detection system consisted of 2 µM Safraine O and fluorescence was monitored using a microplate reader (SpectraMax Paradigm, Molecular Devices) at Λexcitation= 495 nm ...
-
bioRxiv - Physiology 2023Quote: ... The current was induced with a 500 ms depolarization step at 0 mV from the holding potential of −60 mV using barium as the charge carrier and was sampled at 10 kHz and filtered at 2 kHz in the whole-cell voltage patch-clamp configuration with an Axopatch 200B amplifier (Molecular Devices). Peak and residual currents were obtained with Clampfit software (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: ... Voltage and current signals were low pass-filtered (10 kHz) and sequences of 2 s were acquired at 20 kHz with pClamp (Axon Instruments, Molecular Devices). Intrinsic excitability was tested with injection of current pulses (150-250 nA ...
-
bioRxiv - Neuroscience 2023Quote: ... with the analog signals filtered at 2-10 kHz and sampled at 20-50 kHz using a Digidata 1440 digitizer (Molecular Devices). Data was collected using pClamp 10 software (Molecular Devices) ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... Signals were low pass filtered (Bessel, 2 kHz) and collected at 10 kHz using the data acquisition software pClamp 11 (Molecular Devices). Electrophysiological recordings were extracted and analyzed using Clampfit (Molecular Devices ...
-
bioRxiv - Biophysics 2023Quote: ... and 95 % relative humidity for 2 h in 200 µL dye buffer according to the manufacturer’s protocol (Molecular Devices, ref: R8190). Just before the assay ...
-
bioRxiv - Biophysics 2024Quote: ... Currents were digitized at a sampling rate of 2 kHz and lowpass filtered at 10 Hz with an Axon CNS 1440A Digidata system controlled by pCLAMP 10 (Molecular Devices).
-
bioRxiv - Biophysics 2024Quote: ... Currents were low-pass filtered at 2 kHz and acquired at 10 kHz by the analogue-to-digital interface Digidata 1440 (Molecular Devices). All experiments were performed at room temperature (20°–22°C) ...
-
bioRxiv - Neuroscience 2024Quote: ... evoked synaptic currents recorded in 2 min (12 sweeps) at Vh= -70 mV were averaged and analyzed using Clampfit10 (Molecular Devices). Five electrical stimuli from a Digitimer isolated stimulator (DS2A Mk.II ...
-
bioRxiv - Neuroscience 2023Quote: ... Data was acquired using Clampex 10.7 software with an Axoclamp 700B amplifier and digitized at 20 kHz with a Digidata 1440A interface and filtered at 2 kHz (Molecular Devices). Recordings where access was greater than 30MW or that changed by >20% were discarded ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Fluorescence was measured every 2 seconds (λexcitation = 470 nm, λemission = 515 nm) using a high-throughput FLIPRTETRA cellular screening system (Molecular Devices). Peptides were added after at least 2 min of background recording ...
-
bioRxiv - Neuroscience 2024Quote: ... low-pass filtered at 2 kHz and digitized at 20 kHz using the Digidata 1440A interface and pClamp 10 software (Molecular Devices). Putative 5-HT neurons were identified on the basis of their characteristic response to a series of hyper-and depolarizing current pulses (duration ...
-
bioRxiv - Molecular Biology 2022Quote: ... NADH oxidation rate was determined by kinetic absorbance at 340 nm which was collected every 2 min for 30 min using SpectraMax M5 plate reader (Molecular Devices). To determine LDH activity ...
-
bioRxiv - Bioengineering 2022Quote: ... Membrane currents were low pass filtered at 2 kHz and digitized with a sampling rate of 10 kHz (Digidata 1440 A, Molecular Devices).
-
bioRxiv - Neuroscience 2022Quote: ... low-pass filtered at 2 KHz and digitized at 10-20 KHz using a Digidata 1322A interface driven by pClamp 10 software (Molecular Devices). Patch pipettes (4-6 MΩ ...
