Labshake search
Citations for Illumina :
751 - 800 of 1444 citations for Exodus 2 CCL21 Mouse since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Libraries were sequenced at low-pass (2x 50bp paired end) targeting 2 million reads on a NextSeq (Illumina) instrument ...
-
bioRxiv - Microbiology 2023Quote: ... The recovered DNA fragments were sequenced using the MiSeq 500PE v.2 kit (Illumina, San Diego, CA, USA). Short-read sequences from each PCR fragment were assembled using Spades v 3.1(31) ...
-
bioRxiv - Cell Biology 2024Quote: ... and a 2 pM solution of this pool was sequenced unidirectionally on a NextSeq® 500 System (Illumina) at GeneCore ...
-
bioRxiv - Immunology 2024Quote: ... Purified RNA was submitted to Azenta Life Sciences/Genewiz for library preparation and sequencing (Illumina HiSeq 2×150bp).
-
bioRxiv - Microbiology 2024Quote: ... and paired-end sequencing (300 bp × 2) on the MiSeq platform with the MiSeq Reagent Kit v3 (Illumina) were conducted as described previously [31] ...
-
bioRxiv - Molecular Biology 2024Quote: ... using a paired-end read length of 2 × 150bp with the HiSeq Reagent Kits (Illumina, San Diego, California) (Cogne et al ...
-
bioRxiv - Plant Biology 2024Quote: ... Amplicons were sequenced (2×250 bp) on a NovaSeq 6000 SP flow cell (Illumina, San Diego, CA, USA). Each “batch” of 96 samples (n=6 ...
-
bioRxiv - Cell Biology 2020Quote: ... cDNA libraries were constructed from individual mouse samples and RNA-seq libraries were constructed using the Nextera XT DNA Library Preparation Kit (Illumina). Libraries were sequenced on the Illumina platform ...
-
bioRxiv - Developmental Biology 2020Quote: ... Ribosomal RNA was removed from 500ng of input RNA using either Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) from Illumina or NEBNext rRNA Depletion Kit (Human/ Mouse/ Rat) ...
-
bioRxiv - Molecular Biology 2022Quote: ... RNA-Seq libraries were made following a standard protocol using Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina) and TruSeq Stranded mRNA Library Prep (Illumina) ...
-
bioRxiv - Molecular Biology 2020Quote: ... Sequencing libraries were generated using the TruSeq Stranded Total RNA with Ribo-Zero Human/ Mouse/Rat Low-throughput (LT) kit (Illumina) and run on a NextSeq 500 for paired-end sequencing using the NextSeq 500/550 High Output v2 Kit ...
-
bioRxiv - Cell Biology 2022Quote: ... libraries were prepared using the TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Kit (cat. RS-122-2201/2202, Illumina) according to the manufacturer’s protocol ...
-
bioRxiv - Genomics 2020Quote: Illumina sequencing libraries of total RNA were prepared using the Illumina TruSeq Stranded Total RNA Human/Mouse/Rat kit (Cat number RS-122-2201) following the protocol provided by Illumina with Ribo-Zero.
-
bioRxiv - Systems Biology 2019Quote: ... was measured using an Agilent Bioanalyzer and samples were ribo-depleted using a using a RiboZero Gold (Human/Mouse/Rat) kit (Illumina) to remove rRNAs ...
-
bioRxiv - Molecular Biology 2019Quote: ... 1 µg of input RNA was used for rRNA removal with Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat) (Illumina). Libraries were generated with the NEBNext Ultra Directional RNA Library Prep kit for Illumina (NEB ...
-
bioRxiv - Cancer Biology 2020Quote: ... Libraries were prepared from 1 μg of total RNA using a TruSeq Stranded Total RNA Kit with Ribo-Zero Human/Mouse/Rat (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2021Quote: ... RNAseq reads were aligned against to Ensembl Mouse genome (NCBIM37) reference sequence assembly and transcript annotation that obtained from Illumina iGenomes (https://support.illumina.com/sequencing/sequencing_software/igenome.html ...
-
The RNA-Binding Protein SAM68 regulates cardiomyocyte differentiation by enhancing Gata4 translationbioRxiv - Molecular Biology 2022Quote: ... rRNA depletion and library preparation was done with the TruSeq stranded total RNA Library prer Human/Mouse/Rat (20020596, Illumina). The sequencing was performed using 2×125bp paired-ends reads on a HiSeq 2500 sequencer with HiSeq v4 chemistry ...
