Labshake search
Citations for Beckman :
351 - 400 of 2048 citations for E 6 2 6 6 Trimethylcyclohex 2 en 1 yl hex 5 ene 2 4 dione since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2021Quote: ... Beckman Coulter Access SARS-CoV-2 IgG assays (Brea, CA, USA) targeting the RBD were performed on UniCel DxI 800 Access Immunoassay System (Beckman Coulter). Index value threshold for positivity was 1 as recommended ...
-
bioRxiv - Immunology 2020Quote: ... erythrocytes in 2 μl blood (collected from the tail tip) were counted using a Z2 Coulter Particle count and size analyser (Beckman Coulter). We determined the healthy range in uninfected C57Bl/6J mice housed in our facility to be 8.8 - 10.5*109 erythrocytes*ml−1 ...
-
bioRxiv - Microbiology 2021Quote: ... and either aliquoted or concentrated by ultracentrifugation using 20% (w/v) sucrose cushions for 2 hours at 25,000 rpm in an SW41 or SW28 rotor (Beckman, Indianapolis, IN). Alternatively ...
-
bioRxiv - Immunology 2020Quote: ... 2) first-round PCRs were set up using a Biomek FX liquid handling system with a 96- well head (Beckman Coulter); 3 ...
-
bioRxiv - Genomics 2021Quote: ... samples were purified with 45 µl of Agencourt AMPure XP magnetic beads with a sample to beads ratio of 3:2 (Beckman Coulter), normalized by Qubit quantification and pooled to generate a 4 nM library ...
-
bioRxiv - Cell Biology 2022Quote: ... A 12 ml 2 % step Optiprep gradient in LB ranging from 32 % to 10 % was prepared beforehand in Ultra-Clear tubes (Beckman Coulter). Samples were spun for 16 hours at 100000 g at 4 °C ...
-
bioRxiv - Genomics 2024Quote: ... The crude nuclei were stained with 4,6-diamidino-2-phenylindole (DAPI) and loaded into a flow cytometer (Beckman Coulter, MoFlo XDP). Nuclei were purified by flow sorting and washed as described previously [61] ...
-
bioRxiv - Biochemistry 2024Quote: ... 50 mM Tris-HCl pH 7.4) and ultracentrifuged at 250 000 x g for 2 h (Beckman Optima TL 100 Ultracentrifuge). After ultracentrifugation ...
-
bioRxiv - Microbiology 2023Quote: ... viruses were collected and concentrated by ultracentrifugation (37,000 rpm, 2 h 30, 15 °C; Beckman Type 45 Ti fixed-angle rotor). The virus titer was determined using a plaque assay.
-
bioRxiv - Microbiology 2023Quote: ... the DNA monitored on 2% agarose gel was purified by means of AMPure XT beads (Beckman Coulter Genomics, Danvers, MA, USA) and quantified by Qubit (Invitrogen ...
-
bioRxiv - Biophysics 2023Quote: ... and 12-fold diluted in ice-cold SCL and subjected to ultracentrifugation at 100 000 x gav for 2 h in a Ti 70 fixed-angle rotor (Beckman Coulter). The resulting pellets were resuspended in SCL and freshly used for downstream analysis and never subjected to freezing and thawing.
-
bioRxiv - Biochemistry 2024Quote: ... 1 mL reaction buffer containing substrates (25 μM-0.16 mM NADH and 2 mM pyruvate) was added to the cuvette of a spectrophotometer (DU® 700, Beckman Coulter). The reaction was started by adding cell lysate ...
-
bioRxiv - Cancer Biology 2024Quote: ... The exosome pellet was resuspended in 35 ml of 0.2 μm-filtered 1x PBS and collected by ultracentrifugation at 100,000 × g for 2 h (45ti rotor, Optima L-100 XP Centrifuge, Beckman Coulter, USA). Exosome pellets were resuspended in 200-300 µL of 0.2 μm-filtered 1x PBS and stored at -80°C ...
-
bioRxiv - Biochemistry 2022Quote: ... A soluble fraction was obtained after centrifugation of the lysate at 19,000 rpm for 40 min at 4 °C performed using Avanti J-E with a rotor JA-20 (BECKMAN COULTER) to remove insoluble debris.
-
bioRxiv - Neuroscience 2020Quote: ... Final 15 mL of solution was mixed by inverting the tube 10x and carefully pipetted into 2 ultracentrifuge tubes (Beckman Coulter #344059) onto the isolation buffer cushion (5 mL ...
-
bioRxiv - Microbiology 2020Quote: ... were pelleted through a 20% (wt/vol) sucrose cushion at 25,000 rpm for 2 h in an SW41 rotor (Beckman Coulter, Tokyo, Japan). Then ...
