Labshake search
Citations for Beckman :
1201 - 1250 of 1459 citations for 4 Amino 3 8 dichloro 5 methoxyquinoline since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... Mitochondrial crude was pelleted by centrifugation at 9500 ×g (4 °C, 15 min) using the Optima XE-90 Ultracentrifuge with a Ti-45 rotor (Beckman Coulter). The final pellet was resuspended in 2 mL of Resuspension buffer (250 mM sucrose ...
-
bioRxiv - Bioengineering 2023Quote: ... The suspension was then ultracentrifuged (58,000 × g, 1 hr., 4 °C) in an Optima MAX-XP (Beckman Coulter, Indianapolis, IN, USA) to separate residual catalyst ...
-
bioRxiv - Biochemistry 2023Quote: ... then centrifuged at 27,000 gmax for 15 min at 4°C (Optima XPN-100 Ultracentrifuge, Beckman Coulter, with SW60 Ti rotor). Resuspension of the pellet (sub-mitochondrial particles ...
-
bioRxiv - Cancer Biology 2024Quote: ... cells were resuspended in 100µL of PBS and stored at 4°C in the dark until samples were analyzed on a CytoFLEX LX Flow Cytometer (Beckman Coulter). Data was analyzed using FlowJo® software.
-
bioRxiv - Cell Biology 2024Quote: ... to a volume of ∼12 mL with PBS and separated by ultracentrifugation at 160.000 × g for 2 h (4 °C) in a SW Ti41 rotor (Beckman Coulter #331362). Top-layer LDs were collected by aspiration using a pre-wetted 200 µL pipette tip so that maximal LDs were collected in minimal buffer volume ...
-
bioRxiv - Bioengineering 2024Quote: ... we first measured a cell line population in PBS suspension using a coulter counter (Beckman Coulter Multisizer 4, 100 μm aperture) to obtain a cell volume distribution with the standard unit ...
-
bioRxiv - Biochemistry 2024Quote: ... Non-solubilized materials were removed by centrifuging the sample at 41,000 r.p.m for 1 h at 4 °C using rotor type 45 Ti in the OptimaTM L-100 XP Ultracentrifuge (BECKMAN COULTER). The resulting supernatant containing the solubilized LysP-GFP was incubated with Ni2+-NTA resin (Qiagen ...
-
bioRxiv - Microbiology 2024Quote: ... Samples were balanced and centrifuged at 42,000 rpm for 35m at 4°C in a SW55Ti rotor and buckets with tube adaptors (Beckman REF: 356860). The supernatant was then concentrated to 80μl by spinning through Amicon 3kDa MWCO concentrator units at 14,000xg for 15-30m at 4°C ...
-
bioRxiv - Microbiology 2024Quote: ... and labeled intracellularly for the structural HIV-1 p24 protein with the anti-p24 clone KC57 antibody (30 min RT followed by 30 min 4°C, Beckman Coulter). HIV-1 RNA probing was performed using the PrimeFlow RNA Assay (ThermoFisher) ...
-
bioRxiv - Plant Biology 2024Quote: ... The tubes were then centrifuged for 20 min at 700 x g with slow acceleration at 4°C using a JA-14 rotor (Avanti J-20 XP centrifuge; Beckman Coulter). The resulting apoplastic wash collected was passed through a 0.22 µm membrane filter to remove bacteria and larger debris ...
-
bioRxiv - Microbiology 2024Quote: Bacterial isolates were grown overnight on LB agar and DNA extraction was performed using the GenFind v3 gDNA extraction kit according to standard protocol (Supp. Table 4) (Beckman Coulter). For the mock microbial community ...
-
bioRxiv - Immunology 2020Quote: ... and anti-CD27-PE-Cy5 (clone 1A4CD27; 2.5 μL; cat. # 6607107) and anti-NKG2A-APC (clone Z199; 5 μL; cat. # A60797) from Beckman Coulter (Supplementary Fig ...
-
bioRxiv - Biochemistry 2020Quote: ... The cultures were grown until OD600 of 0.8 at 37 °C and the cells were collected by centrifugation at 8,000 rpm for 5 minutes in JLA-16.25 rotor (Beckman Coulter), dissolved in 0.5 mL of HEPES:Polymix buffer ...
-
bioRxiv - Microbiology 2021Quote: ... liquid-captured bioaerosols (5 – 10 mL) were centrifuged for 10 minutes at 3000 × g (Allegra X-15R, Beckman Coulter) and resuspended in 200 μL of Middlebrook 7H9 medium supplemented with 100 μM DMN-tre ...
-
bioRxiv - Cell Biology 2021Quote: ... and the mixtures were ultracentrifuged at 80,000 rpm for 5 min at 30 °C using a TLA100 rotor and an Optima TLX ultracentrifuge (Beckman). The microtubule pellets were resuspended in PEM supplemented with 1 mM DTT ...
