Labshake search
Citations for Beckman :
201 - 250 of 585 citations for 3 Iodo 2 6 dimethyl benzoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2020Quote: ... The harvested sEVs were resuspended with 3 mL double filtered PBS and centrifuged with MLA-55 rotor (Beckman Coulter) under 100,000 × g at 4 °C for 70 mins to remove non-EV contaminants ...
-
bioRxiv - Microbiology 2023Quote: ... The tube was centrifuged for 3 hours at 150’000 x g (4°C) using a SW 32.1 Ti swinging bucket (369651, Beckman Coulter). Finally ...
-
bioRxiv - Neuroscience 2022Quote: ... myelin was layered onto 3 mL ice cold 0.85 M sucrose solution in a 10 mL ultracentrifuge tube (Beckman) before centrifugation at 75 000 x g for 30 min at 4 °C on a Beckman Ultracentrifuge with MLA-55 rotor (acceleration 7 ...
-
bioRxiv - Neuroscience 2023Quote: ... the liposomes were isolated by centrifugation for 3 h 40 mins at 55,000 rpm at 4°C in a SW 60 rotor (SW 60 Ti, Beckman). 20 µl were harvested from the top of the gradient and mixed with 8 µl of 4x Laemmli buffer (final 62.5 mM Tris-HCl ...
-
bioRxiv - Microbiology 2023Quote: ... and RNA were purified using 3 volume of absolute isopropanol and 1.8 volume of Agencourt RNAClean XP beads (Beckman). RNA was eluted with 6 µL of water ...
-
bioRxiv - Plant Biology 2024Quote: ... and centrifuged for 3 h at 260,000 g using an SW 55 Ti swinging-bucket rotor (Beckman Coulter, USA). The final supernatant was discarded ...
-
bioRxiv - Biochemistry 2022Quote: ... The membrane was solubilized for 3 hours at 4°C before separation by ultracentrifugation at 100,000 g (Ti45, Beckman) for 45 min ...
-
bioRxiv - Neuroscience 2022Quote: ... supernatant was centrifuged for 3 h at 115,000 g and 4°C using the XPN-80 ultracentrifuge equipped with a Ti70 rotor (Beckman). EV pellets were resolved in 1 mL ice-cold PBS (Gibco ...
-
bioRxiv - Cell Biology 2023Quote: ... 0.01% Sodium Azide in PBS and measured by recording 3 × 104 events using CytoFLEX and Gallios cytometers (Beckman Coulter). The resulting data were analysed using FlowJo v10 (TreeStar) ...
-
bioRxiv - Cancer Biology 2022Quote: ... cells were treated with 20nM of gemcitabine and cells were counted 3 days later using the Z1 Coulter (Beckman).
-
bioRxiv - Bioengineering 2023Quote: ... MB concentration and number- and volume-weighted size distributions were measured using a Multisizer 3 Coulter Counter (Beckman Coulter). MB concentration (𝑐i ...
-
bioRxiv - Microbiology 2024Quote: ... the supernatants were loaded onto 1 mL of 30% sucrose in PBS buffer and centrifuged at 25,000 rpm at 4°C for 3 hours using the 90AT rotor (Beckman). The pelleted viral particles were resuspended in 100 μL of PBS and fixed with formaldehyde (working concentration 0.1% ...
-
bioRxiv - Neuroscience 2024Quote: ... Tubes were centrifugated at 100,000 x g (32,500 RPM) for 3 hours at 4°C using a SW55Ti rotor (Beckman Coulter). Synaptosomes enriched in the interface between 1.0-1.25 M sucrose were collected and diluted with ice-cold 0.1 mM CaCl2 ...
-
Syntaxin-2 inhibits excessive phagocytic uptake but promotes phagolysosomal clearance in macrophagesbioRxiv - Cell Biology 2024Quote: ... followed by sequential topping with 2 mL each of 35, 25, and 10% sucrose (all prepared in 3 mM imidazole, pH 7.4) in SW40 tubes (344060, Beckman). The samples were then centrifuged at 100,000 g for 1 hr at 4°C using a SW40Ti rotor (Beckman) ...
-
bioRxiv - Bioengineering 2024Quote: ... the distribution of microbubble diameter and concentration was assessed using a Coulter counter (Multisizer 3; Beckman Coulter, Fullerton, California). T1 mapping MRI sequences were used to guided sonication targeting ...
-
bioRxiv - Cell Biology 2024Quote: ... The 100,000xg SEV-containing pellets were resuspended in 3 ml sterile cold PBS and repelleted at 100,000xg for 4 hrs in a TLA110 rotor (Beckman). SEVs were analyzed for size and number by nanoparticle tracking (ZetaView ...
