Labshake search
Citations for Beckman :
501 - 550 of 1143 citations for 6 Chloro 1 2 dihydro 3H indazol 3 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... The depleted fraction was collected by gentle centrifugation (100 rcf for 2 min) into a clean 96 well plate (Beckman Coulter ...
-
bioRxiv - Microbiology 2022Quote: ... clarified using 0.2 µm filter and pelleted at 54,000 rpm (180,000 ×g) for 2 hours at 4 °C in a TLA-55 rotor in an Optima Max-XP tabletop ultracentrifuge (Beckman). The supernatant was removed ...
-
bioRxiv - Bioengineering 2022Quote: ... the conditioned media was subjected to an additional centrifugation step of 118,000 × g for 2 h in a Type 70 Ti ultracentrifuge rotor (Beckman Coulter). The resulting EV pellet was resuspended in 1X PBS and placed into a Nanosep 300 kDa MWCO spin column (Pall ...
-
bioRxiv - Cell Biology 2022Quote: ... the virus-cell mixture was centrifuged at 1,000 rcf for 2 hours at 32°C (Beckman Coulter, Allegra X-30R). Infected cells were then cultured as described above and subsequently FACS-sorted for the establishment of clonal cell lines.
-
bioRxiv - Cell Biology 2023Quote: ... Each fraction was subjected to a washing step in ice-cold PBS at 100,000 × g at 4°C for 2 h using a SW28Ti rotor (Beckman Coulter). The pelleted EVs were resuspended in ice-cold PBS ...
-
bioRxiv - Immunology 2022Quote: ... eVLPs were purified by ultracentrifugation at 50,000 rpm (135,000 x g) for 2 hours at 4°C using a TLA100.3 rotor and a OptimaTM TLX ultracentrifuge (Beckman Coulter) on a 20% w/v sucrose cushion ...
-
bioRxiv - Neuroscience 2023Quote: ... The top 11 mL and the bottom 2 mL of the gradient were transferred to separate 60 mL 45Ti ultracentrifuge tubes (Beckman), topped up with PBS and centrifuged at 100,000 x g for 70 min at 4°C ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was ultracentrifuged at 100,000 ×g at 4 °C for 2 h using an Optima XE-90 (Beckman Coulter) to collect EMVs ...
-
bioRxiv - Cell Biology 2023Quote: ... 5 mM Mg(OAc)2) and centrifuged for 20 min at 100,000 x g in a 70Ti rotor (Beckman Coulter). The resulting membrane pellet was resuspended in 1 ml rough microsome (RM ...
-
bioRxiv - Plant Biology 2023Quote: ... and water to a final volume of either 2 μL for the acoustic liquid handling robot (Labcyte Echo 550, Beckman) or 5 μL for manual handling ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filtered supernatants were concentrated by ultracentrifugation at 22,000 rpm for 2 hours at 4°C with OptimaTM L-90K Ultracentrifuge (Beckman Coulter) and stored at -80°C (never refrozen).
-
bioRxiv - Biophysics 2023Quote: ... the supernatant of cell lysates was centrifuged to isolate the total membrane fraction at 24,000 rpm for 2 h in the 45Ti rotor using ultracentrifuge (Beckman-Coulter). Membrane resuspension in 50 mM Tris-HCl buffer (pH 8.0 ...
-
bioRxiv - Cell Biology 2023Quote: ... The supernatant was then overlaid onto a 2 ml 60% iodixanol cushion and spun at 100,000 x g (SW32 rotor, Beckman Coulter) for 18h ...
-
bioRxiv - Neuroscience 2023Quote: ... This supernatant was next subjected to ultracentrifugation at 120,000 x g for 2 h at 4LJ in a SW 41 Ti Rotor Swinging-Bucket rotor (Beckman Coulter), and the pellets collected as small factors like exosome ...
-
bioRxiv - Physiology 2023Quote: ... Samples were ultracentrifuged at 100,000 rpm at 16°C for 2 hours (rotor: Beckman TLA-100; Centrifuge: Beckman Optima TLX). 100ul from the top of the tube was collected as VLDL fraction ...
-
bioRxiv - Plant Biology 2023Quote: ... The resulting solution was then centrifuged again at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was decanted ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was then decanted and discarded ...
-
bioRxiv - Microbiology 2023Quote: ... resuspended in 200 µl 2% PBS-BSA and analyzed for mean fluorescence intensity (MFI) of ACE2 expression with CytoFLEX flow cytometer (Beckman). To determine the biological effects of the purinergic receptor P2X7 and NLRP3 inflammasome on viral entry ...
-
bioRxiv - Biophysics 2023Quote: ... followed by layering the cleared lysate onto 40 mL of 2 M sucrose cushion and ultracentrifugation in Ti-45 rotor (Beckman) at 42,000 rpm for 2 hours ...
-
bioRxiv - Neuroscience 2023Quote: ... Fraction LP2 was obtained after centrifugation of fraction LS1 for 2 h at 165,000 g in a SW40 Ti rotor (Beckman, US). Corresponding supernatant was collected as Fraction LS2 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Virus particles were collected by centrifugation at 32,000rpm for 2 hours at 4°C using the Optima XE-90 ultracentrifuge (Beckman Coulter). Virus was aliquoted and stored at -80°C until further use ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Immunology 2023Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Immunology 2023Quote: The SARS-CoV-2 lentiviral pseudotyped neutralization assays were performed on integrated automation platforms consisting of a Biomek liquid handler from Beckman Coulter ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were ultracentrifuged at 4 °C and 150,000 ˗ g for 2 h (Optima L-80 XP Ultracentrifuge with Type 70.1 Ti Fixed-Angle Titanium Rotor (Beckman Coulter)) and supernatants were removed ...
