Labshake search
Citations for Beckman :
151 - 200 of 515 citations for RPA kit reagent since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2022Quote: ... Dynabeads MyOne SILANE (10x Genomics) and the SPRIselect Reagent (Beckman Coulter, Indianapolis, IN, USA) were used to purify resulting cDNA ...
-
bioRxiv - Microbiology 2019Quote: ... PCR products were purified using Agencourt AMPure XP reagent (Beckman Coulter, Brea, California, USA). Sequences from other known GHVs were aligned at the 3.4 kb region spanning from gB to DNApol gene ...
-
bioRxiv - Genomics 2021Quote: ... DNA was eluted into nuclease-free water and purified with SPRIselect reagent (Beckman Coulter). All libraries were sequenced in one sequencing run on NextSeq 500 high-output (Illumina ...
-
bioRxiv - Molecular Biology 2022Quote: Primers were removed after the second PCR step with AMPure XP Reagent (Beckman #A63882). Library was quantified (QuantiFluor® dsDNA System ...
-
bioRxiv - Cell Biology 2023Quote: ... Size selective purification is performed at 0.6x volume of SPRIselect reagent (Beckman Coulter, B23317) to the transferred PCR product (27 μL SPRIselect to 45 μL of the PCR product ...
-
bioRxiv - Molecular Biology 2022Quote: ... Reverse transcription reactions were cleaned up using AMPure XP Reagent magnetic beads (Beckman Coulter). For EBs RT-qPCR ...
-
bioRxiv - Genomics 2023Quote: ... Aliquots of the PCR products were purified for sequencing using SPRIselect Reagent (Beckman Coulter) in two double-sided 0.45X-0.8X reactions and two 0.8X reactions ...
-
bioRxiv - Cancer Biology 2023Quote: KMS11 or JJN3 cells were fixed and permeabilized using IntraPrep Permeabilizaton Reagent (Beckman Coulter) following the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2023Quote: The cells were fixed and permeabilized using the IntraPrep Permeabilization Reagent (Beckman Coulter A07803) according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2024Quote: ... Post cDNA amplification and cleanup was performed using SPRI select reagent (Beckman Coulter B23318). Post cDNA amplification and post-library construction quality control was performed using the Agilent Bioanalyzer High Sensitivity kit (Agilent 5067–4626) ...
-
bioRxiv - Genomics 2024Quote: ... PCR products were purified and concentrated using AMPure XP SPRI Reagent (#A63881, Beckman Coulter) and subsequently by agarose gel electrophoresis to isolate 260 bp amplicons.
-
bioRxiv - Developmental Biology 2024Quote: ... Another purification step based on construct size was performed with SPRIselect reagent (Beckman Coulter) prior to quantification and quality control with a Bioanalyzer High Sensitivity chip (2100 Bioanalyzer ...
-
bioRxiv - Genetics 2024Quote: ... Amplified products (1 µg) were purified using AMPure XP bead-based reagent (Beckman Coulter) with 0.95X ...
-
bioRxiv - Developmental Biology 2020Quote: ... enzymatic fragmentation and size selection were performed using SPRI select reagent (Beckman Coulter, Cat# B23317) to optimize the cDNA size ...
-
bioRxiv - Genomics 2020Quote: ... the amplified full-length cDNA library was purified with 2X SPRIselect Reagent (B23318, Beckman Coulter) and eluted in 40 μL of nuclease-free water ...
-
bioRxiv - Bioengineering 2022Quote: ... The cDNA was then purified using AMPure XP reagent (Beckman Coulter IN, USA, Cat#A63881) and the recommended protocol ...
-
bioRxiv - Neuroscience 2021Quote: ... we amplified cDNAs by PCR and purified them with SPRIselect reagent (Beckman Coulter, Cat# B23318). We analyzed the cDNA quantification and quality using Agilent Bioanalyzer 2100 ...
-
bioRxiv - Bioengineering 2020Quote: ... Post sample index PCR double sided size selection done using the SPRIselect Reagent (Beckman Coulter). Post library construction quantification was done using a High Sensitivity D1000 ScreenTape Assay (Agilent ...
-
bioRxiv - Immunology 2021Quote: ... enzymatic fragmentation and size selection were performed using SPRI select reagent (Beckman Coulter, Cat# B23317) to optimize the cDNA size ...
-
bioRxiv - Developmental Biology 2020Quote: ... Post cDNA amplification and cleanup was performed using SPRI select reagent (Beckman Coulter, Cat# B23318). Post cDNA amplification and post library construction quality control was performed using the Agilent Bioanalyzer High Sensitivity kit (Agilent 5067-4626) ...
-
bioRxiv - Cancer Biology 2023Quote: The barcoded-cDNA was purified twice with 0.8X AMPure XP reagent (BeckMan Coulter, cat.co. A63881) as per manufacturer’s instructions ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... according to the manufacturer instructions and products cleaned using AMpure XP reagent (Beckman Coulter, A63881). Libraries prepared from different samples were combined in equimolar ratios as suggested by the Illumina manual and used in paired-end next generation sequencing (NGS ...
-
bioRxiv - Developmental Biology 2023Quote: ... Five PCR cycles were run and PCR products were purified using AMPure XP reagent (Beckman Coulter Life Sciences ...
-
bioRxiv - Cell Biology 2023Quote: ... The cDNA was amplified and then cleaned using SPRISelect reagent beads (cat# B23318, Beckman Coulter). The cDNA was quality checked using a High Sensitivity D5000 ScreenTape (cat# 5067-5592 ...
-
bioRxiv - Cell Biology 2024Quote: ... 6-8 PCR reactions were pooled and purified with AMPure XP SPRI Reagent (Beckman Coulter), first at 0.6x and then at a 1x volumetric ratio ...
