Labshake search
Citations for World Precision Instruments :
301 - 350 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Local field-potential (LFP) activity was recorded using a patch pipette prepared from thin-borosilicate glass (1.5mmOD, 0.84mmID, World Precision Instruments, cat.no. 1B150F-4) pooled and fire-polished on a Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2024Quote: ... craniotomies were sealed with Kwik-Sil (World Precision Instruments; Sarasota, FL), the microdrive and one intraoral cannula (IOCs ...
-
bioRxiv - Cell Biology 2024Quote: ... Briefly 0.1 to 0.2 x 106 cells were seeded in 2 ml of medium in 6-well dishes or 3cm glass-bottomed microscope dishes (World Precision Instruments) or 0.04 x 106 cells were seeded in 300µl of medium in chambers of an 8-well microscopy slide (Ibidi ...
-
bioRxiv - Cell Biology 2024Quote: ... Solution ejection parameters (ejection pressure, time pulse) were controlled by a micropipette pump (PV-850, World Precision Instruments, UK).
-
bioRxiv - Cell Biology 2024Quote: ... between 50,000 and 100,000 U2OS cells were plated on 35 mm glass-bottom fluorodishes (World Precision Instruments, Cat# FD35-100) or 6-well glass-bottom plates (Cellvis ...
-
bioRxiv - Genetics 2024Quote: ... was injected intramuscularly using a Nanofil syringe (WPI, #NANOFIL). Fish were then electroporated using 7 mm tweezer electrodes (NEP GENE #CUY650P10 ...
-
bioRxiv - Genetics 2024Quote: ... 50-100 one-cell-stage WT embryos were injected with the gRNA (150 pg per embryo) and Cas9 mRNA (100 pg per embryo) with a Picopump (World Precision Instruments). Genomic DNA was extracted using 50 μL of NaOH solution (50 mM ...
-
bioRxiv - Genomics 2024Quote: ... transepithelial electrical resistance (TER) was measured using an EVOM2 voltohmmeter (World Precision Instruments). Monolayers judged to be confluent by TER measurement and inspection by light microscopy were transferred to differentiation media (DM ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... we filled a shallow well (WPI’s FluoroDish tissue culture dishes ...
-
bioRxiv - Neuroscience 2024Quote: ... Reference glass electrode and recording glass electrode were created by processing Standard Glass Capillaries (Cat # IB150F-3, World Precision Instruments, USA) with glass puller ...
-
bioRxiv - Cell Biology 2024Quote: Cph1-PM-MDA and MDA-MB-231 cells were seeded at 5x105 cells into a Fluorodish (WPI) and incubated overnight with 5 µM PCB and 1800 μg/mL G418 at 37 °C and 5% CO2 ...
-
bioRxiv - Neuroscience 2024Quote: ... we used a Nanoject 2010 precision microinjector pump (WPI, Sarasota, FL 34240) and borosilicate micropipettes (Drummond ...
-
bioRxiv - Neuroscience 2024Quote: ... the exposed skull area was covered with silicone sealant (Kwik-Cast, WPI). All animals were individually housed after the first surgery and at least 4 weeks elapsed before beginning habituation in preparation for electrophysiological recording ...
-
bioRxiv - Neuroscience 2024Quote: ... The craniotomy was covered with a silicone sealant (Kwik-Cast, WPI) before implants were secured using light-cured dental cement (RelyX Unicem 2 ...
-
bioRxiv - Neuroscience 2024Quote: ... Pressure injection was performed using a 30 μm outer diameter glass micropipette connected to a nanoliter 2000 injector with a Micro4 controller (World Precision Instruments). To inject AAV into the marmoset V1 cortex ...
-
bioRxiv - Physiology 2024Quote: Barrier function was assessed in hPAEpC cultures by trans-epithelial electrical resistance (TEER, EVOM2, World Precision Instruments, UK) in the presence of 50 μL/mL RNAse cocktail (ThermoFisher Scientific ...
