Labshake search
Citations for Illumina :
251 - 300 of 9158 citations for Cortisol ELISA Kit 5 Whole Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2023Quote: Libraries were then prepared for deep sequencing using the Nextera XT DNA Library Prep kit in a 96-well plate format (Illumina). Manufacturer’s instructions were followed for each step ...
-
bioRxiv - Cell Biology 2020Quote: ... cDNA was tagmented in 5 technical replicates of 1 ng cDNA each using the Nextera XT Kit (Illumina), according to manufacturer’s instructions ...
-
bioRxiv - Immunology 2021Quote: ... and 5’-end RNA-seq library preparation using tagmentation-based modified Nextera XT DNA sample Preparation kit (Illumina). Libraries were tagged with a plate-specific i7 index and were pooled for sequencing on an Illumina NextSeq2000 platform ...
-
bioRxiv - Cancer Biology 2022Quote: ... and 5’-end RNA-seq library preparation using tagmentation-based modified Nextera XT DNA sample Preparation kit (Illumina). Libraries were tagged with a plate-specific i7 index and were pooled by batches of 4-9 plates for sequencing on an Illumina NextSeq550 platform ...
-
bioRxiv - Microbiology 2021Quote: ... 5 ng of DNA was used as input to create Illumina sequencing libraries using the Nextera kit (Illumina). The samples were pooled and sequenced on an Illumina NextSeq 500 High Output system to obtain 2×150 bp reads ...
-
bioRxiv - Plant Biology 2020Quote: ... custom adapters for selecting 5’-P mRNAs and primers from the TruSeq Small RNA Sample Preparation Kit (Illumina) for multiplexing the libraries as indicated in Zhai et al (2014) ...
-
bioRxiv - Cell Biology 2020Quote: ... 5 μl Tagment DNA Enzyme and 20 μl nuclease free water (Nextera DNA Sample Preparation Kit, Illumina, UK) for 45 min at 37°C ...
-
bioRxiv - Microbiology 2021Quote: ... Amplicon libraries were mixed with 5% PhiX and sequenced with four MiSeq reagent kits v2 500 cycles (Illumina). A blank extraction kit control ...
-
bioRxiv - Cancer Biology 2019Quote: ... the Midi plate from Illumina’s Rapid Capture Exome kit was replaced with a skirted PCR plate to facilitate automation ...
-
bioRxiv - Cancer Biology 2019Quote: ... the Midi plate from Illumina’s Nextera Exome Kit was replaced with a skirted PCR plate to facilitate automation ...
-
bioRxiv - Microbiology 2021Quote: ... according to the manufacturer’s instructions and whole-genome sequencing was performed on an in-house MiSeq platform (Illumina). For long-read sequencing ...
-
bioRxiv - Developmental Biology 2020Quote: ... Whole-genome 2X100 bp or 2X150 bp paired-end sequencing was performed on HiSeq_2500 or Novaseq 6000 (Illumina). Supplemental Table S1 provides basic sequencing statistics for all samples used in this study.
-
bioRxiv - Microbiology 2020Quote: ... Libraries were subjected to whole-genome sequencing using an Illumina® MiSeq benchtop devise (Illumina, San Diego, CA) in paired-end mode (v3 chemistry ...
-
bioRxiv - Genetics 2019Quote: The whole genome genotyping was performed on 80 ovine genomic DNA using the OvineSNP50 Genotyping Beadchip from Illumina according to the manufacturer’s protocol at the Laboratoire d’Analyses Génétiques pour les Espèces Animales ...
-
bioRxiv - Plant Biology 2021Quote: ... and the whole transcriptomes were sequenced using the 100 bp paired-end mode on a HiSeq 2500 (Illumina). The raw read files are deposited as PRJNA742033 in NCBI.
-
bioRxiv - Microbiology 2021Quote: Whole-genome sequencing (WGS) of 31 EIEC strains used in a previous study (26) was performed by Illumina NextSeq (Illumina ...
-
bioRxiv - Microbiology 2022Quote: ... Whole-genome sequencing was performed using a next-generation sequencer (MiSeq system; Illumina Inc., San Diego, CA, USA). The obtained NGS reads were mapped to the SARS-CoV-2 Wuhan-Hu-1 reference genome sequence (29.9 kb single-strand RNA ...
