Labshake search
Citations for Illumina :
51 - 100 of 1999 citations for 5 Azepane 1 sulfonyl 2 methoxy benzoic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... version 2 (Illumina). Library pools were diluted to 4 nM and denatured into single strands using fresh 0.2 N NaOH ...
-
bioRxiv - Cell Biology 2022Quote: ... version 2 (Illumina) using 10 PCR cycles ...
-
bioRxiv - Cancer Biology 2023Quote: ... Each well contained 5□μL NIB and 5□μL TD buffer from Illumina, and 1 mL of 2.5 mM uniquely indexed transposome ...
-
bioRxiv - Cell Biology 2020Quote: ... cDNA was tagmented in 5 technical replicates of 1 ng cDNA each using the Nextera XT Kit (Illumina), according to manufacturer’s instructions ...
-
bioRxiv - Immunology 2021Quote: ... Cells were then lysed and fragmented in a single reaction (12.5 µl 2X Illumina TDE buffer, 2.5 µl 1% Tween-20, 2.5 µl 0.2% Digitonin, 5 µl water, 2.5 µl Illumina TDE1 enzyme). Samples were incubated at 37°C for 60 minutes and purified using the Zymo DNA Clean and Concentrator-5 Kit (Zymo) ...
-
bioRxiv - Microbiology 2022Quote: ... 2.5 µL primer P5 (5 µM) and 2.5 µL Index 1 primer (N7**, Illumina, CN FC-131-2001) was used for the PCR enrichment ...
-
bioRxiv - Microbiology 2022Quote: ... diluted at a ratio of 1:2 and amplified following the Nextera XT Index protocol (Illumina, Inc.). The amplicons were normalized using a SequalPrep™ Normalization Plate Kit (Thermo Fisher Scientific Inc. ...
-
bioRxiv - Physiology 2021Quote: ... 3’ and 5’ adaptors (Illumina) were ligated and the resulting product was reverse transcribed to generate cDNA by PCR ...
-
bioRxiv - Microbiology 2021Quote: ... 5) DC3000 + C (Illumina only), 6 ...
-
bioRxiv - Immunology 2022Quote: ... and 5 µl Tn5 (Illumina) in nuclease-free water or in 50 µl tagmentation mix “Corces et al ...
-
bioRxiv - Developmental Biology 2020Quote: ... 5 ul TDE1 (Illumina 20034197)) and shaken at 1000 RPM for 30 minutes at 37°C ...
-
bioRxiv - Molecular Biology 2022Quote: ... The chromatin was then tagmented by resuspending beads in 29 µl Tagmentation Buffer (10 mM Tris-HCl pH 8.0, 5 mM MgCl2, 10% dimethylformamide) and adding 1 µl of transposase (Illumina). Samples were incubated at 37 °C for 10 min and the reaction was terminated by adding 150 µl RIPA buffer ...
-
bioRxiv - Neuroscience 2024Quote: ... 5 ul of Tn5 tagmentation mix (1X Tagment DNA buffer, Illumina; ATM mix, Illumina and cDNA library 1 ng) was prepared for cDNA fragmentation ...
-
bioRxiv - Genomics 2020Quote: ... 300×2 bp or 150×2 bp (Illumina, Inc., San Diego, CA).
-
bioRxiv - Biochemistry 2024Quote: Forward Illumina Adapter: 5’-ACACTCTTTCCCTACACGACGCTCTTCCGATCTXXXX-3’ Reverse Illumina Adapter: 5’-GACTGGAGTTCAGACGTGTGCTCTTCCGATCTXXXX-3’ Next generation (Illumina) sequencing was performed by Azenta (Amplicon-EZ) ...
-
bioRxiv - Molecular Biology 2023Quote: ... A 2 µl aliquot of the denatured library pool is then added to 1 ml of HT1 (Illumina), mixed and 120 µl is added to the ‘sample library’ cBot strip tube ...
-
bioRxiv - Plant Biology 2022Quote: ... 2 (Illumina, CA, USA). The two types of libraries ...
-
bioRxiv - Cancer Biology 2020Quote: ... 2 μl transposase (Illumina), 10.5 μl nuclease-free water and 0.01% NP-40 ...
-
bioRxiv - Immunology 2021Quote: ... Group 2 (France, Illumina), Group 3 (North America ...
-
bioRxiv - Microbiology 2022Quote: ... 2 (Illumina, CA, USA). ASVs were inferred using DADA2 v ...
-
bioRxiv - Microbiology 2023Quote: ... and 2 from Illumina libraries.
-
bioRxiv - Genetics 2020Quote: ChIP-seq and DNase-seq libraries were prepared from 1-5 ng ChIP DNA or DNase DNA samples using NEBNext Ultra II DNA library Prep Kit (Illumina). Libraries were sequenced on an Illumina NextSeq 500 with single-end or paired-end 75 bp reads.
-
bioRxiv - Genomics 2021Quote: ... Following immunoprecipitation with Dynabeads Protein G beads (invitrogen) in PCR tubes, samples were subject to Tagmentation (5 µl Tagmentation Buffer, 1 µl Tagmentation DNA Enzyme (Illumina), 19 µl Nuclease free water ...
-
bioRxiv - Systems Biology 2020Quote: ... Sequencing was performed using custom read primer oligo1210 (5’-CTTGTGGAAAGGACGAAACACCGGTAATTTCTACTCTTGTAGAT) (HPLC purified, Integrated DNA Technologies) using NextSeq 1 × 75 nt High Output reagents (Illumina).
