bioRxiv - Cell Biology 2021Quote: ... then finally at 100,000 g for 4 h at 4 ℃ using an SW28 rotor (Beckman Coulter, Fullerton, CA, USA). The pelleted exosomes were collected then subsequently resuspended in PBS ...
-
bioRxiv - Cell Biology 2021Quote: ... Hettich) at 4°C and then centrifuged at 40000 rpm for 4h30 at 4°C using SW41Ti rotor (Beckman). The supernatant was then UV inactivated at a wavelength of 254 nm for 4 min (3 times ...
-
bioRxiv - Microbiology 2023Quote: ... The lysates containing matured PsVs were loaded on an OptiPrep gradient that had been stabilized at least 1 h and centrifuged at 50k x g for 3.5-4 h at 4°C in a SW-55Ti rotor (Beckman). Fractions were collected in siliconized tubes and subjected to SDS-PAGE followed by Coomassie blue staining to assess the abundance of L1 and L2 proteins ...
-
bioRxiv - Microbiology 2024Quote: ... The lysates containing matured PsVs were loaded on an OptiPrep gradient that had been stabilized at least 1 h and centrifuged at 50k ×g for 3.5-4 h at 4°C in a SW-55Ti rotor (Beckman). Fractions were collected in siliconized tubes and subjected to SDS-PAGE followed by Coomassie blue staining to assess the abundance of L1 and L2 proteins ...
-
bioRxiv - Genetics 2024Quote: ... and spun at 70,000 rpm for 4 hours at 4°C using a TLA 100.3 Rotor in an Optima Ultracentrifuge (Beckman, 361889). After centrifugation ...
-
bioRxiv - Microbiology 2024Quote: ... and the remainder was then loaded onto a 20%-60% sucrose cushion and centrifuged at 25,000 rpm at 4°C for another 4 hours using the SW41 rotor (Beckman). The initial 5 μL sample and each sucrose gradient layer were then absorbed ...
-
bioRxiv - Cancer Biology 2022Quote: ... was removed using right-side size selection with AMPure XP beads at a 1:1 and 7:1 bead:sample ratio (Beckman Coulter) described previously26 ...
-
bioRxiv - Genomics 2020Quote: ... PCR was performed (7 cycles) with standard Illumina paired-end primers and the amplicons were then purified with AMPure XP beads (Beckman). The length ...
-
bioRxiv - Immunology 2023Quote: Flow cytometry analysis was performed at the end of the 7 day T cell progenitor differentiation stage using a CytoFLEX LX cytometer (Beckman), and data were compensated using single-stained controls in CytExpert v2.3 ...
-
bioRxiv - Biophysics 2024Quote: ... polarity-marked microtubules were pelleted at 20,000 g for 7 min at 37 °C in the TLA100 rotor (Beckman Coulter) and resuspended in BRB80 buffer with 40 mM taxol.
-
bioRxiv - Biochemistry 2024Quote: ... Digested lysates were run through 7% - 47% sucrose gradients using a Beckman Coulter ultracentrifuge and SW41 Ti rotor (Beckman Coulter) with 36,000 rpm at 4°C for 2 h ...
-
bioRxiv - Plant Biology 2024Quote: ... 400 μL of the extract were loaded on the top of a 7-47 % sucrose gradient and centrifuged in a SW41 rotor (Beckman) for 3h at 38 000 rpm at 4°C ...
-
bioRxiv - Biochemistry 2020Quote: ... which were centrifuged at 50,000rpm for 4 hours at 4°C using a TLS55 rotor and an Optima MAX-XP Ultracentrifuge (Beckman Coulter). The sample was physically fractionated into 10 fractions of 85 uL each ...
-
bioRxiv - Molecular Biology 2022Quote: ... 800 µl of EDTA-treated lysate was layered on top of the sucrose gradient and ultracentrifuged at 35000 rpm for 4 hours at 4 °C in a SW41Ti rotor (Beckman). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... all CCMV CP preparations were purified two times using an ultracentrifuge and 30% sucrose cushion – first with additional 0.5% Triton X-100 and the second time without Triton X-100 (4 h, 50 000 rmp, 4°C; Type 70Ti rotor, Beckman) and the pellet was then dissolved in buffer A ...
