bioRxiv - Bioengineering 2021Quote: ... The resulting supernatant was then ultracentrifuged at 50,000 RPM and 4 °C for 90 minutes using a 70.1 Ti rotor (Beckman Coulter, Brea, CA, USA) with 1 mL 15% sucrose cushion per tube ...
-
bioRxiv - Cell Biology 2021Quote: ... The samples were centrifuged at 60,000 rpm at 4°C for 2hr in an SW65 Ti ultracentrifuge rotor (Beckman Coulter, California, USA). The translucent polysome pellets were washed by gently dispensing and removing 500 µl of ice-cold RNase-free water ...
-
bioRxiv - Microbiology 2020Quote: ... RNA was pelleted by centrifugation for 24 h at 4 °C and 104.000 g in a SW28.1 swing out rotor (Beckman Coulter, Brea, CA, USA). RNA was taken up in 100 µl H2O and 500 µl TS buffer was added ...
-
bioRxiv - Molecular Biology 2020Quote: ... the serum was centrifuged (200,000xg, at 4°C for 18 hours) using a Beckman Coulter Optima XE-100 Ultracentrifuge (Beckman Coulter, CA, USA), with a SW41Ti rotor (Beckman Coulter ...
-
bioRxiv - Neuroscience 2022Quote: ... The crude viral lysate was purified with two rounds of CsCl gradient ultracentrifugation at 100,000×g and 4°C for 23 h using 13.5-mL Quick-Seal tubes and a NVT65 rotor (Beckman Coulter, Brea, CA). Each tube was placed gently and 500– 750 µL of white turbid bands were collected ...
-
bioRxiv - Molecular Biology 2022Quote: ... were pre-clarified to remove aggregate proteins by spinning at 65,000 rpm for 30 min at 4°C in a TLA100 rotor (Beckman Coulter, Brea, CA) before incubating with F-actin ...
-
bioRxiv - Microbiology 2022Quote: ... virions collected over the three passages were concentrated on 20% sucrose cushions (prepared in 1X phosphate buffered saline (PBS)) by ultracentrifugation (28000 rpm, 4°C, 90min, Beckman SW41 rotor). Genomic RNA was isolated from pelleted virions using Trizol per manufacturer’s instructions ...
-
bioRxiv - Biophysics 2022Quote: ... A 5 to 30% linear sucrose gradient was formed above the homogenate and centrifuged at 40,100 rpm and 4° C for 16 hours in a SW55 rotor using an OptimaTM LE-80K Ultracentrifuge (Beckman Coulter, Pasadena, CA). Fourteen 360 μl fractions were collected from the top and analyzed by SDS–PAGE/Western blot with an equal loading volume ...
-
bioRxiv - Cell Biology 2022Quote: ... and centrifuged at 16000 ×g for 3 hours at 4 °C in an Avanti J-25 centrifuge (Beckman Coulter Life Sciences, USA) with a JA-25.50 fixed-angle aluminum rotor (Beckman Coulter Life Sciences ...
-
bioRxiv - Neuroscience 2020Quote: ... and 1.5 ml of this was added to the top of the sucrose gradient and was centrifuged at 69,150 x g for 70 min at 4°C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. # 331362). 1–1.5 ml of the synaptosome layer was collected from the interface of the two sucrose layers ...
-
bioRxiv - Biophysics 2020Quote: ... cell lysate was centrifuged by using The Beckman Optima™ L-80 XP Ultracentrifuge at 40000 rpm for 30 minutes at 4°C by using Ti45 rotor (Beckman, USA). After ultracentrifugation the pellet which contains membranes and insoluble debris was discarded and clear supernatant applied to nickel affinity chromatography by using a Ni-NTA agarose resin (QIAGEN ...
-
bioRxiv - Microbiology 2020Quote: ... the Exos were washed three times with PBS before ultracentrifugation at 100,000□x□g for 20□min at 4□°C using Beckman L7-80 and rotor SW41 (Beckman Coulter, Indianapolis, IN) to remove unbound stain ...
-
bioRxiv - Biochemistry 2020Quote: ... which was then centrifuged at 160,000×g at 4°C for 16 h in a Beckman MLS–50 rotor (Beckman–Coulter, CA, USA), and 24 fractions were collected ...
-
bioRxiv - Microbiology 2020Quote: ... were further purified by centrifugation through a 1.2 g/cm3 to 1.6 g/cm3 cesium chloride density gradient at 50,000 RPM for 4 hours at 11 °C in a Beckman SW 65 Ti rotor (Beckman Coulter, Brea, California). Visible “virus bands” in the gradients were collected using a Hamilton syringe and diluted 1:10 in 10 mM Tris-HCl ...
