Labshake search
Citations for Bio-Rad :
1151 - 1200 of 4573 citations for 14 Nonylphenoxy 3 6 9 12 tetraoxatetradecan 1 ol since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2024Quote: ... cooled on ice and equal volume was loaded on 4-12% Midi-PROTEAN TGX stain-free protein gels (cat# 4568093, Bio-Rad Laboratories); the gel was then transferred to PVDF membranes using the Trans-Blot Turbo Transfer System(BIO-RAD ...
-
bioRxiv - Cell Biology 2024Quote: ... was loaded on 10-12% TGX Stain-free SDS-PAGE gel (Bio Rad, 1610183 and 1610185) and transferred to PVDF membrane (Bio-Rad, 1620177). Primary antibodies used in this study were as follows ...
-
bioRxiv - Neuroscience 2024Quote: ... Vector purity was assessed by 4–12% sodium dodecyl sulfate–polyacrylamide gel electrophoresis and fluorescent staining (Oriole, Bio-Rad, Hercules, CA, USA). A transfer plasmid (pAAV-CMV-eNpHR3.0-EYFP-WPRE ...
-
bioRxiv - Microbiology 2024Quote: ... The PCR reaction mixture in each sample consisted of 12 µL of 2x Supermix for Probes (No dUTP) (Bio-Rad, cat.no.1863023), 1.2 µL of each primers/probe mixture (Prime-Time Std qPCR assay (500 reactions) ...
-
bioRxiv - Molecular Biology 2024Quote: ... Equal amounts of cellular proteins were resolved on 12% sodium dodecyl sulfate – polyacrylamide gels (SDS-PAGE) and subsequently transferred to nitrocellulose membranes (Bio-Rad Laboratories). Membranes were blocked using 5% non-fat dry milk or 5% bovine serum albumin (BSA ...
-
bioRxiv - Microbiology 2024Quote: ... Protein samples were resolved using 4-12% Bis-Tris SDS-PAGE gel and stained with Coomassie Brilliant Blue (Bio-Rad Cat#1610436). Protein identity was confirmed by western blotting using anti-GST (1:5000 ...
-
bioRxiv - Neuroscience 2024Quote: ... Samples were resolved on 10-12% sodium dodecyl sulfate (SDS) polyacrylamide gel at 150V for 2 h using Mini-PROTEAN tetra cell (Bio-Rad, #1658004). Proteins were transferred on nitrocellulose membrane at 100V for 2 h using the Mini trans-blot cell (Bio-Rad ...
-
bioRxiv - Cancer Biology 2024Quote: ... A total of 40 µg of protein from each sample was resolved on a 12% polyacrylamide gel via SDS-PAGE and subsequently transferred to a PVDF membrane (Bio-Rad, 1620177) using a wet transfer system ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were heated to 37°C for 30 minutes and equal concentrations of samples (15μg) were resolved on Criterion 12% gels (Bio-Rad, Cat# 5671044) and transferred to PVDF (Bio-Rad ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were subjected to SDS-PAGE on 8 to 12% of polyacrylamide and samples were run with a PowerPac Basic (Bio-Rad Laboratories) at 90-120 Volts for 60-90 minutes in a Mini-Protean® 3 Cell (Bio-Rad Laboratories) ...
-
bioRxiv - Cell Biology 2024Quote: IP eluates and inputs (saved at beginning of stage iii) were loaded on 4–12% Criterion XT Bis-Tris precast protein gels (Bio-Rad #3450124), run in NuPAGE MOPS SDS running buffer (Invitrogen ...
-
bioRxiv - Genomics 2020Quote: Lysates were separated by SDS-PAGE on 3-8% Tris-acetate gels (BioRad #3450129) for 2.5 hours at 150V ...
-
bioRxiv - Biophysics 2021Quote: ... Detergents were removed by adding 2-3 batches of Bio-beads SM2 (Bio-Rad) with constant rotation for overnight ...
-
bioRxiv - Molecular Biology 2022Quote: ... and 3 µl was used for qPCR with iTaq Universal SYBR Green Supermix (BioRad). Relative levels of RNA were calculated by the ΔΔCt method using GAPDH as an internal control ...