-
bioRxiv - Cell Biology 2022Quote: ... 4–40% sucrose gradient prepared in lysis buffer and centrifuged at 150,000 × g for 4 or 16 h at 4°C in a MLS-50 rotor (Beckman Coulter). Thereafter ...
-
bioRxiv - Neuroscience 2023Quote: ... the samples were filtered with a membrane pore size of 0.2 μm and centrifuged at 120,000 × g for 4 h at 4 °C in polycarbonate bottle assemblies (Beckman coulter, 355603) in a 70.1 Ti fixed angle rotor (Beckman coulter ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C in a TLA 100.3 rotor (Beckman). P13 ...
-
bioRxiv - Cell Biology 2022Quote: ... 4°C (Type 45 Ti rotor, Beckman Coulter) for 30 min to collect supernatant ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 °C (Beckman Coulter Optima LE-80K Ultracentrifuge). The clarified lysate was placed in a beaker on a stir plate at 4 °C and concentrated ammonium sulfate (5 mM HEPES pH 7.5 ...
-
bioRxiv - Neuroscience 2020Quote: ... for 4 h with SW28 rotor (Beckman Coulter). The concentrated vector was stored at −80 °C until use ...
-
bioRxiv - Biochemistry 2022Quote: ... 4 °C on a Sorvall WX90 ultracentrifuge (Beckman) with SW55Ti rotor ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4°C in SW-41Ti rotor (Beckman Coulter). Subsequently ...
-
bioRxiv - Plant Biology 2021Quote: ... 4 °C for 18 h (Beckman SW41 rotor). The sugar solution contains 0.65 M sucrose ...
-
bioRxiv - Biochemistry 2022Quote: ... 4°C using a SW41Ti rotor (Beckman Coulter). A BioComp fractionator was used to collect fractions 1 – 16 ...
-
bioRxiv - Neuroscience 2022Quote: ... at 4°C in a Beckman ultracentrifuge (Beckman). After centrifugation ...
-
bioRxiv - Systems Biology 2022Quote: A particle size analyzer (Multisizer 4, Beckman Coulter) was used to count the number of cells ...
-
bioRxiv - Microbiology 2024Quote: ... 4 °C (Beckman Coulter, JA 25-50 rotor) for 10 min ...
-
bioRxiv - Microbiology 2024Quote: ... 4°C (Beckman Coulter, JA 25-50 rotor) for 10 min and the cell lysates were incubated with 1 mL of prewashed Ni-NTA Agarose beads (QIAGEN ...
-
bioRxiv - Genomics 2024Quote: ... 4°C for 1:30h (Beckman Coulter SW32Ti). The pellet was ultimately resuspended with StemSpanTM SFEM-II media (Stemcell Technologies ...
-
bioRxiv - Neuroscience 2021Quote: ... 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge; Beckman Coulter, Fullerton, CA) for 30 min ...
-
bioRxiv - Immunology 2021Quote: ... were incubated with monoclonal antibodies at 4°C for 30 min and then fixed with 4% paraformaldehyde before analysis on a Cytoflex cytometer (Beckman Coulter). Data were analyzed by Flow Jo software v.10.7 (BD Biosciences) ...
-
bioRxiv - Cell Biology 2021Quote: ... and loaded onto of a step-wise sucrose gradient as described by the manufacturer and subjected to ultracentrifugation at 150,000 xg for 4 h at 4 °C using SW50.1 rotor (Beckman Coulter, Mississauga, ON). Fractions were then collected and subject to denaturation with Laemmli buffer until further use.
