Labshake search
Citations for Stemcell Technologies :
1751 - 1767 of 1767 citations for Rat Insulin like growth factor binding protein 6 IGFBP6 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2020Quote: ... 1 x 105 T cells purified from spleen and lymph nodes with the EasySep Mouse T cell Isolation Kit (Stem Cell Technologies; Vancouver, BC, Canada) were cultured with 4 x 105 T-depleted splenocytes in 96-well round bottom plates in R10 media with 1 μg/mL αCD3 ...
-
bioRxiv - Immunology 2022Quote: ... successfully transduced cells were enriched based on CD19t expression on day 11-15 using EasySep™ Human CD19 Positive Selection Kit II (Stemcell Technologies, Inc., Cat#17854), and the resulting CAR+ T cells were cryopreserved at day 15 or 17 ...
-
bioRxiv - Neuroscience 2019Quote: ... splenocytes were further separated by negative selection using the EasySep T cell isolation kit designed for CD3+ T cells (Stem Cell Technologies, Vancouver, BC, Canada) following the manufacturer’s guidelines for manual separation ...
-
bioRxiv - Immunology 2021Quote: ... Memory CD4+ or CD8+ T cells were either isolated from PBMCs by EasySep Human Memory CD4+ or CD8+ T cell enrichment kit (STEMCELL Technologies, Cat#: 19157 or 19159), or isolated from purified CD4+ or CD8+ T cells by CD45RO microbeads (see Suppl ...
-
bioRxiv - Immunology 2020Quote: ... CD4T cells were negatively isolated from the digested spleen and LNs of indicated donor mice with Mouse CD4T Cell Isolation Kit (STEMCELL Technologies 19852 or BioLegend 480033) according to the manufacturer’s protocol and labeled with 1.0 μM CFSE (Thermo Fisher ...
-
bioRxiv - Microbiology 2024Quote: ... Bulk CD4+ T cells were subsequently isolated from PBMCs by magnetic negative selection using an EasySep Human CD4+ T cell isolation kit (STEMCELL Technologies; per the manufacturer’s instructions). Isolated CD4+ T cells were suspended in RPMI 1640 (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: Astrocyte precursor cells were created from the neural progenitor cells described above using the STEMdiff Astrocyte Differentiation media kit from STEMCELL Technologies (Cat No. 100-0013) following their protocol for Matrigel-coated 6-well plates [30] ...
-
An indocyanine green-based liquid biopsy test for circulating tumor cells for pediatric liver cancerbioRxiv - Cancer Biology 2023Quote: Samples were depleted of cells of an immune origin with the RosetteSep CD45 depletion kit (depletes with antibodies for CD45, CD66, and Glycophorin A, cat. no. 15122, Stem Cell Technologies, Cambridge, MA USA) according to the protocol with SepMate - 15 tubes (cat ...
-
bioRxiv - Cancer Biology 2023Quote: The first step consists in a CTC enrichment from whole blood sample by immunomagnetic negative selection using the EasySep™ Direct Human CTC Enrichment Kit (StemCell Technologies®, Vancouver, Canada) according to manufacturer instruction ...
-
bioRxiv - Cell Biology 2023Quote: Transduced lineage negative (Lin-) or Lin-Sca-1+Kit+ (LSK) cells were plated into 1mL of methylcellulose-based medium with cytokines (Stem Cell Technology, MethoCult GF M3434) into 35 x 10 mm non-adherent Bio-One Petri Dish ...
-
bioRxiv - Cell Biology 2024Quote: Primary human T cells were isolated from the peripheral blood of a healthy donor using a negative selection kit (EasySep, STEMCELL Technologies Canada Inc., Vancouver, BC) and used for testing the sensitivity of the lifetime flow system to T cell activation ...
-
bioRxiv - Immunology 2024Quote: T cells were extracted from OT-II mouse spleens and magnetically sorted using a T-cell extraction kit from Stem Cell Technologies (catalog number 19851). Cells were incubated in culture media (RPMI+ 10% HIFBS + Pen/Strep + 1 mM HEPES + 50 μM beta mercaptoethanol ...
-
bioRxiv - Bioengineering 2024Quote: ... PBMC samples were thawed on the day of activation and T cells were purified via the EasySep™ Human CD8+ T Cell Enrichment Kit (StemCell Technologies Inc, cat#19053). Isolated T cells were seeded in the CD3/CD28 precoated well plates at a concentration of 500,000 cells/mL with 1 mL/well in ImmunoCult™-XF T Cell Expansion Medium (StemCell Technologies Inc ...
-
bioRxiv - Immunology 2024Quote: ILCs from Alt and Alt plus BPC treated mice were enriched from two single-cell suspended lungs by Mouse Pan-ILC Enrichment Kit (STEMCELL Technologies, Vancouver, British Columbia, Canada). ILC enriched samples were preserved in PIPseqTM T100 3L Single Cell Capture and Lysis Kit and processed by sequencing service (Fluent BioSciences ...
-
bioRxiv - Immunology 2022Quote: ... CD8+ T-cells were negatively isolated from PBMC by magnetic separation using the EasySep Human CD8+ T-Cell Enrichment Kit (Stemcell Technologies; average purity 93%, n=16).
-
bioRxiv - Cancer Biology 2023Quote: ... T cells were then isolated using EasySep™ Human T Cell Isolation Kit and EasySep™ Magnet (Stemcell Technologies, Cat. No. 17951 and Cat. No. 18000) following manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2022Quote: ... all the unwanted cells were labelled with magnet conjugated antibody cocktail which is separated using their EasySep magnetic stand leaving CD4 or CD8 cell in suspension using the vendor supplied EasySep Human CD4/CD8 T Cell Iso Kit (Stem Cell Technologies, 17952 for CD4 and 17953 for CD8). This negative selection approach results in isolation of untouched CD8 or CD4 T cells and stored frozen with 10% DMSO (MP Biomedicals ...