-
bioRxiv - Microbiology 2020Quote: ... virions were purified from the infected S2 cells by centrifugation at 8,000 RPM for 10 minutes at 4 °C using a Beckman GSA rotor (Beckman Coulter, Brea, California). The supernatant was then collected and centrifuged at 8,000 RPM for 30 minutes at 4 °C using a Beckman GSA rotor ...
-
bioRxiv - Plant Biology 2020Quote: ... Double size selection was carried out by adding 50 μL of a 1:4 (0.5X) mixture of AMPure XP Beads (Beckman Coulter, Brea, USA) to PEG buffer (20% PEG w/v ...
-
bioRxiv - Molecular Biology 2021Quote: ... sucrose gradients prepared with lysis buffer without Triton X100 and centrifuged at 32,000 rpm for 3 hrs at 4 °C in an SW41Ti rotor (Beckman Coulter, Cat:331362). The sucrose gradients were fractionated using BR-188 Density Gradient Fractionation System with 60% (m/v ...
-
bioRxiv - Immunology 2021Quote: ... Cell debris was removed by centrifugation (45 min at 18,000 rpm, at 4°C; Avanti® J-26xp centrifuge (BECKMAN COULTER®)) ...
-
bioRxiv - Cell Biology 2020Quote: ... The insect cells were harvested after 4 days by centrifugation at 300 x g for 10 min at 4 °C in an Avanti J-26S ultracentrifuge (JLA-9.1000 rotor, Beckman Coulter, Brea, CA). The cell pellet was resuspended in 5 ml ice-cold PBS and stored at −80 °C for further use ...
-
bioRxiv - Cell Biology 2020Quote: ... and centrifuged at 45.000 x g for 60 min at 4 °C in the Avanti J-26S ultracentrifuge (JA-30.50Ti rotor, Beckman Coulter, Brea, CA). The cleared cell lysate was incubated for 2 h at 4 °C in a lysis buffer-equilibrated Ni-NTA column (HisPur Ni-NTA Superflow Agarose ...
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 100 000 × g for 60 min at 4°C using rotor Ti-70 in an Optima LE-80K Ultra Centrifuge (Beckman Coulter, Australia). The harvested EV pellet was resuspended in 1 mL RNase-free Phosphate buffered saline (RNase-free PBS ...
-
bioRxiv - Neuroscience 2021Quote: ... Lentiviruses were purified by overlaying the virus containing media over a 20% sucrose solution before ultracentrifugation at 26,000 rpm for 90 minutes at 4 °C in a SW28Ti swinging-bucket ultracentrifuge rotor assembly in an Optima XPN-80 Ultracentrifuge (Beckman Optima Ultracentrifuge) and the viral pellet was resuspended in AimV™ media.
-
bioRxiv - Cell Biology 2020Quote: ... supernatants were centrifuged at 10,000 x g for 30 min at 4°C and the supernatants were transferred to ultracentrifuge tubes (Beckman Coulter, Brea, CA) and diluted with phosphate-buffered saline (PBS) ...
-
bioRxiv - Microbiology 2020Quote: ... All bacteria were harvested by centrifugation at 4000 rpm and 4°C in a JS 4.0 swinging bucket rotor (Beckman Coulter, Brea California) and immediately processed as described below.
-
bioRxiv - Microbiology 2021Quote: ... density gradient (35 to 0% in PBS) and ultracentrifuged at 200,000 × g for at least 12 hours at 4 °C (Beckman Optima XL-100K). The corresponding clear yellow band was collected ...
-
bioRxiv - Cell Biology 2022Quote: ... The resulting supernatant was centrifuged at 10,000 x g for 30 minutes to remove any remaining debris and then ultra-centrifuged at 118,000 x g for 70 minutes at 4°C with a fixed-angle rotor (Ti-70, Beckman Coulter, Brea, CA). The pellet was washed with sterile 1X PBS and subjected to another cycle of ultracentrifugation at 118,000 x g for 70 minutes at 4°C ...
-
bioRxiv - Cancer Biology 2022Quote: ... The supernatants were further centrifuged at 10,000 × g for 30 min at 4°C to remove remaining cell debris and at 100,000 × g (Type 90 Ti Rotor, Beckman, Brea, CA, USA) overnight at 4°C to remove exosomes ...
-
bioRxiv - Biochemistry 2022Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
Isolation and characterization of a novel phage of Vibrio parahaemolyticus with biocontrol potentialbioRxiv - Microbiology 2022Quote: ... for purification and centrifuged at 200,000 × g at 4°C for 24 h using an Optima L-100 XP ultracentrifuge (Beckman Coulter, CA, USA). The purified phage particles were dialyzed through 30-kDa superfilters (Millipore ...