-
bioRxiv - Biochemistry 2023Quote: ... under 40x water-immersion lens and recorded in the whole-cell configuration using a MultiClamp 700B amplifier (2 kHz low-pass Bessel filter and 10 kHz digitization) with pClamp 11 software (Molecular Devices). Patch pipettes were pulled from OD/ID 1.5/0.86 mm capillary glass in a horizontal pipette puller (Model P-1000 ...
-
bioRxiv - Cell Biology 2022Quote: ... Images were acquired at the 2-week endpoint (day 14 of CSE treatment) at 4X magnification using the ImageXpress confocal microscope (Molecular Devices) to observe changes to spheroid size due to compound treatment ...
-
bioRxiv - Neuroscience 2024Quote: ... Spontaneous EPSCs and IPSCs were recorded in the whole-cell voltage clamp configuration at a holding potential of -70 mV and sampled at 10 kHz and filtered at 2 kHz using an Axopatch 200B amplifier and Digidata 1322A digitizer (Molecular Devices). The pipette internal solution for sEPSC contained (in mM) ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... were made using a MultiClamp 700B amplifier (2 kHz low-pass Bessel filter and 10 kHz digitization) with pClamp 11 software (Molecular Devices).
-
bioRxiv - Biochemistry 2024Quote: ... The reaction was initiated by the addition of 300 μM GTP and the fluorescence was recorded after every 2 min over 60 min at 30 °C using a plate reader FlexStation3 (Molecular devices). For measuring the activity of RdRp after incubation at 37 °C ...
-
bioRxiv - Immunology 2024Quote: ... Staining solution was replaced by live-cell visualization medium DMEMgfp-2 with 10 % FCS and images were acquired with a MetaXpress Micro XL system (Molecular Devices) at 20 x magnification.
-
bioRxiv - Neuroscience 2024Quote: ... Data were recorded at a sampling rate of 20 kHz and filtered at 2 Hz by a 8-pole Bessel filter using a MultiClamp 200 amplifier (Molecular Devices). Cells with resting membrane potential more depolarized than -50 mV and access resistance exceeding 25 MΩ were excluded from further analyses ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were filtered at 2 kHz and amplified by 1000-2000X (Multiclamp 700A amplifier, Digidata 1440A A-D board, Molecular Devices). For SWR detection ...
-
bioRxiv - Neuroscience 2024Quote: ... Spontaneous excitatory postsynaptic currents (sEPSCs) were recorded over a minimum 2-minute period at -70mV (gain 20) and analyzed in Clampfit10 (Molecular Devices; 5pA peak event threshold ...
-
bioRxiv - Biophysics 2024Quote: ... Currents were digitized at a sampling rate of 2 kHz and lowpass filtered at 10 Hz with an Axon CNS 1440A Digidata system controlled by pCLAMP 10 (Molecular Devices).
-
bioRxiv - Biophysics 2021Quote: ... Currents were digitized at a sampling rate of 5 kHz with an Axon CNS 1440A Digidata system using pCLAMP 10 (Molecular Devices, Sunnyvale, CA, USA). Each pH response was measured as the peak current after 1 minute exposure to activation buffer ...
-
bioRxiv - Neuroscience 2020Quote: Voltage- and current-clamp recordings from boutons as well a subset of somatic recordings (Figure 5 and Figures S1 and S4) were performed with quartz glass pipettes using a Multiclamp 700A patch-clamp amplifier (Molecular Devices, San Jose, USA). Quartz glass pipettes (without filament ...
-
bioRxiv - Biophysics 2022Quote: ... All recordings were voltage-clamped at −60 mV and data collected at 5 kHz using an Axopatch 200B amplifier and Digidata 1440A (Molecular Devices, San Jose, CA). Rapid application or washout of agonist were performed using a three-barreled flowpipe mounted to and controlled by a SF-77B fast perfusion system (Warner Instrument Corporation ...
