Labshake search
Citations for Beckman :
251 - 300 of 446 citations for H D Glu amc oh since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2021Quote: ... The thylakoid membranes with different densities were analytically separated at 125,000 × g and 4°C for 1 h (SW 41 Ti, Beckman Coulter).
-
bioRxiv - Microbiology 2021Quote: ... pspAX.2 and oligonucleotides were incubated for 48 h and GFP expression level was analyzed by CytoFLEX flow cytometer (Beckman).
-
bioRxiv - Neuroscience 2020Quote: ... The remaining supernatant (conditioned medium) was subjected to ultracentrifugation (UC) (100,000 x g 1 h) using rotors Ti45 or SW32Ti (Beckman Coulter). The pellet was rinsed with PBS and spun again using rotor SW55Ti (100,000 x g 1 h).
-
bioRxiv - Neuroscience 2022Quote: ... The remaining supernatant (conditioned medium) was subjected to ultracentrifugation (UC) (100,000 x g, 1 h) using rotors Ti45 or SW32Ti (Beckman Coulter). The pellet was rinsed with PBS and spun again using rotor SW55Ti (100,000 x g ...
-
bioRxiv - Neuroscience 2022Quote: ... The gradient was subjected to high-speed centrifugation at 100,000 x g for 2 h at 4° C using a SW41Ti rotor (Beckman Coulter). 12 fractions of 1ml each were collected from the top of the gradient ...
-
bioRxiv - Neuroscience 2022Quote: ... 10 mM Tris-HCl) and centrifugated at 24,000 rpm for 1 h at 4°C in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). Supernatant was discarded and nuclei pellets were re-suspended in 800 µL of PBS ...
-
bioRxiv - Cell Biology 2020Quote: ... The supernatant of MNase treated chromatin were overlaid onto the sucrose gradient and spun at 32000 rpm (124,436 rcf) for 13 h at 4 °C using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80.
-
bioRxiv - Cell Biology 2020Quote: ... 1 mM EGTA) and spun at 32000 rpm (124,436 rcf) and 4 °C for 13 h using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80 ...
-
bioRxiv - Cell Biology 2021Quote: ... The samples were centrifuged at 4°C for 3 h at 100,000 g by using Avanti J-30XP (Beckman, USA), and the fractions were collected using a Brandel Fractionation System (USA ...
-
bioRxiv - Biophysics 2021Quote: ... Cells were lysed and the lysate was clarified by centrifugation for 1 h at 100,000g (45 Ti rotor, Beckman Coulter). The clarified lysate was incubated with Ni2+-NTA agarose resin for 1 h at 4 °C ...
-
bioRxiv - Microbiology 2020Quote: ... The cell lysate was collected and centrifuged at 100,000 x g for 1 h in an ultracentrifuge (Model XL-90, Beckman Coulter). The supernatant was collected ...
-
bioRxiv - Biochemistry 2020Quote: ... Protein-liposome complexes were separated from unbound protein by centrifugation (2 h at 45.000 rpm, 4 °C, MLS50 rotor -Beckman Coulter) in the density gradient ...
-
bioRxiv - Molecular Biology 2021Quote: ... lysates were spun for 24 h at 4°C at 50000 rpm in a Type 70 Ti rotor (Beckman Coulter) through a 40 % (w/v ...
-
bioRxiv - Immunology 2020Quote: ... all CCMV CP preparations were purified two times using an ultracentrifuge and 30% sucrose cushion – first with additional 0.5% Triton X-100 and the second time without Triton X-100 (4 h, 50 000 rmp, 4°C; Type 70Ti rotor, Beckman) and the pellet was then dissolved in buffer A ...
-
bioRxiv - Biochemistry 2020Quote: ... incubated under constant shaking at 37°C taken at various time points (24, 72, 168 h) were centrifuged (TL-100, Beckman) at 50k RPM (100,000 ×g ...