-
bioRxiv - Cell Biology 2020Quote: ... and 5 % solutions on top of each other in a 13.2 ml open-top polyallomer tube (331372, Beckman Coulter). The 1 ml concentrates were overlaid on top of the gradient ...
-
bioRxiv - Microbiology 2021Quote: ... Linear sucrose gradients were prepared by layering 1.8 ml each of sucrose solutions (wt/wt; prepared in 5 mM EDTA, pH 7.5) into 14-by 95-mm ultracentrifuge tubes (Beckman) in the following order ...
-
bioRxiv - Cancer Biology 2020Quote: ... equivalent amounts of ribosomes for each lysate was loaded onto each 10%-45% sucrose density gradient (BioComp Gradient Master machine) for ultracentrifugation at 33,000 rpm for 5 hours (Beckman Optima L80K Ultracentrifuge ...
-
bioRxiv - Microbiology 2022Quote: ... Cells were grown for additional 1 hour at 30 °C and the biomass was harvested by centrifugation (10,000 rpm, for 5 minutes, JLA-10.500 rotor (Beckman Coulter)).
-
bioRxiv - Biochemistry 2019Quote: ... The cell lysates were subjected to two rounds of centrifugation at 18000 rpm for 5 and 30 mins in a JA-25.50 rotor (Beckman). Bradford assay was used to normalize protein levels for co-immunoprecipitation and immunoblot analysis ...
-
bioRxiv - Genetics 2020Quote: ... 5 μL of each PCR reaction from the single worm lysate was pooled and purified by SPRI (Beckman Coutler) to remove unincorporated oligos ...
-
bioRxiv - Immunology 2021Quote: ... Soluble CuMV-CP-containing protein solution was separated from the cellular proteins by ultracentrifugation in a sucrose gradient (20%-60% sucrose; ultracentrifugation at 25,000 rpm for 6 hours at 5°C [SW28 rotor, Beckman]). After dialysis CuMVTT-containing gradient fractions ...
-
bioRxiv - Microbiology 2020Quote: ... The sample was vortexed for 10 s and incubated at room temperature for 5 minutes before centrifugation at 12,000 rpm (JA-15 1.5 rotor, Beckman Coulter) 4°C for 5 minutes ...
-
bioRxiv - Cell Biology 2022Quote: ... Resuspended pellets were then subjected to an iodixanol density gradient in 5-mL Ultra-Clear centrifuge tubes (Beckman Coulter). The tubes were first filled with a two-layer gradient ...
-
bioRxiv - Cell Biology 2022Quote: ... were mixed 1:1 with liposomes (5 mg/ml) and floated for 2h at 55,000 rpm in a TLS-55 rotor (Beckman) at 25 °C through a sucrose gradient ...
-
bioRxiv - Cell Biology 2022Quote: ... The stock solution of aggregate-depleted BSA (5% w/v) was prepared by overnight centrifugation at 100,000 x g (SW28 rotor Beckman Coulter ...
-
bioRxiv - Cell Biology 2022Quote: ... and 3.5 mL of 5% iodixanol in a 16.8 mL open top polyallomer tube (Beckman Coulter, Fullerton, California, USA). One milliliter of concentrated conditioned medium was pipetted on top of the gradient and samples were centrifuged for 18 h at 100,000 ×g and 4 °C using a SW 32.1 Ti rotor (Beckman Coulter ...
-
bioRxiv - Microbiology 2024Quote: ... respectively) were gently layered on top of each other in ultracentrifuge tubes (Ultra-Clear 5 mL Tube, Beckman Coulter) and a continuous gradient was generated using a gradient maker (Gradient Master ...
-
bioRxiv - Microbiology 2024Quote: ... The phage was purified by isopycnic centrifugation in a CsCl discontinuous gradient for 5 h at 32,000 rpm in a SW41 rotor (Beckman) at 20°C ...
-
bioRxiv - Neuroscience 2023Quote: ... after which the cells were harvested by centrifugation at 4,000 rpm for 30 min at 5°C using the JLA 8.1000 rotor (Beckman Coulter). The harvested pellets were stored at −20°C until use ...
-
bioRxiv - Microbiology 2022Quote: ... the stained cells were detached by 5 mM of EDTA/PBS and analyzed with a CytoFLEX Flow Cytometer (Beckman). 10,000 events in a gated live cell population (based on SSC/FSC ...
-
bioRxiv - Plant Biology 2023Quote: ... Cell debris was removed by centrifugation at 1,300 g for 5 min (Beckman Centrifuge Avanti® J-26-XP). Afterwards ...
-
bioRxiv - Cancer Biology 2023Quote: ... Percentage of cells with each DNA content (2N, 3N, 4N, 5-8N) were estimated using CytExpert software (Beckman Coulter). For DNA content analysis using sorted cells ...