-
bioRxiv - Biochemistry 2022Quote: ... Raw sequencing reads were aligned to the mouse genome (mm9) and the corresponding GTF file (downloaded from Illumina’s IGenomes site) using TopHat v.2.1.1 with parameters i= 30 ...
-
bioRxiv - Cancer Biology 2022Quote: ... Libraries were generated from 1 μg of total RNA using a TruSeq Stranded Total RNA Library Prep Human/Mouse/Rat (48 Samples) (Illumina) per manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2022Quote: ... RNA-seq libraries were prepared using the TruSeq Stranded Total RNA LT Sample Prep Kit with Ribo-Zero Human/Mouse/Rat (Illumina). We generated biological triplicate data for 1T47 ...
-
bioRxiv - Genomics 2019Quote: ... cDNA libraries were constructed using Illumina TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Set B (Illumina) to deplete ribosomal RNA according to the manufacturer’s instruction ...
-
bioRxiv - Genomics 2019Quote: ... The Agilent 2100 Bioanalyzer was used to assess RNA quality and only high quality RNA (RIN > 8) was further processed for removal of ribosomal RNA with the Ribo-Zero Magnetic Gold Kit (Human/Mouse/Rat; Illumina). Ribosomal-depleted RNA was used as input for library preparation with Illumina TruSeq V2 RNA prep kit and processed according to the manufacturer’s instruction ...
-
bioRxiv - Molecular Biology 2020Quote: ... RNA-seq for the mouse heart tissues were performed using next generation high throughput sequencing method (Illumina HiSeq 2000, Illumina). Total RNAs were isolated ...
-
bioRxiv - Molecular Biology 2020Quote: ... RNA-seq for the mouse heart tissues were performed using next generation high throughput sequencing method (Illumina HiSeq 2000, Illumina). Total RNAs were isolated ...
-
bioRxiv - Molecular Biology 2021Quote: ... 10 μg chromatin-associated RNAs were depleted of ribosomal RNA depletion using Ribo-Zero Magnetic Gold Kit (human/mouse/rat; Illumina), according to the manufacturer’s instruction ...
-
bioRxiv - Molecular Biology 2021Quote: ... 10 μg chromatin-associated RNAs were depleted of ribosomal RNA depletion using Ribo-Zero Magnetic Gold Kit (human/mouse/rat; Illumina), according to the manufacturer’s instruction ...
-
bioRxiv - Genomics 2021Quote: ... rRNA was removed and total RNA library was prepared with TruSeq Stranded Total RNA Library Prep Human/Mouse/Rat (Illumina) and sequenced by Illumina platform HiSeq2500 Paired-end 125 bp.
-
bioRxiv - Physiology 2021Quote: Sodium-bisulfite treated DNA of nine samples (6 dHT vehicle treated and 3 dHT drug treated) was subjected to measure global DNAm by Infinium Mouse methylation BeadChip array (Illumina) according to manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2021Quote: ... rRNA was depleted using Ribo-Zero™ Magnetic Gold Kit for rRNA depletion (Human/Mouse/Rat) (Epicentre for Illumina #MRZG12324) according to manufacturer’s guidelines ...
-
bioRxiv - Genomics 2020Quote: RNA from a subset of human fetal (n = 3) and mouse (n = 8) cortex tissue samples was prepared with TruSeq Stranded mRNA Sample Prep Kit (Illumina) and subjected to 125bp paired-end sequencing using a HiSeq2500 (Illumina) ...
-
bioRxiv - Microbiology 2020Quote: ... ribosomal RNA (rRNA) was depleted from the total RNA extracts using the Ribo-Zero Gold (human-mouse-rat) kit (Illumina) following the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... rRNA was removed using Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat) and Ribo-Zero rRNA Removal Kit (Bacteria) (Illumina). In order to reduce the impact of the host transcriptome on subsequent analysis ...
-
bioRxiv - Molecular Biology 2021Quote: ... Sequencing libraries were generated using the TruSeq Stranded Total RNA with Ribo-Zero Human/ Mouse/Rat Low-throughput (LT) kit (Illumina) and run on a NextSeq 500 for paired-end sequencing using the NextSeq 500/550 High Output v2 Kit ...
