Labshake search
Citations for Beckman :
1251 - 1300 of 1463 citations for 3RS 4 Dimethylamino 3 methyl 2 2 diphenylbutanenitrile Isodidiavalo since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2020Quote: ... The resultant supernatant was collected and underwent ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor MLA-55) in 10.4 ml 16×76 mm polycarbonate capped centrifuge tubes (Beckman Coulter 355603), the pellet was washed once in PBS−/− and centrifuged again at 100,000xg for 40 minutes at 4°C ...
-
bioRxiv - Cell Biology 2020Quote: ... Reconstituted nucleosome samples were overlaid onto the sucrose gradient and spun at 32000 rpm for 20 h at 4 ° using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80 ...
-
bioRxiv - Molecular Biology 2020Quote: ... the lysate was incubated under rotation for 30 min at 4 °C and cleared for 10 min in an MLA-80 rotor (Beckman Coulter) at 11,500 xg and 4 °C ...
-
bioRxiv - Molecular Biology 2021Quote: ... Indexing PCR amplicons were pooled (4◻μl of each) and purified using AMPure XP beads (Beckman Coulter, California, United States) according to manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2020Quote: ... cells were centrifuged at 4 ℃ for 5 minutes at 300g and suspended in HBSS and analyzed with a flow cytometer (CytoFLEX, Beckman Coulter). Mean fluorescence intensity was calculated for each group.
-
bioRxiv - Systems Biology 2020Quote: ... the 500xg supernatant was first spun at 10,000xg for 10 minutes at 4°C (Beckman Coulter, fixed angle rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778) ...
-
bioRxiv - Systems Biology 2020Quote: ... each resultant fraction underwent separate ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778). In EV-enriched pooled fraction experiments ...
-
bioRxiv - Systems Biology 2020Quote: ... and underwent ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor MLA-55; Beckman Coulter 355603 10.4 ml capped tubes). Supernatant was discarded from each fraction ...
-
bioRxiv - Cell Biology 2020Quote: ... 50 µl of alkaline carbonate treated mitochondria were set aside as input (kept on ice) and 50 µl were centrifuged at 100 000g for 30 min at 4°C in TLA100 rotor (Beckman Coulter). Pellet was gently washed with ice-cold sodium carbonate buffer and resuspended in 20 µl of 1x Laemmli loading buffer ...
-
bioRxiv - Microbiology 2020Quote: ... Vesicles were obtained by centrifugation at 38,400 x g for 1 h at 4°C in an Avanti J-20XP centrifuge (Beckman Coulter, Inc). Pelleted vesicles were resuspended in 20 ml of 50 mM HEPES (pH 6.8 ...
-
bioRxiv - Microbiology 2020Quote: ... cells were fixed with 4% FA in PBS for 90 min at room temperature and immunostained for intracellular HIV-1 CA for 30 min at 4°C using KC57-FITC antibody (Beckman Coulter) diluted in 0.1% Triton X-100 ...
-
bioRxiv - Immunology 2020Quote: ... during 30min and then transferred into a DuraClone IF T Helper cell tube (CD3, CD4, IL-4, IL-17A, IFNγ) (Beckman Coulter), using the IntraPrep fixation permeabilization kit (Beckman Coulter) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The samples were then separated into membrane and matrix fractions by ultracentrifugation at 100 000 g (TLA 110 rotor) for 30 min at 4°C in OptimaTM TLX table-top ultracentrifuge (Beckman-Coulter). The supernatant fraction was transferred to new tube ...
-
bioRxiv - Neuroscience 2023Quote: ... Supernatant were loaded on top of a discontinuous 0.75/1.0/2.33 M sucrose density gradient and centrifuge at 242,000 x g for 60 min at 4°C (Beckman SWTi41 swing rotor). The growth cone depleted fraction was collected between 0.75 M and 1.0 M sucrose ...
-
bioRxiv - Cell Biology 2023Quote: ... Homogenates were then transferred to a 50 ml tube and centrifuged for 10 mins at 1 000 × g at 4°C (Beckman Coulter). The resulting supernatant was then transferred to microfuge tubes for storage at -80°C as whole liver lysates or to fresh ultracentrifuge tubes for further processing.
-
bioRxiv - Physiology 2023Quote: ... was ultracentrifuged twice in sterile 10.4 mL polycarbonate bottles at 100 000 × g for 70 min at 4°C (Optima L-100 XP Ultracentrifuge, 90 Ti Fixed-Angle Titanium Rotor; Beckman Coulter). The final EV pellet was suspended in 50 µl of PBS without Ca2+ and Mg2+ (Lonza ...
-
bioRxiv - Cancer Biology 2023Quote: ... and centrifuged at 100,000 x g either for 4 hr (hollow fiber bioreactor) or overnight (2D flask culture) in a SW32 rotor (Beckman Coulter). For the preparation of the density gradient ...
