Labshake search
Citations for Beckman :
1251 - 1300 of 1540 citations for 5 Pyrimidinecarbonitrile 4 6 diamino 2 methoxy 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... The supernatant was again centrifuged at 100000 g for 45 min at 4°C (Beckman Optima™ MAX-XP Rotor MLS-50). After filtering the supernatant through a 0.22 μm syringe filter ...
-
bioRxiv - Cell Biology 2022Quote: ... One milliliter of concentrated conditioned medium was pipetted on top of the gradient and samples were centrifuged for 18 h at 100,000 ×g and 4 °C using a SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Fractions of 1 mL were collected from the top and EV-rich fractions 9 and 10 (corresponding to a density of 1.10-1.12 g/mL ...
-
bioRxiv - Biochemistry 2023Quote: ... Cultures were then recovered by centrifugation (4,000 x g, 4 °C, 40 min in a Beckman Avanti JXN-26 (rotor: JLA 8.1)) and pellets resuspended in approximatively 30 mL of lysis buffer (20 mM HEPES ...
-
bioRxiv - Molecular Biology 2024Quote: ... ADEV isolation was performed by ultracentrifugation at 100,000 × g for 14 h at 4 °C (swing bucket rotor on minimum acceleration/break setting, SW 32Ti Beckman Coulter, Brea, CA), and ADEVs were resuspended in 200μL PBS and stored at −20°C until used16,41 ...
-
bioRxiv - Cell Biology 2024Quote: ... All centrifugation steps were done at 4°C and the last two steps were performed using Optima XE-90 ultracentrifuge (Beckman Coulter, A94471) with rotor SW32Ti (Beckman Coulter ...
-
bioRxiv - Microbiology 2024Quote: ... Saliva was collected by expectoration into tubes on ice followed by centrifugation for 10 minutes at 4°C at 4000 x g (Beckman SX4750 rotor) to remove large debris and bacterial aggregates ...
-
bioRxiv - Cell Biology 2024Quote: ... The collected monosomes were then 1:1 diluted with PEB and centrifuged at 60,000 rpm at 4°C overnight on an SW65 Ti ultracentrifuge rotor (Beckman Coulter, California, USA). The pellets were resuspended in 250µl PEB with 50 mM NH4Cl ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was clarified by centrifugation at 5500 rpm for 20 min at 4°C (AllegraTM 21R Centrifuge, Beckman Coulter, CA, USA). The sample was then loaded into a HisTrap HP 5 mL column (Cytiva ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were incubated further overnight at 20°C and subsequently harvested by centrifugation (Beckman rotor 8.1000, 5000 rpm, 15 min, 4°C). The pellet was resuspended in PBS ...
-
bioRxiv - Neuroscience 2023Quote: ... then spun at 100,000 x g for 30 min at 4°C in an ultracentrifuge (Beckman OPTIMA TLX with TLA-100.3 rotor). The supernatant was saved and the pellet went through a series of similar extractions using High-Salt Triton Buffer (High-Salt Buffer ...
-
bioRxiv - Neuroscience 2023Quote: ... The supernatants were then combined and centrifuged at 17,000g for 10min at 4°C in a Beckman SW41-Ti rotor (Beckman Coulter, Brea, CA). The supernatant was saved as the cytosolic (CYT ...
-
bioRxiv - Cell Biology 2023Quote: Myf5High and Myf5Low MuSCs were isolated from a pool of 4 male and 4 female mice and repeated in two independent experiments and total RNA was extracted using Agencourt RNAdvance tissue Kit (Beckman Coulter, #A32646) with a quality score of RQN 9.3 to 10 ...
-
bioRxiv - Cell Biology 2023Quote: ... was next subjected to ultracentrifugation at 120,000 × g for 4 h in a SW 28 Ti Swinging-Bucket Rotor (Beckman Coulter, Fullerton, CA) to sediment small EVs ...
-
bioRxiv - Biochemistry 2023Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Biochemistry 2023Quote: ... by centrifugation at 80,000 × g for 30 min at 4°C using a TLS-55 rotor (Beckman Coulter Inc., Miami, FL, USA). Crista membranes were identified and removed based on fluorescence under a UV lamp ...
-
bioRxiv - Cell Biology 2023Quote: ... Following centrifugation at 131,300 × g for 24 hr at 4 °C using a MLS-50 Swinging-Bucket rotor (Beckman Coulter, Brea, CA) to sediment protein complexes ...