-
bioRxiv - Molecular Biology 2023Quote: ... minus (Table 1) was used for whole-genome sequencing using Illumina short-read sequencing technology (Illumina, California, USA). Paired-end libraries with insert sizes of 327–353 bp were sequenced on a NovaSeq 6000 system (Illumina).
-
bioRxiv - Microbiology 2023Quote: All DH10B transconjugants used as donors were also verified by whole-genome sequencing (Illumina paired-end 300bp reads), to verify that only the target plasmid and no other MGEs were transferred ...
-
bioRxiv - Genomics 2023Quote: The list of the 100 publicly available ovine whole genome sequences (WGS, short read Illumina HiSeq/Nova Seq) coming from 14 different breeds generated in various INRAE and Teagasc research projects is detailed in Table S1 (project and sample accession numbers) ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... Whole genome sequencing was performed on Illumina HiSeq 4000 or Illumina Novaseq 6000 platforms (Illumina, San Diego, CA) with generation of 150 bp paired-end reads.
-
bioRxiv - Microbiology 2023Quote: We performed whole-genome sequencing (WGS) of the 158 barcoded strains used in our study (200 Mbp Illumina DNA sequencing ...
-
bioRxiv - Genetics 2023Quote: We analyzed the whole genome sequences of 1,869 cattle from more than 70 different breeds generated by Illumina technology (Supplementary Table 14) ...
-
bioRxiv - Genomics 2021Quote: ... Libraries were generated from 2-5 μg of genomic DNA using the TruSeq 2 library preparation kit (Illumina, USA). Two types of libraries were prepared ...
-
bioRxiv - Genomics 2020Quote: ... Sequencing libraries were prepared according to the TruSeq stranded mRNA library preparation kit (Illumina, Inc., Cat No.20020594/5) including poly-A selection ...
-
bioRxiv - Systems Biology 2021Quote: ... 5 µg fragmented RNA was used for ribosomal RNA removal using Ribo-Zero Gold rRNA Removal Kit (MRZG12324 Illumina) according to Illumina’s protocol for TruSeq Ribo Profile Kit (RPHMR12126 ...
-
bioRxiv - Developmental Biology 2021Quote: ... Dual indexed sequencing libraries were made out of 5 ng cDNA from the above preparations using Illumina Nextera library preparation kit according to manufacturer’s instructions (Illumina). Quality checked and equimolar pooled libraries were sequenced in a HiSeq 4000 Illumina system ...
-
bioRxiv - Cell Biology 2020Quote: ... rRNA was depleted from 5 μg of total RNA using the Ribo-Zero Gold Yeast rRNA Removal Kit (Illumina) according to the manufacturer’s protocol ...
-
bioRxiv - Genomics 2019Quote: ... Ribosomal RNA (rRNA) was depleted from 5 ug of total RNA using the Ribo-ZeroTM Gold Kit (Illumina, Inc). Depleted mRNA was fragmented and converted to first-strand cDNA using Superscript III reverse transcriptase (Invitrogen) ...
-
bioRxiv - Cell Biology 2020Quote: ... Whole genome sequencing was performed with 1 μg of the digested DNA using a HiSeq X Ten Sequencer (Illumina) at Macrogen (South Korea).
-
bioRxiv - Evolutionary Biology 2019Quote: ... (Sacramento, CA) for whole-genome 150 bp paired-end sequencing on a NovaSeq 6000 (Illumina Inc., San Diego, CA). Between 59,765,048 and 74,464,410 paired reads were obtained for each sample ...
-
bioRxiv - Neuroscience 2020Quote: ... nDNA was extracted from whole blood and genotyped on Illumina GWAS arrays for ADNI1 (Illumina Human 610-Quad BeadChip), ADNI GO/2 participants (Illumina HumanOmniExpress BeadChip) ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... The whole genome (WGS) for each pool was sequenced in a Miseq platform (Illumina, Inc., San Diego, CA, USA) at the Molecular and Cellular Imaging Center at the Ohio State University.
-
bioRxiv - Microbiology 2020Quote: ... whole-genome sequencing was carried out using the Illumina HiSeq2500 genome analyser (Illumina HiSeq 2500 platform, Illumina, Essex, UK). The reads were assembled to contigs using SPAdes.
