bioRxiv - Neuroscience 2020Quote: ... extracellular suction electrodes were made from borosilicate glass capillaries with an outer diameter of 1.5 mm and inner diameter of 0.84 mm (World Precision Instruments) using a micropipette puller (HEKA PIP 6) ...
-
bioRxiv - Neuroscience 2020Quote: Pipettes for OGB injections were pulled from borosilicate glass capillaries (1B150F-4, outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments) using a micropipette puller (P-97 ...
-
bioRxiv - Bioengineering 2022Quote: ... The virus is delivered through a small durotomy by a glass micropipette using a microsyringe pump (Nanoliter 2000 injector with the Micro4 controller, WPI).
-
bioRxiv - Neuroscience 2020Quote: ... were dissected into fine multiunit branches and a single branch was placed within a sealed glass pipette containing a microelectrode (WPI) attached to a Neurolog headstage (NL100AK ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch-clamp recording pipettes were fabricated from 1 mm inner diameter borosilicate glass capillaries (World Precision Instruments, item# 1B100F-4). Pipettes were pulled with a multistep horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2021Quote: ... Stimulation pipettes were made from 1.50 OD/1.02 ID thick septum theta borosilicate glass capillaries (TST150-6; World Precision Instruments) using a P-97 micropipette puller and filled with ACSF ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (2–5 MΩ) were pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments) on a Sutter P-97 puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 20-30 nl/minute into the parenchyma ...
-
bioRxiv - Neuroscience 2020Quote: Whole cell patch-clamp recordings in current clamp mode were made from retrogradely traced fluorescently labelled lumbosacral (L5-S1) bladder-innervating DRG neurons using borosilicate glass pipettes (WPI) fire-polished to 3 to 7 MΩ and back-filled with an intracellular solution consisting of (in mM) ...
-
bioRxiv - Physiology 2021Quote: ... Tissue was secured onto glass slide with a biorthogonal silicon elastomer (Kwik-Sil) (World Precision Instruments, Sarasota, FL-KWIK-SIL), and a glass coverslip ...
-
bioRxiv - Neuroscience 2021Quote: ... was transferred to a glass Petri dish to which it was glued with KWIK-SIL (World Precision Instruments, Berlin, Germany). The Petri dish was filled with ECi and then placed on the stage of an upright CFS 6000 microscope equipped with a TCS-SP5 AOBS scan head (Leica Microsystems ...
-
bioRxiv - Neuroscience 2021Quote: ... A solution containing 100-200 nl viral construct was loaded into a pulled glass capillary and injected into the target region using a Nanoinjector (WPI). Optic fibers (0.2 mm diameter ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch clamp recordings were obtained with glass pipette electrodes pulled from borosilicate capillaries (World Precision Instruments, Sarasota, FL) on a P97 Flame/Brown Puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were performed with low resistance (1–3 MΩ) glass pipettes (ID: 0.68 mm, OD: 1.2 mm, WPI, Sarasota, FL) filled with aCSF under current-clamp mode with I=0 configuration ...
-
bioRxiv - Biophysics 2023Quote: Samples were introduced to the mass spectrometer by gold-coated capillaries made from borosilicate glass tubes (inner diameter: 0.68 mm, outer diameter: 1.2 mm; World Precision Instruments). Capillaries were pulled in a two-step program using a micropipette puller (P-1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... of 7[µm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2[mm O.D., 0.68[mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... A solution containing 50-200 nl viral construct was loaded into a pulled glass capillary and injected into the target region using a Nanoinjector (WPI). For EEG and EMG recordings ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2022Quote: ... and the pellet was resuspended in NBA-B27.The suspension was transferred on 35 mm diameter glass-bottomed Petri dishes (WPI) coated with poly-L-lysine and laminin and incubated at 37°C with 5% CO2.
-
bioRxiv - Neuroscience 2023Quote: ... Cells expressing YFP and with a soma diameter <25 µm were targeted for whole cell recording using pipettes (∼5 MΩ resistance) pulled from borosilicate glass (WPI).
-
bioRxiv - Cell Biology 2024Quote: ... 0.45 mm under the medullary surface) using a calibrated glass micropipette attached to a Nanoject II injector (Drummond) microprocessor pump (Pneumatic PicoPump; WPI). Over 5 minutes ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained using patch pipettes pulled from borosilicate glass capillaries (1B120F-4, World Precision Instruments). Pipette tip resistances were ∼4-10 MΩ for amacrine cell recordings in the ganglion cell layer ...
-
bioRxiv - Neuroscience 2024Quote: ... The PSC was identified under a surgical microscope and a glass micropipette pulled to a fine point was positioned using a micro-injector (WPI). For each mouse only one ear was injected with ∼1.2 µL AAV solution containing gene sequences encoding optical GABA indicator (iGABASnFR ...
-
bioRxiv - Developmental Biology 2024Quote: ... Concentrated virus was injected into either mature or blastema tissue using glass capillary needles and a PV830 picopump (WPI, Sarasota) using standard protocols42 ...