-
bioRxiv - Neuroscience 2023Quote: ... The resulting supernatant was filtered with a membrane pore size of 0.2 μm (Whatman) and centrifuged at 120,000 × g for 4 h at 4 °C in polycarbonate bottle assemblies (Beckman coulter, 355603) in a 70.1 Ti fixed angle rotor (Beckman coulter ...
-
bioRxiv - Molecular Biology 2024Quote: ... They were cherrypicked from the original library plates and 4 crRNAs per target were pooled (4 x10 μl) and re-arrayed using a Biomek-FX automated pipetting system (Beckman Coulter). Edit-R CRISPR-Cas9 Synthetic tracrRNA (Horizon Discovery Biosciences ...
-
bioRxiv - Cell Biology 2020Quote: ... with anti-Met-PE (clone eBioclone 7, eBiosciences) or isotype control (clone eBRG1, eBiosciences) or permeabilized (IntraPrep Permeabilization kit, Beckman Coulter) before staining (total Met) ...
-
bioRxiv - Genomics 2023Quote: ... Five million cells were harvested at 315xg for 7 minutes in a 15 mL centrifuge tube (Beckman Coulter Allegra X-14R) and stored at -80°C ...
-
bioRxiv - Biochemistry 2024Quote: ... This extract was then carefully layered onto a 7% to 47% linear sucrose gradient and subjected to centrifugation in a SW41Ti rotor (Beckman Coulter) at 36,000 rpm for 2 h at 4°C ...
-
bioRxiv - Cell Biology 2024Quote: ... 96-well plates were incubated at the permissive temperature (15°C) for 7 days and then replicated with a Biomek FX (Beckman Coulter). These replica plates were incubated at the non-permissive temperature (25°C ...
-
bioRxiv - Bioengineering 2024Quote: Frozen TGFb1/ET1-treated and untreated hvCTS (n=7 per condition) and hvCOC (n=5 per condition) were lysed using Agencourt RNAdvance Tissue kit (Beckman Coulter) lysis buffer and homogenized at 1000 rpm for 2 min with 5 mm Stainless Steel Beads (Qiagen ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was filtered by 0.22 μm nylon membrane followed by centrifugation through a cushion of 50 % (w/v) sucrose with 36,000 rpm at 4 °C for 4 h (Beckman SW41 Ti rotor). The pellet was resuspended with PBS and the copy number of DWV was quantified by qRT-PCR.
-
bioRxiv - Biophysics 2024Quote: ... The gradients were then centrifuged at 187,000 × g for 4 h at 4°C in a SW 41 Ti rotor (Beckman Coulter, Brea, CA). Bands corresponding to purified virus particles (∼1.36 g/mL ...
-
bioRxiv - Microbiology 2020Quote: ... 4°C in SW 60 Ti rotor (Beckman Coulter) to pellet cyanophage particles ...
-
bioRxiv - Immunology 2021Quote: ... CD38 APC-AF700 (clone LS198-4-3; Beckman Coulter), CD19 APC-Cy7 (clone SJ25C1 ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C (SW32Ti rotor, Optima L-80XP ultracentrifuge, Beckman) with the maximum acceleration and minimum deceleration ...
-
bioRxiv - Biochemistry 2021Quote: ... 4°C in swinging-bucket rotor SW40 (Beckman Coulter). Fractions (1 ml ...
-
bioRxiv - Microbiology 2022Quote: ... at 4°C cells were resuspended in Isoflow (Beckman) for further reading the percentage of fluorescent labelled cells on the cytometer (FC500 ...
-
bioRxiv - Microbiology 2022Quote: ... 4 °C (SW41 Ti Swinging-Bucket rotor, Beckman & Coulter). Bands containing virus particles were extracted with a syringe ...
-
bioRxiv - Biochemistry 2023Quote: ... counted using a coulter counter (Beckman Coulter, Multisizer 4) and seeded onto 24-well dishes (Nunc ...
-
bioRxiv - Cell Biology 2024Quote: ... at 4°C in a Ti70 rotor (Beckman Coulter). Clarified lysates were loaded using a sample pump or super-loop (Cytiva ...