Labshake search
Citations for Beckman :
101 - 150 of 1939 citations for 6 Methyl 2 3 4 9 tetrahydro 1H carbazole 1 carboxylic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... followed by ultracentrifugation at 70k RPM at 4⁰C for 2 h (Optima TLX ultracentrifuge, Beckman Coulter). Ribosome pellets were then resuspended in Trizol and extracted for RNA according to manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2024Quote: ... centrifuged twice at 100,000 × g for 2 h at 4°C (Beckman Coulter Optima XE-90 Ultracentrifuge). The supernatant was replaced with DPBS between ultracentrifugation spins ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C for 1 h with MLS-55 rotor (Beckman Coulter). The pellets were lysed in 40 μL of radioimmunoprecipitation (RIPA ...
-
bioRxiv - Cell Biology 2020Quote: ... Fractions were diluted and washed in PBS for 1h at 100,000 x g in a TLA 110 rotor (Beckman). Fractions were resuspended in 35 ul of PBS ...
-
bioRxiv - Biophysics 2021Quote: ... 20-24 h), the samples were ultracentrifuged (1h, 288’000 x g) (Optima TLX Ultracentrifuge, Beckman Coulter, TLA-120.2 Beckman rotor) to remove large aggregates ...
-
bioRxiv - Developmental Biology 2023Quote: ... the supernatant was centrifuged in a TLA100.4 fixed angle rotor at 100000 g for 1h at 37°C in an Optima TL ultracentrifuge (Beckman). The supernatant containing globular actin was collected ...
-
bioRxiv - Cell Biology 2019Quote: Viability of unlabeled and ferumoxytol-labeled murine MSCs (n=4) and human MSCs (n=3) was assessed by Trypan blue dye exclusion using ViCell (Beckman Coulter).
-
bioRxiv - Molecular Biology 2019Quote: ... followed by 3 h ultracentrifugation at 100,000 g and 4 °C using SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Resulting pellets were resuspended in 100 µl PBS and stored at −80 °C until further use ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was ultracentrifuged at 120,000 g for 3 h at 4°C using an MLS-50 rotor (Beckman Coulter, USA) to collect 120k pellet vesicles ...
-
bioRxiv - Biophysics 2021Quote: The aggregation products formed in Eppendorf tubes under agitation conditions at pH 3 and pH 4 were centrifuged using an Optima MAX-XP ultracentrifuge (Beckman Coulter) in a TLA-55 rotor at 40,000 rpm at 20°C for 45 min ...
-
bioRxiv - Molecular Biology 2021Quote: ... Gradients were centrifuged at 36000 RPM for 2 hours at 4°C in a SW41 rotor (Beckman Coulter) and then fractions were collected using a gradient collector (Teledyne ISCO gradient station ...
-
bioRxiv - Microbiology 2020Quote: ... Purification was done by ultracentrifugation for 2 h at 154,000xg at 4°C in a SW41 rotor (Beckman) using a two-step sucrose gradient (20%/50% w/v in HNE) ...
-
bioRxiv - Cell Biology 2020Quote: ... the cleared supernatant was ultracentrifuged at 47,000 g for 2 hours at 4 °C using the JA25.50 rotor (Beckman). The virus was resuspended overnight in 180 μL D10 medium at 4 °C ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 °C for 2 h in an Optima L-100XP ultracentrifuge (with SW 55 Ti rotor, Beckman Coulter). Fractionation was done manually by collecting every 200 μl volume from the top till the bottom of each centrifuge tube ...
-
bioRxiv - Molecular Biology 2023Quote: ... Digested extracts were then loaded on 1 M sucrose cushions 116 and centrifuged at 70,000 rpm for 2 hours at 4°C in a TLA100.4 rotor (Beckman). Ribosome pellets were resuspended in 300 µl of TRIzol reagent (Invitrogen) ...
-
bioRxiv - Biochemistry 2020Quote: ... the crude mitochondria were undergone a sucrose gradient in SEM buffer for 1h at 139,400 x g with an SW40 Ti rotor (Beckman Coulter). Mitochondrial band was pooled and stored at −80 °C.
