Labshake search
Citations for Illumina :
101 - 150 of 2597 citations for 8 Chloro 1 2 3 4 tetrahydro 1 4 methylphenyl sulfonyl 5H 1 benzazepin 5 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... The V3-V4 region of the 16S ribosomal RNA gene was amplified by PCR with universal bacterial primer sets (5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATCC-3’) and was sequenced using MiSeq Reagent kit v3 (600 cycle) (Illumina Inc., California, US). The sequence data were analyzed using QIIME2 (https://qiime2.org/ ...
-
bioRxiv - Microbiology 2022Quote: ... diluted at a ratio of 1:2 and amplified following the Nextera XT Index protocol (Illumina, Inc.). The amplicons were normalized using a SequalPrep™ Normalization Plate Kit (Thermo Fisher Scientific Inc. ...
-
bioRxiv - Cell Biology 2020Quote: ... cDNA was tagmented in 5 technical replicates of 1 ng cDNA each using the Nextera XT Kit (Illumina), according to manufacturer’s instructions ...
-
bioRxiv - Immunology 2021Quote: ... Cells were then lysed and fragmented in a single reaction (12.5 µl 2X Illumina TDE buffer, 2.5 µl 1% Tween-20, 2.5 µl 0.2% Digitonin, 5 µl water, 2.5 µl Illumina TDE1 enzyme). Samples were incubated at 37°C for 60 minutes and purified using the Zymo DNA Clean and Concentrator-5 Kit (Zymo) ...
-
bioRxiv - Microbiology 2022Quote: ... 2.5 µL primer P5 (5 µM) and 2.5 µL Index 1 primer (N7**, Illumina, CN FC-131-2001) was used for the PCR enrichment ...
-
bioRxiv - Microbiology 2023Quote: ... 1 μl of forward and 1 μl of reverse 25 μM PCR primers (Illumina), and 0.5 μl of Phusion high-fidelity DNA polymerase (New England Biolabs) ...
-
bioRxiv - Neuroscience 2023Quote: ... collected with the magnet and resuspended in 24ul of Tagmentation Mix (1:1 Illumina 2× Tagmentation buffer ...
-
bioRxiv - Microbiology 2023Quote: ... The prepared library was sequenced using a MiSeq sequencing system with a V3 reagent kit (300 × 2 bp; Illumina, 4–6 samples). Lake Biwa viral contigs/genomes (LBVs ...
-
bioRxiv - Microbiology 2023Quote: ... 2 μl of the v1.5 sRNA 3’ adapter (Illumina) was mixed with the 14 μl eluate of the previous step in a 200 μl nuclease-free ...
-
bioRxiv - Developmental Biology 2024Quote: ... Amplification was carried out using 3 µl of NMP per sample and adding 1 µl of each dual-indexed (i7 and i5; Illumina) primer ...
-
bioRxiv - Molecular Biology 2024Quote: ... CUT&RUN libraries (10–20 Mio reads per sample and 1/3 of reads for the controls) were sequenced on a NovaSeq 6000 (Illumina) paired end 100 bp at the Deep Sequencing Facility (Max Planck Institute for Immunobiology and Epigenetics ...
-
bioRxiv - Genetics 2019Quote: ... 1% PhyX spike-in (Illumina) was included ...
-
bioRxiv - Immunology 2021Quote: ... Group 1 (The Netherlands, Illumina), Group 2 (France ...
-
bioRxiv - Microbiology 2021Quote: ... 1×75 cycles (Illumina, USA). Image analysis was performed in real time by the NextSeq Control Software and Real Time Analysis running on the instrument computer ...
-
bioRxiv - Systems Biology 2022Quote: ... 1% PhyX spike-in (Illumina) was added then pooled ...
-
bioRxiv - Cancer Biology 2021Quote: ... Libraries were sequenced 2 * 50+8+16 bp on a HiSeq2500 sequencer (Illumina). RNA-seq data were processed according to Doyle et al ...