-
bioRxiv - Plant Biology 2023Quote: ... The cAW was collected by spinning at 700 x g for 20 min at 4 ⁰C (JA-14 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). vAW was filtered through a single layer of Miracloth and was combined with the cAW ...
-
bioRxiv - Cell Biology 2023Quote: ... The cilia in the upper phase were sedimented by centrifugation (27,000 g, 4°C, 20 min; Beckman Coulter, Avanti JXN-26) and resuspended in Hepes-Magnesium-EGTA-Potassium (HMEK ...
-
bioRxiv - Neuroscience 2022Quote: ... The discontinuous sucrose gradient was centrifuged at 242K g for 47 min at 4 °C in a vertical rotor (VTi50 rotor, Beckman Coulter). The bulk GC fraction (GCF ...
-
bioRxiv - Microbiology 2022Quote: ... Lysates were then submitted to centrifugation at 100,000 g for 45 min at 4°C in an Ultracentrifuge Beckman XL-90 (Beckman France, Villepinte) equipped with a 70.1T1 rotor ...
-
bioRxiv - Cancer Biology 2024Quote: ... CRC cells were then cocultured at a 1:1 ratio with BMDCs for 4 hours and analyzed for uptake of CRC DNA by flow cytometry on the CytoFlex S cytometer (Beckman Coulter). Analysis was performed in FlowJo.
-
bioRxiv - Biophysics 2024Quote: ... The virions were harvested from the supernatant by centrifugation through 1.5ml of 30% sucrose at 10,000 RPM at 4°C for 2hrs (Beckman L8-70M Ultracentrifuge). The resulting pellet of virions was resuspended in 20ul of RIPA lysis buffer containing protease inhibitors.
-
bioRxiv - Molecular Biology 2024Quote: ... for ultracentrifugation at 100,000 rcf for 70 min at 4 °C using a Optima XE-90 ultracentrifuge with a SW 32 Ti rotor (Beckman Coulter). The EV pellet was resuspended in 0.22 μm-filtered sterile PBS and freshly-used or stored at −80 °C until further use ...
-
bioRxiv - Neuroscience 2024Quote: ... and centrifuged at ∼14.000 x g max (∼10900 x g average) for 22 min at 4 °C (Beckman Coulter, MAX-XP). After centrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... plasma samples were thawed on ice and subjected to ultracentrifugation at 100,000 g for 1 hr or 18 hr at 4 °C (TLA-55 rotor; Optima MAX-MP Tabletop Ultracentrifuge, Beckman Coulter). Pellets were washed once in 1.0 ml PBS ...
-
bioRxiv - Microbiology 2024Quote: ... The final Hcp1-VLPs particles were pelletized by ultracentrifugation at 274,000 ×g at 4°C for 1 h in a SW41 Ti rotor (Beckman Coulter, Inc). The final pellet was resuspended in PBS pH 7.4.
-
bioRxiv - Microbiology 2023Quote: ... The normalized cultures were then centrifuged at 5030 x g and 4°C for 20 minutes on an Avanti J-26 XPI (Beckman-Coulter) centrifuge (JS 5.3 rotor) ...
-
bioRxiv - Microbiology 2024Quote: ... Most of the supernatant was discarded leaving 12x∼200 µL of concentrated broken pieces of genomic fiber that were pooled and layered on top of ultracentrifuge tubes of 4 mL (polypropylene centrifuge tubes, Beckman Coulter) containing a discontinuous cesium chloride gradient (1.4 ...
-
bioRxiv - Neuroscience 2024Quote: ... The same mass of total extracts was taken for a high spin at 154,000 g for 20 minutes in 4 °C using an ultracentrifuge (Beckman, TLX-120K) to obtain the supernatant soluble fraction (S1 ...
-
bioRxiv - Biochemistry 2023Quote: ... Mitochondrial crude was pelleted by centrifugation at 9500 ×g (4 °C, 15 min) using the Optima XE-90 Ultracentrifuge with a Ti-45 rotor (Beckman Coulter). The final pellet was resuspended in 2 mL of Resuspension buffer (250 mM sucrose ...
-
bioRxiv - Bioengineering 2023Quote: ... The suspension was then ultracentrifuged (58,000 × g, 1 hr., 4 °C) in an Optima MAX-XP (Beckman Coulter, Indianapolis, IN, USA) to separate residual catalyst ...
-
bioRxiv - Biochemistry 2023Quote: ... then centrifuged at 27,000 gmax for 15 min at 4°C (Optima XPN-100 Ultracentrifuge, Beckman Coulter, with SW60 Ti rotor). Resuspension of the pellet (sub-mitochondrial particles ...