-
Development of monoclonal antibody-based blocking ELISA for detecting SARS-CoV-2 exposure in animalsbioRxiv - Microbiology 2023Quote: ... MA) in 5 min and color intensity was quantified at 405 nm using a SpectraMax® iD5 microplate reader (Molecular Devices, San Jose, CA). The percentage of inhibition was calculated using the following formula:
-
bioRxiv - Neuroscience 2022Quote: ... Signals were recorded using a 5 KHz lowpass filter at a sampling frequency of 20 kHz using the Digidata 1440A digitizer (Molecular devices, Sunnyvale, CA, USA) with Clampex (v10.6 ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings were filtered at 5 kHz with the amplifier internal filter and digitized at 50 kHz using a Digidata 1550B digitizer (Molecular Devices, San Jose, CA). The recording pipette was filled with (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Signals were recorded using a 5 KHz low-pass filter at a sampling frequency of 20 KHz using the Digidata 1440A digitizer (Molecular devices, Sunnyvale, CA, USA) with Clampex (v10.6 ...
-
bioRxiv - Neuroscience 2023Quote: ... Signals were filtered at 5 kHz and sampled at 10 kHz with a Digidata 1440A digitizer and pClamp10 software (Molecular Devices, San Jose, CA). Series resistance (3–5MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... and current clamped recordings were made using a MultiClamp 700B amplifier (2 kHz low-pass Bessel filter and 10 kHz digitization) with pClamp 10.3 software (Molecular Devices, Sunnyvale, CA). Firing rate was determined before breaking into the cell under cell attached mode for at least 60 seconds of continuous activity ...
-
bioRxiv - Neuroscience 2022Quote: ... Signal acquisition was performed at 10 kHz, filtered with a lowpass (Bessel, 2 kHz) and collected by the acquisition software pClamp 10.5 (Molecular Devices, Sunnyvale, CA). Nicotine tartrate (30 μM in aCSF ...
-
bioRxiv - Cell Biology 2022Quote: ... Whole-cell current-clamp recording was carried out at room temperature (22 ± 2 °C) using an Axopatch 200B amplifier (Molecular Devices, USA). Pipette (Intracellular ...
-
bioRxiv - Genetics 2020Quote: ... 100 µL of the supernatant were transferred in another transparent plate before reading absorbance at 450 ± 2 nm on SpectraMax® 190 microplate reader (Molecular Devices). For β-arrestin2 recruitment assays ...
-
bioRxiv - Biophysics 2024Quote: ... Both dye uptake and electrophysiological recordings were acquired at a 2 kHz sample rate and analyzed using pClamp 10 software (Molecular Devices, USA).
-
bioRxiv - Neuroscience 2023Quote: ... Membrane voltage and current were sampled at 10-25 kHz and low-pass filtered at 2-10 kHz using the patch clamp amplifier MultiClamp 700B (Molecular Devices, LLC), digitized and sampled by Micro 1401 with Spike2 software (Cambridge Electronic Design ...
-
bioRxiv - Neuroscience 2022Quote: ... Traces were digitized using an Axon 1440A Digitizer at 10 kHz and filtered at 2 kHz using Clampex 10 software (Molecular Devices, USA). After achieving a stable whole-cell recording ...
-
bioRxiv - Biophysics 2023Quote: ... Current traces were filtered at 2 kHz and acquired at 10 kHz via a Digidata 1550B interface and pCLAMP software (Molecular Devices, USA). The membrane potential was held at -60 mV during the recording ...
-
bioRxiv - Neuroscience 2024Quote: ... under a low-pass filtered at 2 kHz and digitized at 10k Hz by Axon Digidata 1550B interface (Molecular Devices, CA, USA) coupled with Clampex software (Molecular Devices ...
-
bioRxiv - Neuroscience 2024Quote: ... upon a low pass filtered at 2 kHz and digitalized at 10k Hz by Axon Digidata 1440A interface (Molecular Devices, CA, USA) coupled with Clampex software (Molecular Devices ...
-
bioRxiv - Biophysics 2024Quote: ... filtered at 2 kHz and stored on IBM-CompatiblePC interfaced with a Digidata 1440 analogue to digital converter (Molecular Devices,Sunnyvale, CA). Initial series resistance values were 2-5 MΩ ...