-
bioRxiv - Cell Biology 2023Quote: ... removing unincorporated sequencing reagents is performed using CleanSeq magnetic beads (Agencourt, Beckman Coulter, Brea, CA). Two control samples were included with every sequencing to ensure the proper performance of reagents and equipment.
-
bioRxiv - Cell Biology 2024Quote: ... PCR1 and PCR2 products were purified using AMPure XP Bead-Based Reagent (Beckman Coulter, A63881) according to manufacturer’s instructions.
-
bioRxiv - Genomics 2020Quote: ... 50 ng genomic DNA was purified using AgencourtAMPure XP Reagent (Beckman Coulter Inc, Brea, CA, USA) according to manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2020Quote: DNA preparation: 200 ng genomic DNA was purified using Agencourt AMPure XP Reagent (Beckman Coulter, Inc.) according to the manufacturer’s protocol ...
-
bioRxiv - Bioengineering 2021Quote: ... Red blood cells present in the sample were lysed using the IMMUNOPREP Reagent System (Beckman Coulter) and red blood cell debris was washed away using the Lyse Wash Assistant (BD Biosciences) ...
-
bioRxiv - Cancer Biology 2021Quote: ... Each 16S rRNA gene amplicon was purified using the AMPure XP reagent (Beckman Coulter, Indianapolis, IN). In the next step each sample was amplified using a limited cycle PCR program ...
-
bioRxiv - Cell Biology 2021Quote: ... Amplified cDNA was cleaned with 0.6X SPRISelect reagent (catalog number B23318, Beckman Coulter, Pasadena, CA, USA). Cleaned cDNA was then quality checked on an Agilent Tapestation 4150 (catalog number G2992AA ...
-
bioRxiv - Immunology 2022Quote: ... and titered for infectivity in CEM.NKRCCR5 cells (NIH AIDS Reagent Program) by p24 staining (Beckman-Coulter). ADCC activity was measured as previously described [39] ...
-
bioRxiv - Developmental Biology 2023Quote: ... Amplicons were ligated to barcode adapters and purified using Agencourt AMPure XP reagent (Beckman Coulter Inc.). After purification ...
-
bioRxiv - Genomics 2020Quote: ... and cleaned with 0.7X AMPure beads to remove small fragments and excess reagents (Beckman Coulter, Brea, CA). The genomic DNA libraries were then captured following the SeqCap protocol which was modified to increase final capture reaction volume by 1.5X (Roche ...
-
bioRxiv - Microbiology 2021Quote: ... genomic DNA was prepared from the D1 and D10 bacterial pellets using GenFind v3 reagents (Beckman Coulter). A long-read sequencing library was prepared using the ligation library kit (LSK-109 ...
-
bioRxiv - Bioengineering 2020Quote: ... end repair and A-tailing double-sided size selection was done using the SPRIselect Reagent (Beckman Coulter). Adaptor ligation was done at 20 °C for 15 min ...
-
bioRxiv - Genetics 2020Quote: ... For SPRI beads cleanup and no size selection we used AMPure XP Reagent (Beckman Coulter, cat. A63881). 0.8 x volume of beads were added to PCR reactions ...
-
bioRxiv - Immunology 2022Quote: Lymphocyte subsets were analyzed using cyto-Stat tetra CHROME (CD3/ CD4/CD8/CD45) reagent (Beckman Coulter, Switzerland). The analysis was performed according to the product manual ...
-
Plastid double-strand RNA transgenes trigger small RNA-based gene silencing of nuclear-encoded genesbioRxiv - Plant Biology 2022Quote: ... We size-selected sRNA libraries for the end product of ~150-nt using the SPRIselect Reagent (Beckman Coulter Life Sciences ...
-
bioRxiv - Plant Biology 2023Quote: ... The entire reaction volume was purified using 0.5 volumes of AMPure XP SPRI Reagent (Beckman Coulter, A63881) according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2023Quote: ... The resulting PCR amplicons were cleaned-up with AMPure XP bead-based reagents (Beckman Coulter Life Science), DNA concentration and fragment distribution quantified on a fragment analyser (Agilent ...
-
bioRxiv - Microbiology 2024Quote: ... the barcoded amplicons were cleaned up in multiple steps using the AMPure XP reagent (Beckman Coulter, A63881) in combination with the DynaMagTM-2 magnetic tube stand (Thermo Fisher Scientific ...
-
bioRxiv - Immunology 2024Quote: ... After wash step cells were fixed and permeabilized using IntraPrep Permeabilization Reagent (Beckman Coulter, Brea, CA, USA). Subsequently ...
-
bioRxiv - Genomics 2020Quote: ... Ligated and nick repaired DNA was purified with Agencourt AMPure® XP Reagent (1.4x sample volume) (Beckman Coulter) assuming a targeted 200 base-read library ...
-
bioRxiv - Bioengineering 2021Quote: ... The cDNA was then subjected to 8-14 cycles of amplification before clean-up using SPRIselect Reagent (Beckman). Total cDNA yield was calculated following quality assessment (High Sensitivity D5000 ScreenTape ...
-
bioRxiv - Genomics 2019Quote: ... We added Illumina TruSeq adaptors using NEBNext DNA Library Prep reagents and Ampure XP beads (Beckman Coulter: A63881). We prepared WT libraries using the NEBNext DNA Library Prep Master Mix Set for Illumina (New England Biolabs ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... although we substituted Sera-mag Speed Beads (Rohland and Reich 2012) for AMPure reagents (Beckman-Coulter, Brea, CA).
-
bioRxiv - Molecular Biology 2023Quote: ... The first five were measured using a Beckman DxC 600 clinical analyzer with reagents from Beckman (Brea, CA) and Fujifilm Wako (Osaka ...
-
bioRxiv - Genetics 2023