Labshake search
Citations for Beckman :
201 - 250 of 1603 citations for tert Butyl trans 17 bromo 4 7 10 13 tetraoxa 15 heptadecenoate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... the SBV samples were purified via sucrose density gradient centrifugation (10–50% range) at 32,500 rpm for 4 h with an SW 41 Ti Swinging-Bucket Rotor (Beckman Coulter Inc., Brea, CA). The SBV band that corresponded to the 40% sucrose gradient was harvested and then centrifuged at 25,000 rpm for 12 h ...
-
bioRxiv - Microbiology 2024Quote: ... The supernatant was collected and treated with polyethyleneimine to a final concentration of 0.03% incubated on ice for 5 minutes and subsequently centrifuged at 10,000 rpm at 4°C for 10 minutes (Beckman coulter, JA-25.50 rotor). The supernatant was collected and powdered ammonium sulfate (approx 15 g ...
-
bioRxiv - Microbiology 2024Quote: ... was added to the supernatant on ice with constant stirring until protein precipitate was observed followed by centrifugation at 10,000 rpm at 4°C for 10 minutes (Beckman coulter, JA-25.50 rotor). The pellet was resuspended in 4 ml of binding buffer (20 mM Tris-HCl ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4°C (Beckman Coulter). The pellet containing lentiviral particles was suspended in the residual medium ...
-
bioRxiv - Genomics 2020Quote: ... 4°C (Beckman Coulter). Supernatant was loaded onto 5 ml HisTrap FF columns (GE Healthcare ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4°C (Beckman Coulter). Clarified lysates were poured several times over 0.5-1 ml Streptactin resin (IBA ...
-
bioRxiv - Cancer Biology 2023Quote: ... 4°C (Beckman Coulter). The pellet containing lentiviral particles was suspended in the residual medium ...
-
bioRxiv - Neuroscience 2022Quote: ... which was then sealed and placed into a hematocrit spinner (2 minutes at 13, 700 g; StatSpin CritSpin Microhematocrit Centrifuge, Beckman Coulter, Inc). Measurements were taken to calculate percent (% ...
-
bioRxiv - Microbiology 2024Quote: ... Peptidoglycan was obtained by centrifuging for 13 min at 60,000 rpm at 20 °C (TLA100.3 Beckman rotor; OptimaTM Max ultracentrifuge Beckman, Beckman Coulter, California, USA). Pellets were washed 3-4 times by repeated cycles of centrifugation and resuspension in water ...
-
bioRxiv - Cell Biology 2020Quote: ... PEG was removed via centrifugation at 136,000 xg for 7 minutes in TLA100.3 (Beckman Ultracentrifuge), and supernatant was pre-cleared by incubating with Protein A Sepharose beads (GE LifeSciences #17127901 ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were transferred to 7 x 20mm polycarbonate thick-wall tubes (Beckman Coulter, Krefeld, Germany) for ultra-centrifugation (centrifuge Optima TLX with rotor TLA 100 ...
-
bioRxiv - Cancer Biology 2023Quote: ... After 5-7 days cells were counted using a Z1 Coulter Particle Counter (Beckman Coulter).
-
bioRxiv - Cell Biology 2024Quote: ... The gradients were prepared in 7 x 20 mm centrifuge tubes (Beckman Coulter, Cat#343775) by successively layering 40 µL each of 25% ...
-
bioRxiv - Plant Biology 2024Quote: ... placed inside 250 mL centrifuge bottles and centrifuged for 10 min at 100 g at 4 °C (JA-14 rotor, Avanti J-20 XP Centrifuge; Beckman Coulter, Indianapolis, IN, USA). LSW was then filtered through a 0.2 µm syringe filter (Acrodisc syringe filter ...
-
bioRxiv - Microbiology 2024Quote: ... of each culture or 20 µL of each DMB was added to 13 x 51 mm polypropylene centrifuge tubes (Beckman Coulter, Sykesville, MD) containing 3 mL of Working Percoll Solution (WPS) ...
-
bioRxiv - Biophysics 2024Quote: ... and centrifuged for 15 h at 25,000 rpm (Beckman SW 32 rotor). The fractions enriched with AE1 protein were collected and incorporated into lipid nanodiscs with a 1:5:250 molar ratio of protein ...
-
bioRxiv - Biochemistry 2020Quote: ... A Multisizer 4 (Beckman Coulter) machine was used ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C (SW55Ti rotor, Beckman). The pellets were resuspended in 25% (w/v ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C (VTi65.1 rotor, Beckman) with the maximum acceleration and minimum deceleration allowing for isopycnic separation of subcellular particles and membranes ...
-
bioRxiv - Biochemistry 2021Quote: ... 4°C (SW41 rotor, Beckman). The supernatant was concentrated with a 100-kDa molecular weight cutoff concentrator (Merck Millipore ...
-
bioRxiv - Cell Biology 2024Quote: ... 4-laser Gallios (Beckman Coulter) flow cytometer ...
-
bioRxiv - Biophysics 2022Quote: ... Labeled G-actin was clarified to remove any remaining F-actin or precipitated FMAL by centrifugation (10 min, 90,000 rpm in a Beckman TLA-120.2 rotor at 4°C). The extent of labeling (typically around 70% ...
-
bioRxiv - Microbiology 2024Quote: ... Virus was collected 48 hours post-transfection and pelleted over a 10% sucrose cushion at 25,000 RPM for 2 hours at 4 °C using a SW32Ti rotor (Beckman Coulter Life Sciences, Brea, CA, USA). Pellets were resuspended in DMEM (Gibco ThermoFisher Scientific ...
