Labshake search
Citations for World Precision Instruments :
1 - 50 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Viruses were injected at 100 nL/min using micropump (WPI) with micropipettes (Drummond ...
-
bioRxiv - Neuroscience 2024Quote: ... A microinjection syringe (WPI) equipped with a 34g bevelled needle (WPI ...
-
bioRxiv - Neuroscience 2024Quote: ... equipped with a 34g bevelled needle (WPI) was filled with corresponding AAV (Table S2 ...
-
bioRxiv - Neuroscience 2024Quote: ... a small bundle of fibers was aspirated into a patch-pipette connected to a high gain AC differential amplifier (model DAM 80; World Precision Instruments). A reference electrode was positioned inside the chamber ...
-
bioRxiv - Neuroscience 2024Quote: ... The craniotomies were typically filled with silicone sealant (Kwik-Cast, World Precision Instruments) and the skin closed with liquid suture (VetBond ...
-
bioRxiv - Physiology 2024Quote: ... and injection volumes controlled with a microsyringe pump controller (WPI, Micro4). After loading of viral injectate and positioning of the micropipette near the uterine horn ...
-
bioRxiv - Physiology 2024Quote: ... positioned with a micromanipulator (WPI, MP-285), and injection volumes controlled with a microsyringe pump controller (WPI ...
-
bioRxiv - Physiology 2024Quote: ... Micropipettes were mounted in a microinjection pump (WPI Nanoliter 2010), positioned with a micromanipulator (WPI ...
-
bioRxiv - Neuroscience 2024Quote: Signals were subtracted and amplified with a differential amplifier (DAM50, World Precision Instruments) and digitized at 10 kHz (USB-6001 ...
-
bioRxiv - Neuroscience 2024Quote: ... borosilicate glass (outer diameter, 1.5 mm; inner diameter, 1.17 mm; World Precision Instruments, Sarasota, FL) on a vertical two-stage puller (Narishige ...
-
bioRxiv - Neuroscience 2024Quote: ... injection system with a microsyringe (Hamilton, Reno, NV, USA) attached to a Micro4 Microsyringe Pump Controller (World Precision Instruments, Sarasota, FL, USA) was used to microinject 0.3 ul of AAV2-mCherry (titer ...
-
bioRxiv - Neuroscience 2024Quote: ... An UltraMicroPump (World Precision Instruments, Sarasota, FL, USA) injection system with a microsyringe (Hamilton ...
-
bioRxiv - Neuroscience 2024Quote: ... The glass window was removed and a tungsten microelectrode with an impedance of 0.5 MΩ (World Precision Instruments, Sarasota, FL, USA) was inserted to a depth of 1.5 mm from the cortical surface ...
-
bioRxiv - Neuroscience 2024Quote: ... was placed partially inside a capillary tube (#1B120F-4; World Precision Instruments; Sarasota, FL) and then saturated with tastant ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... a nanoliter injector was used (SYS-Micro4, WPI, Sarasota, FL, USA). Oocytes were cultured at 17°C in Barth’s medium ...
-
bioRxiv - Neuroscience 2024Quote: Patch electrodes were created from 4in thin wall borosilicate glass (TW150F-4, World Precision Instruments) and pulled with a Narishige Model PC-10 were filled with the following (in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... Brain tissue was then covered with a thin layer of kwik sil (WPI, France) and the grin lens position secured with C&B-Metabond (Parkell ...
-
bioRxiv - Neuroscience 2024Quote: ... were delivered by a twisted bipolar microelectrode (0.5 MΩ, World Precision Instruments, Sarasota, FL) driven by an ISO-Flex stimulus isolation unit controlled by a Master-8 pulse generator (A.M.P.I. ...
-
bioRxiv - Microbiology 2024Quote: ... with an Apollo 4000 System (WPI, UK). For H2O2 measurements ...
-
bioRxiv - Neuroscience 2024Quote: ... and Kwik-Kast (WPI) was used to protect the exposed lens surface ...
-
bioRxiv - Cell Biology 2024Quote: ... and injected with 3 μl of AAV9-hSyn-iCre (titer 1 x 1013 to 2 x 1014) into the right lateral ventricle using a nanoliter injector (World Precision Instruments; Micro4 MicroSyringe Pump Controller connected with Nanoliter 2000 ...
-
bioRxiv - Neuroscience 2024Quote: ... which was attached to a microprocessor-controlled nanoliter injector (Nanoliter 2000; World Precision Instruments). AAV.mDlx.GCaMP6f (Addgene ...
-
bioRxiv - Microbiology 2024Quote: ... Transepithelial electrical resistance (TEER) was measured using a manual Epithelial Volt Ohm Meter (EVOM2; World Precision Instruments), after which 100 µM BPP43_05035 ...
-
bioRxiv - Neuroscience 2024Quote: ... A 33-gauge blunt needle attached to a Nanofil (WPI, USA) was used for viral injections (500-600 nL/brain site) ...