-
bioRxiv - Biophysics 2024Quote: ... Samples were centrifuged at 24,000 rotations per minute using an S-28 rotor at 4◦C in an Optima XL-100K Ultracentrifuge (Beckman Coulter, Brea, CA). The supernatant was decanted ...
-
bioRxiv - Developmental Biology 2024Quote: ... for 30 min at 4°C in the dark followed by flow cytometry analysis on a CytoFlex 26 (Beckman Coulter, Indianapolis, IN) in PE-A and PerCP-A channels ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Molecular Biology 2024Quote: ... was loaded on top of the gradient and spun at 4°C for 18 hr at 30,000 rpm (Beckman, Rotor SW-41Ti). Samples were fractionated with absorbance optics (λ = 260 nm ...
-
bioRxiv - Biophysics 2020Quote: ... lysate was centrifuged at 5 °C with 13000 rpm for 15 min by Avanti J-E Ultra Centrifuge (Beckman Coulter). Supernatant from centrifugation was filtered with 0.45 μm SFCA syringe filters (Sigma Aldrich ...
-
bioRxiv - Microbiology 2020Quote: ... and overlaid with 6 ml of 30% and 3 ml of 5% sucrose (w/v) followed by centrifugation at 32,000 rpm in SW41 rotor (Beckman Coulter) for 20 h ...
-
bioRxiv - Molecular Biology 2020Quote: ... Four mL of each density (3.5 mL for the 5% density) was stacked into an open polyallomer tube (337986, Beckman Coulter) using a Tecan freedom EVO ...
-
bioRxiv - Biophysics 2022Quote: ... The cell suspension was centrifuged for 5 min at 2000 g (Centrifuge Beckman Coulter Allegra X-15-R, Rotor Sx4750A)) and 4°C ...
-
bioRxiv - Cell Biology 2020Quote: ... 5 × 105 additional cells were immediately processed for far red signal analysis by flow cytometry (Gallios, Beckman Coulter, Brea, USA) (D0) ...
-
bioRxiv - Genomics 2019Quote: ... DNA samples were loaded onto 5-20% sucrose gradients and fractionated according to size by centrifugation (SW-40Ti rotor; Beckman Coulter Optima L-100 XP ...
-
bioRxiv - Microbiology 2019Quote: ... Then 0.8 mL of Cold 60% sucrose buffer A was added to RNAse-free 5 mL Ultraclean tubes for ultracentrifugation in a SW55Ti (Beckman). The ribosome-containing supernatant was used to fill these tubes and an ultracentrifugation step was performed for 16 hs at 150.000g ...
-
bioRxiv - Neuroscience 2020Quote: ... reverse 5’-CTTA TTAGTCAGTCAGAAACAAC-3’).ThePCR amplicon was purified using RNAse-free SPRI beads (Agencourt RNAclean XP, Beckman-Coulter A63987) and then used for in vitro transcription with the HiScribe T7 ARCA mRNA Kit (with tailing ...
-
bioRxiv - Microbiology 2020Quote: ... the 96-well plate was centrifuged at 1,000 RPM for 5 min using an Allegra 25R model centrifuge (Beckman Coulter) with inserts for 96-well plates ...
-
bioRxiv - Microbiology 2020Quote: ... At the end of each selection cells were pelleted from the media by centrifugation 200 x g for 5 min in an Allegra centrifuge (Beckman) and supernatant was transferred for storage at −80C ...
-
bioRxiv - Microbiology 2022Quote: ... and layered onto a preformed 11 mL 5% to 15% (wt/vol) Ficoll gradient in a 13.2 mL thin-wall polyallomer ultracentrifuge tube (Beckman Coulter). Gradients were centrifuged at 12,000 rpm for 2 h at 4°C in an SW41 Ti swinging-bucket rotor in a Sorvall Discovery SE ultracentrifuge ...
-
bioRxiv - Immunology 2022Quote: ... 1.5 μl of PI was also added and samples were run on the Gallios™ Flow Cytometer (Beckman Coulter, Inc). Data was analysed offline using Kaluza® Flow Analysis software version 2.1a (Beckman Coulter Inc. ...
