Labshake search
Citations for Beckman :
101 - 150 of 1814 citations for SARS CoV 2 Spike Glycoprotein S1 His tag Insect Cells since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genetics 2019Quote: ... Cell aliquots were used to determine cell number and viability by automated cell counting (Vi-Cell, Beckman Coulter, Indianapolis, IN, USA). Cells were diluted to a concentration of 200,000 total cells/mL with external solution (see below for composition ...
-
bioRxiv - Immunology 2019Quote: ... cells were isolated from CD4+ T cells via fluorescence activated cell sorting (FACS) using a MoFlo XDP cell sorter (Beckman Coulter) (Supplementary Figure 5 ...
-
bioRxiv - Cancer Biology 2021Quote: ... cell numbers were counted using the Vi-Cell automated cell counter (Beckman Coulter, Cat # 731196).
-
bioRxiv - Biochemistry 2020Quote: ... and cell size were measured using a cell counter (Vi-cell Beckman Coulter, Fullerton, CA). Glucose ...
-
bioRxiv - Cancer Biology 2022Quote: ... Total nucleated cells were quantified by Vi-Cell XR cell counter (Beckman Coulter, Brea, CA) and used for downstream data production.
-
bioRxiv - Cancer Biology 2022Quote: ... Viable cells were counted by Vi-Cell XR Cell Viability Analyzer (Beckman Coulter, Brea, CA) and then diluted accordingly to reach the targeted cell concentration.
-
bioRxiv - Immunology 2020Quote: ... Total viable cells were determined using the Vi-Cell XR Cell Viability Analyzer (Beckman Coulter).
-
bioRxiv - Cancer Biology 2024Quote: ... cells were counted on day 0 using a Vi-Cell XR Cell Counter (Beckman Coulter) and plated in a tissue culture-treated 6-well plates at 20,000 cells/mL in 2 mL of complete media containing XHC-640 (100 nM) ...
-
bioRxiv - Cell Biology 2023Quote: ... and the cells were counted using an i-cell XR cell viability analyzer (Beckman Coulter).
-
bioRxiv - Cancer Biology 2024Quote: ... The viable cell count was done in the Vi-Cell cell viability Analyzer (Beckman Coulter).
-
bioRxiv - Biochemistry 2019Quote: ... followed by spinning at 158,000 g for 2 hours (Ti45 rotor, Beckman Coulter). The lysate was passed through a column containing 2 mL TALON superflow at 0.5 mL/min ...
-
bioRxiv - Microbiology 2020Quote: ... Centrifugation was performed at 120,000 × g for 2 hr (Beckman TLS 55 rotor), after which the interface between 0.25 M and 1.1 M sucrose was collected and resuspended in 1 ml 19% OptiPrep for a step gradient containing 0.5 ml 22.5% ...
-
bioRxiv - Cell Biology 2022Quote: ... 2× – G2) was interrogated using a using a Gallios flow cytometer (Beckman Coulter) and subsequent data analysis with FlowJo (v.10.8.0) ...
-
bioRxiv - Genomics 2019Quote: ... Tagmented DNA was purified using 2× SPRI beads (Agencourt AMPure XP-Beckman Coulter). Finally ...
-
bioRxiv - Synthetic Biology 2021Quote: PCR products were purified with 2 volumes of RNAClean XP beads (Beckman Coulter) and then quality-checked and quantified on a Bioanalyzer (Agilent) ...
-
bioRxiv - Biophysics 2022Quote: ... 2 mM DTT) with 0.7 M sucrose in Ti-45 tubes (Beckman-Coulter). The tubes were then placed in a Ti-45 rotor and spun at 27,000 rpm (57,000 xg ...
-
bioRxiv - Biophysics 2022Quote: ... 2 M urea) by resuspension and centrifugation on a JS-4.2 rotor (Beckman) at 6,000 RPM for 30 minutes ...
-
bioRxiv - Genetics 2024Quote: ... DNA was further purified using 2 volumes of Ampure XP beads (Beckman Coulter). DNA was extracted from 10000 undifferentiated or differentiated spermatogonia cell samples by QIAamp DNA Micro Kit (Qiagen # 56304 ...
-
bioRxiv - Molecular Biology 2023Quote: ... The ribodepleted RNA was cleaned using 2× RNAClean XP beads (Beckman Coulter A63987), eluting with 20 μL DNase digestion reaction mixture (1.5 μL Turbo DNase (Invitrogen AM2238) ...
-
bioRxiv - Neuroscience 2023Quote: ... for 2 h using 25 ξ 89 mm polycarbonate tubes (Beckman Coulter, 355618). Pellets were resuspended in 500 μL of sterile phosphate-buffered saline (PBS ...
-
bioRxiv - Neuroscience 2023Quote: ... for 2 h using 16 ξ 76 mm polycarbonate tubes (Beckman Coulter, 355603). The resulting pellets were resuspended in 250 μL of sterile PBS ...
-
bioRxiv - Immunology 2024Quote: ... and 2 mM DTT) and separated by ultracentrifugation at 148,900xg (Ti55 rotor, Beckman) for 1.5 hours at 4°C ...
-
bioRxiv - Cell Biology 2021Quote: ... counted using a Vi-Cell cell counter (Beckman Coulter) and centrifuged for 5 min at 300 × g ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were counted on Vi-Cell XR (Beckman Coulter) and spun at 300g for 3 min at RT ...
-
bioRxiv - Neuroscience 2024Quote: ... Cell viability as measured by Vi-Cell (Beckman Coulter) for all samples was above 90% ...
