Labshake search
Citations for GE Life Sciences :
401 - 450 of 673 citations for SARS Coronavirus Nucleoprotein NP His tag HEK293 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2019Quote: Removal of the His6-tag (Rab8a) was performed by overnight incubation at 4 °C with thrombin (GE Healthcare), followed by a second Ni2+-agarose column ...
-
bioRxiv - Cell Biology 2020Quote: ... Scd1 (aa 10-872) and Rga4 (aa 389-1150) were cloned into pGEX6P1 (GST tag) vector (GE Healthcare), expressed in BL21 (DE3 or Rosetta ...
-
bioRxiv - Cancer Biology 2019Quote: ... The resulting tag-cleaved proteins were purified by ion exchange chromatography with a HiTrap SP column (GE Healthcare) and gel filtration with the final buffer (25 mM Tris-HCl buffer at pH 7.0 ...
-
bioRxiv - Biochemistry 2021Quote: ... His6-tag free Ape1 protein was then loaded onto a Superdex 200 10/300 GL column (GE Healthcare) in 20 mM Tris-HCl pH 7.0 ...
-
bioRxiv - Biochemistry 2022Quote: ... The tag cleaved Ub was further purified by size exclusion chromatography through a Superdex 75 column (GE Healthcare) in buffer A.
-
bioRxiv - Immunology 2023Quote: Human ACE2 with Fc tag was immobilized onto Protein A sensor chips using a Biacore 8K (GE Healthcare). Purified SARS-CoV-2 mutants RBD were prepared in serial dilutions ...
-
bioRxiv - Immunology 2022Quote: ... and HEK293 cell lines were obtained from Royan Institute Cell Bank and cultured in Dulbecco’s Modified Eagle Medium (DMEM, GE Healthcare Life Sciences, Pittsburgh, PA, USA) supplemented with 10% heat-inactivated fetal bovine serum (FBS ...
-
bioRxiv - Microbiology 2020Quote: ... The IgG anti-SARS-CoV-2 was purified from plasma of a convalescent patient using a 5/5 HiTrap rProtein-A column (GE Healthcare, USA). See detailed information about this procedure in Supplementary method No.1.
-
bioRxiv - Genetics 2021Quote: SARS-CoV-2 receptor binding domain binding to human extracellular ACE2 were analysed on a Biacore T200 instrument (GE Healthcare Life Sciences) at 37°C and a flow rate of 30 μl/min ...
-
bioRxiv - Immunology 2020Quote: SEC-purified SARS-CoV-2 RBD-SD1 was immobilized to a Ni-NTA sensor chip in a Biacore X100 (GE Life Sciences) to a response level of ~500 RUs ...
-
bioRxiv - Immunology 2019Quote: ... All His-tagged proteins were purified from the cell culture medium using HisTrap Excel column (GE Healthcare, catalog 17371206) and eluted using buffer containing 50 mM HEPES-NaOH ...
-
bioRxiv - Cell Biology 2019Quote: ... The supernatant was loaded at 1 ml/min on a His-Trap FF-crude 5 mL column (GE Healthcare) equilibrated with PBS buffer ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Quality control of A33-His was performed by SDS-PAGE and size exclusion chromatography (Superdex75 10/300GL, GE Healthcare). The protein was digested with PNGase F (New England BioLabs ...
-
bioRxiv - Biochemistry 2020Quote: ... Enc:EncFtn protein complex sample was loaded onto a 20 ml anion exchange column (Hi-Prep Q HP, GE Healthcare) pre-equilibrated with Buffer QA (50 mM Tris ...
-
bioRxiv - Biochemistry 2021Quote: The filtered lysates were subjected to IMAC using a His-Trap 5 mL Nickel column (GE Healthcare Life Sciences) on an ÄKTA Pure system (GE Healthcare Life Sciences) ...
-
bioRxiv - Microbiology 2021Quote: ... and the resulting soluble fraction was applied on a Ni-NTA column (GE Healthcare, His Trap FF 1 ml) and purified according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... The His-tagged GlpQ protein was purified by Ni2+-affinity chromatography using a 1 ml HisTrap column (GE Healthcare) followed by size exclusion chromatography on a HiLoad 16/60 Superdex 200 pg column (GE Healthcare ...
-
bioRxiv - Biophysics 2022Quote: ... The mixture was incubated at 10°C for 3h and then loaded onto a His Spintrap column (GE Healthcare). After 1-hour incubation ...
-
bioRxiv - Neuroscience 2019Quote: ... Samples were filtered (0.45 μm) to remove residual cellular debris and loaded onto a His-Trap Column (GE Healthcare) at 4°C ...
-
bioRxiv - Biochemistry 2020Quote: ... The concentrated sample was further purified over a Superdex 200 Hi-load 16/60 gel filtration column (GE Healthcare) pre-equilibrated with 20 mM potassium phosphate (pH 7.4) ...
-
bioRxiv - Biophysics 2019Quote: ... The eluted proteins from Ni-NTA column were loaded onto a Hi-load 16/60 Superdex 200 (GE Healthcare) gel filtration column pre-equilibrated with 25mM Tris pH 8.0 ...
-
bioRxiv - Biochemistry 2021Quote: The interaction between PttP1 and PttP2 was studied by a pulldown assay using His SpinTrap™ columns (GE Healthcare) with a bed volume of 200 μl ...
-
bioRxiv - Microbiology 2021Quote: ... The proteins were further purified by Ni-NTA immobilized metal-affinity chromatography using His-Trap HP columns (GE Healthcare) followed by size exclusion chromatography ...