-
bioRxiv - Neuroscience 2024Quote: ... the small cranial window was sealed using a drop of kwik-sil (World Precision Instruments) and allowed to cure for 6–8 minutes ...
-
bioRxiv - Microbiology 2024Quote: ... A total of 10 μl of the cell suspension was then loaded into a 1mm diameter glass capillary needle (World Precision Instruments Inc.) by using a micro loader (Eppendorf AG) ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes were pulled from borosilicate glass (World Precision Instruments) to a resistance of 3-5 MΩ using a vertical pipette puller (Narishige PC-100) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Cell injection was performed using borosilicate needles (1 mm O.D. x 0.75 mm I.D.; World Precision Instruments). Between 100 and 200 cells were injected into the circulation of each fish (Duct of Cuvier ...
-
bioRxiv - Biophysics 2024Quote: ... Micropipettes were prepared from 1.5 mm thin-walled glass (World Precision Instruments) using a P97 microelectrode puller (Sutter Instruments) ...
-
bioRxiv - Bioengineering 2024Quote: ... was then used to inject the protein dye near the interface of the hydrogel casted within a 3-inch open-ended glass capillary (1B120-3: World Precision Instruments), ensuring all the air bubbles are extracted prior to experiments ...
-
bioRxiv - Bioengineering 2024Quote: ... The connection points were then encapsulated in a soft silicone (Kwik-Sil, World Precision Instruments). Lastly ...
-
bioRxiv - Bioengineering 2024Quote: Molds for the device assembly were fabricated using PDMS and biopsy punches of 4 mm and 7 mm diameters (World Precision Instruments, Sarasota, FL). A large well was made in the PDMS with the 7 mm punch ...
-
bioRxiv - Neuroscience 2024Quote: ... glued (VetBond, WPI) and cemented to the skull over the parietal and interparietal bone ...
-
bioRxiv - Neuroscience 2024Quote: ... and viruses were infused into the target sites using a glass capillary attached to a microinjection pump (WPI, UMP3T). 100 nL of AAVs or 500 nL of EnvA-pseudotyped RABV were infused at a rate of 1.6 nL/s ...
-
bioRxiv - Neuroscience 2024Quote: ... All infusions were performed using a 10-μL stereotactic syringe attached to a micro-infusion pump (World Precision Instruments) at a rate of 0.1-0.4 μL/min ...
-
bioRxiv - Developmental Biology 2024Quote: ... using a hand pulled borosilicate glass capillary pipette (World Precision Instruments, WPI) as a mouth pipette ...
-
bioRxiv - Developmental Biology 2024Quote: ... Machine pulled borosilicate glass capillary needles were made fresh every week (World Precision Instruments, WPI ...
-
bioRxiv - Developmental Biology 2024Quote: ... Machine pulled borosilicate glass capillary needles were made fresh every week (World Precision Instruments, WPI; Sutter Instruments ...
-
bioRxiv - Cell Biology 2024Quote: ... Briefly 0.1 to 0.2 x 106 cells were seeded in 2 ml of medium in 6-well dishes or 3cm glass- bottomed microscope dishes (World Precision Instruments) or 0.04 x 106 cells were seeded in 300µl of medium in chambers of an 8-well microscopy slide (Ibidi ...
-
bioRxiv - Physiology 2024Quote: ... The TEER was measured using STX-2 chopstick electrodes connected to an EVOM voltohmmeter (World Precision Instruments). 1 mg/ml 4 kDa fluorescein (FITC)-dextran was added to the apical (‘luminal’ ...
-
bioRxiv - Developmental Biology 2024Quote: ... TEER was measured under a sterile hood with a Chopstick electrode and an epithelial voltammeter (EVOM2) (World Precision Instruments, Sarasota, FL). Each well was measured in triplicate and values were averaged ...
