Labshake search
Citations for GE Life Sciences :
51 - 100 of 134 citations for Cy7 Dyes since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... The excess dye was removed through several PD-10 desalting columns (GE Healthcare). The labeling efficiency was 53.7% according to a UV-Vis measurement ...
-
bioRxiv - Biochemistry 2023Quote: ... Excess dye was removed by SEC on S200 16/600 column (GE Healthcare) equilibrated with buffer C ...
-
bioRxiv - Biophysics 2020Quote: ... Free dyes were removed using a PD-10 desalting column (GE Healthcare Life Sciences). An additional IMAC was performed ...
-
bioRxiv - Biochemistry 2019Quote: ... Unbound dye was removed by PD-10 desalting column (GE Healthcare and Life Sciences) according to the manufacturer’s instructions ...
-
bioRxiv - Biophysics 2021Quote: ... Excess dyes were removed on a PDMiniTrap Sephadex G-25 desalting column (GE Healthcare).
-
bioRxiv - Cell Biology 2021Quote: ... Unbound dye was removed by PD-10 desalting column (GE Healthcare and Life Sciences) according to the manufacturer’s instructions ...
-
bioRxiv - Biophysics 2019Quote: ... Purified σ70 was incubated with Cy5 maleimide mono-reactive dye (1 mM, GE Healthcare) in the storage buffer (50 mM Tris-HCl ...
-
bioRxiv - Neuroscience 2021Quote: ... Myelin was labeled using Amersham CyDye Cy5 Mono-Reactive Dye (GE Healthcare Life Sciences), using half of the recommended dose (1 vial per 2mg myelin) ...
-
Single-molecule FRET probes allosteric effects on protein-translocating pore loops of a AAA+ machinebioRxiv - Biophysics 2023Quote: ... Any unreacted dye molecules were removed on a desalting column (Sephadex G25, GE Healthcare). For the preparation of ClpB hexamers with only one labeled subunit ...
-
bioRxiv - Cell Biology 2024Quote: ... Unconjugated dye was removed by size exclusion chromatography (GE Healthcare, AKTA purifier, Superdex 200). IgG concentration was calculated as:
-
bioRxiv - Cell Biology 2021Quote: ... Excess dye was removed using a PD-10 desalting column (GE Healthcare, Chicago, IL, USA). Titrations were performed in PBS using a constant 1 μM concentration of fluorescein-coupled peptide with increasing concentration of R7R8 fragment (either wild type or vvv mutant) ...
-
bioRxiv - Microbiology 2021Quote: ... The cDNA was labelled individually with both Cy-3 and Cy-5 dyes (GE Healthcare) using Superscript III reverse transcriptase (Invitrogen) ...
-
bioRxiv - Cell Biology 2019Quote: ... After 1 hour the excess dye was removed via PD-10 desalting column (GE Healthcare) equilibrated with the storage buffer (20 mM HEPES ...
-
bioRxiv - Biochemistry 2020Quote: ... Unreacted dye was removed by passing through the PD MidiTrap G-25 column (GE Healthcare) three times ...
-
bioRxiv - Biochemistry 2022Quote: ... EVs were labeled with a Cy3 Mono-Reactive dye pack (GE Healthcare Ltd., Tokyo, Japan) for detection by fluorescence microplate readers (Molecular Devices Japan Ltd. ...
-
bioRxiv - Biophysics 2020Quote: ... followed by the separation of unreacted dye on a desalting column (Sephadex G25, GE Healthcare), buffer-exchange to native buffer (25 mM HEPES ...
-
bioRxiv - Biochemistry 2019Quote: ... and excess free dyes were removed by Sephadex G-25 column (Nap-5, GE Healthcare). Labeling efficiency was estimated by measuring A280 ...
-
bioRxiv - Microbiology 2021Quote: ... the dye values were measured using ImageQuant TL version 8 (GE Healthcare, Chicago, IL, USA) and Adobe Photoshop Elements were normalized to density values per mm2 of a worm’s projection area ...
-
bioRxiv - Cancer Biology 2019Quote: ... then stained with Hoechst 33342 DNA dye and imaged using an INCell Analyzer 3000 (GE Healthcare) or an Opera (Perkin-Elmer ...
-
bioRxiv - Biochemistry 2020Quote: ... The unreacted dye was removed by gel filtration chromatography using Sephadex G-25 resin (GE Healthcare). For GrpE ...
-
bioRxiv - Biochemistry 2023Quote: ... Separation of the labeled protein from residual dye was carried out using a PD10 (GE Healthcare) gel filtration column pre-equilibrated with hSSB2 storage buffer ...
-
bioRxiv - Biophysics 2023Quote: ... Any unbound dye was subsequently removed using a HiPrep™ 26/10 Desalting column (GE Healthcare) connected to an ÄKTA™ FPLC system.
-
bioRxiv - Biochemistry 2024Quote: ... The free dye was separated from labelled protein by a Hi-TRAP Desalting column (GE Healthcare). The final degree of labelling of FtsZ and ZapD was calculated from the molar absorption coefficients of the protein and the dye ...
-
bioRxiv - Microbiology 2021Quote: Cell wall binding assays of recombinant PBP1 proteins fluorescently labelled with Cy2 bis- reactive dye (GE Healthcare) were performed as previously described (Bottomley et al. ...
-
bioRxiv - Microbiology 2019Quote: Fifty micrograms of protein extract from each sample were labeled with Cy3- or Cy5 Dye (GE Healthcare). Labeling was performed reciprocally so that each sample was separately labeled with Cy3 and Cy5 to account for any preferential protein labeling by the CyDyes ...
