Labshake search
Citations for Diagenode :
201 - 250 of 333 citations for DNA Polymerase since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genetics 2020Quote: ... Sequencing libraries were prepared with the immunoprecipitated DNA using the MicroPlex Library Preparation Kit v2 (Diagenode) with the KAPA HiFi polymerase (Kapa Biosystems ...
-
bioRxiv - Developmental Biology 2021Quote: The DNA libraries were prepared using the Microplex library preparation Kit V2 (Diagenode, Cat. No. C05010013) following the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2021Quote: ... The precipitated DNA was used to generate libraries with the MicroPlex Library Preparation kit v2 (Diagenode) for ChIP-seq according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2022Quote: ... Cells were lysed and DNA fragmented (∼500 bp) by sonication in a Bioruptor® Plus (Diagenode) for 48 × 30 s and 30 s cooling ...
-
bioRxiv - Systems Biology 2023Quote: ... single-stranded DNA mixture was incubated with 5-mC antibody provided by MagMeDIP-seq Package (Diagenode), followed by 14-16 cycles of library amplification ...
-
bioRxiv - Genomics 2023Quote: ... 13 ng of DNA was purified then sheared at 10 kb using the Megaruptor1 system (Diagenode). Using SMRTbell® gDNA Sample Amplification Kit ...
-
bioRxiv - Genomics 2023Quote: ... 12 μg of DNA was prepared for sequencing using Megaruptor 3 shearing (Diagenode, settings 19/31) and the Express Template Prep Kit v2 and SMRTbell Cleanup Kit v2 (PacBio) ...
-
bioRxiv - Microbiology 2023Quote: ... About 2 µg of genomic DNA was sheared by sonication with a Picoruptor (Diagenode, S.A., Belgium) instrument to a size of 300–400 bp in length ...
-
bioRxiv - Microbiology 2023Quote: ... 1 ug of genomic DNA was sheared by sonication using a Picorupter (Diagenode s.a., Liege, Belgium) to obtain fragments with an average size of 300 bp ...
-
bioRxiv - Genomics 2023Quote: ... Purified DNA was sonicated to an average size of 300–400 bp using a Bioruptor (Diagenode; eight cycles of 20 sec on and 60 sec off) ...
-
bioRxiv - Microbiology 2023Quote: ... Purification steps were performed using AMPure PB beads (PacBio).15 μg of DNA was purified then sheared at 20 kb using the Megaruptor1 system (Diagenode). Using SMRTbell Express Template prep kit 2.0 ...
-
bioRxiv - Genetics 2023Quote: ... Five hundred nanograms of genomic DNA was sheared using a Bioruptor UCD200 (Diagenode, Denville, NJ, USA), generating fragments ∼180 bp ...
-
bioRxiv - Molecular Biology 2024Quote: Genomic DNA was sheared to ∼400-500bp using a Bioruptor Pico Sonicator (Diagenode, Denville, NJ, USA), and used a HS D1000 ScreenTape run on a Tapestation 2200 (Agilent Technologies ...
-
bioRxiv - Genomics 2024Quote: ... DNA was then sheared to a target size of 30 kb on a Megaruptor3 instrument (Diagenode) with either the DNAFluid+ needles at speed 45 for two cycles (cell and brain ...
-
bioRxiv - Molecular Biology 2020Quote: ... Libraries were generated from 1 ng of DNA using the MicroPlex Library Preparation Kit v2 (C05010012, Diagenode) according to manufacturer’s instructions ...
-
bioRxiv - Genomics 2019Quote: ... 140 μg of DNA was purified and then sheared to 20 kb using the megaruptor system (Diagenode). For each library ...
-
bioRxiv - Genomics 2019Quote: ... 10 μg of DNA was purified and then sheared to 20 kb using the megaruptor system (Diagenode). For each library ...
-
bioRxiv - Cancer Biology 2021Quote: ... The DNA-protein-antibody complexes were captured by DiaMag protein A-coated magnetic beads (Diagenode; Cat#: C03010020) by incubating at 4 °C for 2 hours ...