-
bioRxiv - Neuroscience 2022Quote: ... which was then sealed and placed into a hematocrit spinner (2 minutes at 13, 700 g; StatSpin CritSpin Microhematocrit Centrifuge, Beckman Coulter, Inc). Measurements were taken to calculate percent (% ...
-
bioRxiv - Cancer Biology 2022Quote: ... The cell pellet was disaggregated and incubated with 2 μL of anti-pan cytokeratin-FITC (Beckman Coulter, Cat. No. IM2356U, Clone J1B3). A separate tube containing cells unstained for surface E-Cadherin was incubated after permeabilization with E-Cadherin antibody- (R&D Cat ...
-
SLC15A4 favors inflammasome function via mTORC1 signaling and autophagy restraint in dendritic cellsbioRxiv - Immunology 2022Quote: ... Cells were finally washed in PBS with 0.5% BSA and 2 mM EDTA and analyzed by flow cytometry using a CytoFLEX (Beckman Coulter, Indianapolis, IN) and FlowJo software (BD Biosciences) ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... Clarified supernatants were layered over 2 ml of a 25% (w/v) sucrose solution in 13.2 ml Thinwall Polypropylene SW41 Ti ultracentrifuge tubes (Beckman-Coulter, Brea, USA) and made up to a total volume of 10 ml with PBS without calcium chloride or magnesium chloride (PBS[-]) ...
-
bioRxiv - Molecular Biology 2020Quote: ... was subjected to centrifugation at 100,000g for 2 h in an Optima MAX-XP benchtop ultracentrifuge with a TLA-100.3 rotor (Beckman Coulter, Inc., Brea, CA). Pellets were resuspended in 100 µl PBS and stored at −80 °C.
-
bioRxiv - Neuroscience 2020Quote: ... Homogenates were layered on top of 1 ml of 0.85 M sucrose in 2 mM EGTA and centrifuged at 75,000 g for 30 min in a Beckman FW-27 rotor (Beckman, Fullerton, CA, USA). This step was repeat twice ...
-
bioRxiv - Microbiology 2021Quote: ... soil was thoroughly mixed with 20 ml of 0.01 M CaCl2 for 30 min on a Elmi Intelli-Mixer RM-2 (Elmi Tech Ltd, Latvia) and subjected to centrifugation in an Allegra X-22R centrifuge (Beckman Coulter, USA) at 3900 rcf for 20 min and to remove inorganic S (Dedourge et al. ...
-
bioRxiv - Microbiology 2023Quote: ... the prepared DNA library was size-selected on a 2% agarose gel (410–470 bp) using the Agencourt SPRI system to reduce mitochondrial contamination (Beckman Coulter, Inc.). After library prep ...
-
bioRxiv - Biophysics 2023Quote: ... The virions were concentrated by ultracentrifugation through a 20% (w/v) sucrose cushion (2 h at 28,000 rpm in a SW32 rotor [Beckman Coulter Life Sciences]). The pellet was resuspended in PBS ...
-
bioRxiv - Genetics 2023Quote: ... in-house VLPs were produced using the same protocol followed by ultracentrifugation at 24,000 RPM for 2 hours (SW 28 Beckman swinging bucket rotor) to concentrate the VLPs and avoid diluting the HSPCs culture media ...
-
bioRxiv - Biophysics 2020Quote: ... lysate was centrifuged at 5 °C with 13000 rpm for 15 min by Avanti J-E Ultra Centrifuge (Beckman Coulter). Supernatant from centrifugation was filtered with 0.45 μm SFCA syringe filters (Sigma Aldrich ...
-
bioRxiv - Immunology 2021Quote: ... 1×106 thawed PBMCs were centrifuged (750×g for 5 minutes at 4°C) using a swinging bucket rotor (Beckman Coulter Avanti J-15RIVD with JS4.750 swinging bucket ...
-
bioRxiv - Microbiology 2020Quote: ... The clarified supernatant was overlaid onto a 20% (w/v) sucrose cushion in Tris-NaCl-EDTA buffer and centrifuged at 134,000 g for 2 hours (Beckman Coulter 30 Ti rotor). The resulting viral pellet was suspended in VCM by repeat pipetting and aliquots stored in cryovials at minus 70°C until needed ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μM or 10 μM from a 2 mM or 10 mM stock solution using a Biomek FX with 384-well head (Beckman Coulter, Indianapolis, IN). The DMSO concentration was kept below or at 0.5% v/v ...
-
bioRxiv - Physiology 2022Quote: ... the library preparation step followed the CEL-Seq 2 protocol85: the RT product was digested by ExoI and HinFI and purified using AMpure XP beads (Beckman Coulter™, USA). Then ...
-
bioRxiv - Molecular Biology 2024Quote: ... Each compound was dissolved in DMSO at a concentration of 2 mM and distributed into an Echo Qualified 384-Well Polypropylene Microplates (Beckman Coulter, 001-14615). Using an Echo 655 Liquid Handler ...
