Labshake search
Citations for GE Life Sciences :
4451 - 4500 of 4565 citations for Recombinant Human CD19 protein Fc tagged R PE labeled since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2022Quote: ... High performance liquid chromatography (HPLC) was conducted using a HiTrap Q XL 1 mL Sepharose column on the ÄKTA pure protein purification system (GE Healthcare, Uppsala, Sweden). Proteins were eluted with starting buffer A followed by a gradually increasing concentration of buffer B (20 mM Bis-Tris ...
-
bioRxiv - Microbiology 2022Quote: ... of this fraction was conducted using a 5 mL HiTrap Chelating HP Sepharose column on the ÄKTA FPLC protein purification system (GE Healthcare, Uppsala, Sweden). The proteins were eluted with 10 mL of starting buffer A (native buffer + 10 mM imidazole ...
-
bioRxiv - Microbiology 2022Quote: ... Samples then underwent size exclusion chromatography in an ÄKTA Pure fast protein liquid chromatography (FPLC) using HiLoad 16/600 Superdex 200 or Superdex 75 column (GE Healthcare Life Sciences) in GF-300 buffer (25 mM HEPES buffer at pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: The affinity of the sE protein for the pr peptide was measured by SPR using a Biacore T200 system (GE Healthcare Life Sciences) equilibrated at 25ºC ...
-
bioRxiv - Biochemistry 2023Quote: ... The 5 mL sample concentrated from the fractions involving the target proteins with Amicon Ultra-15 10 kDa was loaded on Resource Q (GE Healthcare Life Science) anion-exchange column equilibrated with buffer A using the FPLC systems ...
-
bioRxiv - Biophysics 2024Quote: ... Germany) and gel filtration fast protein liquid chromatography (FPLC) was performed on a Superdex 75 10/300 GL column (GE Healthcare Life Sciences). The sample was dialyzed against phosphate-buffered saline (PBS ...
-
bioRxiv - Biochemistry 2024Quote: ... Cellular lysates were cleared by centrifugation (14,000 rpm, 20 min) and then incubated (30 min) with Protein G-Sepharose beads (GE Healthcare, Mississauga, ON, Canada) followed by subsequent centrifugation (14,000 rpm ...
-
bioRxiv - Microbiology 2023Quote: ... Lysates were incubated with antibodies for one hour at 4°C in an overhead tumbler before immune complexes were retrieved by protein G (GE Healthcare or abcam) or A Sepharose (GE Healthcare) ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... and anti-mouse-ICAM-1 mAb (clone YN1/1.7.4) were produced by culturing hybridoma cells and purified using protein G sepharose chromatography (GE Healthcare Life Sciences, Pittsburgh, PA).
-
bioRxiv - Cancer Biology 2023Quote: ... 15 μg of the whole protein extracts was separated by SDS gel electrophoresis and transferred to a nitrocellulose membrane (Whatman, GE Healthcare, Freiburg, Germany). Rabbit polyclonal anti-SDHC (1:200 ...
-
bioRxiv - Biochemistry 2023Quote: ... Antibodies were purified from filtered culture supernatants by fast protein liquid chromatography (FPLC) on an ÄKTA Pure instrument using a 1 mL HiTrap MabSelect PrismA column (Cytiva, formerly GE Healthcare Life Sciences). Purified mAbs were concentrated and buffer changed into PBS using Amicon® Ultra-4 50KDa Centrifugal Filter Units (Millipore Sigma) ...
-
bioRxiv - Cell Biology 2023Quote: ... IgG and target specific antibodies (anti-UBAP2L or anti-PLK1) as well as protein G sepharose 4 Fast Flow beads (GE Healthcare Life Sciences) were used ...
-
bioRxiv - Immunology 2023Quote: ... The products were filtered by 10 kDa-cutoff Amicon Ultra centrifugal filters to remove DNA and proteins and then analyzed by a Mono Q 5/50 GL column (GE Healthcare Life Sciences).
-
bioRxiv - Biochemistry 2023Quote: The Exosc3 open reading frame encoding the mouse EXOSC3 protein was cloned into pGEX-6P-2 plasmid (GE Healthcare Life Sciences (now Cytiva)) to create an N-terminally glutathione-S-transferase (GST ...
-
Rhodococcus equi Escapes Macrophage Autophagy: VapA Inhibits ATP6V0d1-Mediated Lysosomal DegradationbioRxiv - Immunology 2023Quote: ... second antibody (1:10000) for 1 h at room temperature and then proteins were visualized with enhance chemiluminescence (ECL) kit purchased from GE Healthcare (Chicago, USA). And detection reagent and analyzed using GE Amersham Imager 600.
-
bioRxiv - Biochemistry 2023Quote: ... Free biotin (or dye) was removed using size-exclusion chromatography by loading the labelled protein on a Superose 6 gel filtration column (GE Healthcare, Pittsburgh, PA) eluted with 20 mM HEPES pH 7.5 ...
-
bioRxiv - Molecular Biology 2023Quote: ... and immuno-reactive protein bands were detected by the ECL system and visualized by imaging analyzer (ImageQuant LAS 500, GE Healthcare Life Sciences).
