Labshake search
Citations for Beckman :
251 - 300 of 1709 citations for Mouse Chemokine C X3 C Motif Receptor 1 CX3CR1 Protein since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Cell Biology 2020Quote: ... followed by serial centrifugation at 100’000 g for 120 min at 10 °C (Beckman fixed-angle TL110 rotor ...
-
bioRxiv - Cell Biology 2020Quote: ... for 15 min at 37°C before analysis using CytoFLEX (Beckman Coulter Life Science). Treatment with 10 µM valinomycin for 30 min was included prior to JC-1 incubation as a depolarising control ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 40 min at 20 000 g (8 °C, 11 300 RPM, Beckman JA-13.1) to run a 30 ml 20% Percoll purification (in 250 mM Sorbitol ...
-
bioRxiv - Microbiology 2020Quote: ... pH 7.4) and centrifuged at 182,000g for 1.5 h at 4°C (Beckman SW40). Then the lipid droplets on the top were collected and washed for further analysis.
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Particle size was measured using dynamic light scattering (DLS; DelsaNano C by Beckman Coulter) where 50 μl of the reaction mixture was taken and added to 5 ml of ethanol which was then centrifuged for 2 minutes before 100 μl of the supernatant was used for DLS analysis ...
-
bioRxiv - Cell Biology 2021Quote: ... at 4°C using the SW 55 Ti Swinging Bucket rotor (Beckman Coulter, 342194).
-
bioRxiv - Molecular Biology 2022Quote: ... After centrifugation at 6000 g for 15 min at 4 °C (JA14 rotor-Beckman), the cell pellet is resuspended with cold lysis buffer (1mg/ml lysozyme ...
-
bioRxiv - Microbiology 2020Quote: ... the VLPs were concentrated by ultracentrifugation (40,000 rpm, 2h, 10°C, Beckman SW41 rotor), resuspended in buffer A and observed by TEM ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... centrifuged at 7500 rpm and 4°C for 20 minutes (J6-MI, Beckman Coulter), and sterilized using 0.2 μm syringe filters (Pall Life Sciences) ...
-
bioRxiv - Microbiology 2019Quote: ... The filtrate was centrifuged for 30 min at 4°C at 4300 rpm (Beckman Coulter X-14R centrifuge with an SX4750 swinging bucket) ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (55,000 rpm, 80 min, 4°C) in a TLS55 rotor (Beckman Coulter), fractions were collected manually for precipitation with trichloroacetic acid (TCA ...
-
bioRxiv - Cell Biology 2021Quote: ... After centrifugation (38,000 rpm, 210 min, 4°C) in an SW41 rotor (Beckman Coulter), RNA content was measured at A254 while fractions were collected using a Foxy Jr ...
-
bioRxiv - Biochemistry 2020Quote: ... and spun at 90,000 rpm for 10 min at 4°C (TLA120.1 Beckman Coulter). After incubation at 37°C for 2 mins ...
-
bioRxiv - Immunology 2020Quote: ... Whole milk was centrifuged at 22°C for 10 minutes at 3,000 g (Beckman Coulter Allegra X-12R ...
-
bioRxiv - Genetics 2022Quote: ... and the final Hi-C library was purified with AMPure XP beads (Beckman Coulter). Promoter Capture Hi-C was performed using a customdesign Agilent SureSelect system following the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2022Quote: ... and centrifuged at 4°C for 30min at 5,000xg and subsequently at 10,000xg (Beckman Coulter Optima XPN-80 with a SW60 rotor) ...
-
bioRxiv - Microbiology 2022Quote: ... The gradient was centrifuged at 100,000 × g for 18 h at 4°C (Beckman-Coulter XPN-80 Ultracentrifuge ...
-
bioRxiv - Microbiology 2023Quote: ... 18°C using an SW40 rotor in an Optima XE-90 ultracentrifuge (Beckman, Germany). The supernatant was discarded and the pellet was resuspended in approximately 50 µl of remaining supernatant.
-
bioRxiv - Physiology 2023Quote: ... Samples were ultracentrifuged at 100,000 rpm at 16°C for 2 hours (rotor: Beckman TLA-100 ...
-
bioRxiv - Plant Biology 2023Quote: ... followed by ultracentrifugation at 4°C for 2 h (38000 rpm, Beckman, SW41 rotor) through a 20-60% sucrose gradient (40 mM Tris-HCl pH 8.4 ...
-
bioRxiv - Biochemistry 2023Quote: ... and cleared by centrifugation at 4°C (18500 rpm, JA-25.50 Beckman, 20 min,). The clarified extract was purified on a 4 ml His60 Ni-IDA Superflow resin (Ozyme ...
-
bioRxiv - Neuroscience 2024Quote: ... for 20 min at 4°C using the pre-cooled 70.1 rotor (Beckman, 342184). Pellets were kept on ice ...
-
bioRxiv - Cell Biology 2024Quote: ... and 10,000 g (30 min, 4 °C, SW28 rotor; Optima XPN Ultracentrifuge, Beckman Coulter) to pellet large EVs52 ...
-
bioRxiv - Cancer Biology 2024Quote: ... 10,000 × g for 30 min) at 4°C (Beckman Coulter Avanti J-E Centrifuge); filtered through a 0.22 μm PES filter (Genesee) ...
-
bioRxiv - Biochemistry 2020Quote: ... The sample was centrifuged at 4°C for 1 hour and 40 minutes at 182,753 x g (38,000 rpm in a Beckman Coulter Type 42.2 Ti rotor).
