Labshake search
Citations for Beckman :
601 - 650 of 1264 citations for 7 Chloromethyl 5H 1 3 thiazolo 3 2 a pyrimidin 5 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... Concentrated supernatants were then subjected to ultracentrifugation at 160,000 x g for 2 hours at 4°C using a Beckman Ti 45 rotor (Beckman, Germany). Supernatants were completely removed and the pellet containing the crude MV fraction was resuspended in 400 μL of chilled PBS ...
-
bioRxiv - Neuroscience 2022Quote: ... The gradient was subjected to high-speed centrifugation at 100,000 x g for 2 h at 4° C using a SW41Ti rotor (Beckman Coulter). 12 fractions of 1ml each were collected from the top of the gradient ...
-
bioRxiv - Neuroscience 2022Quote: ... Lentiviral supernatant was collected 48 hours after transfection and centrifuged for 2 hours by ultracentrifugation at 25,000 RPM at 4°C (Beckman Coulter). Pellets were resuspended in DPBS and frozen in -80°C until used ...
-
bioRxiv - Neuroscience 2022Quote: ... new medium was added for another round of production and supernatant was filtered (0.45 μm filter) and centrifuged for 2 hours at 19400 rpm (SW28 Beckman rotor). The pellets were suspended in phosphate buffer saline (PBS) ...
-
bioRxiv - Microbiology 2022Quote: ... was added before ultracentrifugation at 20,000 × g for 2 hours at 10°C in an Optima L-90K Ultracentrifuge with the SW32Ti rotor (Beckman Coulter). Supernatants were carefully discarded by aspiration and the 6 phage pellets were resuspended with 0.1 ml of TM buffer (50 mM Tris-HCl ...
-
bioRxiv - Synthetic Biology 2021Quote: Reactions were assembled in a final volume of 2 μL using a Labcyte Echo® 550 (Beckman Coulter, Brea, CA) via a two-step strategy ...
-
bioRxiv - Neuroscience 2021Quote: ... The resulting homogenate was mixed with 6 mL sucrose (2 mol/L) and 2.5 mL CaCl2 (0.1 mmol/L) in an ultra-clear centrifuge tube (#344059, Beckman Coulter, USA). Then ...
-
bioRxiv - Molecular Biology 2021Quote: ... cell lysates were cleared by centrifugation at 4 °C for 5 minutes at 16000 x g and loaded onto ice-cold 15-50 % sucrose-CHX gradients and ultracentrifuged at 4 °C for 2 hours at 274 000 x g in a SW-41Ti rotor (Beckman). Gradients were fractionated and monitored at an absorbance of 254 nm with a fraction collector (BioComp Instruments ...
-
bioRxiv - Cancer Biology 2021Quote: ... Samples were ultracentrifugated at 100,000g for 2 hours using OPTIMA MAX XP ULTRACENTRIFUGE with MLA-130 fixed-angle rotor (Beckman-Coulter) and pellets were resuspended in 0.22 μm-filtered PBS ...
-
bioRxiv - Microbiology 2021Quote: ... 2 ml of each sucrose concentration was layered from 70% to 25% in open-top ultracentrifuge tubes (Beckman Coulter, 344059) immediately before use ...
-
bioRxiv - Neuroscience 2019Quote: ... The supernatant was layered onto a 20% sucrose cushion prepared in the same lysis buffer and then centrifuged at 186,000 x g for 2 h at 4 °C in a TLA-55 rotor ultracentrifuge (Beckman Coulter). RNA was isolated from the ribosome-enriched pellet using TRIzol LS reagent according to manufacturer’s instructions (Invitrogen).
-
bioRxiv - Molecular Biology 2020Quote: ... Centrifugation was conducted at 40,000 rpm for 2 hours at 4°C in a SW-41 Ti rotor (Beckman Coulter), and fractions were collected from the top of the gradient (#1 to #20) ...
-
bioRxiv - Biochemistry 2020Quote: ... Protein-liposome complexes were separated from unbound protein by centrifugation (2 h at 45.000 rpm, 4 °C, MLS50 rotor -Beckman Coulter) in the density gradient ...