-
bioRxiv - Microbiology 2021Quote: ... The nitrocellulose membrane was soaked (blocked) in 3% milk (dry milk from Bio-Rad) solution in 1x PBS following by incubation with appropriate primary antibody solution (1:1000 dilution ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... washed 3 times and developed with ECL reagent (Bio-Rad Laboratories, Hercules, CA, USA). Invertase blots were prepared similarly with an anti-invertase antibody and anti-goat IgG HRP ...
-
bioRxiv - Molecular Biology 2021Quote: ... SDS-PAGE and Western blotting were performed using the Mini-PROTEAN 3 system (Biorad). Blotted membranes were blocked in 5% BSA / TBS-Tween ...
-
bioRxiv - Immunology 2024Quote: ... Samples were diluted in Laemmli sample loading buffer supplemented with |3-mercaptoethanol (Bio-Rad), heated for 5 min at 95°C ...
-
bioRxiv - Physiology 2023Quote: ... Blotting membrane was primed for 3 min prior in cold transfer buffer (BIORAD 10026938), according to manufacturer specifications ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... kinase-dead extracts were incubated 3 consecutive times with protein A-beads (Bio-Rad) previously coated with the anti-B55δ antibody (1 hour incubation at 4°C ...
-
bioRxiv - Microbiology 2023Quote: ... samples were run through Criterion XT Tris-acetate precast gels (3-8% gradient) (Biorad) in a XT tricine buffer (Biorad) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Reactions were loaded onto a 3% agarose gel and visualized on a Chemidoc (BioRad). Bands were densitometry quantified by ImageJ and the percentage of methylated DNA was calculated over the total intensity of all the quantified bands.
-
bioRxiv - Molecular Biology 2023Quote: ... 3 μg of the protein samples were prepared with 4X Laemmli loading buffer (Biorad) and denatured at 95°C for 5 minutes ...
-
bioRxiv - Immunology 2023Quote: ... 3) live cell populations using live-dead exclusion dye (Zombie Aqua, #423101, Bio-Rad); 4 ...
-
bioRxiv - Molecular Biology 2023Quote: ... SDS-PAGE and Western blotting were performed using the Mini-PROTEAN 3 system (Biorad). Blotted membranes were blocked in 5% BSA / TBS-Tween ...
-
bioRxiv - Cancer Biology 2024Quote: ... Membranes were washed 3 times with TBST before exposure using a Chemidoc system (BioRad).
-
bioRxiv - Microbiology 2024Quote: ... then 3 μL from each well was spotted onto a nitrocellulose membrane (Bio-Rad) and allowed to dry for at least 30 minutes in a fume hood at room temperature ...
-
bioRxiv - Immunology 2024Quote: ... and hFAB rhodamine anti-glyceraldehyde-3-phosphate dehydrogenase (GAPDH) (catalog number 12004168; Bio-Rad) (1:10,000).
-
bioRxiv - Bioengineering 2024Quote: ... and 3 mM MgCl2) on a CFX96 thermocycler with an optical module (Bio-Rad) by the following protocol ...
-
bioRxiv - Biochemistry 2024Quote: ... the DDM was removed by 3 additions of SM-2 bio-beads (Bio-Rad), incubated for 2h/2h/overnight ...
-
bioRxiv - Developmental Biology 2021Quote: ... Sections were incubated overnight at 4 °C with rabbit anti-chick IL-6 (Bio-Rad Laboratories, Inc., Hercules, CA) diluted 1:20 in incubation buffer ...
-
bioRxiv - Cell Biology 2022Quote: ... Excess dye was removed by two consecutive buffer exchanges through Micro Bio-Spin P-6 desalting columns (Bio-Rad). Protein concentration and labeling efficiency were estimated using a NanoDrop Microvolume Spectrophotometer.
-
bioRxiv - Biochemistry 2020Quote: ... 0.14 M NaCl (PBS) followed by removal of the reductant using a Micro Bio-Spin 6 column (Bio-Rad). Columns were washed and pre-equilibrated with 20 mM phosphate buffer pH 7.4 containing 0.1 mM diethylenetriamine-penta-acetic acid (DTPA ...
-
bioRxiv - Biochemistry 2021Quote: ... individual proteins were buffer exchanged into 200 mM ammonium acetate pH 8.0 either by SEC or using Biospin-6 (BioRad) columns and introduced directly into the mass spectrometer using gold-coated capillary needles (prepared in-house) ...