-
bioRxiv - Genetics 2020Quote: ... Pooled and denatured library (8 pM) containing 5% volume of PhiX (control library; Illumina) was sequenced using the Illumina MiSeq system with MiSeq Reagent Kit V3 (300-bp paired-end reads ...
-
bioRxiv - Microbiology 2019Quote: ... The qPCR efficiency of the assay was calculated (FIG 2) using the following formula: Efficiency = 10[-1/Slope] (http://efficiency.gene-quantification.info/) by Illumina Eco Real-Time PCR system software ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 2 µl aliquot of the denatured library pool is then added to 1 ml of HT1 (Illumina), mixed and 120 µl is added to the ‘sample library’ cBot strip tube ...
-
bioRxiv - Cancer Biology 2020Quote: ... and loaded at 4 nM into the MiSeq sequencer (Illumina) v3 chemistry kit spiked with 10% PhiX genome ...
-
bioRxiv - Immunology 2023Quote: ... or the NovaSeq XP 4-Lane Kit v1.5 (Illumina, 20043131).
-
bioRxiv - Genetics 2019Quote: ... We tagmented 5 ng of cDNA using 1 uL Nextera Tagment DNA Tn5 transposase (Illumina, San Diego, CA, 15027916) in a 10 uL tagmentation mix for 10 minutes at 55 °C.
-
bioRxiv - Molecular Biology 2022Quote: ... The chromatin was then tagmented by resuspending beads in 29 µl Tagmentation Buffer (10 mM Tris-HCl pH 8.0, 5 mM MgCl2, 10% dimethylformamide) and adding 1 µl of transposase (Illumina). Samples were incubated at 37 °C for 10 min and the reaction was terminated by adding 150 µl RIPA buffer ...
-
bioRxiv - Genomics 2022Quote: ... spun at 300G for 12 min at 4 ºC and resuspended in 20 uL transposition mix: 1X TD buffer and 2 uL of TDE1 (Illumina #FC-121-1030), 0.01% Digitonin in DMSO ...
-
bioRxiv - Cell Biology 2022Quote: ... a PCR enrichment step was performed (8 cycles) using unique primer pairs for each library (NEBNext Multiplex Oligos for Illumina-Dual Index Primers Set 1).
-
bioRxiv - Genomics 2024Quote: ... Miniaturization involved testing libraries at 1/6th (IDT mini) or 1/8th (Roche mini, Illumina mini) of reaction volume tailoring input DNA to each kit between 24-45 ng total (Table 2) ...
-
bioRxiv - Systems Biology 2020Quote: ... i7 index 8 cycles and Read 2 56 cycles on a NextSeq500 instrument (Illumina) using High Output v2.1 chemistry ...
-
bioRxiv - Cancer Biology 2019Quote: ... Sequencing was performed on an Illumina NovaSeq platform (paired-end, Read 1: 26 cycles and Read 2: 98 cycles) according to the manufacturer’s instructions (Illumina).
-
bioRxiv - Molecular Biology 2019Quote: ... Initial RNA-seq libraries were made using the TruSeq RNA prep kit by Illumina (shW, shSv210-1, shSv210-2). A second set of libraries from shW ...
-
bioRxiv - Cancer Biology 2021Quote: ... adding Illumina sequencing adapters and dual-index barcodes (index 1(i7) and index 2(i5)) (Illumina, San Diego, CA) to the amplicon target ...
-
bioRxiv - Immunology 2023Quote: ... The samples were sequenced in a paired-end run (read 1: 28bp, read 2: 91bp) on a NovaSeq6000 platform using S1 v1.5 (100 cycles) sequencing kits (Illumina). Bcl2fastq software (v2.20.0.422 ...
-
bioRxiv - Neuroscience 2021Quote: ... 1 μtagment DNA enzyme (Nextera, Illumina), l nuclease free water ...
-
bioRxiv - Genetics 2019Quote: ... supplemented with 1 μl Tn5 (Illumina). Samples were then reverse cross-linked using the iDeal® ChIP-seq kit for histones according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2021Quote: ... 1 μl of transposase (Nextera, Illumina) was added and samples were incubated at 37°C for 10 minutes followed by two washes with low-salt buffer ...