-
bioRxiv - Plant Biology 2021Quote: ... sucrose was transferred to the bottom of the tube using a Pasteur pipette and centrifuged at 27,000 rpm for 3 hours at 4° C using an SW28 Ti rotor (Beckman Coulter, Brea, CA). Each pellet containing the virus particles was resuspended in 1 mL resuspension buffer overnight with gentle shaking at 4 °C ...
-
bioRxiv - Microbiology 2019Quote: ... The filtrate was then re-centrifuged at 125000 × g at 4° C for 3 hours (Optima™ L-XP ultracentrifuge, Beckman, USA). The obtained pellet was suspended in 300 µl sterile phosphate-buffered saline (PBS) ...
-
bioRxiv - Cell Biology 2022Quote: ... and centrifuged at 16000 ×g for 3 hours at 4 °C in an Avanti J-25 centrifuge (Beckman Coulter Life Sciences, USA) with a JA-25.50 fixed-angle aluminum rotor (Beckman Coulter Life Sciences ...
-
bioRxiv - Molecular Biology 2021Quote: ... sucrose gradients prepared with lysis buffer without Triton X100 and centrifuged at 32,000 rpm for 3 hrs at 4 °C in an SW41Ti rotor (Beckman Coulter, Cat:331362). The sucrose gradients were fractionated using BR-188 Density Gradient Fractionation System with 60% (m/v ...
-
bioRxiv - Cell Biology 2019Quote: ... Sucrose gradients were subjected to ultracentrifugation (SW41 Ti 11E1698 rotor; Beckman at 260,000xg for 2 h at 4□°C) and fractionated by displacement using 60% sucrose/0.01% bromophenol blue on an ISCO Foxy fraction collector (35 s for each fraction ...
-
bioRxiv - Cell Biology 2020Quote: ... Lysates were loaded on the top of the gradient and centrifuged at 260,000 × g and 4 °C for 2 h using SW 41 rotor (Beckman). Collection of polysomal fractions were done using Piston Gradient Fractionator (BioComp) ...
-
Human Sex Matters: Y-linked lysine demethylase 5D drives accelerated male osteogenic differentiationbioRxiv - Cell Biology 2021Quote: ... Virus was transferred into conical tubes and spin at 20000rpm for 2 hours at 4°C in (Beckman TST2838) swinging bucket rotor ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM DTT) by being centrifuged at 73000 rpm for 45 minutes at 4°C (Beckman Coulter TL120.2 rotor). The mitoribosomal pellet was subsequently resuspended in ribosome resuspension buffer (25 mM HEPES-KOH pH = 7.5 ...
-
bioRxiv - Neuroscience 2022Quote: ... and centrifuged at 24,000 rpm for 2 h at 4°C using a SW-Ti32 swinging bucket (Beckman Coulter). The upper layer was discarded ...
-
bioRxiv - Cell Biology 2021Quote: ... Pellets were resuspended in 0.9% NaCl and spun at 110,000 × g for 2 hours at 4°C in an XPN-80 ultracentrifuge equipped with a Type 50.4 Ti rotor (Beckman Coulter ...
-
bioRxiv - Microbiology 2021Quote: ... The VLPs were concentrated by ultracentrifugation for 2 h at 31,000 rpm at 4 °C (Beckman SW-31Ti rotor), and then resuspended in 500 μL of Ex-Cell 405 medium ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Plant Biology 2023Quote: ... Extract was then centrifuged at 40 000 rpm for 2 hours at 4°C using the 50Ti rotor (Beckman). A protocole previsouly used in the laboratory and described in Maclot et al ...
-
bioRxiv - Neuroscience 2023Quote: ... Samples were then centrifuged at 82,600×g at 4°C for 2 h (Beckman ultracentrifuge optima L-100 XP). After the first ultracentrifugation ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1-1.5 μg of total protein was loaded onto a 10% to 50% sucrose gradient and centrifuged at 36,000 rpm for 2 hours at 4°C using an SW41 rotor (Beckman). Polysome profiles were visualized ...
-
bioRxiv - Microbiology 2023Quote: ... 500 μ g of the lysate was loaded on the top of 15–50% sucrose gradient containing 100μ g/ml cycloheximide and the gradients were centrifuged at 36,000 rpm for 2 h at 4°C in SW41 rotor (Beckman). Density Gradient Fractionation System (ISCO ...
