Labshake search
Citations for Beckman :
301 - 350 of 1231 citations for 7 Hydroxy 4 methylcoumarin 3 acetic acid succinimidyl ester since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2022Quote: ... samples (10 mL) were first centrifuged at 7000Xg at 4°C for 30 minutes (Beckman Coulter Avanti J-E Series ...
-
bioRxiv - Biochemistry 2021Quote: ... The bacterial culture was centrifuged at 4,000 × g for 15 min at 4°C (Beckman) and the cell pellet was resuspended in 30-40 mL of lysis buffer (50 mM HEPES pH 8.0 ...
-
bioRxiv - Cell Biology 2019Quote: ... and ultracentrifuged with a 70 Ti rotor (Beckman Coulter; 50,000 rpm, 75 min, 4°C). The supernatants obtained (around 40 ml each ...
-
bioRxiv - Physiology 2019Quote: ... and spun at 100,000xg for 20m at 4°C in Optima Max ultracentrifuge (Beckman Coulter). Tubes were carefully removed from the ultracentrifuge with forceps and 30 uL of supernatant was removed to a PCR tube with every care taken to avoid the protein pellet ...
-
bioRxiv - Cancer Biology 2019Quote: ... held at 4 °C) and then cleaned up with the SPRIselect Reagent Kit (Beckman Coulter). A qualitative analysis on the amplified cDNA was performed using Agilent Bioanalyzer high sensitivity chip.
-
bioRxiv - Neuroscience 2021Quote: ... at 25000 rpm (SW28, 4°C) in an 80K ultracentrifuge (Beckman Coulter; Brea, California, USA). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... at 5,000 g for 30 minutes at 4°C and subsequently at 10,000 g (Beckman Coulter Optima L-90K with a SW40Ti rotor) ...
-
bioRxiv - Biophysics 2021Quote: ... 2mM MgCl) centrifuged for 16 hours at 35k rpm at 4 °C (Beckman TLS-55). 80S ribosome was found to have formed a pellet at the bottom of the tube and was resuspended in 20mM HEPES pH 7.9 ...
-
bioRxiv - Neuroscience 2020Quote: ... The gradients were ultracentrifuged for 2.5 hours (4°C) in a SW41Ti rotor (Beckman Coulter) at 35000 rpm ...
-
bioRxiv - Immunology 2021Quote: ... at 23,000 rpm for 2,5h at 4°C in sterile Ultra-clear centrifuge tubes (Beckman) using an SW28 swinging bucket rotor (Beckman) ...
-
bioRxiv - Immunology 2021Quote: ... After overnight centrifugation (at 4 °C) at 100,000×g (Beckman Coulter Optima L-90 ultracentrifuge) collected 2 mL fractions were analysed by SDS-PAGE ...
-
bioRxiv - Genomics 2021Quote: ... (4) The final PCR product was purified by 1.8x AMPure XP beads (Beckman Coulter Genomics) followed by a second gel size-selection for the range of 300 to 575 bp for C ...
-
bioRxiv - Plant Biology 2022Quote: ... 0.1 mM AEBSF) and centrifuged (270000 g, 90 min, 4°C, TLA 100.3, Beckman Coulter). The pellet was solubilized in sample buffer and subsequently applied to SDS-PAGE and Western blot analyses.
-
bioRxiv - Microbiology 2022Quote: ... then centrifuged at 175 000 g at 4°C overnight in a Sw55TI rotor (Beckman). For labelled VLPs ...
-
bioRxiv - Biochemistry 2022Quote: ... followed by ultracentrifugation at 18,000g for 35 min at 4 °C (Optima XPN, Beckman Coulter). The clarified supernatant was loaded through a sample pump of an NGC Quest 10 Chromatography System (Bio-Rad Laboratories ...
-
bioRxiv - Developmental Biology 2023Quote: ... and centrifuged at 40,000 rpm for 1 h at 4°C (Beckman SW-41Ti rotor). Supernatants were discarded ...
-
bioRxiv - Microbiology 2023Quote: ... Supernatants were ultracentrifuged at 200,000 xg for 45 min at 4°C (TI45 Beckman rotor). Total membrane pellet was resuspended in 500 µL of buffer B (10 mM Tris-HCl pH 7.4 ...
-
bioRxiv - Biochemistry 2023Quote: ... The supernatant was collected after centrifugation at 4 °C and 4000 × g (Beckman Coulter, USA) for 30 min ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 °C using the swing- out rotor TLS-55 on an Optima Max (Beckman Coulter) ultracentrifuge ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 °C using the fixed-angle rotor TLA-120.2 on an Optima TLX (Beckman Coulter) ultracentrifuge ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 °C using the fixed-angle rotor TLA-120.2 on an Optima TLX (Beckman Coulter) ultracentrifuge ...
-
bioRxiv - Molecular Biology 2023Quote: ... 4 °C using the swing-out rotor SW32 on an Optima L-90K (Beckman Coulter) ultracentrifuge ...
-
bioRxiv - Cell Biology 2023Quote: ... Upon centrifugation for 30 min at 4 °C (96,000 g, Rotor TLA-100, Beckman Coulter), the resulting supernatant yields soluble glycosomal matrix proteins while the pellet contains membrane-associated proteins ...
-
bioRxiv - Cell Biology 2023Quote: ... The lysate was centrifuged at 4 °C for 15 min in a TLA55 rotor (Beckman) at 50,000 rpm to remove insoluble material ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14) in order to remove cell debris ...
-
bioRxiv - Genetics 2023Quote: ... The gradients were sedimented at 35,000 rpm at 4°C in a SW41 rotor (Beckman) for 2 h 40 min ...
