951 - 1000 of 1789 citations for 1 Piperidin 4 yl azetidine 3 carboxylic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... The gradient was centrifuged for 2.30 hours at 4 °C and 111,000 ×g in a swing-out rotor (Beckman- Coulter, SW41). The brownish lysosome-enriched fraction (∼ 1ml ...
-
bioRxiv - Cancer Biology 2023Quote: ... The gradients were ultracentrifuged at 35,000 rpm for 2 hrs at 4°C using an SW41 Ti rotor (Beckman Coulter). The gradients were then displaced into a UA-6 continuous UV detector (Teledyne ISCO ...
-
bioRxiv - Cell Biology 2023Quote: ... Small EVs were isolated by ultracentrifugation at 120,000 x g and 4°C for 120 min using Optima XE-90 equipment with a SW32Ti rotor (Beckman Coulter). Supernatants were discarded using a pipette ...
-
Centriole and transition zone structures in photoreceptor cilia revealed by cryo-electron tomographybioRxiv - Cell Biology 2023Quote: ... OptiPrep step-gradient and centrifuged for 60 min at 19,210 × g at 4 °C in a TLS-55 rotor (Beckman Coulter). The ROS band was collected with an 18G needle ...
-
bioRxiv - Cell Biology 2023Quote: ... The gradient was centrifuged at 4 °C and 100,000 ˗ g for 18 h (Optima L-80 XP Ultracentrifuge with Swing Rotor (Beckman Coulter)) ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Immunology 2023Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Neuroscience 2023Quote: ... and samples were centrifuged at 24,000 rpm at 4°C for 1h in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). After discarding the supernatant ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Cell Biology 2024Quote: ... The step gradients were centrifuged for 5 h at 132.000 x g at 4 °C (SW60 Beckman and Coulter, # 335649). Subsequently ...
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Immunology 2023Quote: ... virus solutions were clarified of debris by centrifugation at 10,000 rpm at 4°C for 30 minutes in a chilled SW32Ti rotor (Beckman Coulter), followed by pelleting through a 30% cold sucrose solution at 25,000 rpm for 90 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... Medium was cleared from EVs by ultracentrifugation at 100,000 ×g for 18 h at 4°C in a LE-80 ultracentrifuge (Beckman Coulter) with a 60Ti rotor [13] ...
-
bioRxiv - Biochemistry 2023Quote: ... The diluted extract was then centrifuged at 31,200 rpm for 30 minutes at 4°C in a Type 70 Ti rotor (Beckman Coulter). The supernatant was filtered through a 0.45 µm syringe filter (Millex-GP PES membrane (Millipore SLHP033RS ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was centrifuged at 40,000 rpm for 60 min at 4°C (XPN-100 ultracentrifuge, Type 45 Ti rotor, Beckman, USA). The supernatant was filtered through a 0.45 μm filter (Pall ...
-
bioRxiv - Bioengineering 2023Quote: ... The final supernatant was centrifuged at 100,000g at 4°C for 70 min using an ultracentrifuge (Optima MAX-XP Tabletop Ultracentrifuge, Beckman Coulter). The pellet was either used immediately or stored dry at −80°C ...
-
bioRxiv - Biochemistry 2023Quote: ... and the mixtures were then layered under a 20-40% iodixanol discontinuous gradient before to be centrifuged at 260,000 x g for 16h at 4°C using an SW41 Ti rotor (Beckman Coulter). After spinning ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filtered supernatants were concentrated by ultracentrifugation at 22.000 rpm for 2h at 4°C with OptimaTM L-90K ultracentrifuge (Beckman Coulter) and stored at −80°C (never refrozen).
-
bioRxiv - Cell Biology 2023Quote: ... and pelleted at 100,000xg for 20 min at 4 °C using fixed angle rotor (TLA-100 rotor, Beckman Coulter, 349481) in a benchtop ultracentrifuge (OptimaTL ...
-
bioRxiv - Cell Biology 2023Quote: ... Equilibrated tubes were ultra-centrifuged at 100,000xg for 1h at 4°C using a swinging-bucket rotor (SW 32Ti, Beckman Coulter, 369650; Optima XE, Beckman Coulter). Phagosome-containing beads float at the interface between the 10% and 25% layers ...