-
bioRxiv - Cancer Biology 2023Quote: ... the obtained supernatant was filtered through a 0.22 μm filter before ultracentrifugation at 150,000 g for 2 h at 4 °C (Beckman Coulter). The nsEV-containing pellet was resuspended in phosphate buffer saline (PBS).
-
bioRxiv - Microbiology 2023Quote: ... The samples were centrifugated at 70000 rpm for 2 h at 4°C in an Optima TLX Ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Genetics 2023Quote: ... Fifteen A260 units of WCEs were layered on a pre-chilled 10-50% sucrose gradient and centrifuged at 40,000 rpm for 2 h at 4°C in a SW41Ti rotor (Beckman). Gradient fractions were continuously scanned at A260 using the BioComp Gradient Station and polysome to monosome (P/M ...
-
bioRxiv - Cancer Biology 2024Quote: ... 100 μg/mL cycloheximide) for 2 h at 40,000 g at 4 °C using an SW41 rotor (Beckman Coulter). Gradients were fractionated using Teledyne Isco Tris Peristaltic Pump and fractions were collected and pooled according to the UV trace ...
-
bioRxiv - Cell Biology 2024Quote: ... samples were ultracentrifuged at 160,000 xg for 2 h at 4 °C in ultracentrifuge tubes (Beckman Coulter Cat #328874). The resulting pellet contained the insoluble AMB-1 cell fraction and the supernatant contained the soluble fraction ...
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant was then subjected to ultracentrifugation at 100,000 x g for 2 h at 4 °C to sediment small EVs (Optima L-80K ultracentrifuge, Beckman Coulter ...
-
bioRxiv - Cell Biology 2020Quote: ... The supernatants were collected and subjected to high-speed centrifugation at 100,000 × g for 1h (TLS-55 rotor, OptimaTMMAX Ultracentrifuge; Beckman Coulter, Germany). The supernatants (S100 ...
-
bioRxiv - Microbiology 2019Quote: ... and the remaining 32 mL were centrifuged at 500 × g for 3 min at 4°C (Allegra X-15R, Beckman Coulter, Villepinte, France) to spin down the remaining meat fibers and debris ...
-
bioRxiv - Cancer Biology 2022Quote: ... 10 nM leptomycin b, vehicle control or library compounds (Supplementary Tables 2, 3) were added using an Echo liquid handler (Labcyte/Beckman Coulter). Cells were incubated for a further 24 h then fixed in 4% paraformaldehyde and stained with DAPI and Alexa Fluor 488 Phalloidin (ThermoFisher) ...
-
bioRxiv - Genetics 2020Quote: ... Timepoints were measured every 2-3 days by flow cytometry analysis of >7,000 cells (either a BD Accuri C6 or Beckman Coulter CytoFLEX). Data was analyzed using Cytoflow (https://github.com/bpteague/cytoflow ...
-
bioRxiv - Genomics 2021Quote: ... samples were purified with 45 µl of Agencourt AMPure XP magnetic beads with a sample to beads ratio of 3:2 (Beckman Coulter), normalized by Qubit quantification and pooled to generate a 4 nM library ...
-
bioRxiv - Neuroscience 2021Quote: ... Samples were centrifuged at 135,000 × g for 1 hr at 4°C (Beckman OptimaTM Max centrifuge ...
-
bioRxiv - Immunology 2021Quote: ... Flow cytometry was performed on CyAN ADP LX 9-colour flow cytometer (Beckman Coulter, Pasadena, CA).
-
bioRxiv - Immunology 2021Quote: Flow cytometry was performed on CyAN ADP LX 9-colour flow cytometer (Beckman Coulter, Pasadena, CA) or LSRII (Becton Dickinson) ...
-
bioRxiv - Microbiology 2020Quote: ... Excess dye was removed by ultracentrifugation of the virus through a 10% sucrose cushion for 2 h at 107,000 × g and 4°C using an SW41 rotor (Beckman Coulter). Labeled virus pellets were resuspended at a viral protein concentration of 1 mg/ml ...
-
bioRxiv - Molecular Biology 2019Quote: ... for 2 h at 4°C and then further purified using CsCl equilibrium gradient ultracentrifugation at 35,000 rpm (Beckman SW56) for 18 h at 4°C ...