-
bioRxiv - Neuroscience 2024Quote: ... and centrifuged at 28,000rpm for 2h at 4 °C in a SW 41 rotor (Beckman). The virus pellet was resuspended in 60μL of PBS ...
-
bioRxiv - Biochemistry 2023Quote: ... The microsomes were sedimented by centrifugation at 4°C in the TLA-55 rotor (Beckman) at 55,000 rpm for 20 min ...
-
bioRxiv - Cancer Biology 2024Quote: ... followed by ultracentrifuge concentration (25,000 rpm for 90 min at 4°C; Beckman SW32Ti rotor).
-
bioRxiv - Synthetic Biology 2021Quote: ... Blood Urea Nitrogen (BUN) and uric acid values were measured photometrically with the Beckman Coulter AU 5800 (Mishima Olympus Co. Ltd., Japan; Beckman Coulter Inc., CA, USA) analyzer ...
-
bioRxiv - Genomics 2020Quote: ... The PCR products were purified by using 1.3X Agencourt AMPure XP beads (2 or 3 cycles; Beckman Coulter) and evaluated by using an Agilent High Sensitivity DNA Kit on an Agilent 2100 Bioanalyzer (Agilent) ...
-
bioRxiv - Cell Biology 2021Quote: ... cell number and volume were measured in a parallel sample using a Multisizer 3 Coulter Counter (Beckman Coulter).
-
bioRxiv - Plant Biology 2021Quote: ... Cell density and mean cell diameter were measured using a Coulter Counter (Multisizer 3, Beckman Counter, Brea, CA). For the data in Figure 1A ...
-
bioRxiv - Molecular Biology 2022Quote: ... sucrose gradient buffer containing NEB75 or NEB300 and centrifuged at 50,000 rpm for 3 h at 4ºC using a TLS-55 rotor (Beckman). After centrifugation ...
-
bioRxiv - Cell Biology 2020Quote: ... containing the phosphatases and proteases inhibitors and centrifuged at 100,000xg for 1 h through a 3 ml 1.4 M sucrose cushion using a TL100 centrifuge (Beckman). The crude heavy nuclear fraction and purified nuclei were resuspended in buffer A and extracted with 1% Triton X-100 for 5 min at 4°C (cNM ...
-
bioRxiv - Microbiology 2019Quote: ... and adding this to 3 ml sterile inoculum water (Beckman Coulter, Inc. Brea, CA, cat no B1015-2) and 840 μl phenol red solution ...
-
bioRxiv - Plant Biology 2023Quote: ... Cell density and mean cell volume were measured using a Coulter Counter (Multisizer 3, Beckman Counter, Brea, CA). For 35°C with photoautotrophic medium ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3 mM BME and centrifuged for 18 h at 30,000 rpm in a Ti 50.2 rotor (Beckman Coulter) at 4°C ...
-
bioRxiv - Immunology 2024Quote: EVs isolated from cells were washed with ultracentrifugation for 3 hours with a SW41 Ti rotor (Beckman Coulter) at 100,000 x g at 4°C ...
-
bioRxiv - Microbiology 2024Quote: ... Four mL cultures at ∼10% parasitemia were harvested by centrifugation (2000 rpm for 3 min in a Beckman Coulter Allegra 25R table-top centrifuge ...
-
bioRxiv - Bioengineering 2024Quote: ... Distribution of microbubble diameter and concentration was acquired with a Coulter counter (Multisizer 3; Beckman Coulter, Fullerton, California) prior to sonication ...
-
bioRxiv - Physiology 2020Quote: The Sfaa was determined through high performance liquid chromatography (HPLC) separation of the free amino acid pool (FAA) and liquid scintillation counting (Beckman Coulter LS 6500, Brea CA) of the alanine elution peak ...
-
bioRxiv - Cell Biology 2020Quote: ... and then the sample was centrifuged at 182,000g for 1 h at 4°C (Beckman SW40). LD fraction was carefully collected from the top band of the gradient and washed three times using 200 μL of buffer B ...
-
bioRxiv - Neuroscience 2021Quote: ... The homogenate was centrifuged at 1,800 rpm for 10 min at 4°C (Beckman F0630 rotor) obtaining a supernatant (S1 ...
-
bioRxiv - Immunology 2019Quote: ... the blood tube was centrifuged in a refrigerated (4°C) centrifuge (Allegra X-15R, Beckman Coulter) at 2000xG for 15 minutes ...
-
bioRxiv - Molecular Biology 2019Quote: ... and centrifuged at 40,000 rpm/4 °C/16 hours using SW 40 Ti rotor (Beckman Coulter). Approximately 18 fractions were collected from each gradient ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (285, 000 g for 2 h at 4 °C using a Beckman SW40Ti rotor), polysome profiles were recorded using an Äktaprime plus chromatography system (GE Healthcare) ...
-
bioRxiv - Biophysics 2021Quote: ... and centrifuged at 200,000 × g for 1.5 h at 4°C in an SW41Ti rotor (Beckman). Fractions (1 ml each ...
-
bioRxiv - Plant Biology 2021Quote: ... reinhardtii cells were collected at 1,870 × g and 4°C for 5 min (JLA9.1000, Beckman Coulter). The cells were resuspended at 0.125 mg Chl/mL with disruption buffer containing 25 mM MES-NaOH (pH 6.5) ...
-
An oscillating MinD protein determines the cellular positioning of the motility machinery in archaeabioRxiv - Microbiology 2020Quote: The cell volume was analyzed with a Multisizer 4 Coulter Counter (Beckman Coulter, Brea, California, USA) equipped with a 30 nm aperture tube ...