-
bioRxiv - Biophysics 2024Quote: ... The virus was pelleted from supernatants via centrifugation at 14000 rpm for 6 hours at 4°C using a Beckman J2-21 high-speed ultracentrifuge fitted with a JA14 rotor (Beckman Coulter Inc., Fullerton, CA, USA). After carefully removing supernatants ...
-
bioRxiv - Genetics 2022Quote: ... uric acid and urea were measured on a UniCel® DxC 800 Synchron® Clinical System or AU480 Clinical Chemistry System (Beckman Coulter, Brea, CA, USA) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... Centrifugation was performed at 120,000 × g for 2 hr (Beckman TLS 55 rotor), after which the interface between 0.25 M and 1.1 M sucrose was collected and resuspended in 1 ml 19% OptiPrep for a step gradient containing 0.5 ml 22.5% ...
-
bioRxiv - Cell Biology 2022Quote: ... 2× – G2) was interrogated using a using a Gallios flow cytometer (Beckman Coulter) and subsequent data analysis with FlowJo (v.10.8.0) ...
-
bioRxiv - Neuroscience 2020Quote: ... Cells were centrifuged at 1500 rpm for 2 minutes (Beckman Allegra X15R, 524xg), supernatant was removed and tissue was carefully triturated using fire-polished glass pipettes with 2 mL pre-warmed media ...
-
bioRxiv - Synthetic Biology 2021Quote: PCR products were purified with 2 volumes of RNAClean XP beads (Beckman Coulter) and then quality-checked and quantified on a Bioanalyzer (Agilent) ...
-
bioRxiv - Immunology 2024Quote: ... and 2 mM DTT) and separated by ultracentrifugation at 148,900xg (Ti55 rotor, Beckman) for 1.5 hours at 4°C ...
-
bioRxiv - Genetics 2024Quote: ... DNA was further purified using 2 volumes of Ampure XP beads (Beckman Coulter). DNA was extracted from 10000 undifferentiated or differentiated spermatogonia cell samples by QIAamp DNA Micro Kit (Qiagen # 56304 ...
-
bioRxiv - Molecular Biology 2023Quote: ... The ribodepleted RNA was cleaned using 2× RNAClean XP beads (Beckman Coulter A63987), eluting with 20 μL DNase digestion reaction mixture (1.5 μL Turbo DNase (Invitrogen AM2238) ...
-
bioRxiv - Synthetic Biology 2023Quote: ... cells were diluted 2-fold with PBS and analysed with CytoFLEX S (Beckman Coulter ...
-
bioRxiv - Biophysics 2022Quote: ... 2 mM DTT) with 0.7 M sucrose in Ti-45 tubes (Beckman-Coulter). The tubes were then placed in a Ti-45 rotor and spun at 27,000 rpm (57,000 xg ...
-
bioRxiv - Biophysics 2022Quote: ... 2 M urea) by resuspension and centrifugation on a JS-4.2 rotor (Beckman) at 6,000 RPM for 30 minutes ...
-
bioRxiv - Cell Biology 2024Quote: ... 2 mg/ml Proteinase K) and normal phase 2x AMPureXP (Beckman Coulter, #A63881) bead clean-up ...
-
bioRxiv - Neuroscience 2024Quote: ... for 2 h using 25 ξ 89 mm polycarbonate tubes (Beckman Coulter, 355618). Pellets were resuspended in 500 μL of sterile phosphate-buffered saline (PBS ...
-
bioRxiv - Neuroscience 2024Quote: ... for 2 h using 16 ξ 76 mm polycarbonate tubes (Beckman Coulter, 355603). The resulting pellets were resuspended in 250 μL of sterile PBS ...
-
bioRxiv - Biochemistry 2024Quote: ... Step 2 PCR was cleaned up using Agencourt AMPure XP beads (Beckman Coulter), and final DNA concentration was measured using the Invitrogen Quant-IT dsDNA High-Sensitivity HS Assay kit quantified with a BioTek Synergy H1 Multimode Microplate Reader before pooling libraries for sequencing ...
-
bioRxiv - Genomics 2024Quote: ... PCR 2 products were purified by DNA AMPure XP beads (Beckman Coulter #A63882) and eluted with 25 uL of water ...
-
bioRxiv - Microbiology 2020Quote: ... and overlaid with 6 ml of 30% and 3 ml of 5% sucrose (w/v) followed by centrifugation at 32,000 rpm in SW41 rotor (Beckman Coulter) for 20 h ...