-
bioRxiv - Cancer Biology 2023Quote: ... The gradients were ultracentrifuged at 35,000 rpm for 2 hrs at 4°C using an SW41 Ti rotor (Beckman Coulter). The gradients were then displaced into a UA-6 continuous UV detector (Teledyne ISCO ...
-
bioRxiv - Cell Biology 2024Quote: ... Gradients were centrifuged at 36,000 rpm for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Following centrifugation ...
-
bioRxiv - Cell Biology 2021Quote: 1 mL samples of culture were diluted 1:100 diluted with Isoton II Diluent (Beckman Coulter) and used to determine cell concentration of the culture using a Beckman Multisizer 3 Coulter Counter ...
-
bioRxiv - Genomics 2022Quote: ... The DNA fragments were purified by Ampure XP beads (volume ratio 1:1, Beckman Coulter, #A63881) and elute the DNA fragments in 27 µL water ...
-
bioRxiv - Cancer Biology 2023Quote: ... Post-PCR clean-up was performed using 1:1 volume Ampure XP beads (Beckman Coulter A63880). Samples were dissolved in 10 mM Tris-HCl (pH 8 ...
-
bioRxiv - Biochemistry 2021Quote: ... 1 h 10 min (45Ti, Beckman), resuspended in lysis buffer and stored in aliquots at –80°C until use ...
-
bioRxiv - Bioengineering 2020Quote: ... 1X 1 μm SPRI beads (Beckman) in 1X PBS buffer with 0.5% Tween20 were injected into the thin-chip ...
-
bioRxiv - Cancer Biology 2020Quote: ... GlyA PE (1:100, Beckman Coulter), CD71 BV650 (1:100) ...
-
bioRxiv - Cancer Biology 2020Quote: ... GlyA PE (1:100, Beckman Coulter), CD71 BV650 (1:100) ...
-
bioRxiv - Cancer Biology 2020Quote: ... CD4 PC5 (1:100, Beckman Coulter) and CD56 BV605 (1:100) ...
-
bioRxiv - Cancer Biology 2020Quote: ... GlyA PE (1:100, Beckman Coulter), CD71 BV650 (1:100) ...
-
bioRxiv - Microbiology 2022Quote: ... or 1:300 KC57-RD1 (Beckman Coulter 6604667 in BD Perm/Wash Buffer for 30 minutes ...
-
bioRxiv - Immunology 2023Quote: ... CD56 (NKH-1-RD1, Beckman Coulter), ERK1/2 (T202/Y204 ...
-
bioRxiv - Cell Biology 2020Quote: ... thin-layer cell preparations for confocal microscopy of enriched small luteal cells and large luteal cells was performed using Cytofuge 2 (Beckman Counter). Cells were then fixed with 10% neutral buffered formalin at 4 °C for 30 min ...
-
Phenotypic and molecular evolution across 10,000 generations in laboratory budding yeast populationsbioRxiv - Evolutionary Biology 2020Quote: ... We combined the 8 wells from column 2 of each plate and used the pooled culture to measure cell density on a Coulter Counter Z2 (Beckman Coulter). We spotted the entire volume of each of the other 88 wells on CSM-Arg (Sunrise Scientific ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... using a Beckman Coulter TLA100 rotor at 70,000 rpm at 4 C for 2 hours in a 13 mm x 51 mm polycarbonate ultracentrifuge tube (Beckman Coulter 349622). The sucrose solution was removed from the tube ...
-
bioRxiv - Genomics 2020Quote: The ∼400 bp amplicon product produced using both Pool-1 and Pool-2 from the same clinical sample was combined and purified using a 1X concentration of Agencourt AMPure XP beads (Beckman Coulter); the final product was eluted in 30 µl of elution buffer (Qiagen ...
-
bioRxiv - Neuroscience 2019Quote: ... with 2 ml of a 20% sucrose in dPBS cushion and ultracentrifugated at 20,000 RPM (Beckman Coulter SW 32 Ti rotor) at 4°C for 2 hours ...
-
bioRxiv - Cell Biology 2019Quote: ... The culture was harvested in to 2 × 250 ml centrifuge bottles (Nalgene, 3120-0250) and centrifuged in an Optimia XPN-100 ultra centrifuge (Beckman Coulter) with a SW 32 Ti rotor at 5,000 × g for 20 min at 4 °C ...
-
bioRxiv - Cancer Biology 2020Quote: ... The donor-derived LT-HSC cell populations were sorted according to the gating strategy in Extended data Figure 2 using MoFlo Astrios Cell Sorter (Beckman Coulter). LT-HSC cells were directly sorted into 50μl RNA extraction buffer (ARCTURUS PicoPure RNA Isolation Kit (Applied Biosystems ...
-
bioRxiv - Microbiology 2022Quote: ... Washed pellets were resuspended in 2 mL 1x PBS and fluorescence was calculated using a LSR II cell analyzer (Beckman Coulter). Two biological replicates of 50,000 cell counts were analyzed with FlowJo ...
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Neuroscience 2020Quote: ... the homogenized solution was added onto a sucrose cushion (2 ml) in a 10 ml Ultra-Clear centrifuge tube (Beckman Coulter). Separation of nuclei from the tissue was done by centrifugation (26.500xg at 4°C for 1.5 h ...