-
bioRxiv - Biophysics 2023Quote: ... The lysate was clarified by centrifugation at 40,000 rpm for 35 min at 4°C (Type 45 Ti Rotor, Beckman Coulter). The resulting supernatant was mixed with 1ml pre-washed IgG Sepharose 6 FastFlow beads (Cytiva ...
-
bioRxiv - Biophysics 2023Quote: ... Centrifugation was performed at 154,300 × g for 24 h at 4◦C (SW 41 Ti swinging-bucket rotor, Beckman Coulter). The separated bands were collected dropwise from the bottom of the tube ...
-
bioRxiv - Biochemistry 2024Quote: ... The homogenate was clarified by centrifugation for 30 min at 70,560 × g at 4°C in an Optima XPN Ultracentrifuge (Beckman Coulter) using a Ti-45 rotor ...
-
bioRxiv - Microbiology 2022Quote: ... clarified using 0.2 µm filter and pelleted at 54,000 rpm (180,000 ×g) for 2 hours at 4 °C in a TLA-55 rotor in an Optima Max-XP tabletop ultracentrifuge (Beckman). The supernatant was removed ...
-
bioRxiv - Biochemistry 2022Quote: ... A soluble fraction was obtained after centrifugation of the lysate at 19,000 rpm for 40 min at 4 °C performed using Avanti J-E with a rotor JA-20 (BECKMAN COULTER) to remove insoluble debris.
-
Dynamic states of eIF6 and SDS variants modulate interactions with uL14 of the 60S ribosomal subunitbioRxiv - Biochemistry 2022Quote: ... Ribosomes were pelleted by centrifugation at 63,000g for 16–19 hrs at 4°C using a Type 80 Ti rotor (Beckman Coulter). For all ultracentrifugation steps indicated here ...
-
Dynamic states of eIF6 and SDS variants modulate interactions with uL14 of the 60S ribosomal subunitbioRxiv - Biochemistry 2022Quote: ... were pelleted by centrifugation at 63,000g for 20 hrs at 4°C in a Type 80 Ti rotor (Beckman Coulter) as described above ...
-
bioRxiv - Cell Biology 2022Quote: ... OptiPrep step-gradient and centrifuged for 60 min at 19,210 × g at 4 °C in a TLS-55 rotor (Beckman Coulter). The ROS band was collected with a 18G needle ...
-
bioRxiv - Cell Biology 2022Quote: ... The lysate was dounced for 10 strokes on ice and cleared via centrifugation at 80K rpm for 10 minutes at 4°C using a TLA 110 rotor (Beckman) in a tabletop Beckm an ultracentrifuge ...
-
bioRxiv - Microbiology 2022Quote: ... purified by ultracentrifugation through a sucrose cushion (25% weight/volume in Tris-NaCl-EDTA buffer) for 75 min at 4°C and 28,000 rpm using a SW 32 TI rotor (Beckman Coulter), resuspended in serum-free DMEM medium and stored in small aliquots at −80°C ...
-
bioRxiv - Microbiology 2022Quote: ... Pseudotypes and VLPs were then concentrated by ultracentrifugation (20,000 RPM, 4 ºC, 1.5h, Beckman Coulter Optima XPN-100, SW32Ti rotor) through a 20% (w/v ...
-
bioRxiv - Microbiology 2022Quote: ... at 20 KPSI at 4°C and then centrifuged at 19 000 RPM in a JA-25.50 rotor (Beckman Coulter) for 30 minutes at 4°C ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by ultracentrifugation at 100,000 x g for 60 minutes at 4°C (SW 41 Ti Rotor, Beckman Coulter Inc). For size-exclusion chromatography (SEC ...
-
bioRxiv - Neuroscience 2023Quote: ... The gradients were centrifuged for 18 h at 100,000 xg at 4 °C in a SW 40 rotor (Beckman Coulter). 500 µl fractions were collected from the top of the ultracentrifuge tubes and analyzed by WB analysis.