-
bioRxiv - Cancer Biology 2021Quote: ... The DNA-protein-antibody complexes were captured by DiaMag protein A-coated magnetic beads (Diagenode; Cat#: C03010020) by incubating at 4 °C for 2 hours ...
-
bioRxiv - Plant Biology 2021Quote: ... De-crosslinking and subsequent DNA recovery steps were performed using the Ipure kit v2 (Diagenode, Liège, Belgium). The Ovation Ultralow Sytem V2 (NuGEN ...
-
bioRxiv - Genomics 2021Quote: ... Cross-linking was reversed at 65ºC overnight and immunoprecipitated DNA was recovered using the IPure Kit (Diagenode). Genomic regions of interest were identified by real-time PCR (qPCR ...
-
bioRxiv - Genomics 2022Quote: ... 10 μg of DNA was purified then sheared to 20 kb fragments using the megaruptor1 system (Diagenode). For this library ...
-
bioRxiv - Genomics 2022Quote: ... 90 μg of DNA was purified then sheared to 20 kb fragments using the megaruptor1 system (Diagenode). For each library ...
-
bioRxiv - Neuroscience 2021Quote: Sequencing libraries were generated from the purified DNA by MicroPlex Library Preparation Kit v1 x12 (Diagenode, C05010010) for tolerized samples or MicroPlex Library Preparation Kit v2 x12 (Diagenode ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... approximately 7 µg of DNA was sheared at 20 kb using the megaruptor system (Diagenode, Liege, Belgium). A DNA damage repair step was performed on 5 µg of DNA ...
-
bioRxiv - Developmental Biology 2019Quote: ... DNA was crosslinked in formaldehyde and sonicated in a Bioruptor for 15 minutes at high power (Diagenode). Cells were resuspended in a total volume of 250 ml of Buffer A and Buffer B mix (half of the recommended volume for 0.5×106cells) ...
-
bioRxiv - Immunology 2021Quote: ... DNA libraries for all 12 samples were prepared using the MicroPlex Library Preparation Kit (12 indexes; Diagenode) following the manufacturer’s recommendations ...
-
bioRxiv - Genomics 2020Quote: ... the DNA was sheared to between 15 kb and 23 kb using the Megaruptor® 3 (Diagenode). HiFi sequencing libraries were prepared28 using SMRTbell™ Express Template Prep Kit 2.0 and followed by immediate treatment with the Enzyme Clean Up Kit (PN ...
-
bioRxiv - Molecular Biology 2021Quote: ... DNA from this lysate was sheared to 300 bp fragments using a BioRuptor UCD-200 sonicator (Diagenode). Cell debris were removed by high-speed centrifugation and DNA from the supernatant was isolated by ethanol precipitation and resuspension in TE buffer ...
-
bioRxiv - Genetics 2020Quote: ... The DNA was sonicated for 2 cycles of 15sec ON/90 sec OFF in a bioruptor (Diagenode) at 4°C ...
-
bioRxiv - Genomics 2022Quote: A total of 15 μg of extracted genomic DNA was sheared using a Megaruptor (Diagenode, Denville, NJ). The large DNA fragment was recycled by BluePippin (Sage Science ...
-
bioRxiv - Genomics 2022Quote: ... DNA was sheared for 26 cycles of shearing (15s on, 30s chilling) using a Bioruptor sonicator (Diagenode), then size selected using SPRI beads (Beckman ...
-
bioRxiv - Microbiology 2022Quote: ... from input and ChIP’d DNA using MicroPlex Library Preparation Kit v2 (12 indices) (Diagenode cat no. C05010013). Libraries were pooled and sequenced with Illumina Novaseq 6000 ...
-
bioRxiv - Genomics 2022Quote: ... DNA purification and library preparation were done on IP-Star® Compact Automated System (Diagenode Cat# B03000002).