-
bioRxiv - Neuroscience 2024Quote: ... but 2.5 mL for 5%) and ultracentrifuged at 100,000 x g (SW 40 Ti or SW41 Ti rotor, Beckman Coulter) for 16 h using ultra-clear tubes (Beckman Coulter ...
-
bioRxiv - Cell Biology 2024Quote: ... 10% and 0% in buffered sucrose on top of one another in 5 ml Ultra-Clear centrifuge tubes (Beckman). Gradients were centrifuged for 16 h at 100,000 x g and 4 °C ...
-
bioRxiv - Molecular Biology 2024Quote: ... Cell lysates were subjected to two rounds of centrifugation at 18000 rpm for 5 and 30 mins in a JA-25.50 rotor (Beckman). Protein levels were normalized for coimmunoprecipitation and immunoblot analysis using a Bradford Assay ...
-
bioRxiv - Biochemistry 2023Quote: ... Colorimetric changes was measured 3 min after mixing the conditioned media with DTNB solution at 450 nm of absorbance (DTX880, Beckman Coulter, Indianapolis, IN, USA). The value from DTNB only was substracted as noise ...
-
bioRxiv - Biophysics 2021Quote: ... which were centrifuged at 3000 rpm for 15 minutes at 4°C using a fixed angle centrifuge (Beckman Coulter, Brea, CA, USA). After removal of excess supernatant ...
-
bioRxiv - Biophysics 2020Quote: ... The lysates were clarified by centrifugation (16,000 rpm for 1 h at 4°C, rotor JA 25.50, Beckman Coulter, Brea, California, USA). The supernatant was incubated with amylose resin for 1 h at 4°C and loaded onto a 20 ml chromatography column (Bio-Rad ...
-
bioRxiv - Cancer Biology 2021Quote: Proliferation of IL-32 KO and WT mock cells was assessed by cell counting every day for 4 days using cell coulter (Beckman Coulter Diagnostics). Cell viability was assessed by Trypan blue staining or by annexin/PI flow cytometry and analyzed by FACS Diva software (BD Biosciences).
-
bioRxiv - Immunology 2021Quote: ... The pelleted exosomes from above supernatants were further centrifuged at 100,000g (26,450rpm) for 2 h at 4 °C (Beckman Coulter, Optima XE-90) and resuspended in PBS ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were centrifuged at 130,000 × g for 2 h at 4°C in a TLA100.3 rotor (Beckman Optima TLX table top centrifuge). Following centrifugation ...
-
bioRxiv - Systems Biology 2020Quote: ... Next the cultures were diluted 1:40 with 0.5M NaCl and immediately measured in Multisizer™4 COULTER COUNTER® (Beckman Coulter) (Coulter ...
-
bioRxiv - Neuroscience 2021Quote: ... The post nuclear supernatant was transferred to an ultracentrifuge tube and centrifuged for 2 h at 245,000 g at 4 °C in a Beckman L90 Ultracentrifuge (Beckman Coulter, Mississauga, Canada) to pellet remaining membrane.
-
bioRxiv - Biophysics 2022Quote: ... The tubes were filled with PBS to reach the final volume and samples were ultracentrifuged at 120,000 g for 60 minutes at 4°C (70.1 Ti rotor, k-factor 36, Beckman Coulter, Brea, CA, USA). Finally ...
-
bioRxiv - Molecular Biology 2019Quote: ... was clarified by centrifugation at 10,000 rpm for 30 min at 4 °C using an SW-28 rotor in an Optima L-90K Ultracentrifuge (Beckman Coulter, USA) and was then ultracentrifuged at 25,000 rpm for 6 h at 4 °C using the same rotor ...
-
bioRxiv - Molecular Biology 2019Quote: ... was loaded onto 4 ml of a 10% −30% (w/v) linear sucrose gradient and centrifuged at 74,000g at 4°C for 6 h (Beckman MLS-50 rotor). Fractions (250 µl ...
-
bioRxiv - Molecular Biology 2019Quote: ... The DG was centrifuged 18 h at 100,000 g and 4 °C using SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Density fractions of 1 ml were collected and fractions 9-10 pooled ...
-
bioRxiv - Plant Biology 2020Quote: ... All samples were centrifuged in a single 2 h run with sedimentation at 50,000 g and 4°C using small 13 x 51 mm ultracentrifugation tubes in SW55 Ti rotor (Beckman Coulter, Krefeld, Germany). These centrifugation settings were optimized for polysome and monosome separations ...
-
bioRxiv - Cell Biology 2020Quote: ... Vacuoles were separated from free dye by centrifugation (100,000 x g, 25 min, 4°C, SW-60 Ti rotor, Beckman L8-80M Ultracentrifuge) and recovered from the 0%-4% interface ...