-
bioRxiv - Immunology 2021Quote: ... subsequently overlaid onto 5 mL of 20% sucrose and ultracentrifuged at 24,000 rpm for 2.5 hrs (Beckman XPN80, SW32.Ti). The viral pellet was resuspended in PBS.
-
bioRxiv - Physiology 2019Quote: ... Agencourt AMPure XP PCR purification kit (5 ml Beckman Coulter Part No. A63880; 60 ml Beckman Coulter Part No. A63881) was used ...
-
Proteome of the secondary plastid of Euglena gracilis reveals metabolic quirks and colourful historybioRxiv - Evolutionary Biology 2019Quote: ... The DNase-treated lysate (5 ml) was loaded on top of a sucrose discontinuous density gradient in ultracentrifuge tubes (Cat. No. 344058, Beckman). The gradient was prepared by layering decreasingly dense sucrose solutions upon one another from 2.0 ...
-
bioRxiv - Microbiology 2021Quote: ... bacterial cells were washed in PBS and diluted 1:5 before acquisition on a CytoFLEX benchtop flow cytometer (Beckman Coulter). For each sample ...
-
bioRxiv - Molecular Biology 2022Quote: ... Concentrated chromatin samples were loaded on 11 mL gradients of 5-25% sucrose in TE buffer and centrifuged in a preparative ultracentrifuge with a SW41 Ti rotor (Beckman) for 11 hrs ...
-
bioRxiv - Cell Biology 2022Quote: ... Cells were centrifuged at 1500 g for 5 min in an F2402 rotor in a GS15R table-top centrifuge (Beckman) and resuspend with water to wash the cells ...
-
bioRxiv - Cancer Biology 2024Quote: ... The fragments were repaired the 3’and 5’overhangs using End repair mix (component of SureselectXT) and purified using Agencourt AMPure XP Beads (Beckman). The purified fragments were added with ‘A’ tail using A tailing Mix (component of SureSelectXT ...
-
bioRxiv - Microbiology 2023Quote: ... Sample analysis was performed by mixing 5 µl of fluorescent vesicles with 20 µl of Flow-Count Fluorospheres (Beckman Coulter) in a final volume of 200 µl of PBS to determine absolute counts ...
-
bioRxiv - Genetics 2023Quote: ... Libraries were amplified using 5-7 cycles of PCR using KAPA HiFi DNA polymerase and purified with 1.1X SPRI (Beckman Coulter). Nucleosome profiles were manually inspected using a Tapestation with the D1000 Screen Tape system (Agilent) ...
-
bioRxiv - Biophysics 2023Quote: ... Each 300μl dialysate was mixed with 300μl of 80% (w/v) Nycodenz dissolved in reconstitution buffer and then divided equally into two 5 x 41 mm ultracentrifuge tubes (Beckman). Then ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysates were then loaded onto a 5-50% sucrose density gradient and centrifuged in an SW41 Ti rotor (Beckman) at 36,000 rpm for 2 h at 4 °C ...
-
bioRxiv - Molecular Biology 2023Quote: ... Lysed cells were centrifuged and the viscous supernatant was immediately loaded on a 5-24% (w/v) sucrose density gradient and centrifuged in SW 32 Ti rotor (Beckman) overnight ...
-
bioRxiv - Microbiology 2023Quote: Human bladder cell line PD07i was cultured at 37°C with 5% CO2 to confluency as previously described and counted using a Coulter Counter (Beckman) to a minimum of 1×105 cells/mL ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysates were sheared with a 25-gauge 5/8 needle and loaded onto CsCl solution (150% w/v) for ultracentrifugation in NVT 65.2 rotor (Beckman coulter) at 42,000 rpm for 20 hours at 4°C ...
-
bioRxiv - Genetics 2021Quote: ... and samples were evaluated 2 minutes later with a Cytomics FC500 flow cytometer (Beckman Coulter, Brea, CA, USA) AO was excited with a 488 nm argon laser ...
-
bioRxiv - Genomics 2020Quote: ... The PCR products were purified by using 1.3X Agencourt AMPure XP beads (2 or 3 cycles; Beckman Coulter) and evaluated by using an Agilent High Sensitivity DNA Kit on an Agilent 2100 Bioanalyzer (Agilent) ...
-
bioRxiv - Cancer Biology 2020Quote: ... concentrated for 2 h by ultracentrifugation in a swing-out rotor SW-32Ti (Beckman Coulter, Brea, US-CA) at 26000 g ...