-
bioRxiv - Systems Biology 2023Quote: ... Gradients were centrifuged at 4°C for 17 h at 100,000 g using an L7 ultracentrifuge with an SW28 swing out rotor (Beckman Coulter). Fractions (F ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was centrifuged at 300,000×g at 4°C for 3 h in a TLA-110 fixed angle rotor (k-factor 13) (Beckman Coulter). The pellet was resuspended in 10 µL PBS of which 3 µL was adsorbed onto glow-discharged 2 nm carbon layer coated Quantifoil R1.2/1.3 400 mesh gold grids ...
-
bioRxiv - Cell Biology 2022Quote: ... 4–40% sucrose gradient prepared in lysis buffer and centrifuged at 150,000 × g for 4 or 16 h at 4°C in a MLS-50 rotor (Beckman Coulter). Thereafter ...
-
bioRxiv - Cell Biology 2023Quote: ... Each fraction was subjected to a washing step in ice-cold PBS at 100,000 × g at 4°C for 2 h using a SW28Ti rotor (Beckman Coulter). The pelleted EVs were resuspended in ice-cold PBS ...
-
bioRxiv - Microbiology 2023Quote: ... Not solubilised protein was removed by a second pelleting at 100×kg for 1 h in Ti70 rotor (Beckman Coulter). The solubilized and denatured protein was loaded on a 5 ml HisTrap HP column (Cytiva) ...
-
bioRxiv - Molecular Biology 2023Quote: ... and ultracentrifuged in a sucrose cushion at 100,000 rpm at 4°C for 1 h with a TLA110 rotor (Beckman Coulter). The ribosome pellet was dissolved in TRIzol reagent (Thermo Fisher Scientific) ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was ultracentrifuged at 100,000 ×g at 4 °C for 2 h using an Optima XE-90 (Beckman Coulter) to collect EMVs ...
-
bioRxiv - Cancer Biology 2022Quote: ... Fractions 2–9 were diluted 1:10 in PBS and centrifuged at 20,000 ×g (bEVs) or 100,000 ×g (sEVs) at 4°C for 1 h with an MLS-55 rotor (Beckman Coulter). The bEV and sEV pellets were suspended in double 0.22-µm-filtered PBS and were either used directly for experiments or stored in aliquots at −80°C until subsequent BLI ...
-
bioRxiv - Molecular Biology 2023Quote: 8 mL of viral supernatant on a 3 mL of 20% sucrose cushion were ultracentrifugated for 3 h at 100,000 x g at 4°C using an Optima L80-XP instrument (Beckman Coulter). After ultracentrifugation ...
-
bioRxiv - Biophysics 2023Quote: ... the supernatant of cell lysates was centrifuged to isolate the total membrane fraction at 24,000 rpm for 2 h in the 45Ti rotor using ultracentrifuge (Beckman-Coulter). Membrane resuspension in 50 mM Tris-HCl buffer (pH 8.0 ...
-
bioRxiv - Neuroscience 2023Quote: ... This supernatant was next subjected to ultracentrifugation at 120,000 x g for 2 h at 4LJ in a SW 41 Ti Rotor Swinging-Bucket rotor (Beckman Coulter), and the pellets collected as small factors like exosome ...
-
bioRxiv - Neuroscience 2023Quote: ... The lysate was separated into soluble and insoluble fractions by ultracentrifugation at 100,000 x g for 1 h using Optima L-XP (Beckman Coulter). The soluble fraction was filtered using a bottle-top 0.22-µm filter (Corning) ...
-
bioRxiv - Plant Biology 2023Quote: ... It was then centrifuged again at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The final pellet containing the purified EV fraction was resuspended in 50 µl of 20 mM Tris-HCl pH 6.0 ...
-
bioRxiv - Plant Biology 2023Quote: ... at 10,000 x g for 1 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor ...
-
bioRxiv - Cell Biology 2023Quote: ... loaded onto a discontinuous 0.75/1.0/2.33 M sucrose gradient and spin at 242,000 g for 1 h at 4 °C in a SW32Ti rotor (Beckman & Coutler). Growth cone fractions were collected at the interface load/0.75 M sucrose and non-growth cone fractions collected between 0.75/1.0 M sucrose and then analyzed by Western Blot.
