Labshake search
Citations for Beckman :
1101 - 1150 of 1547 citations for Mouse Anti Hepatitis C Virus NS3 Antibody 1828 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2022Quote: ... and the supernatant was subjected to ultracentrifugation to separate the membrane fraction (100,000g, 1 hour, 4°C using an Optima XE-90, Beckman Coulter centrifuge). Membranes were resuspended in lysis buffer supplemented with cOmplete EDTA-free protease inhibitors (Roche) ...
-
bioRxiv - Microbiology 2022Quote: ... through a syringe needle (0.4-by 20 mm needles) and the cell wall was collected by ultracentrifugation at 90,000 × g for 45 min at 4°C (Beckman Coulter, Inc.). To the pellet ...
-
bioRxiv - Bioengineering 2022Quote: ... The final supernatant was collected and EVs were pelleted at 100,000 g at 4°C for four hours in an Optima ultracentrifuge using the Beckman Ti45 rotor (Beckman Coulter, USA). The EVs pellet was washed with PBS and resuspended in 0.22 μm filtered PBS ...
-
bioRxiv - Cell Biology 2022Quote: ... A new supernatant was collected in a prechilled 1.5 ml ultracentrifuge tube and centrifuged at 100000 g for 1 h at 4°C in a TLA-55 rotor (Beckman Coulter). The resulting pellet was resuspended in the same isotonic buffer containing antiproteases and was frozen at -80°C together with the 100000 g supernatant ...
-
bioRxiv - Biochemistry 2021Quote: ... Cells were incubated for 2h at 20°C in an AN60-Ti rotor in the Optima-AUC analytical ultracentrifuge (Beckman Coulter) before data acquisition for 15h at 42,000 rpm ...
-
bioRxiv - Microbiology 2021Quote: ... Cell supernatants containing the pseudotype viral particles were centrifuged at 109,000 g or 35 min at 4 °C using a TLA100.3 rotor with an Optima TLX ultracentrifuge (Beckman Coulter, CA, USA), and the pellet was then lysed for western blotting analysis.
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Molecular Biology 2020Quote: ... The filtered supernatant was then centrifuged in JA20 tubes at 6000 rpm overnight (O/N) at 4°C (Avanti J-25, Beckman Coulter). The following day the viral pellet was resuspended in 5 ml PBS and centrifuged at 20,000 rpm for 90 mins at 4°C (Optima XL-100K ...
-
bioRxiv - Molecular Biology 2019Quote: ... Centrifugation was performed at 22 °C for 3 h at 217 874 g using a SW 40 Ti rotor (Beckman Coulter). Fractions of 600 µl were carefully collected manually ...
-
bioRxiv - Molecular Biology 2020Quote: ... The gradients were centrifuged at 40000 rpm for 2h at 4°C in a SW 60 Ti swinging-bucket rotor (Beckman Coulter). Afterwards ...
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 100,000 g at 4°C for 60 min in a swinging rotor (SW40Ti) (Beckman Coulter OptimaTM L–100K). Following centrifugation ...
-
Single cell analysis of the cellular heterogeneity and interactions in the injured mouse spinal cordbioRxiv - Neuroscience 2020Quote: ... were added to each sample well and cells were kept at 4°C until analysis on a Cytoflex Flow Cytometer (Beckman Coulter).
-
bioRxiv - Cell Biology 2020Quote: ... were pelleted in Beckman Coulter polypropylene open top tubes (110,000 x g for 70 min at 4°C, in Beckman rotor SW28). After washing ...
-
bioRxiv - Microbiology 2022Quote: ... and the viral particles were concentrated by ultracentrifugation for 1h at 30,000 rpm at 4°C in an SW40 rotor (Beckman, Fullerton, CA). Viral pellets were resuspended in TNC buffer (10 mM Tris-HCl [pH 7.5] ...
-
bioRxiv - Genetics 2022Quote: ... A final DNase treatment was performed in 50 μL total volume using 1 μL of Turbo DNase incubated for 4 hours at 37°C followed by inactivation with 1 μL of 10% SDS and purification using RNA Ampure XP beads (Beckman Coulter).
-
bioRxiv - Developmental Biology 2022Quote: ... proteinase K and heat for de-crosslinking (overnight at 65°C) followed by ethanol precipitation and SPRI bead clean up (Beckman Coulter). The resulting DNA was quantified by Clariostar (BMG Labtech) ...
-
bioRxiv - Microbiology 2022Quote: ... Samples were incubated for 2 h at 16°C and double stranded cDNA was purified using AMPure XP beads (Beckman Coulter). For testing transcription activity of predicted genes ...