-
bioRxiv - Immunology 2020Quote: ... Use of 250 pg of cDNA with 1/5 reaction of Illumina Nextera XT kit (Illumina, San Diego, CA, USA). The length distribution of the cDNA libraries was monitored using DNA High Sensitivity Reagent Kit on the Perkin Elmer Labchip GX system (PerkinElmer ...
-
bioRxiv - Genetics 2021Quote: ... The bone and reference captured library pools were diluted to 1 pM with a 5% spike-in of PhiX Control V3 (Illumina) for sequencing on a NextSeq 550 (Illumina ...
-
bioRxiv - Immunology 2024Quote: ... the antibody barcode library was pooled at a ratio of 1:5 with the gene expression library and sequenced on a NextSeq 2000 (Illumina) to an average depth of 34,000 reads per cell.
-
bioRxiv - Cancer Biology 2023Quote: RNA-seq libraries were prepared with 0,5-1 µg of total high quality RNA collected from samples and the Illumina Stranded Total RNA Prep kit (Illumina) according to manufacturer’s instructions ...
-
bioRxiv - Immunology 2023Quote: ... ADT and 3’ Gexp libraries were mixed at the ratio of 1:5 and sequenced on NovaSeq 6000 sequencer (Illumina) with a configuration of 28/8/0/91-bp for cell barcode ...
-
bioRxiv - Genetics 2022Quote: ... The flow cell was loaded with 5 picomolar pooled libraries containing 5% PhiX control V3 (Illumina). Raw sequencing data were demultiplexed with Bcl2Fastq software (v2.19 ...
-
bioRxiv - Microbiology 2024Quote: ... with 5% PhiX loading control (Illumina).
-
bioRxiv - Genomics 2024Quote: ... with 5% PhiX spike-in (Illumina).
-
bioRxiv - Cancer Biology 2024Quote: ... with 5% PhiX library control (Illumina). Autosmal ranged from 23X to 29X ...
-
bioRxiv - Cancer Biology 2021Quote: ... adding Illumina sequencing adapters and dual-index barcodes (index 1(i7) and index 2(i5)) (Illumina, San Diego, CA) to the amplicon target ...
-
bioRxiv - Immunology 2023Quote: ... The samples were sequenced in a paired-end run (read 1: 28bp, read 2: 91bp) on a NovaSeq6000 platform using S1 v1.5 (100 cycles) sequencing kits (Illumina). Bcl2fastq software (v2.20.0.422 ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... High-throughput genome sequencing was performed either on Hiseq 2000 (2 × 100 or 2 × 150 paired-end reads) or Miseq (2 × 300 paired-end reads) sequencer (Illumina, San Diego, CA) following the manufacturer ‘s instruction.
-
bioRxiv - Physiology 2021Quote: ... High-throughput genome sequencing was performed on a HiSeq 2500 (2 × 100 or 2 × 150 paired-end reads) or MiSeq (2 × 300 paired-end reads) sequencer (Illumina, San Diego, CA), following the manufacturer’s instructions ...
-
bioRxiv - Genomics 2024Quote: ... The 33 samples were combined into 2 pools and sequenced using 2 NovaSeq (Illumina) S4 200 cycle flow cells.
-
bioRxiv - Cancer Biology 2021Quote: ... Each well contained 10 μL tagmentation buffer (5 μL NIB and 5 μL TD buffer from Illumina). For the second sort plate ...
-
bioRxiv - Cell Biology 2020Quote: ... and D (v.2, Illumina) and sequenced on HiSeq4000 and NovaSeq6000 (Illumina ...
-
bioRxiv - Molecular Biology 2022Quote: ... 2 μl Tn5 enzyme (Illumina), 0.25 μl 1 % digitonin ...
-
bioRxiv - Genetics 2023Quote: 2×150bp reads from Illumina NovaSeq were obtained for all samples with a minimum depth of 22M reads at Novogene (Beijing ...
-
bioRxiv - Molecular Biology 2023Quote: ... and 2) Detection from Illumina RNA-seq data through SL leader sequence trimming(43) ...
-
bioRxiv - Genetics 2023Quote: 2×150bp reads from Illumina NovaSeq were obtained for all samples with a minimum depth of 17 M reads at Novogene (Beijing ...
-
bioRxiv - Genetics 2021Quote: ... Libraries were sequenced by NextSeq 550 High Output with 21 bp for read 1 and 72 bp for read 2 (Illumina). Sequenced reads were aligned using STAR (v2.7.6a ...
-
bioRxiv - Microbiology 2020Quote: ... pooled with 1% denatured PhiX DNA (sequencing control) and sequenced in a MiSeq platform (2× 251 cycles paired-end run; Illumina). New PCR reactions using combinations of the primers described above were carried out to cover regions with low coverage for each sample ...
-
bioRxiv - Systems Biology 2020Quote: ... then performed paired-end sequencing of these libraries (38 cycles read 1 + 37 cycles read 2) on a NextSeq 500 (Illumina). After sequencing ...
-
bioRxiv - Cell Biology 2021Quote: ... 8 bases for index 1 and 8 bases for index 2) using the NextSeq 500 High Output Kit 75-cycles (#FC-404-1005, Illumina) loaded at 1.8pM and including 1 % PhiX ...
-
bioRxiv - Molecular Biology 2022Quote: ... followed by library construction using non-stranded (Replicate 1) or stranded (Replicates 2 and 3) TruSeq mRNA Library Prep Kit (Illumina). The resulting libraries were sequenced on Hiseq4000.
-
bioRxiv - Immunology 2022Quote: ... TCRseq libraries were sequenced on an Illumina Novaseq 6000 SP flowcell (67 bp read 1 and 459 bp read 2) (Illumina) to a depth of approximately 20,000 reads.