-
bioRxiv - Cell Biology 2023Quote: ... The obtained supernatant was layered onto 30 w/v% sucrose solution in ultracentrifugation tubes and subjected to ultracentrifugation at 100,000 × g for 3 h at 4°C using SW32Ti rotor (Beckman courter). The collected sucrose solutions were mixed with PBS and washed by ultracentrifugation at 100,000 × g for 1 h ...
-
bioRxiv - Cell Biology 2023Quote: ... The density adjusted FBS was subjected to ultracentrifugation for 25 h at 310,500 x g at 10°C in a 70Ti rotor (Beckman Coulter) before dialysis ...
-
bioRxiv - Molecular Biology 2023Quote: ... Ribosomes were isolated by sucrose cushion ultracentrifugation at 100,000 rpm at 4°C for 1 h using TLA110 rotor (Beckman Coulter). RNAs in the ribosome pellet were isolated with TRIzol-LS (Thermo Fisher Scientific ...
-
bioRxiv - Plant Biology 2023Quote: ... Approximately 250 µl of crude EV sample resuspended in 20 mM Tris-HCl pH 6.0 was slowly dispensed on top of the column and centrifuged at 100,000 x g for 17 h at 4 ⁰C (SW 41 Ti rotor, Beckman Coulter; OptimaTM L-90K, Beckman Coulter). After the ultracentrifugation ...
-
bioRxiv - Plant Biology 2023Quote: ... The resulting solution was then centrifuged again at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was decanted ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was then decanted and discarded ...
-
bioRxiv - Plant Biology 2023Quote: ... The tubes were then centrifuged at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The pellets from the tubes were pooled together in 500 µl of 20 mM Tris-HCl pH 6.0 buffer and the volume was brought up to 1,500 µl using 20 mM Tris-HCl ...
-
bioRxiv - Molecular Biology 2022Quote: ... The gradients were ultra-centrifuged for 3 h at 175,000g at 4°C in a SW41Ti rotor (Beckman-Coulter, USA) and analyzed by measuring the absorbance continuously at 260 nm using a piston gradient fractionator (Biocomp Instruments) ...
-
bioRxiv - Cell Biology 2022Quote: ... to obtain a high percentage of transfected cells 24 h post-transfection GFP expressing cells were FACS sorted by MoFlo Astrios (Beckman). Following sorting total RNA was prepared ...
-
bioRxiv - Biochemistry 2024Quote: ... The protein samples were carefully applied to the gradient and centrifuged for 16 h at 130,000 g at 4 °C (Optima XPN-80 Ultracentrifugation from Beckman Coulter). 200 µl fractions were taken from the top of the gradient and the glutaraldehyde quenched with 20 mM Tris pH 7.5 ...
-
bioRxiv - Molecular Biology 2024Quote: ... Lysates were cleared by centrifugation for 1 h at 45,000 rpm at 4°C (Optima XPN-80 Ultracentrifuge with 70 Ti, Beckman Coulter). HTP-tagged proteins were immunoprecipitated with 600 µl pre-washed IgG-sepharose 6 fast flow affinity resin (GE Healthcare ...
-
bioRxiv - Cell Biology 2024Quote: ... Gradients were centrifuged at 36,000 rpm for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Following centrifugation ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was ultracentrifuged at 80,000 × g for 1 h at 4°C using a type 50 Ti rotor ultracentrifuge (Beckman Coulter). The supernatant ...
-
bioRxiv - Cell Biology 2023Quote: ... The gradient was centrifuged at 4 °C and 100,000 ˗ g for 18 h (Optima L-80 XP Ultracentrifuge with Swing Rotor (Beckman Coulter)) ...
-
bioRxiv - Cell Biology 2023Quote: ... tared and ultracentrifuged for 1 h at 110,000x g using a Beckman L7-65 ultracentrifuge with a SW41Ti rotor (#331362, Beckman Coulter). After ultracentrifugation ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Cell Biology 2024Quote: ... The step gradients were centrifuged for 5 h at 132.000 x g at 4 °C (SW60 Beckman and Coulter, # 335649). Subsequently ...
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Neuroscience 2024Quote: ... Digested samples were ultracentrifuged at 100,000x g for 1 h at 4 °C using a TLA-55 rotor (Beckman Coulter) to concentrate the insoluble ...