-
bioRxiv - Genetics 2020Quote: ChIP-seq and DNase-seq libraries were prepared from 1-5 ng ChIP DNA or DNase DNA samples using NEBNext Ultra II DNA library Prep Kit (Illumina). Libraries were sequenced on an Illumina NextSeq 500 with single-end or paired-end 75 bp reads.
-
bioRxiv - Genomics 2021Quote: ... Following immunoprecipitation with Dynabeads Protein G beads (invitrogen) in PCR tubes, samples were subject to Tagmentation (5 µl Tagmentation Buffer, 1 µl Tagmentation DNA Enzyme (Illumina), 19 µl Nuclease free water ...
-
bioRxiv - Systems Biology 2020Quote: ... Sequencing was performed using custom read primer oligo1210 (5’-CTTGTGGAAAGGACGAAACACCGGTAATTTCTACTCTTGTAGAT) (HPLC purified, Integrated DNA Technologies) using NextSeq 1 × 75 nt High Output reagents (Illumina).
-
bioRxiv - Immunology 2020Quote: ... Use of 250 pg of cDNA with 1/5 reaction of Illumina Nextera XT kit (Illumina, San Diego, CA, USA). The length distribution of the cDNA libraries was monitored using DNA High Sensitivity Reagent Kit on the Perkin Elmer Labchip GX system (PerkinElmer ...
-
bioRxiv - Genomics 2019Quote: ... 5 mM MgCl2) containing 1 μl Tn5 transposase from the Nextera DNA Library Prep Kit (15028212, Illumina, San Diego, USA) and incubated at 37°C for 10min ...
-
bioRxiv - Genetics 2021Quote: ... The bone and reference captured library pools were diluted to 1 pM with a 5% spike-in of PhiX Control V3 (Illumina) for sequencing on a NextSeq 550 (Illumina ...
-
bioRxiv - Cancer Biology 2023Quote: RNA-seq libraries were prepared with 0,5-1 µg of total high quality RNA collected from samples and the Illumina Stranded Total RNA Prep kit (Illumina) according to manufacturer’s instructions ...
-
bioRxiv - Immunology 2024Quote: ... the antibody barcode library was pooled at a ratio of 1:5 with the gene expression library and sequenced on a NextSeq 2000 (Illumina) to an average depth of 34,000 reads per cell.
-
bioRxiv - Evolutionary Biology 2023Quote: ... The library was pooled with other samples at equimolar concentrations and sequenced at 4 nM as single lanes on Illumina NovaSeq 6000 S4 platform (2×150; Illumina Inc., San Diego, CA). The library for long-read data was prepared using the Nanopore ligation kit ...
-
bioRxiv - Microbiology 2021Quote: ... 5 in treatment d28_0 and 5 from d28_100 (Illumina HiSeq, 2×150bp, GenoScreen, France). Reads corresponding to animal sequences were identified by aligning each dataset against Oryzias latipes available at the NCBI ...
-
bioRxiv - Genomics 2022Quote: ... The library was run across 4 lanes of a NovaSeq (Illumina), multiplexed with other samples.
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA depletion with additional probes recommended by Illumina (Table 4), stranded library preparation (Illumina Ribo-Zero Plus rRNA Depletion w/ Stranded Total RNA) ...
-
bioRxiv - Genomics 2023Quote: ... Libraries were prepared using the QuantSeq 3’ mRNA-Seq Library Prep Kit FWD for Illumina and UMI Second Strand Synthesis Module for QuantSeq FWD (Illumina, Read 1) from Lexogen (015.96 and 081.96 ...
-
bioRxiv - Immunology 2020Quote: ... cells were lysed in lysis buffer for 1 minute and transposed with Tagment DNA Enzyme 1 (Illumina) for 30 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... for each sample 2 μl of 5’ adapter (Illumina) (total 12 μl ...
-
bioRxiv - Genetics 2021Quote: ... Libraries were sequenced by NextSeq 550 High Output with 21 bp for read 1 and 72 bp for read 2 (Illumina). Sequenced reads were aligned using STAR (v2.7.6a ...