-
bioRxiv - Cancer Biology 2022Quote: ... Crude vesicle pellets were resuspended in 1 ml of exosome-depleted 1X PBS and re-pelleted by centrifugation at 100,000 g for 70 minutes at 4°C (Beckman 45 Ti). Pellets at the bottom of the centrifugation tubes were resuspended in approximately 50ul of 1X PBS ...
-
bioRxiv - Systems Biology 2020Quote: ... The resultant supernatant was collected and underwent ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor MLA-55) in 10.4 ml 16×76 mm polycarbonate capped centrifuge tubes (Beckman Coulter 355603), the pellet was washed once in PBS−/− and centrifuged again at 100,000xg for 40 minutes at 4°C ...
-
bioRxiv - Molecular Biology 2019Quote: ... EDS was obtained after 18 h ultracentrifugation at 100,000 g and 4 °C (SW55 Ti rotor, Beckman Coulter, Fullerton, California, USA), followed by 0.22 µm filtration ...
-
bioRxiv - Molecular Biology 2019Quote: ... followed by 3 h ultracentrifugation at 100,000 g and 4 °C using SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Resulting pellets were resuspended in 100 µl PBS and stored at −80 °C until further use ...
-
bioRxiv - Microbiology 2019Quote: ... The concentrated vesicles were washed twice with PBS by ultracentrifugation at 110,000xg at 4°C for 1 hour (Beckman Optma MAX-XP Ultracentrifuge, rotor TLA 120.2; Beckman Coulter Inc., USA). The final pellet (exosomes ...
-
bioRxiv - Biophysics 2019Quote: ... to final volume of 12 ml and then spun at 15°C for 16hr at 155,000g using a SW 41Ti rotor (Beckman Coulter, CA). The VLPs were detected at the lower part of the tube and recovered as described above ...
-
bioRxiv - Cancer Biology 2019Quote: ... Gradients were ultra-centrifuged at 221,600 × g for 2 hours at 4°C (SW-41Ti rotor, 331362, Beckman Coulter, Brea, CA). Gradients were fractionated (Piston Fractionator ...
-
bioRxiv - Genomics 2019Quote: ... Cleared cell extracts were ultracentifuged at 34400 rpm for 2 hours 40 minutes at 4C using a C-1000 XP centrifuge with SW40 rotor (Beckman Coulter). Gradient UV absorption at 254 nm was measured and selected fractions were selected for 5’cap library preparation (5µg purigied RNA per sample) ...
-
bioRxiv - Molecular Biology 2020Quote: ... the lysate was incubated under rotation for 30 min at 4 °C and cleared for 10 min in an MLA-80 rotor (Beckman Coulter) at 11,500 xg and 4 °C ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was ultracentrifuged at 120,000 g for 3 h at 4°C using an MLS-50 rotor (Beckman Coulter, USA) to collect 120k pellet vesicles ...
-
bioRxiv - Immunology 2021Quote: ... To sort specific subsets of C-LP mononuclear phagocytes cells were gated as above and sorted by MoFlo Astrios Sorter (Beckman Coulter).
-
bioRxiv - Biochemistry 2019Quote: ... Gradients were centrifuged at 49,123 x g for 16 hours at 4°C using an SW32Ti rotor (Beckman Coulter, ref. 369694). Gradients were fractionated with a Brandel gradient fractionation system using a 1 mm UV cell detector ...
-
bioRxiv - Systems Biology 2020Quote: ... the 500xg supernatant was first spun at 10,000xg for 10 minutes at 4°C (Beckman Coulter, fixed angle rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778) ...
-
bioRxiv - Microbiology 2019Quote: ... saliva EVs were pelleted by ultracentrifugation at 100,000 × g for 90 min at 4 °C (Optima™ Max-XP, Beckman Coulter). The EVs were washed in 2 ml PBS and pelleted again at 100,000 × g for 90 min and suspended in PBS ...
-
bioRxiv - Systems Biology 2020Quote: ... each resultant fraction underwent separate ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778). In EV-enriched pooled fraction experiments ...
-
bioRxiv - Systems Biology 2020Quote: ... and underwent ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor MLA-55; Beckman Coulter 355603 10.4 ml capped tubes). Supernatant was discarded from each fraction ...
-
bioRxiv - Biophysics 2019Quote: ... Samples were loaded onto the gradient and spun at 15°C for 4h at 140,000g using a SW28 rotor (Beckman Coulter, CA). The VLPs appeared as an opaque band at the interface of the 1.25 and 1.4 g/ml CsCl layers and were collected by piercing the tube with an 18G needle and syringe ...