-
bioRxiv - Biochemistry 2021Quote: ... The depleted fraction was collected by gentle centrifugation (100 rcf for 2 min) into a clean 96 well plate (Beckman Coulter ...
-
bioRxiv - Microbiology 2022Quote: ... clarified using 0.2 µm filter and pelleted at 54,000 rpm (180,000 ×g) for 2 hours at 4 °C in a TLA-55 rotor in an Optima Max-XP tabletop ultracentrifuge (Beckman). The supernatant was removed ...
-
bioRxiv - Bioengineering 2022Quote: ... the conditioned media was subjected to an additional centrifugation step of 118,000 × g for 2 h in a Type 70 Ti ultracentrifuge rotor (Beckman Coulter). The resulting EV pellet was resuspended in 1X PBS and placed into a Nanosep 300 kDa MWCO spin column (Pall ...
-
bioRxiv - Cell Biology 2022Quote: ... the virus-cell mixture was centrifuged at 1,000 rcf for 2 hours at 32°C (Beckman Coulter, Allegra X-30R). Infected cells were then cultured as described above and subsequently FACS-sorted for the establishment of clonal cell lines.
-
bioRxiv - Immunology 2022Quote: ... eVLPs were purified by ultracentrifugation at 50,000 rpm (135,000 x g) for 2 hours at 4°C using a TLA100.3 rotor and a OptimaTM TLX ultracentrifuge (Beckman Coulter) on a 20% w/v sucrose cushion ...
-
bioRxiv - Neuroscience 2023Quote: ... The top 11 mL and the bottom 2 mL of the gradient were transferred to separate 60 mL 45Ti ultracentrifuge tubes (Beckman), topped up with PBS and centrifuged at 100,000 x g for 70 min at 4°C ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was ultracentrifuged at 100,000 ×g at 4 °C for 2 h using an Optima XE-90 (Beckman Coulter) to collect EMVs ...
-
bioRxiv - Cell Biology 2023Quote: ... Each fraction was subjected to a washing step in ice-cold PBS at 100,000 × g at 4°C for 2 h using a SW28Ti rotor (Beckman Coulter). The pelleted EVs were resuspended in ice-cold PBS ...
-
bioRxiv - Physiology 2023Quote: ... Samples were ultracentrifuged at 100,000 rpm at 16°C for 2 hours (rotor: Beckman TLA-100; Centrifuge: Beckman Optima TLX). 100ul from the top of the tube was collected as VLDL fraction ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filtered supernatants were concentrated by ultracentrifugation at 22,000 rpm for 2 hours at 4°C with OptimaTM L-90K Ultracentrifuge (Beckman Coulter) and stored at -80°C (never refrozen).
-
bioRxiv - Biophysics 2023Quote: ... the supernatant of cell lysates was centrifuged to isolate the total membrane fraction at 24,000 rpm for 2 h in the 45Ti rotor using ultracentrifuge (Beckman-Coulter). Membrane resuspension in 50 mM Tris-HCl buffer (pH 8.0 ...
-
bioRxiv - Cell Biology 2023Quote: ... The supernatant was then overlaid onto a 2 ml 60% iodixanol cushion and spun at 100,000 x g (SW32 rotor, Beckman Coulter) for 18h ...
-
bioRxiv - Neuroscience 2023Quote: ... This supernatant was next subjected to ultracentrifugation at 120,000 x g for 2 h at 4LJ in a SW 41 Ti Rotor Swinging-Bucket rotor (Beckman Coulter), and the pellets collected as small factors like exosome ...
-
bioRxiv - Plant Biology 2023Quote: ... The resulting solution was then centrifuged again at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was decanted ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was then decanted and discarded ...
-
bioRxiv - Microbiology 2023Quote: ... resuspended in 200 µl 2% PBS-BSA and analyzed for mean fluorescence intensity (MFI) of ACE2 expression with CytoFLEX flow cytometer (Beckman). To determine the biological effects of the purinergic receptor P2X7 and NLRP3 inflammasome on viral entry ...
-
bioRxiv - Biophysics 2023Quote: ... followed by layering the cleared lysate onto 40 mL of 2 M sucrose cushion and ultracentrifugation in Ti-45 rotor (Beckman) at 42,000 rpm for 2 hours ...