-
bioRxiv - Microbiology 2020Quote: ... Unsieved soil samples were suspended in water and analyzed on a LS 13 320 Series Laser Diffraction Particle Size Analyzer (Beckman Coulter Brea CA 92821). Particle sizes were grouped according USDA soil texture classification ...
-
bioRxiv - Cell Biology 2021Quote: ... The homogenized solution was centrifuged at 75,000 rpm for 15 min (Beckman, TL100.3). The supernatant was loaded onto a StrepTactin Sepharose column with a volume of 1 mL ...
-
bioRxiv - Cell Biology 2023Quote: ... continuous 15-45 % (w/v) sucrose gradients were prepared in SW41 tubes (Beckman) in Polysome Gradient Buffer (10 mM Hepes-KOH ...
-
bioRxiv - Molecular Biology 2023Quote: ... Lysates were loaded on 15-50% sucrose density gradients and centrifuged (Beckman ultracentrifuge) for 1 hour and 30 minutes in a SW41Ti swinging bucket rotor at 39000 rpm at 4 °C ...
-
bioRxiv - Immunology 2024Quote: ... The mixtures were purified 15 μL of AMPure XP SPRI beads (Beckman Coulter) diluted two-fold with Pooling buffer (20% PEG8000 ...
-
bioRxiv - Biophysics 2024Quote: ... The homogenized solution was centrifuged at 75,000 rpm for 15 minutes (Beckman, TL100.3). The supernatant was loaded onto a StrepTactin Sepharose column (IBA ...
-
bioRxiv - Microbiology 2024Quote: ... Cells were harvested at 4000 × g for 15 min (Microfuge 20R, Beckman Coulter) and resuspended in PBS ...
-
bioRxiv - Immunology 2023Quote: ... lysates were fractionated on a linear sucrose gradient (7–47%) using the SW-41Ti rotor (Beckman Coulter) at 221,633x g for 2lllhours at 4 °C ...
-
bioRxiv - Biophysics 2024Quote: ... and then centrifuged at 250,000 g for 7 min at 37 °C in a TLA100 rotor (Beckman). The pellet was then resuspended in a bright tubulin mix containing 7.5 mM unlabeled tubulin ...
-
bioRxiv - Plant Biology 2024Quote: ... were carefully removed starting from the top of the gradient using a pipet and transferred to a polycarbonate tube (Beckman 13 x 51 mm, #349622). The density of each fraction was determined either by weighing the fraction and dividing by the volume ...
-
bioRxiv - Cancer Biology 2021Quote: ... 4°C (Beckman Coulter Allegra X15r). After the final wash to remove Matrigel ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4°C (SW41Ti rotor, Beckman Coulter) and 16 fractions were collected ...
-
bioRxiv - Molecular Biology 2021Quote: ... 4°C (SS34 Rotor, Beckman Coulter).
-
bioRxiv - Cell Biology 2020Quote: ... 4°C (with Beckman SW32 rotor). The pellet will contain rough microsomes and the interface between 0.25-1.3M will contain smooth microsomes ...
-
bioRxiv - Neuroscience 2021Quote: ... 4°C (Beckman Coulter F301.5 rotor) to remove large aggregates ...
-
bioRxiv - Biophysics 2023Quote: ... 4 °C (TLA-45 Beckman rotor). The solubilized proteins were separated on 4–15 % BN-gels and analyzed by immune detection using polyclonal α-YidC antibodies ...
-
bioRxiv - Cancer Biology 2021Quote: ... Purified cDNA was amplified for 15 cycles and cleaned up using SPRIselect beads (Beckman). Samples were quantified on an Invitrogen Qubit 4 Fluorometer ...
-
bioRxiv - Cell Biology 2020Quote: ... for 15 min at 37°C before analysis using CytoFLEX (Beckman Coulter Life Science). Treatment with 10 µM valinomycin for 30 min was included prior to JC-1 incubation as a depolarising control ...
-
bioRxiv - Genomics 2020Quote: ... Purified cDNA was amplified for 15 cycles before bead cleanup using SPRIselect beads (Beckman). Samples were quantified using an Invitrogen Qubit 4 Fluorometer ...
-
bioRxiv - Molecular Biology 2022Quote: ... Cells were harvested by centrifugation for 15 minutes in a JLA-9.1000 rotor (Beckman) at 5,180 x g and the pellets were stored at –20 °C.
-
bioRxiv - Genetics 2021Quote: ... 15-60% sucrose gradients were prepared in 89 mm polypropylene centrifuge tubes (Beckman Coulter) using standard settings on a Foxy Jr ...
-
bioRxiv - Microbiology 2021Quote: ... and centrifuged each time at 4000 × g for 15 min (Microfuge 20R, Beckman Coulter) followed by resuspension in PBS.
-
bioRxiv - Genomics 2023Quote: ... the cDNA was cleaned up and eluted into 15 µL using AMPure beads (Beckman) following the manufacturer’s protocol ...
-
bioRxiv - Immunology 2023Quote: A 15-45% continuous sucrose gradient was made in Thinwall polyallomer tubes (Beckman Coulter) from 15% and 45% sucrose (MP Biomedicals ...
-
bioRxiv - Neuroscience 2021Quote: ... KG, Staufen, Germany) (position 6, 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge ...
-
bioRxiv - Microbiology 2020Quote: ... 4°C in an SW55Ti rotor (Beckman), and the virus pellet harvested for analysis by WB with αGag.
-
bioRxiv - Cell Biology 2020Quote: ... 4 °C with 70Ti rotor (Beckman Coulter) to collect sEV pellets in double 0.22 μm-filtered PBS ...