-
bioRxiv - Cell Biology 2023Quote: ... 0.35 μL of the diluted dsRNA was loaded into the back of pulled borosilicate glass capillary needles (World Precision Instruments, WPI ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were made using electrodes (2-6MΩ) pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments). They were filled with a pipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Tracers were applied to the brain through a glass pipette (ID = 0.530 mm ± 25 um, OD 1.14 mm, World Precision Instruments). The flow rate of the injections was 1 nl/sec ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled to resistances of ∼3 MΩ from thin-walled glass capillaries (World Precision Instruments, Cat# 1B120F-4). Importantly ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (2–4MU) were pulled from filamental borosilicate glass capillaries (1.5 mm OD, 0.84 mm ID; World Precision Instruments) Patch pipettes were filled with internal solution containing (mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... was used to create a micropipette (tip diameter 30-50 µm) from a micro glass tube (1.0-mm diameter; TW100F-4; WPI, USA). The pulled micropipette was then beveled using a micro grinder (EG-402 ...
-
bioRxiv - Cancer Biology 2022Quote: ... Borosilicate glass capillaries with a length of 4 inches and an OD of 1.0 mm (World Precision Instruments, FL, USA) were used for microinjection ...
-
bioRxiv - Neuroscience 2023Quote: ... VP neurons were visualized using an Olympus BX51WI microscope and recorded from using glass pipettes (1.3-2.5 MΩ, World Precision Instruments) filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Fine glass-pulled pipette tips were purchased at a calibrated 10.0 µm diameter (TIP10TW1-L; World Precision Instruments, Sarasto, FL). The entire Hamilton syringe with fitted pipette tip was filled with mineral oil to create a hydraulic continuity between the plunger and aspirated virus ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipette electrodes with a tip resistance between 10 and 14 MΩ for cones and 6-8 for horizontal cells were pulled from thick-walled borosilicate glass (1.5 mm outer diameter; 0.84 mm inner diameter; World Precision Instruments).
-
bioRxiv - Neuroscience 2024Quote: ... A solution containing 50-200 nl viral construct was loaded into a pulled glass capillary and injected into the target region using a Nanoinjector (WPI). Optical fibers (0.2 mm diameter ...
-
bioRxiv - Neuroscience 2024Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 30-40 nl/min into the parenchyma ...
-
bioRxiv - Molecular Biology 2024Quote: The branch-free segment of the MCA-M2 was cannulated onto glass micropipettes (1B120-6, World Precision Instruments, Sarasota, FL) and mounted in a pressure myograph chamber (Living System Instrumentation ...
-
bioRxiv - Molecular Biology 2024Quote: ... pH 7.2) was clarified by centrifugation prior to insertion into 1 mm diameter quick-fill glass capillaries (World Precision Instruments) pulled to fine tips using a Narishige PC-10 puller (Narishige International USA ...
-
bioRxiv - Neuroscience 2024Quote: ... Sections of mPFC were punched out using thin-walled borosilicate glass capillary tubes (length of 75 mm, outer diameter of 1.5 mm, inner diameter of 1.1 mm; World Precision Instruments). Once extracted ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were made at depths of 200 and 350 μm below the pial surface using glass pipettes and a microinjection system (UMP3 UltraMicroPump, WPI). Finally ...
-
bioRxiv - Developmental Biology 2021Quote: Micropipettes for electrocardiograph (ECG) measurement on whole zebrafish larvae were prepared by pulling fire-polished borosilicate glass capillaries (World Precision Instruments) using the Flaming/brown micropipette puller P-1000 (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2021Quote: ... Craniotomies were made using a 0.5 mm burr and viral vectors were delivered using pulled glass pipettes coupled to a microsyringe pump (Micro4, World Precision Instruments) on a stereotaxic frame (Model 940 ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole-oocyte currents were recorded by two-electrode voltage clamp (GeneClamp500B, Axon Instruments, Foster City, CA, USA) using microelectrodes made of borosilicate glass (WPI, USA) with a resistance of 0.5–1MΩ when filled with 2.5M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... The craniotomy was sealed with agarose (1.5–2%, dissolved in artificial cerebrospinal fluid) and a 5 mm glass coverslip (World Precision Instruments) was placed over it ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Biophysics 2020Quote: The nanopipettes with ∼60 nm diameters were fabricated from quartz glass capillaries of 0.5 mm inner diameter (QF100-50-7.5, World precision Instruments, UK) using a Sutter instrument model P-2000 laser puller ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... 500nl AAV9-hSyn-OT1.0 or AAV9-hSyn-OTmut viruses were delivered into the BNST (AP: −0.45 mm, ML: −0.9 mm, DV: −3.6 mm) through a glass capillary using nanoinjector (World Precision Instruments, Nanoliter 2000). After virus injection ...
-
bioRxiv - Neuroscience 2021Quote: ... A long tempered small tip (2 — 3 μm in diameter) patch pipette (∼3 MΩ; borosilicate glass, WPI, GBF 150-86-10) was used to pressure inject the dye into the extracellular space at 4 — 6 psi for 14 minutes ...