-
bioRxiv - Cell Biology 2022Quote: ... Lysates were cleared by centrifugation for 30 min at 4°C at 18,000 rpm (SS-34 rotor; Beckman-Coulter, USA).
-
bioRxiv - Cell Biology 2023Quote: ... down to 6 ml and ultracentrifuged at 10,000xg for 16 min at 4°C in MLA-80 rotor (Beckman Coulter). The pellet was resuspended and washed with PBS at the same conditions (volume ...
-
Comparative membrane proteomics reveals diverse cell regulators concentrated at the nuclear envelopebioRxiv - Cell Biology 2023Quote: ... The whole cell homogenate was layered on top of 2 ml shelf of 0.8 M sucrose in HB and centrifuged at 2000 rpm for 10 min at 4°C in a JS5.2 rotor (Beckman Coulter) to yield a low speed nuclear pellet and a postnuclear supernatant ...
-
bioRxiv - Bioengineering 2023Quote: ... The final supernatant was centrifuged at 100,000g at 4°C for 70 min using an ultracentrifuge (Optima MAX-XP Tabletop Ultracentrifuge, Beckman Coulter). The pellet was either used immediately or stored dry at −80°C.
-
bioRxiv - Biochemistry 2023Quote: ... The reaction mixture was applied onto the top of the gradient solution and was centrifuged at 41,000 rpm at 4 °C for 17 hrs using an SW41 Ti rotor (Beckman Coulter). The gradient was fractionated using a Piston Gradient Fractionator (BioComp) ...
-
bioRxiv - Cell Biology 2023Quote: ... and then centrifuged for 150 min at 39,000 rpm and 4°C in an Optima L-100XP Ultracentrifuge (Beckman-Coulter) using a SW41Ti rotor ...
-
bioRxiv - Cancer Biology 2023Quote: ... Virus particles were collected by centrifugation at 32,000rpm for 2 hours at 4°C using the Optima XE-90 ultracentrifuge (Beckman Coulter). Virus was aliquoted and stored at -80°C until further use ...
-
bioRxiv - Biophysics 2023Quote: ... at 4°C until equilibrium was reached using an An Ti 60 rotor in an XL-I analytical ultracentrifuge (Beckman), run using ProteomeLab XL-A/XL-I (version 6.2) ...
-
bioRxiv - Plant Biology 2024Quote: ... and centrifuged at 10,000 x g for 30 min at 4°C using a TLA100.3 fixed angle rotor and an Optima TLX Ultracentrifuge (Beckman Coulter).
-
bioRxiv - Microbiology 2024Quote: ... sucrose gradients prepared with buffer C and centrifuged for 16 h at 71,935 g at 4 °C in a SW28 rotor (Beckman Coulter). Gradients were fractionated on a Biocomp Piston Gradient Fractionator (BioComp Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... The discontinuous sucrose gradient was centrifuged at 242,000 g for 47 min at 4 °C in a vertical rotor (VTi50 rotor, Beckman Coulter). The bulk GC fraction (GCF ...
-
bioRxiv - Microbiology 2024Quote: ... Samples were added to the top of a 60%-30%-10% sucrose/PBS gradient and centrifuged at 16,000 x g for 4.5 h at 4°C with an SW32 Ti rotor (Beckman, Brea, CA). Virus bands at the 60%-30% sucrose interface were collected via tube side puncture ...
-
bioRxiv - Microbiology 2024Quote: ... tepidum culture was centrifuged at 10,000 x g for 10 min at 4°C in a JA-14 rotor (Beckman Coulter), and the supernatant was centrifuged again at 12,000 x g to remove cells and large debris ...
-
bioRxiv - Microbiology 2024Quote: ... The pellets from different centrifuge tubes were pooled and resuspended in 1 mL of 1X PBS and pelleted again by ultracentrifugation at 165,700 x g for 2 h at 4°C in a TLA-55 rotor (Beckman Coulter). The pellet was resuspended in 500 µL of 1X PBS and stored at -20°C until use ...
-
bioRxiv - Microbiology 2024Quote: ... passed through 0.45 µm filters and concentrated on a 20% sucrose cushion (24,000 rpm at 4 °C for 2 h with a SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Microbiology 2024Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...