-
bioRxiv - Neuroscience 2023Quote: ... Then 60 μg of the total protein of each genotype was separated on 8% SDS-PAGE and transferred to the PVDF membrane (Amersham, GE Healthcare Life Sciences). The membrane was blocked in 5% skimmed milk (HIMEDIA ...
-
Evolutionary Adaptation of an HP1-protein Chromodomain Integrates Chromatin and DNA Sequence SignalsbioRxiv - Genetics 2024Quote: ... The protein was further purified using tandem ion exchange chromatography with HiTrap Q HP and HiTrap SP HP columns (Cytiva/GE Healthcare Life Sciences). Digested protein was first diluted three-fold with low salt buffer (20 mM Tris ...
-
bioRxiv - Cell Biology 2024Quote: ... for 1 h at 4°C on a rocker followed by an incubation with 200 μl of a 20 % slurry of protein A sepharose beads (GE Healthcare, Uppsala, Sweden) for 1 h at 4°C ...
-
bioRxiv - Plant Biology 2024Quote: ... The proteins were separated on SDS-PAGE and fluorescently labelled proteins were detected by in-gel scanning with the Typhoon FLA 9000 (GE Healthcare Life Sciences) using Cy3 settings (532nm excitation and 610PB filter).
-
bioRxiv - Biochemistry 2024Quote: ... Free biotin was removed using size-exclusion chromatography by loading the labelled protein on a Superose 6 gel filtration column (GE Healthcare, Pittsburgh, PA) eluted with 20 mM HEPES pH 7.5 ...
-
bioRxiv - Molecular Biology 2024Quote: ... University of Pennsylvania School of Medicine) [61] and HuR (19F12, Thermo) 400 μL of 10% (v/v) protein A Sepharose CL-4B beads (GE Healthcare Life Sciences) in IP-2 buffer [50 Mm Tris pH 7.9 ...
-
bioRxiv - Cell Biology 2020Quote: ... Whole cell lysates were subjected to SDS–PAGE and protein expression was visualized using an enhanced chemiluminescence detection system (GE Healthcare, Little Chalfont, UK) as described before[30] ...
-
bioRxiv - Immunology 2021Quote: ... The Fc and IdeS A were removed using a mix of Protein A Sepharose® Fast Flow (250 µL per 1 mg digested mAb; GE Healthcare Life Sciences) and Ni Sepharose™ 6 Fast Flow (50 µL per 1 mg digested mAb ...
-
bioRxiv - Microbiology 2021Quote: ... Proteins were separated in standard procedures using 12% polyacrylamide gel (SDS-PAGE) and transferred to polyvinylidene fluoride (PVDF) membranes (GE Healthcare Life science, Germany) using TransBlot semi dry transfer cell (Bio-Rad ...
-
bioRxiv - Immunology 2022Quote: ... 50 mM imidazole) before eluting the protein (HBS, 250 mM imidazole) following desalting using a HiPrep™ 26/10 Desalting column (GE Healthcare, Diegem, Belgium) to remove imidazole ...
-
bioRxiv - Molecular Biology 2021Quote: ... 300 µg of the prepared lysate was incubated with the appropriate antibody (3 µg) and pulled down using protein A Sepharose 6MB (GE healthcare # 17-0469-01). All primary antibodies used in this study are listed in table T3 ...
-
bioRxiv - Neuroscience 2019Quote: ... Equivalent amounts of protein or equal volume from each sample were run on SDS-polyacrylamide gels and transferred to polyvinylidene difluoride membranes (GE Healthcare, Piscataway, NJ, USA). Following blocking in 5% milk or bovine serum albumin the blots were incubated with primary antibodies and analyzed by HRP-conjugated secondary antibodies (Jackson Laboratories) ...
-
bioRxiv - Pathology 2019Quote: ... Immunoreactive bands were detected by a FluorChem FC3 System (Protein-Simple, San Jose, CA, USA) after incubation of the membranes with ECL Selected Western Blotting Detection Reagent (GE Healthcare, Pittsburgh, PA, USA). Densitometric analyses of the immunoreactive bands were performed by the FluorChem FC3 Analysis Software.
-
bioRxiv - Microbiology 2019Quote: ... 75-90 μl of affinity-purified protein sample was loaded onto a Superdex 200 Increase 10/300 GL SEC column (GE Healthcare, Chicago, IL, USA) previously equilibrated with 20 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2019Quote: ... using a HiTrap NHS-Activated HP affinity column coupled with aIL-4 monoclonal antibodies and an ÄKTA Fast Protein Liquid Chromatography (FPLC) instrument (GE Healthcare, Piscataway, NJ, USA). Immunizations ...
-
bioRxiv - Biochemistry 2019Quote: ... The reacting agents were then separated from the now methylated proteins by size-exclusion chromatography using NapTM-5 columns according to the manufacturer’s instructions (GE Healthcare Life Sciences, Amersham, UK).
-
bioRxiv - Immunology 2020Quote: Approximately 200 μL of normal mouse serum or anti-CD200 serum day 157 (after 4X immunizations) were purified using a protein G SpinTrap (GE Healthcare # 28-4083-47) according to the manufacturer’s instrutions ...