-
bioRxiv - Molecular Biology 2020Quote: ... Debris was clarified by centrifuging at 18,000 ×g followed by fractionation on a discontinuous sucrose gradient (10-50 %) by ultracentrifugation at 39,000 rpm for 3 h in an SW41-Ti rotor (Beckman coulter). Monosome fractions were collected by pumping of Fluorinert FC-40 and using a fraction collector by measuring UV trace ...
-
bioRxiv - Molecular Biology 2020Quote: ... The gradient was formed by adding 3 mL of the iodixanol solutions to a 17 mL polypropylene tube (Beckman Coulter). Ultracentrifugation was performed using a SW Type 32.1 Ti rotor in Optima XPN-100 Ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Cancer Biology 2020Quote: The barcode split of the cDNA amplification reaction (from 10x Single Cell 3’ v3 Step 2.2) was purified via 1.2x SPRI Select (Beckman Coulter #B23317). cDNA products were eluted in 40 µL of EB ...
-
bioRxiv - Neuroscience 2020Quote: ... reverse 5’-CTTA TTAGTCAGTCAGAAACAAC-3’).ThePCR amplicon was purified using RNAse-free SPRI beads (Agencourt RNAclean XP, Beckman-Coulter A63987) and then used for in vitro transcription with the HiScribe T7 ARCA mRNA Kit (with tailing ...
-
bioRxiv - Microbiology 2021Quote: 3 mL of pseudoparticles were pelleted using a TLA-55 rotor with an Optima-MAX-E ultracentrifuge (Beckman Coulter, Inc.) for 2 hours at 42,000 rpm at 4°C ...
-
bioRxiv - Microbiology 2020Quote: ... Supernatants (3 ml) were loaded on the top of step gradients preformed in polyallomer tubes (14 by 89 mm, Beckman), containing 2 ml each of 1.82 ...
-
bioRxiv - Molecular Biology 2020Quote: ... 1.3 M, 2.5 M) as indicated in the method (Vella et al., 2017) in ultra-clear SW40Ti tubes (Beckman Coulter). The sucrose gradients were centrifuged at 200,000 x g avg at 4°C for 173 min using a SW40Ti rotor (Beckman Coulter) ...
-
bioRxiv - Microbiology 2020Quote: ... was overlaid on 25% sucrose in PBS and centrifuged at 26,000 rpm for 3 h at 4C using SW28 rotor (Beckman Coulter). Pellets were dissolved in PBS overnight at 4C and 1/3 of used for RNA was extraction using Macherey Nagel Virus RNA isolation kit without carrier RNA according to the manufacturer’s recommendations ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples are visualized on Cytoflex S, 3 lasers (488 nm, 405 nm and 638 nm) and 13 detectors (Beckman Coulter). Live cells were gated based on side scatter and forward scatter ...
-
bioRxiv - Cell Biology 2021Quote: ... The post-nuclear supernatants were ultracentrifuged using SW41Ti rotor at 100,000 g for 3 h at 4 °C on Optima L-90K (Beckman Coulter). The fraction between 0.4–0.5 M sucrose was collected ...
-
ACE2-lentiviral transduction enables mouse SARS-CoV-2 infection and mapping of receptor interactionsbioRxiv - Microbiology 2021Quote: ... UV-inactive SARS-CoV-2 was then partially-purified using a 20% sucrose cushion centrifuged at 175,000 x g for 3-4 hr using SW32Ti rotor (Beckman Coulter). The sample that has passed through the sucrose was collected and concentrated using Amicon Ultra-15 Centrifugal Filter Units with 100 kDa cutoff (Merck Millipore) ...
-
bioRxiv - Molecular Biology 2020Quote: ... and the cleared supernatant was loaded on a 3 to 30% iodixanol gradient (OptiPrep) and ultracentrifuged for 5h at 36,000 rpm in an SW60 rotor (Beckman Coulter). Fractions were collected manually through aspiration and RNA or proteins were isolated for further analysis.
-
bioRxiv - Microbiology 2020Quote: ... The filtered supernatant was then spun through a 20% sucrose cushion at 48,000 rpm for 3 hours in a SW55Ti rotor (Beckman Coulter). The SVP pellets were resuspended in a 4X non-reducing buffer (Alfa Aesar ...
-
bioRxiv - Cell Biology 2021Quote: ... The samples were centrifuged at 4°C for 3 h at 100,000 g by using Avanti J-30XP (Beckman, USA), and the fractions were collected using a Brandel Fractionation System (USA ...
-
bioRxiv - Microbiology 2021Quote: ... 60% w/v) and centrifuged at 64,000 x g for 3 hours in A27-8×50 mL rotor (Beckman Coulter). The visible virus bands were collected ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The gradients were ultra-centrifuged at 41,000 rpm for 3 hours at 4°C (Optima L-80 XP ultracentrifuge (Beckman-Coulter)) ...