-
bioRxiv - Microbiology 2022Quote: ... The success of the amplifications was checked in a 2% agarose gel and PCR products were subsequently purified using Agencourt AMPure XP magnetic beads kit (Beckman Coulter, Brea, CA, USA), quantified with the QuantiFluor™ dsDNA System (Promega ...
-
bioRxiv - Biochemistry 2023Quote: ... cells were treated with the drugs (20 µM to a suspension at 500,000 cells/mL in PBS containing 2 % FBS at 37°C) and directly analyzed by flow cytometry (Gallios, Beckman-Coulter, 405/488 nm laser) over 2 h ...
-
Scalable Fabrication of a Tough and Recyclable Spore-Bearing Biocomposite Thermoplastic PolyurethanebioRxiv - Bioengineering 2024Quote: ... Spore suspension was centrifuged at 12,000 g at 4 °C for 20 min (Avanti J-E, Beckman Coulter Life Science, Brea, CA, USA). After removing supernatant ...
-
bioRxiv - Cell Biology 2021Quote: ... Beads were centrifugated at 1000 g for 5 min at 4°C (Beckman Coulter Microfuge 22R ...
-
bioRxiv - Cancer Biology 2020Quote: ... Filtered media containing lentiviral particles were centrifuged at 24000rpm at 20°C for 2 hrs in 90Ti rotor in ultra-centrifuge (Beckman Coulter Optima TM L-100K). Viral particle pellet was obtained after discarding supernatant post centrifugation and suspended in 100 μl OptiMEM media for overnight at 4°C.The collected lentivirus suspension was used for transfection or stored for later use at −80°C ...
-
bioRxiv - Microbiology 2024Quote: ... Viruses were collected 48 hours post-transfection and pelleted in DPBS over a 10% sucrose cushion at 25,000 RPM for 2 hours using a SW32Ti rotor (Beckman Coulter Life Sciences, Brea, CA, USA). Virus pellet was then resuspended in labeling buffer (50 mM HEPES pH 7.0 ...
-
bioRxiv - Neuroscience 2021Quote: ... 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge; Beckman Coulter, Fullerton, CA) for 30 min ...
-
bioRxiv - Microbiology 2023Quote: ... another 2 mL of staining bacterial samples was analyzed with a flow cytometry to check cell viability (Beckman CytoFLEX FCM, USA, Channel FL2-A: PE-A).
-
bioRxiv - Plant Biology 2024Quote: ... using an OptimaTM MAX-E ultracentrifuge (Beckman Coulter) equipped with a TLA120.2 fixed angle rotor (Beckman Coulter ...
-
bioRxiv - Biophysics 2023Quote: ... Cells were harvested by centrifugation at 8000 g at 4°C for 20 min (Avanti® J-E centrifuge from Beckman Coulter, rotor: JLA 16.250).
-
bioRxiv - Bioengineering 2023Quote: ... subtilis spores were collected from the culture by the centrifugation at 8000 rpm at 4 °C for 20 min (Avanti J-E, Beckman Coulter Life Science, IN, USA). Supernatant was removed and the spore pellets were resuspended in fresh 100 mM PBS pH 7.4 ...
-
bioRxiv - Microbiology 2021Quote: 1 mL pseudoparticles were pelleted using a TLA-55 rotor with an Optima-MAX-E ultracentrifuge (Beckman Coulter) for 2 hours at 42,000 rpm at 4°C ...
-
bioRxiv - Genomics 2024Quote: ... 4°C for 1:30h (Beckman Coulter SW32Ti). The pellet was ultimately resuspended with StemSpanTM SFEM-II media (Stemcell Technologies ...
-
bioRxiv - Cell Biology 2020Quote: ... spinning at 3,200 rpm (Beckman J-6M/E centrifuge). The centrifuge chamber was set at 4°C during all centrifugation steps until approximately 10 min before cell harvesting ...
-
bioRxiv - Plant Biology 2021Quote: ... reinhardtii cells were collected at 1,870 × g and 4°C for 5 min (JLA9.1000, Beckman Coulter). The cells were resuspended at 0.125 mg Chl/mL with disruption buffer containing 25 mM MES-NaOH (pH 6.5) ...
-
bioRxiv - Biochemistry 2021Quote: ... and centrifuged for 5 h with 116,000 xg at 4°C in a TLA100.3 rotor (Beckman). Binding to the different fractions was assessed by Western blot ...
-
bioRxiv - Immunology 2021Quote: ... and centrifuged (400×g for 5 min at 4°C) using a swinging bucket rotor (Beckman Coulter Avanti J-15RIVD with JS4.750 swinging bucket ...
-
bioRxiv - Immunology 2022Quote: ... and centrifuged (400×g for 5 min at 4°C) using a swinging bucket rotor (Beckman Coulter Avanti J-15RIVD with JS4.750 swinging bucket ...