-
bioRxiv - Biophysics 2021Quote: ... separated from free dye by gel filtration using a PD-10 column (GE Life Sciences, Chicago, IL), and diluted to a working lipid concentration of 144 μM ...
-
bioRxiv - Biophysics 2020Quote: ... The labeled viruses were purified from excess dyes on a Nap-5 gel filtration column (GE Healthcare) that was equilibrated with 50 mM HEPES ...
-
bioRxiv - Biophysics 2022Quote: ... the modified proteins were purified and separated from unbound dye through a gel filtration column (GE Healthcare illustra NAP Columns from Fisher ...
-
bioRxiv - Biophysics 2020Quote: ... the free dyes were removed by centrifugation in MICROSPIN G-50 column (GE Healthcare, 27-5330-01). The labeled proteins were stored at −80°C ...
-
bioRxiv - Biophysics 2021Quote: ... H2A.Z(K120C)-H2B-3xFlag and Swc7 were all cysteine-labeled with maleimide-functionalized Cy3 dye (GE Healthcare) using previously published protocols (53) ...
-
bioRxiv - Microbiology 2022Quote: ... A488-Labelled phage was isolated from free dye by passing over two PD10 desalting columns (GE Healthcare).
-
bioRxiv - Molecular Biology 2021Quote: ... The Fab were separated from unconjugated dye in an equilibrated PD MiniTrap G-25 desalting column (GE Healthcare). Fab were concentrated in an Amicon Ultra-0.5 Centrifugal Filter Unit (NMWL 10 kDa ...
-
bioRxiv - Molecular Biology 2020Quote: ... ChIP and Input samples were labeled with mono-reactive NHS ester fluorescent Cy5 and Cy3 dyes (GE Healthcare) respectively ...
-
bioRxiv - Biophysics 2020Quote: ... excess FluoZin-1 dye was removed by passing the sample through a PD-10 desalting column (GE Healthcare) pre-equilibrated with reconstitution buffer.
-
bioRxiv - Biophysics 2022Quote: ... Labeled proteins were separated from free dye molecules by gel filtration using a Superdex 200 column (GE Healthcare)56.
-
bioRxiv - Biochemistry 2021Quote: ... The excess dye was separated from the labelled protein by SEC (Superdex 75 10/300 GL, GE Healthcare) performed in SEC buffer D (20 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2020Quote: ... uncoupled dyes were separated from labelled antibodies by size exclusion chromatography (on Sephadex G25 PD10 columns GE Healthcare) followed by dialysis against PBS 1x overnight at 4°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... The Fab were separated from unconjugated dye in an equilibrated PD MiniTrap G-25 desalting column (GE Healthcare). Fab were concentrated in an Amicon Ultra-0.5 Centrifugal Filter Unit (NMWL 10 kDa ...
-
bioRxiv - Biophysics 2023Quote: ... The excess dye was removed using a PD-10 Sephadex G-25 desalting column (GE Healthcare, IL, USA), and the buffer was exchanged with ultrapure water ...
-
bioRxiv - Biophysics 2023Quote: ... The excess dye was removed using a PD-10 Sephadex G-25 desalting column (GE Healthcare, IL, USA), and buffer was exchanged for ultrapure water ...
-
bioRxiv - Neuroscience 2021Quote: ... The labeled proteins were separated from the free dyes on a homemade Sephadex G50 resin (GE Healthcare, Piscataway, NJ) column in TBS buffer.
-
bioRxiv - Biochemistry 2021Quote: ... Free dye was removed from labelled MukB by SEC using a Superdex 200 10/300 GL column (GE Healthcare). Labelling efficiency (typically 40-70% ...
-
bioRxiv - Microbiology 2019Quote: LecB was labeled with fluorescent dyes bearing NHS esters as reactive groups (Cy3 mono-reactive NHS ester (GE Healthcare), Cy5 mono-reactive NHS ester (GE Healthcare) ...
-
bioRxiv - Biophysics 2019Quote: ... Free NBD dye was removed by gel filtration using a PD-10 column (GE Healthcare Life Sciences, Marlborough, MA), while labeled and unlabeled peptide were separated by reverse-phase HPLC (Agilent ...
-
bioRxiv - Biochemistry 2021Quote: ... Fractions containing the dye-labelled protein were detected by in-gel fluorescence imaging with an Amersham Typhoon (GE Healthcare) laser scanner.
-
bioRxiv - Biophysics 2019Quote: ... the modified f(Ab)1 fragment was purified and separated from unbound dye through a gel filtration column (GE Healthcare illustra NAP Columns from Fisher ...
-
bioRxiv - Biophysics 2021Quote: ... The dye-labeled protein was purified using a PD-10 column containing Sephadex G-25 Medium (GE Healthcare Life Sciences) and then centrifuged at 50000 rpm for 30 min ...
-
bioRxiv - Molecular Biology 2019Quote: ... unreacted labelling dye was removed via size exclusion chromatography (SEC) on a Superose 6 Increase column (GE Healthcare Life Sciences). All labeled proteins were flash-frozen in liquid nitrogen in the presence of 35% glycerol and stored at −80 °C until usage.
-
bioRxiv - Cell Biology 2019Quote: ... the coating was done with a 2:1 ratio of non-coupled:Cy3-coupled fibronectin prepared with Cy3 Mono-Reactive Dye Pack (GE Healthcare) as recommended by the manufacturer.
-
bioRxiv - Biophysics 2021Quote: ... and in-gel fluorescence of the SecY-conjugated ATTO 643 dye was visualized (Amersham Imager 680RGB, GE Healthcare Life Sciences).