-
bioRxiv - Bioengineering 2023Quote: ... Samples were ultracentrifuged at 100,000×g for 70 min at 4°C using the Beckman OptimaTM L-80 XP ultracentrifuge (Beckman Coulter, CA). The supernatant was discarded ...
-
bioRxiv - Bioengineering 2022Quote: ... Cells were subsequently incubated with 2.5×103 CFSE-RJ-EVs per cell for 4 hours and analyzed with flow cytometry (CyAn ADP, Beckman Coulter, US). Treatment groups were compared to unstained control as well as CFSE-RJ-EVs without inhibitor ...
-
bioRxiv - Cell Biology 2022Quote: Whole bovine milk samples (200 mL) were centrifuged at 3,000 x g for 15 min at 4°C (Allegra X-15R, Beckman Coulter, France) to separate the fat from the skimmed milk ...
-
bioRxiv - Cell Biology 2022Quote: ... After ultracentrifugation at 200,000 x g for 5 h at 4°C (SW55Ti rotor in a XL-90 Beckman Coulter centrifuge), fractions containing purified EVs or purified phages were extracted from the top following the scheme in Supp ...
-
bioRxiv - Biochemistry 2022Quote: ... Soluble and insoluble fractions were isolated via centrifugation (90,000 x g, 30 min, 4 °C) in an Optima™ MAX-OP (Beckman Coulter) centrifuge using the TLA-100.3 rotor ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was recovered and centrifuged at 60,000 rpm for 15 min at 4°C in an Optima TL micro-ultracentrifuges (TLA 100.3 rotor Beckman Coulter, Fullerton, CA) to obtain the Golgi-enriched p100 pellet fraction ...
-
bioRxiv - Physiology 2022Quote: ... 40 ml of filtrates were ultracentrifuged twice in sterile 10.4 mL polycarbonate bottles at 100 000 x g for 70 min at 4°C using an Optima L-100 XP Ultracentrifuge equipped with 90 Ti Fixed-Angle Titanium Rotor (Beckman Coulter). The final EVs pellets were suspended in 200 µl of PBS (Lonza) ...
-
bioRxiv - Microbiology 2022Quote: ... respectively) by centrifugation at 4000 × rpm for 10 min at 4 °C using an Allegra® X-15R centrifuge (Beckman Coulter) and flash-frozen in liquid nitrogen before RNA isolation ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was run on the gradient for 16 hrs at 4 °C using an Optima XE-90 ultracentrifuge (SW40Ti rotor, Beckman-Coulter) at 30,000 rpm ...
-
bioRxiv - Cell Biology 2023Quote: ... and ultracentrifuged at 200,000 × g for 4 hours using a SW 55 Ti rotor in a Beckman OPTIMA90X ultracentrifuge (Beckman Coulter, USA). Finally ...
-
bioRxiv - Biophysics 2023Quote: ... the SWCNT suspension was centrifuged at 30000 rpm (164 000 x g) for 4 h at 25 °C (Optima XPN-80, Beckman Coulter) to remove any remaining nanotube aggregates.
-
bioRxiv - Genomics 2023Quote: ... cellular/protein debris were then collected by centrifugation at 1,000xg for 15 minutes at 4°C (Beckman Coulter Allegra X-14R), and the supernatant (DNA ...
-
bioRxiv - Biophysics 2022Quote: ... EVs were separated from protein aggregates and free reagents by bottom-up density gradient centrifugation in sucrose for 17.30 h at 192,000 g and 4°C using a SW40 rotor (k-factor 144.5; Beckman Coulter, Fullerton, California, USA). Twelve fractions of 1 mL were then collected from the top of the gradient and respective densities were determined by refractometry using an Atago Illuminator (Japan) ...
-
bioRxiv - Plant Biology 2024Quote: ... The tubes were then centrifuged for 20 min at 700 x g with slow acceleration at 4°C using a JA-14 rotor (Avanti J-20 XP centrifuge; Beckman Coulter). The resulting apoplastic wash collected was passed through a 0.22 µm membrane filter to remove bacteria and larger debris ...
-
bioRxiv - Bioengineering 2024Quote: ... we first measured a cell line population in PBS suspension using a coulter counter (Beckman Coulter Multisizer 4, 100 μm aperture) to obtain a cell volume distribution with the standard unit ...
-
bioRxiv - Cell Biology 2024Quote: ... We loaded 2 mL of the homogenate mixture on top of a 3.92 ml 62% sucrose in MAB cushion in an Ultra-Clear 5/8” X 4” Beckman Coulter tube (344061, Beckman Coulter). We added the remaining sucrose in MAB solutions ...
-
bioRxiv - Microbiology 2024Quote: Bacterial isolates were grown overnight on LB agar and DNA extraction was performed using the GenFind v3 gDNA extraction kit according to standard protocol (Supp. Table 4) (Beckman Coulter). For the mock microbial community ...