-
bioRxiv - Neuroscience 2023Quote: ... Fraction LP2 was obtained after centrifugation of fraction LS1 for 2 h at 165,000 g in a SW40 Ti rotor (Beckman, US). Corresponding supernatant was collected as Fraction LS2 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Virus particles were collected by centrifugation at 32,000rpm for 2 hours at 4°C using the Optima XE-90 ultracentrifuge (Beckman Coulter). Virus was aliquoted and stored at -80°C until further use ...
-
bioRxiv - Plant Biology 2023Quote: ... and water to a final volume of either 2 μL for the acoustic liquid handling robot (Labcyte Echo 550, Beckman) or 5 μL for manual handling ...
-
bioRxiv - Cancer Biology 2023Quote: ... The gradients were ultracentrifuged at 35,000 rpm for 2 hrs at 4°C using an SW41 Ti rotor (Beckman Coulter). The gradients were then displaced into a UA-6 continuous UV detector (Teledyne ISCO ...
-
bioRxiv - Immunology 2023Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Immunology 2023Quote: The SARS-CoV-2 lentiviral pseudotyped neutralization assays were performed on integrated automation platforms consisting of a Biomek liquid handler from Beckman Coulter ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were ultracentrifuged at 4 °C and 150,000 ˗ g for 2 h (Optima L-80 XP Ultracentrifuge with Type 70.1 Ti Fixed-Angle Titanium Rotor (Beckman Coulter)) and supernatants were removed ...
-
bioRxiv - Cell Biology 2024Quote: ... Gradients were centrifuged at 36,000 rpm for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Following centrifugation ...
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Genomics 2021Quote: ... The spores were washed twice with sterile ddH2O and pelleted at 3700g for 5 min at 4 °C in an Allegra X-12R centrifuge (Beckman, Brea, CA, USA). Spores were resuspended in sterile ddH2O and kept at 4°C until experiments.
-
bioRxiv - Biophysics 2021Quote: ... Different ratios of LUVs and cyt c (with the protein concentration kept at 5 μM) were incubated in the sample buffer at room temperature for 15 min in ultracentrifugal tubes (Beckman Coulter, Indianapolis, IN). The effective PG/cyt c molar ratio (R ...
-
bioRxiv - Cell Biology 2019Quote: ... The mix was then airfuged 5 min at 30 psi with an Airfugee® Air-driven ultracentrifuge (Beckman Coulter Inc., Brea, California, USA) and the pellet was re-suspended in 80% of the initial volume and left on ice for 20 min to depolymerize the microtubules ...
-
bioRxiv - Immunology 2021Quote: ... Supernatants were collected and centrifuged for 5 min at 1200 rpm at 20°C (Allegra™ X-12R Centrifuge, Beckman Coulter, the Netherlands). Cells were then resuspended in PBS ...
-
bioRxiv - Cancer Biology 2022Quote: ... cells were pelleted and washed twice before resuspension in 500μL of cold PBS for analysis using flow cytometry (CytoFLEX 5, Beckman Coulter, Mississauga, ON, Canada) wherein mean fluorescence intensity of the gated cells (10,000 events ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... We pooled 1.5 µl of each indexed library (including blanks and museum controls) and performed size selection with AMPure XP beads (Beckman Coulter, IN, USA) for fragments of approximately 100-500 bp in length ...
-
bioRxiv - Microbiology 2022Quote: ... then clarified by centrifugation at 2000 rpm at 4°C for 5 min in a refrigerated tabletop centrifuge (Beckman Coulter, Indianapolis IN, USA) to remove large debris ...
-
bioRxiv - Cell Biology 2021Quote: 1 mL samples of culture were diluted 1:100 diluted with Isoton II Diluent (Beckman Coulter) and used to determine cell concentration of the culture using a Beckman Multisizer 3 Coulter Counter ...
-
bioRxiv - Genomics 2022Quote: ... The DNA fragments were purified by Ampure XP beads (volume ratio 1:1, Beckman Coulter, #A63881) and elute the DNA fragments in 27 µL water ...