-
bioRxiv - Cancer Biology 2023Quote: ... Immunoprecipitation of EdU-containing DNA was performed using the iDeal ChIP-seq kit for Transcription Factors (Diagenode) with the following modifications ...
-
bioRxiv - Cancer Biology 2023Quote: ... and samples were sonicated to an average DNA length of 200–400 bp with a bioruptor (Diagenode). After sonication ...
-
bioRxiv - Molecular Biology 2024Quote: ... The DNA was sheared by sonication (4x 7 cycles, 30s on / 30s off, power high; Bioruptor, Diagenode) at 4°C and lysates cleared by centrifugation at 16,100 x g at 4°C for 15 min ...
-
bioRxiv - Genetics 2024Quote: ... 5 μg of genomic DNA from each treatment condition was sheared using a bioruptor sonication device (Diagenode) in low mode for two cycles (30s on + 60s off ...
-
bioRxiv - Genomics 2019Quote: ... High molecular weight DNA was sheared to ∼8kb using Covaris g-tubesTM (Woburn, MA) or a Megaruptor (Diagenode), followed by end-repair using the NEBNext EndRepair Module (New England Biolabs) ...
-
bioRxiv - Molecular Biology 2021Quote: ... Cross-linking was reversed at 65°C overnight and immunoprecipitated DNA was recovered using the IPure Kit (Diagenode). Genomic regions of interest were identified by realtime PCR (qPCR ...
-
bioRxiv - Genomics 2019Quote: ... DNA was extracted using phenol:chloroform and sheared to 150bp fragments on a Bioruptor® Plus sonication device (Diagenode).
-
bioRxiv - Genomics 2019Quote: ... An aliquot of 5 µg DNA was mechanically sheared with a bath sonicator (Diagenode BioRuptor, Diagenode, Liège, Belgium) and low molecular weight fragments were used for the preparation of DNA libraries.
-
bioRxiv - Genomics 2019Quote: ... An aliquot of 5 µg DNA was mechanically sheared with a bath sonicator (Diagenode BioRuptor, Diagenode, Liège, Belgium) and low molecular weight fragments were used for the preparation of DNA libraries.
-
bioRxiv - Genomics 2021Quote: ... A total of 10 μg of DNA was purified then sheared at 40kb using the Megaruptor system (Diagenode). Using SMRTBell template Prep Kit 1.0 (PacBio) ...
-
bioRxiv - Cancer Biology 2021Quote: ... Adapter-ligated DNA was subjected to immunoprecipitation with a primary monoclonal antibody against 5-methyl cytosine (Diagenode C15200081) using a previously published protocol [71] ...
-
bioRxiv - Cancer Biology 2022Quote: ... sonicated until the lysates were clear of long DNA and other visible cell debris (Diagenode Bioruptor Plus sonicator). Lysates were processed by the Multi-Enzyme Digestion Filter Aided Sample Preparation (MED FASP ...
-
bioRxiv - Developmental Biology 2021Quote: ... the synthetic DNA was fragmented into 350-bp pieces by a Bioruptor® Sonication System (UCD300, Diagenode Inc.), and the reactions were purified by incubation with Ampure XP beads (A63880 ...
-
bioRxiv - Evolutionary Biology 2019Quote: HMW genomic DNA was sheared to 30 kb using a Megaruptor® 2 instrument (Diagenode SA, Seraing, Belgium). DNA-damage and end repair was carried out prior to blunt adaptor ligation and exonuclease purification using ExoIII and ExoVII ...
-
bioRxiv - Genomics 2019Quote: ... Purified DNA was used as input for library preparation with MicroPlex Library Preparation Kit v2 (Diagenode, cat. C05010012) and processed according to the manufacturer’s instruction ...
-
bioRxiv - Genomics 2019Quote: ... Purified DNA was used as input for library preparation with MicroPlex Library Preparation Kit v2 (Diagenode, cat. C05010012) and processed according to the manufacturer’s instruction ...