-
bioRxiv - Immunology 2019Quote: ... and subjected to cell quality control using Vi-CELL XR cell counter (Beckman Coulter, Brea, CA). All of the processed B cells had cell viability >90% ...
-
bioRxiv - Synthetic Biology 2022Quote: ... Cell viability and density were monitored with a Vi-CELL automated cell viability analyzer (Beckman-Coulter).
-
bioRxiv - Bioengineering 2022Quote: ... and the cell number was estimated using a Vi-CELL XR Cell Viability Analyzer (Beckman Coulter). For the FCM experiments ...
-
bioRxiv - Cancer Biology 2021Quote: The SCLC and AML cells were counted using a Vi-Cell XR Cell Counter (Beckman Coulter) and resuspended in 1 mL lentivirus with 8 μg/mL polybrene at the following concentrations in individual wells of a 12 well plate ...
-
bioRxiv - Cancer Biology 2022Quote: ... Quantitation of viable cells was performed using an Automated Cell Viability Analyzer (Beckman Coulter Vi-Cell). All cell lines were stored in ampoules in liquid nitrogen after receipt ...
-
bioRxiv - Cancer Biology 2022Quote: ... GFP positive cells were single cell sorted with the MoFlo cell sorter (Beckman Coulter, Brea, USA). Clonal cultures were evaluated for A549-Src KO by western blot and a representative clone was selected.
-
bioRxiv - Immunology 2021Quote: ... Cells were counted using a Beckman Vi-CELL XR Cell Viability Analyzer (Beckman Coulter, Brea, CA), and 3×106 cells per tissue per mouse were added to individual FACS tubes or wells of a 96-well non tissue culture treated round bottom plate.
-
bioRxiv - Immunology 2020Quote: ... PBMCs were assessed for viability and cell count using Vi-Cell automated cell counter (Beckman-Coulter). PBMCs were adjusted to 10×106 cells/ml in cryopreservation media (90% FBS ...
-
bioRxiv - Immunology 2021Quote: ... cells were stained with trypan blue and counted with a Vi-CELL cell counter (Beckman Coulter).
-
bioRxiv - Cell Biology 2024Quote: ... GFP positive cells were isolated by fluorescence-activated cell sorting (Beckman Coulter Moflo Astrios cell sorter) for following use.
-
bioRxiv - Cancer Biology 2022Quote: ... Cell number on day 1 was measured using a Vi-CELL XR Cell Viability Analyzer (Beckman Coulter). 24h later (day 2) ...
-
bioRxiv - Immunology 2019Quote: ... Cell viability was measured before flow cytometry using the Vi-Cell XR Cell Viability Analyzer (Beckman Coulter) and tracked during flow cytometry using the LIVE/DEAD Fixable Blue Dead Cell Stain Kit for UV Excitation (ThermoFisher Scientific) ...
-
bioRxiv - Genomics 2020Quote: ... PBMCs were assessed for viability and cell count using a Vi-Cell automated cell counter (Beckman-Coulter). PBMCs were adjusted to 10×106 cells/ml in cryopreservation media (90% FBS ...
-
bioRxiv - Biophysics 2022Quote: ... cells were sorted in an Astrios Cell Sorter (Beckman Coulter), defining the “off” population with a combination of gates on FITC height and width ...
-
bioRxiv - Bioengineering 2020Quote: ... An automated cell counter (Beckman Coulter, Vi-Cell viability analyzer) was used for counting the number of cells ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Cells were counted using a Vi-CELL (Beckman Coulter, #383556) then diluted with McCoy’s media to achieve a count of 1,250 cells per well using a dispense volume of 40 μL per well ...
-
bioRxiv - Neuroscience 2019Quote: ... Fluorescently-activated cell sorting (MoFlo XDP cell sorter; Beckman Coulter) was then performed using the Col1a1-GFP+/GFP marker to isolate GFP+ fibroblasts from other cell types ...
-
bioRxiv - Cancer Biology 2022Quote: ... Viable cell count was obtained (Beckman Coulter, Vi-cell Analyzer) and cells were gently re-suspended in 4 mls of assay buffer ...
-
bioRxiv - Cancer Biology 2022Quote: ... Viable cell count was obtained (Beckman Coulter, Vi-cell Analyzer) and 5×103 viable GSCs were added to each well containing BSA-DMEM Ham’s F12 50/50 medium followed by incubation at 37°C and 5% CO2 for 2 hours ...
-
bioRxiv - Genomics 2023Quote: ... Cells were counted with the Vi-Cell XR Analyzer (Beckman) and diluted to 0.8 cells per 100 μL ...
-
bioRxiv - Cell Biology 2023Quote: ... cells were analyzed on a cell analyzer (Cytoflex, Beckman Coulter) equipped with 488 nm ...
-
bioRxiv - Cancer Biology 2021Quote: ... decrosslinked material was purified with 2 x AMPure XP beads (Beckman Coulter, Cat #A63881) and eluted in 30 μL of 10 mM Tris-Cl ...
-
bioRxiv - Neuroscience 2020Quote: ... DRG were then centrifuged for 2 min at 1000 rpm (Beckman Allegra X15R, 233xg), supernatant aspirated ...
-
bioRxiv - Molecular Biology 2020Quote: ... and centrifuged for 2 hours at 55,000 rpm (TLS-55 rotor, Beckman Coulter, USA). 11x 200 μl fractions were harvested and subjected to FLAG-IP ...
-
bioRxiv - Genomics 2019Quote: ... The reaction was next cleared by 2× AmpureXP beads (Agencourt AMPure XP, Beckman Coulter) and eluted in 75 μl EB (10 mM Tris-HCl pH 8) ...