-
bioRxiv - Evolutionary Biology 2021Quote: ... the strains were previously subjected to whole-genome shotgun sequencing using 2×250bp Illumina paired-end reads (Illumina, USA). Genomes were assembled using SPAdes (v ...
-
bioRxiv - Evolutionary Biology 2021Quote: We genotyped all individuals from the central transect for a selection of 1,152 SNPs spread across the whole genome using the GoldenGate assay (Illumina). A detailed description of the assay design ...
-
bioRxiv - Genomics 2022Quote: ... Whole genome sequencing (WGS) of the prepared libraries was performed through Illumina MiSeq sequencer (Illumina, San Diego, CA, USA) using a 2 × 250 paired-end protocol.
-
bioRxiv - Microbiology 2022Quote: ... Whole genome DNA was paired-end sequenced (2 × 150 bp) using Illumina NovaSeq 6000 (Illumina, San Diego, CA, USA) at Shanghai Personal Biotechnology Co. ...
-
bioRxiv - Microbiology 2022Quote: Library for whole genome sequencing was prepared using Nextera™ DNA Flex Library Prep (Illumina; San Diego, CA, USA) as per the recommended protocol ...
-
bioRxiv - Microbiology 2022Quote: ... Paired-end sequencing (2×150 bp) and PCR-free whole genome sequencing was performed on a HiSeq X (Illumina) 54 ...
-
bioRxiv - Microbiology 2023Quote: ... and the samples were subjected to Illumina-based whole-genome sequencing using a MiSeq 250 paired-end run (Illumina). CLC Genomics Workbench (Qiagen ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... (2022) sequenced 20 vaquita porpoise (Phocoena sinus) whole genomes from the Gulf of California to 60x coverage (Illumina HiSeqX). They mapped reads to the vaquita reference genome (mPhoSin1.pri ...
-
bioRxiv - Cancer Biology 2023Quote: ... samples were sequenced for low-pass whole genome sequencing with at least 0.1X coverage in a NovaSeq 6000 (Illumina).
-
bioRxiv - Immunology 2020Quote: ... 0.1 ng of cDNA from each cell on the plate was individually tagmented using the Nextera XT kit (Illumina, San Diego, CA) in a final volume of 5 µl ...
-
bioRxiv - Microbiology 2021Quote: PCR free shotgun libraries were prepared for each sample from 2.5 ug metagenomic DNAs by Exeter Sequencing Service for the metagenomic sequencing using the TruSeq DNA library Prep Kit (Illumina). The libraries were sequenced to approximately 7GBp using the HiSeq 2500 rapid run mode (2X 250 bp paired end ...
-
bioRxiv - Genetics 2020Quote: ChIP-seq and DNase-seq libraries were prepared from 1-5 ng ChIP DNA or DNase DNA samples using NEBNext Ultra II DNA library Prep Kit (Illumina). Libraries were sequenced on an Illumina NextSeq 500 with single-end or paired-end 75 bp reads.
-
bioRxiv - Immunology 2019Quote: ... and a mixture of 8 VH family and IgM-specific primers (listed below) containing 5’ adaptors to allow barcoding by the Illlumina TruSeq multiplex pcr kit (Illumina). Resulting PCR products were subjected to 10 cycles of PCR using Illumina TruSeq indexing primers ...
-
bioRxiv - Genomics 2019Quote: ... and three mate-pair libraries (insert sizes of 2 kb, 5 kb, and 8 kb) were constructed using the TruSeq PCR-free Kit (Illumina) and Mate-pair Kit (Illumina) ...
-
bioRxiv - Microbiology 2021Quote: ... 50 ng of each amplicon was dual indexed in a 5-cycle PCR reaction using the PCR module and indexed primers from the Nextera kit (Illumina). Resulting libraries were purified on AMPure XP magnetic beads (Beckman Coulter ...
-
bioRxiv - Immunology 2020Quote: ... Use of 250 pg of cDNA with 1/5 reaction of Illumina Nextera XT kit (Illumina, San Diego, CA, USA). The length distribution of the cDNA libraries was monitored using DNA High Sensitivity Reagent Kit on the Perkin Elmer Labchip GX system (PerkinElmer ...