-
bioRxiv - Cell Biology 2019Quote: ... Protein eluates were further resolved using size exclusion chromatography on gel filtration columns using the Superdex 200 (16/600) (GE Healthcare, GE28-9893-35) or Superdex 75 (16/600 ...
-
bioRxiv - Cell Biology 2021Quote: ... Gels were incubated in Bjerrum Schafer-Nielsen transfer buffer and proteins were transferred to a water-activated nitrocellulose membranes (Amersham Protran Premium 0.45 NC, GE Healthcare Life Sciences, Sunnyvale, USA) using semi-dry transfer (Trans-Blot® Turbo™ ...
-
bioRxiv - Cell Biology 2020Quote: ... Gels were incubated in Bjerrum Schafer-Nielsen transfer buffer and proteins were transferred to a water-activated nitrocellulose membranes (Amersham Protran Premium 0.45 NC, GE Healthcare Life Sciences, Sunnyvale, USA) using semi-dry transfer (Trans-Blot® Turbo™ ...
-
bioRxiv - Biochemistry 2021Quote: ... The eluted protein was further purified by size-exclusion chromatography (SEC) using a sizeexclusion column (Superose 6 increase 10/300 GL; GE Healthcare, U. S. A.) in TN buffer (50 mM Tris-HCl (pH 7.6) ...
-
bioRxiv - Biochemistry 2021Quote: Nickel Immobilised Metal Ion Affinity chromatography (Ni2+-IMAC) for protein purification was conducted using a HisTrap® HP 5 mL column (GE Healthcare, Munich, Germany) coupled to a BioLogic DuoFlow™ Chromatography System (Bio-Rad ...
-
bioRxiv - Biophysics 2021Quote: ... The SΔTM protein was then further purified by size exclusion chromatography on a Superdex 200 Increase 10/300 GL column (GE Healthcare, Chicago, IL, USA) (Fig ...
-
bioRxiv - Biophysics 2021Quote: ... The eluted S proteins were further purified by size-exclusion chromatography (SEC) using a Superose 6 increase 10/300 GL column (GE Healthcare, U. S. A.) in TBS buffer (50 mM Tris-HCl (pH 7.6) ...
-
bioRxiv - Cell Biology 2021Quote: ... 15-25 μg of total protein per sample were resolved on 8%-14% SDS-PAGE and transferred onto nitrocellulose membrane (Amersham Hybond, GE Healthcare Life Science, 10600002). Membranes were blocked in 5% milk in PBS followed by incubation with specific primary and secondary antibodies ...
-
bioRxiv - Plant Biology 2021Quote: ... Protein was separated on the 10 % SDS PAGE and transferred on the polyvinylidene difluoride (PVDF) membranes (Hybond™-P; GE Healthcare, Piscataway, NJ, USA) using the wet transfer method (1 hour ...
-
bioRxiv - Cell Biology 2022Quote: ... Following electrophoresis, protein was transferred onto a 0.45 μm nitrocellulose (Amersham Protran Premium, 10600096) or a PVDF membrane (GE Healthcare Amersham Hybond ECL, RPN68D). 0.4% PFA was used to fix the protein on the membrane ...
-
bioRxiv - Biophysics 2021Quote: ... Amplified phage particles at 10-fold dilution were assayed against 20 nM biotinylated membrane proteins in nanodiscs using horse radish peroxidase (HRP)-conjugated anti-M13 monoclonal antibody (GE Healthcare, #27-9421-01). Assays were performed in library sorting buffer (200 mM NaCl ...
-
bioRxiv - Cell Biology 2022Quote: ... the remainders of the lysates were nutated with anti-Cdc15 polyclonal antibody (VU326) (Roberts-Galbraith et al., 2009) for 1 hr at 4°C followed by incubation with protein A sepharose (GE Healthcare; 17-5280-04) for 30 min at 4°C ...
-
bioRxiv - Pathology 2019Quote: ... Equal amounts of protein extracts (25 µg) were separated by SDS-PAGE before electrophoretic transfer onto a nitrocellulose membrane (GE Healthcare, Velizy-Villacoublay, France). Western-blot analysis was carried out using anti-LC3-II (1:1000 ...
-
bioRxiv - Molecular Biology 2019Quote: ... Proteins were transferred to nitrocellulose membranes and visualized by enhanced chemiluminescence using ECL Prime Western Blotting Detection Reagent (#RPN2232, GE Healthcare; Chicago, IL, USA) and imager ImageQuant LAS 4000 (GE Healthcare ...
-
bioRxiv - Synthetic Biology 2019Quote: ... A Bio-Rad ChemiDoc XRS imaging system was used for visualizing the protein blot after incubations with ECL plus reagent (GE Healthcare, catalog no. RPN2132).
-
bioRxiv - Molecular Biology 2020Quote: ... Immunoprecipitation procedures were performed by mixing ~1.6 mg of total proteins and 30 μl of the IgG Sepharose 6 Fast Flow beads (GE Healthcare, Cat# 17-0969-01) at 4°C for 2h and precipitating the NTAP tagged Orc4 ...