-
bioRxiv - Molecular Biology 2021Quote: ... 1 mM ATP and 1 mM PMSF) and centrifuged for 15 h at 4°C and 74 400 x g (Beckman SW 32.1 Ti). From the gradient ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... for 10 m at 4°C and pelleted the lysates at 50,000×g for 1 h at 4°C using an Optima MAX-XP ultracentrifuge (Beckman Coulter, Brea, CA, USA). We resuspended cell fractions in 500 μL water and stored the samples at 4°C until analysis ...
-
bioRxiv - Microbiology 2019Quote: ... the extracts were added on top of layers in LCM buffer with 45% and 5% glycerol and ultracentrifuged at 77 000 x g for 1 h at +4°C (Beckman Coulter SW41Ti rotor). Viral nucleocapsids were recovered from the bottom of the ultracentrifuge tube ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... the cell lysate was layered on top of a discontinuous OptiPrep® gradient (50 %, 35 %, 30 %, 20 %, and 15 %) and centrifuged at 135,000 g for 1 h at 4°C (Beckman L8-80M Ultracentrifuge, USA). The melanin pellet was recovered ...
-
bioRxiv - Cell Biology 2020Quote: ... and ultracentrifuged with a 70 Ti rotor (Beckman Coulter; 50,000 rpm, 75 min, 4°C). Supernatants after ultracentrifugation were mixed with COSMOGEL GST-Accept beads (Nacalai Tesque ...
-
bioRxiv - Molecular Biology 2021Quote: ... at 40000 rpm for 30 min at 4°C with a Ti45 rotor (Beckman, USA). Mpro-containing supernatant was applied to an immobilized metal affinity chromatography (IMAC ...
-
bioRxiv - Neuroscience 2021Quote: ... S1 was centrifuged at 30,000 rpm for 30 min at 4°C (Beckman S4180 rotor). The obtained pellet (P2 ...
-
bioRxiv - Genomics 2020Quote: ... and separated by ultracentrifugation at 4°C for 3 hours (35300 rpm, Beckman, SW41 rotor) through a 5-50% sucrose gradient (40 mM Tris-HCl pH 8.4 ...
-
bioRxiv - Biochemistry 2019Quote: ... After ultra-centrifugation (SW-60Ti rotor Beckman Coulter, 2 h, 100 000 rpm, 4°C) the gradient was manually fractioned in 200 μl fractions from the top to the bottom of the tube ...
-
bioRxiv - Biochemistry 2020Quote: ... the filtered cell culture fluid was ultracentrifuged (25k rpm, 4 °C, SW55Ti Rotor, Beckman Coulter) through a 20% sucrose cushion prepared in TNE buffer (10 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2021Quote: ... and concentrated by ultracentrifugation (100,000 × g, 90 min 4 °C, SW41, Beckman Coulter, Brea, CA). The pellet was resuspended in reducing Laemmli SDS-PAGE sample buffer ...
-
bioRxiv - Biophysics 2021Quote: ... Cell debris was removed by centrifugation (Beckman Avanti, 45 min, 40,000 x g, 4 °C) and supernatants were diluted 3-fold in 20 mM Tris pH 8.0 ...
-
bioRxiv - Cell Biology 2020Quote: ... and ultracentrifuged with a 70 Ti rotor (Beckman Coulter; 50,000 rpm, 75 min, 4°C). The supernatants were mixed with COSMOGEL GST-Accept beads (Nacalai Tesque ...
-
bioRxiv - Bioengineering 2022Quote: ... samples (10 mL) were first centrifuged at 7000Xg at 4°C for 30 minutes (Beckman Coulter Avanti J-E Series ...
-
bioRxiv - Biochemistry 2021Quote: ... The bacterial culture was centrifuged at 4,000 × g for 15 min at 4°C (Beckman) and the cell pellet was resuspended in 30-40 mL of lysis buffer (50 mM HEPES pH 8.0 ...
-
bioRxiv - Cell Biology 2019Quote: ... and ultracentrifuged with a 70 Ti rotor (Beckman Coulter; 50,000 rpm, 75 min, 4°C). The supernatants obtained (around 40 ml each ...
-
bioRxiv - Biochemistry 2019Quote: ... All measurements were performed at 37°C by connecting the fluorimeter (DU 640 Spektrometer, Beckman) to a water bath ...
-
bioRxiv - Physiology 2019Quote: ... and spun at 100,000xg for 20m at 4°C in Optima Max ultracentrifuge (Beckman Coulter). Tubes were carefully removed from the ultracentrifuge with forceps and 30 uL of supernatant was removed to a PCR tube with every care taken to avoid the protein pellet ...
-
bioRxiv - Cancer Biology 2019Quote: ... held at 4 °C) and then cleaned up with the SPRIselect Reagent Kit (Beckman Coulter). A qualitative analysis on the amplified cDNA was performed using Agilent Bioanalyzer high sensitivity chip.
-
bioRxiv - Neuroscience 2021Quote: ... at 25000 rpm (SW28, 4°C) in an 80K ultracentrifuge (Beckman Coulter; Brea, California, USA). After centrifugation ...
-
bioRxiv - Genetics 2019Quote: ... at 20°C for 16 hours at 45,000 rpm in a VTi 65 rotor (Beckman). Ethidium bromide was extracted from the CsCl banded DNA using water-saturated n-butanol ...
-
bioRxiv - Immunology 2020Quote: ... at 5,000 g for 30 minutes at 4°C and subsequently at 10,000 g (Beckman Coulter Optima L-90K with a SW40Ti rotor) ...
-
bioRxiv - Biophysics 2021Quote: ... 2mM MgCl) centrifuged for 16 hours at 35k rpm at 4 °C (Beckman TLS-55). 80S ribosome was found to have formed a pellet at the bottom of the tube and was resuspended in 20mM HEPES pH 7.9 ...