-
bioRxiv - Neuroscience 2023Quote: ... re-suspend in the homogenization buffer and centrifuged at 100,000 x g for 40 min at 4°C (Beckman SWTi41 swing rotor). The pellet containing the growth cone were re-suspended in 50 μl of the homogenization buffer ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Biochemistry 2022Quote: ... The supernatant was again centrifuged at 100000 g for 45 min at 4°C (Beckman Optima™ MAX-XP Rotor MLS-50). After filtering the supernatant through a 0.22 μm syringe filter ...
-
bioRxiv - Cell Biology 2022Quote: ... One milliliter of concentrated conditioned medium was pipetted on top of the gradient and samples were centrifuged for 18 h at 100,000 ×g and 4 °C using a SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Fractions of 1 mL were collected from the top and EV-rich fractions 9 and 10 (corresponding to a density of 1.10-1.12 g/mL ...
-
bioRxiv - Microbiology 2024Quote: ... Saliva was collected by expectoration into tubes on ice followed by centrifugation for 10 minutes at 4°C at 4000 x g (Beckman SX4750 rotor) to remove large debris and bacterial aggregates ...
-
bioRxiv - Biochemistry 2023Quote: ... Cultures were then recovered by centrifugation (4,000 x g, 4 °C, 40 min in a Beckman Avanti JXN-26 (rotor: JLA 8.1)) and pellets resuspended in approximatively 30 mL of lysis buffer (20 mM HEPES ...
-
bioRxiv - Molecular Biology 2024Quote: ... ADEV isolation was performed by ultracentrifugation at 100,000 × g for 14 h at 4 °C (swing bucket rotor on minimum acceleration/break setting, SW 32Ti Beckman Coulter, Brea, CA), and ADEVs were resuspended in 200μL PBS and stored at −20°C until used16,41 ...
-
bioRxiv - Cell Biology 2023Quote: ... Following centrifugation at 131,300 × g for 24 hr at 4 °C using a MLS-50 Swinging-Bucket rotor (Beckman Coulter, Brea, CA) to sediment protein complexes ...
-
bioRxiv - Cell Biology 2024Quote: ... All centrifugation steps were done at 4°C and the last two steps were performed using Optima XE-90 ultracentrifuge (Beckman Coulter, A94471) with rotor SW32Ti (Beckman Coulter ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was clarified by centrifugation at 5500 rpm for 20 min at 4°C (AllegraTM 21R Centrifuge, Beckman Coulter, CA, USA). The sample was then loaded into a HisTrap HP 5 mL column (Cytiva ...
-
bioRxiv - Neuroscience 2023Quote: ... then spun at 100,000 x g for 30 min at 4°C in an ultracentrifuge (Beckman OPTIMA TLX with TLA-100.3 rotor). The supernatant was saved and the pellet went through a series of similar extractions using High-Salt Triton Buffer (High-Salt Buffer ...
-
bioRxiv - Neuroscience 2023Quote: ... The supernatants were then combined and centrifuged at 17,000g for 10min at 4°C in a Beckman SW41-Ti rotor (Beckman Coulter, Brea, CA). The supernatant was saved as the cytosolic (CYT ...
-
bioRxiv - Cell Biology 2023Quote: Myf5High and Myf5Low MuSCs were isolated from a pool of 4 male and 4 female mice and repeated in two independent experiments and total RNA was extracted using Agencourt RNAdvance tissue Kit (Beckman Coulter, #A32646) with a quality score of RQN 9.3 to 10 ...
-
bioRxiv - Cell Biology 2023Quote: ... was next subjected to ultracentrifugation at 120,000 × g for 4 h in a SW 28 Ti Swinging-Bucket Rotor (Beckman Coulter, Fullerton, CA) to sediment small EVs ...
-
bioRxiv - Biochemistry 2023Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were incubated further overnight at 20°C and subsequently harvested by centrifugation (Beckman rotor 8.1000, 5000 rpm, 15 min, 4°C). The pellet was resuspended in PBS ...
-
bioRxiv - Biochemistry 2023Quote: ... by centrifugation at 80,000 × g for 30 min at 4°C using a TLS-55 rotor (Beckman Coulter Inc., Miami, FL, USA). Crista membranes were identified and removed based on fluorescence under a UV lamp ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Biophysics 2024Quote: ... Samples were centrifuged at 24,000 rotations per minute using an S-28 rotor at 4◦C in an Optima XL-100K Ultracentrifuge (Beckman Coulter, Brea, CA). The supernatant was decanted ...