-
bioRxiv - Biochemistry 2020Quote: ... His-tagged protein was detected using a mouse anti-6×His IgG conjugated to horseradish peroxidase (MCA1396P; Bio-Rad), and the blot was developed using Pierce™ ECL Western Blotting Substrate (Thermo Fisher Scientific).
-
bioRxiv - Biochemistry 2020Quote: ... The annealed doubly nicked DNA duplex was then buffer-exchanged in Hepes 20 mM pH 7.5 with a BioSpin 6 column (BioRad).
-
bioRxiv - Microbiology 2022Quote: All proteins were buffer exchanged into 0.2 M ammonium acetate using Bio-Spin P-6 Size Exclu-sion Spin Columns (BioRad) as previously described47 ...
-
bioRxiv - Genetics 2022Quote: ... PMOs were buffer exchanged into 25 mM ammonium bicarbonate buffer pH 7.5 using Biospin 6 (Bio-rad, Hercules, California) columns according to the manufacturer’s protocol and then spinning through an 0.22 µm cellulose acetate centrifugal spin filter ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... The Chlorella DNA was extracted by isolating the Chlorella and then using a standard 6% Chelex100 resin (Bio-Rad) extraction method ...
-
bioRxiv - Microbiology 2021Quote: ... pH 7.4) in D2O using Micro Bio-Spin® Columns with Bio-Gel® P-6 (Bio-Rad Laboratories). Protein (final concentration 20 µM ...
-
bioRxiv - Immunology 2020Quote: ... Mono-Mac-6 effector cells previously stimulated with recombinant human IFN-ɣ (Bio-Rad, Hercules, CA, USA; cat. PHP050) at 0.2 µg ml-1 for 3h at 37 °C ...
-
bioRxiv - Immunology 2022Quote: ... Excess free Texas Red or TAMRA were removed with Bio-spin 6 kDa size exclusion columns (Bio-Rad Laboratories) equilibrated with PBS according to manufacturer’s instructions ...
-
bioRxiv - Plant Biology 2023Quote: ... Samples containing 6 µg total protein were resolved using pre-cast SDS-PAGE Any KD™ gels (BIO-RAD), transferred to a polyvinylidene difluoride membrane (Immobilon-FL 0.45 µm ...
-
bioRxiv - Pathology 2023Quote: ... Heparin Sepharose 6 Fast Flow beads (Healthcare Life Sciences) were loaded into Bio-Spin® chromatography columns (Bio-Rad) and packed with 2 ml of equilibration buffer (0.15 M NaCl in 25 mM HEPES ...
-
bioRxiv - Genomics 2023Quote: ... Excess dye was removed using Micro Bio-Spin® Columns with Bio-Gel® P-6 (cat:7326221, BioRad) by centrifugation at 1000g ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The reactions were run at 125 V for 2.5 hours on a denaturing (6 M urea) 20% (w/v) polyacrylamide gel in 50 mM NaOAc pH 5.2 running buffer (using the Biorad Mini- PROTEAN tetra gel ...
-
bioRxiv - Microbiology 2023Quote: ... resuspended in 400 µL cold PBS and electroporated with 6 µg of RNA in 0.4-cm electroporation cuvettes (Biorad) with a 950 μF and 260 V pulse using Genepulser system (Biorad) ...
-
bioRxiv - Biochemistry 2024Quote: ... The reactions were run at 125 V for 2.75 hours on a denaturing (6 M urea) 20% (w/v) polyacrylamide gel in 50 mM NaOAc pH 5.2 running buffer (using the Biorad Mini-PROTEAN tetra gel ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Imaging was performed using the Silver Stain setting on Image Gel 6 on Gel Doc EZ Imager (Bio-Rad). ImageJ software was used for band intensity quantification as described below.
-
bioRxiv - Cancer Biology 2021Quote: ... The eluted proteins were separated by NuPAGE 4-12% Bis-Tris gel in MES SDS running buffer and transferred to a PVDF membrane (Bio-Rad, 162-0263). Tubulin beta chain protein was detected with an anti-TUBB antibody (1:500 in 5% fat-free milk solution in TBST ...