-
bioRxiv - Physiology 2024Quote: ... Mouse temperature was monitored by rectal probe and maintained at 37°C through automated warming using a controlled warming pad (ATCC 2000, World Precision Instruments, Sarasota, FL). Anesthetic plane was assessed by respiratory rate and toe pinch reflex ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipette electrodes with a tip resistance between 4 and 6 MΩ were pulled from thin-walled borosilicate glass capillaries (World Precision Instruments, Sarasota, FL) using a P-97 Flaming/Brown Puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipette electrodes with a tip resistance between 10 and 14 MΩ for cones and 6-8 for horizontal cells were pulled from thick-walled borosilicate glass (1.5 mm outer diameter; 0.84 mm inner diameter; World Precision Instruments).
-
bioRxiv - Biophysics 2024Quote: ... Macrophages were fixed with paraformaldehyde and were placed on a FluoroDish (WPI FD35-100) and immersed in PBS.
-
bioRxiv - Biophysics 2024Quote: We prefilled the nanopipette with the amino acid or peptide solution using a Microfil flexible needle (World Precision Instruments) before mounting the nanopipette inserting them into the mass spectrometer ...
-
bioRxiv - Bioengineering 2024Quote: ... The STX4 EVOM™ ELECTRODE (World Precision Instruments, EVM-EL-03-03-01) served as the electrode for the measurements ...
-
bioRxiv - Neuroscience 2024Quote: ... the 5-V trigger is sent to a picopump (WPI, PV830) connected to a 2-mm diameter plastic tube that terminates in a glass capillary to deliver pressurized air to the mouse whiskers.
-
bioRxiv - Neuroscience 2024Quote: ... positioned in the stratum radiatum near the patched cell (<200µm) via a stimulus isolator (WPI #A365). Stimulation intensity was set such as to elicit an evoked excitatory postsynaptic current (eEPSC ...
-
bioRxiv - Neuroscience 2024Quote: ... and a 10 μL Hamilton syringe controlled by an injection pump (WPI). For all surgeries ...
-
bioRxiv - Neuroscience 2024Quote: ... A craniotomy was drilled above the motor cortex using a dental drill (OmniDrill35, 503599, World Precision Instruments; burr drill bit ...
-
bioRxiv - Neuroscience 2024Quote: ... Monosynaptic EPSPs were elicited by stimulation of cortical afferences with a tungsten concentric bipolar electrode (World Precision Instruments). LTP was induced using a theta burst stimulation (TBS ...
-
bioRxiv - Neuroscience 2024Quote: ... Viral particles were delivered using handmade 30g metal injectors connected to a 2µL syringe (Hamilton) with polyethylene tubing and delivered via pump (WPI microinjection syringe pump) at 100nL/min ...
-
bioRxiv - Neuroscience 2024Quote: ... to unilaterally lesioned dopamine neurons (using a 10 μL NanoFil syringe [WPI, Sarasota ...
-
bioRxiv - Neuroscience 2024Quote: For in-vivo electrophysiological experiments, mice were anesthetized with ketamine (100 mg/kg, i.p.) and placed in a stereotaxic device (WPI, Sarasota, FL, USA). In all surgical preparations ...
-
bioRxiv - Neuroscience 2024Quote: ... to unilaterally lesioned dopamine neurons (using a 10 μL NanoFil syringe [WPI, Sarasota, FL, USA] connected to an automated pump at 80 nL/min [UltraMicroPump and SYS-Micro4 Controller, WPI, Sarasota, FL, USA]) in the MFB [anteroposterior (AP) ...
-
bioRxiv - Neuroscience 2024Quote: ... and a microinjection syringe pump (UMP3T-2 World Precision Instruments). Animals received 250 µL of saline for post-surgery hydration.
-
bioRxiv - Neuroscience 2024Quote: ... Whole-cell recordings were performed using borosilicate glass patch electrodes (3-6 MΩ; World Precision Instruments, Florida) pulled on a Narishige PC-10 pipette puller (Narishige ...