-
bioRxiv - Neuroscience 2024Quote: ... Two 0.5 μL injections (World Precision Instruments syringe with 36 needle) of AAV1-Syn-Chrimson-tdT21 were made into the caudal medulla 1mm lateral to obex ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... the cells were plated at 20,000 per cm2 on 35 mm dishes (World Precision Instruments, Inc, #FD 35-100) pre-coated with collagen I (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2024Quote: ... Neurons were harvested using a thin wall glass capillary tube (4 inch, OD 1.0 MM, World Precision Instruments) into EBSS in a non-stick Eppendorf tube and kept on ice until dissociation.
-
bioRxiv - Cancer Biology 2024Quote: ... Concentrated cell suspension was loaded into a microcapillary (World Precision Instruments, TW100-4) connected to a FemtoJet 4x (Eppendorf) ...
-
bioRxiv - Neuroscience 2024Quote: ... where dummy cannulae were replaced by microinjectors connected to infusion pumps (World Precision Instruments, Sarasota, FL) with PE50 tubing ...
-
bioRxiv - Neuroscience 2024Quote: ... For all surgical procedures mice were anesthetized using 1.5-2% isoflurane and were injected using a Kopf stereotaxic and World Precision Instruments (WPI) microinjection syringe pump with a 10 mL syringe and 33g blunt needle at 50-100 nL/min ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (4-8MΩ) were made from borosilicate glass (World Precision Instruments) using a Sutter Instruments P-97 model puller.
-
bioRxiv - Biophysics 2024Quote: ... and fire-polished using a Micro-forge (MF-200, World Precision Instruments) to obtain a resistance ranging from 1 MΩ to 8 MΩ when filled with the patch solution ...
-
bioRxiv - Neuroscience 2024Quote: ... which was then covered with a silicon polymer (Kwik-sil or Kwik-cast, WPI), and the mouse was returned back to its home cage ...
-
bioRxiv - Neuroscience 2024Quote: ... The dura was left intact and the craniotomy was covered with silicon (Kwik-Cast, World Precision Instruments).
-
bioRxiv - Neuroscience 2024Quote: ... Theta-glass pipettes (Warner Instruments) connected to a stimulus isolator (WPI) were used for focal stimulation of synaptic potentials ...
-
bioRxiv - Neuroscience 2024Quote: ... FPs were evoked with stimuli (duration: 0.2 ms) applied at 0.033 Hz via a constant-current stimulus isolation unit (WPI) using a concentric Pt- Ir stimulating electrode (FHC ...
-
bioRxiv - Neuroscience 2024Quote: ... a craniotomy (∼1.5 mm diameter) was made over the IC under isoflurane anesthesia and then covered with a silicone sealant (Kwik-Sil, WPI, Sarasota, FL, USA) until recording time ...
-
bioRxiv - Neuroscience 2024Quote: ... dorsoventral from the brain surface [DV] 1.9 mm) at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For the optogenetic silencing experiments (Figure 1H–N) ...
-
bioRxiv - Physiology 2024Quote: ... Multichannel DVC 1000 Voltage/Current clamp apparatus (World Precision Instruments) was used to measure changes in intestinal tissue function ...
-
bioRxiv - Neuroscience 2024Quote: ... The patch pipettes (2.5 – 3.5 MΩ) were fabricated from borosilicate glass tubes (WPI, 1B150F-3) using a horizontal puller ...
-
bioRxiv - Neuroscience 2024Quote: ... Viral vectors were loaded in glass micropipettes (tip diameter 30-45 µm) and pressure injected using a PicoPump (World Precision Instruments). To ensure viral infection of all cortical layers ...
-
bioRxiv - Neuroscience 2024Quote: ... and controller (micro2T, WPI). After 250nL were dispensed ...
-
bioRxiv - Cell Biology 2024Quote: ... PicoNozzle needle mount (World Precision Instruments, Inc; 5430-ALL), and Zeiss Stemi 508 were used for microinjections ...
-
bioRxiv - Neuroscience 2024Quote: ... Electrode and ground screws were connected to an electronic interface board (EIB-16, Neuralynx) via silver wire soldered to each component (Teflon Coated Silver Wire, World Precision Instruments). The implant was fixed to the skull using dental cement (Simplex Rapid ...
-
bioRxiv - Neuroscience 2024Quote: ... Silicon glue (Kwik-Sil, World Precision Instruments) was added to protect the lens from mechanical damage in between experiments ...
-
bioRxiv - Neuroscience 2024Quote: ... Viral vectors (for more information see below for each experiment) were injected using a 10 µl Nanofil Hamilton syringe (WPI, USA) mounted on a stereotaxic frame ...
-
bioRxiv - Cell Biology 2024Quote: ... 1.5 coverslips (FD35-100; World Precision Instruments, Sarasota, FL) or no ...
-
bioRxiv - Microbiology 2024Quote: ... H2O2 concentrations in fresh bulk soils and autoclaved soil slurries were measured using ISO-HPO-100 (WPI, UK) amperometric sensors ...
-
bioRxiv - Neuroscience 2024Quote: Virus was injected using a 34–35 G beveled needle in a 10ul NanoFil Sub-Microliter Injection syringe (World Precision Instruments) controlled by an injection pump (Harvard Apparatus) ...
-
bioRxiv - Cell Biology 2024Quote: ... Resistance measurements were performed 4 days later in triplicate using an EVOM Epithelial Volt/ohm meter (World Precision Instruments). The values represent the average of three replicates minus the background resistance ...