-
bioRxiv - Genetics 2020Quote: ... Reverse crosslinking reactions were incubated 2 h at 65°C and cleaned using Agencourt Ampure XP SPRI beads (Cat #A63880, Beckman Coulter) with a 2x bead:sample ratio ...
-
bioRxiv - Cell Biology 2020Quote: ... 50 µl of alkaline carbonate treated mitochondria were set aside as input (kept on ice) and 50 µl were centrifuged at 100 000g for 30 min at 4°C in TLA100 rotor (Beckman Coulter). Pellet was gently washed with ice-cold sodium carbonate buffer and resuspended in 20 µl of 1x Laemmli loading buffer ...
-
bioRxiv - Microbiology 2020Quote: ... Vesicles were obtained by centrifugation at 38,400 x g for 1 h at 4°C in an Avanti J-20XP centrifuge (Beckman Coulter, Inc). Pelleted vesicles were resuspended in 20 ml of 50 mM HEPES (pH 6.8 ...
-
bioRxiv - Microbiology 2021Quote: ... with a final extension at 72 °C for 10 min PCR products were purified using Agencourt AMPure XP beads (Beckman Coulter) ratio 0.6× ...
-
bioRxiv - Immunology 2020Quote: Intracellular cytokine production by T cells was analyzed after stimulating PBMC or whole blood (fresh or frozen) 4h at 37°C in DurActive1 tubes (Beckman Coulter), which contain PMA ...
-
bioRxiv - Molecular Biology 2021Quote: ... The samples were then separated into membrane and matrix fractions by ultracentrifugation at 100 000 g (TLA 110 rotor) for 30 min at 4°C in OptimaTM TLX table-top ultracentrifuge (Beckman-Coulter). The supernatant fraction was transferred to new tube ...
-
bioRxiv - Immunology 2020Quote: ... and the boundary layers between the two sucrose layers were harvested after ultracentrifugation (90 min, 51,000 rpm, 18 °C, Optima™ L90K centrifuge, rotor type: 70.1 Ti, tubes: 16 * 76 mm, Beckman Coulter, USA). These fractions were subsequently mixed with 6 M CsCl (AppliChem ...
-
bioRxiv - Immunology 2021Quote: ... Samples were spun at 76,650 x g for 2 hours at 4° C inside a SW 32i rotor using an Optima L-90K Ultracentrifuge (Beckman Coulter). Purified virus was quantified using a bicinchoninic acid assay (BCA ...
-
bioRxiv - Immunology 2021Quote: ... Insoluble proteins and cell debris were removed by centrifugation (13,000 rpm, 30 minutes at 5°C, JA-30.50Ti rotor, Beckman, Palo Alto, CA). The soluble CuMVTT CP protein in clarified lysate was pelleted using saturated ammonium sulfate (1:1 ...
-
bioRxiv - Genomics 2021Quote: ... The samples were then centrifuged at 28,600 rpm for 2 h at 4°C (Beckman Optima XE-90; SW32 Ti rotor). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... Vesicles recovered by ultracentrifugation of filtered supernatant at 150,000 x g for 2 h at 4 °C using a Ti 45 rotor (Beckman Instruments, USA), were washed with phosphate-buffered saline (PBS ...
-
bioRxiv - Cell Biology 2022Quote: Whole bovine milk samples (200 mL) were centrifuged at 3,000 x g for 15 min at 4°C (Allegra X-15R, Beckman Coulter, France) to separate the fat from the skimmed milk ...
-
bioRxiv - Cell Biology 2022Quote: ... After ultracentrifugation at 200,000 x g for 5 h at 4°C (SW55Ti rotor in a XL-90 Beckman Coulter centrifuge), fractions containing purified EVs or purified phages were extracted from the top following the scheme in Supp ...
-
bioRxiv - Biochemistry 2022Quote: ... Soluble and insoluble fractions were isolated via centrifugation (90,000 x g, 30 min, 4 °C) in an Optima™ MAX-OP (Beckman Coulter) centrifuge using the TLA-100.3 rotor ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was recovered and centrifuged at 60,000 rpm for 15 min at 4°C in an Optima TL micro-ultracentrifuges (TLA 100.3 rotor Beckman Coulter, Fullerton, CA) to obtain the Golgi-enriched p100 pellet fraction ...
-
bioRxiv - Physiology 2022Quote: ... 40 ml of filtrates were ultracentrifuged twice in sterile 10.4 mL polycarbonate bottles at 100 000 x g for 70 min at 4°C using an Optima L-100 XP Ultracentrifuge equipped with 90 Ti Fixed-Angle Titanium Rotor (Beckman Coulter). The final EVs pellets were suspended in 200 µl of PBS (Lonza) ...