-
bioRxiv - Neuroscience 2022Quote: ... Both samples (footprints and total mRNA) went through a ribosomal RNA removal step using the Ribo-Zero Gold (Human/Mouse/Rat) Kit (Illumina). The footprint samples were then purified on a 15% TBE-Urea polyacrylamide gel (ThermoFisher Scientific ...
-
bioRxiv - Physiology 2022Quote: ... one microgram of total RNA was used to construct cDNA libraries with the TruSeq Stranded Total RNA with Ribo-Zero Gold Human/Mouse/Rat kit (Illumina). Sequencing was performed using Illumina NovaSeq 6000 (coverage - 50 x ...
-
bioRxiv - Molecular Biology 2022Quote: ... rRNA was depleted from total RNA using the Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat) (Illumina, San Diego, CA) to enrich for coding RNA and long non-coding RNA ...
-
bioRxiv - Molecular Biology 2022Quote: Total RNA libraries were prepared using the TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Kit (REF. RS-122-2201/2202, Illumina) according to the manufacturer’s protocol ...
-
bioRxiv - Molecular Biology 2024Quote: ... RNA was extracted with a Direct-zol RNA MicroPrep Kit and subjected to an RNA-Seq library preparation using a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina) followed by a TruSeq Stranded Total RNA Kit (Illumina) ...
-
bioRxiv - Molecular Biology 2024Quote: ... RNA was extracted with a Direct-zol RNA MicroPrep Kit and subjected to RNA-Seq library preparation using a Ribo-Zero Gold rRNA Removal Kit (Human/Mouse/Rat) (Illumina) followed by a TruSeq Stranded Total RNA Kit (Illumina).
-
bioRxiv - Microbiology 2024Quote: ... total RNA from mouse gut or human donors was subjected to ribosomal RNA depletion by Ribo-Zero Plus Microbiome rRNA Depletion Kit (Illumina) and cDNA libraries were generated by using Illumina Stranded Total RNA Prep (Illumina ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA was depleted using the RiboZero rRNA Removal Kits for Gram-positive bacteria and/or for human/mouse/rat (Illumina). 300 bp-insert RNA-seq Illumina libraries were constructed using ∼1.0 μg of enriched mRNA that was fragmented then used for synthesis of strand-specific cDNA using the NEBnext Ultra Directional RNA Library Prep Kit (NEB-E7420L) ...
-
bioRxiv - Cancer Biology 2023Quote: ... Hisat2 41–43 was used to align the clean data to mouse reference genome mm10 which we downloaded from Illumina iGenomes database ...
-
bioRxiv - Genomics 2023Quote: ... rRNA was depleted from total RNA using the Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat) (Illumina, San Diego, CA) to enrich for coding RNA and long non-coding RNA ...
-
bioRxiv - Genomics 2023Quote: ... 1 µg RNA was converted to ribosomal depleted cDNA libraries ready for sequencing using the TruSeq Stranded Total RNA Library Prep Human/Mouse/Rat kit (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2023Quote: 1000 ng of bisulfite-treated sperm DNA was loaded onto Illumina Infinium Mouse Methylation-12v1-0 BeadChip (llumina) and was ran on an Illumina iScan System (Illumina) per manufacturer’s standard protocol ...
-
bioRxiv - Molecular Biology 2024Quote: ... The eluted RNAs were ribodepleted by using the rRNA removal section of a TruSeq Stranded Total RNA Library Prep Human/Mouse/Rat kit (Illumina), with the supernatant from the magneticbead separation cleaned up by using a Zymo RNA Clean & Concentrator kit with 8X ethanol ...
-
bioRxiv - Cancer Biology 2021Quote: ... on Thermo Fisher Scientific’s Quantstudio 5 before multiplex pooling and sequencing a 2×100 flow cell on the NovaSeq platform (Illumina) at the Collaborative Sequencing Center.
-
bioRxiv - Genomics 2021Quote: ... Paired-end sequencing (2 × 151 bases) with these purified amplicons was performed using MiSeq (Illumina, San Diego, CA, USA) at Tsukuba i-Laboratory LLP (Tsukuba ...
-
Extensive introgression among North American wild grapes (Vitis) fuels biotic and abiotic adaptationbioRxiv - Evolutionary Biology 2021Quote: ... An RNA-Seq library was prepared using the Illumina TruSeq RNA sample preparation kit v.2 (Illumina, CA, USA) following Illumina’s Low-throughput protocol ...