-
bioRxiv - Microbiology 2022Quote: ... and loaded to a Hi-Load 16/600 Superdex-200 pg (preparation grade) size-exclusion chromatography column (GE Healthcare) equilibrated with the gel filtration buffer (100 mM NaCl ...
-
bioRxiv - Immunology 2023Quote: ... Protein TLR827–827-PA-His was purified with IgG beads (Cat#17-0969-01, GE Healthcare, Connecticut, CT, USA) and resuspended in 200 μl of NT2 buffer 66 and used for miRNA-protein co-IP ...
-
bioRxiv - Biochemistry 2023Quote: ... most of the proteins were loaded onto a Hi-trap Q HP anion exchange column (GE Healthcare, cat. 17115401). The final purification step involved using a size exclusion column ...
-
bioRxiv - Molecular Biology 2024Quote: ... The soluble extract was loaded onto the Hi-Trap Chelating HP 1 ml pre-packed column (GE Healthcare/Cytiva) pre-equilibrated with buffer A containing 500 mM NaCl ...
-
bioRxiv - Microbiology 2024Quote: ... His-2xFYVE-containing fractions were pooled and subjected to size exclusion chromatography using a Superdex 75 column (GE HealthCare). Finally ...
-
bioRxiv - Biochemistry 2024Quote: ... All purification steps were performed at 4°C and the pre-packed amylose column (5ml Hi-Trap GE healthcare) was equilibrated with 25 mL Amylose column A Buffer ...
-
bioRxiv - Biochemistry 2024Quote: Native and selenomethionine-substituted BT4246 proteins were purified using a 5 ml Hi-Trap metal affinity cartridge (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2021Quote: Tag-free syndapin I and III were generated by expressing both proteins in the pGEX-6P vector (GE Healthcare) and cutting of the GST tag from purified proteins using PreScission protease (GE Healthcare ...
-
bioRxiv - Biochemistry 2021Quote: ... The GST-tag and Thrombin protease were removed via heparin affinity chromatography (HiTrap Heparin 5 ml FF, GE Healthcare). Cas12a was eluted via an elution gradient with 1 M NaCl (20 mM Tris/HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2021Quote: ... The GST tag was removed by overnight cleavage at 4 °C using GST fusion 3C protease (Prescission, GE Healthcare). Fusion protease was removed using glutathione resin and the cleaved β2HA was collected in the flow-through ...
-
bioRxiv - Biochemistry 2023Quote: ... Various Prp40 domains fused with an N-terminal Flag tag were cloned into pGEX-6p-1 vector (GE Healthcare) and purified from E.coli as GST fusion proteins ...
-
bioRxiv - Biochemistry 2021Quote: ... of L-enantiomeric peptides CDP1 and CDP7 binding to SARS-CoV-2 3CLpro was determined by Surface Plasmon Resonance Spectroscopy (SPR) using a Biacore 8K instrument (GE Healthcare, Uppsala, Sweden). The peptides were immobilised on two separate channels on a series S CM-5 sensor chip (Cytiva ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant obtained by centrifugation (19,000 × g, 15 min, 4°C) was applied to a His SpinTrap column (GE Healthcare) previously equilibrated with buffer A ...
-
bioRxiv - Biochemistry 2021Quote: ... Both untagged and His-tagged Impβ were further purified using a Superdex 200 16/60 gel filtration column (GE Healthcare) in 50 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2020Quote: ... The cell lysate was then centrifuged at 18,800 × g for 10 min and the resulting supernatant was applied to His Spin Trap (GE Healthcare). After centrifugation (100 × g ...
-
bioRxiv - Biophysics 2019Quote: ... The bacterial lysate was clarified using centrifugation at 20,000 x g for 40 min and loaded onto a 5 ml His-Trap column (GE Healthcare) pre-equilibrated with lysis buffer ...
-
bioRxiv - Microbiology 2019Quote: ... The recovered supernatant was filtered using 0.45 μm syringe-driven filters (Jet Biofil) and loaded in a His-Trap column (GE Healthcare) equilibrated with 350 mM NaCl ...
-
bioRxiv - Cell Biology 2019Quote: ... The sample was concentrated on an Amicon Ultra Centrifugal Filter Unit (10 kDa cut-off) and injected at 0.5 ml/min on a Hi-Load 16/60 Superdex column (GE healthcare), equilibrated with 20 mM Tris-HCl buffer ...
-
bioRxiv - Cancer Biology 2019Quote: ... the lysate spun down at 12,000 x g for 30 min and then loaded onto a 5 ml His-Trap Crude FF column (GE Healthcare) using a ÄKTA Purifier protein purification system (GE Healthcare) ...
-
bioRxiv - Microbiology 2021Quote: ... The resulting lysate was centrifuged for 30 minutes at 20,000 rpm to remove cell debris and the supernatant was filtered with a 0.45 μm filter before loading onto an equilibrated 5 ml His Trap HP column (GE healthcare) connected to an ÄKTA pure 25 system ...
-
bioRxiv - Biochemistry 2021Quote: ... XLF-6xHis was purified using a HP His-trap column followed by a HiTrap Q HP column (both GE Healthcare). mSUMO1 (#UL-712) ...
-
bioRxiv - Systems Biology 2021Quote: ... The supernatants obtained after this step were loaded in 5-mL His-trap columns (GE Healthcare Systems, Chicago, IL, USA) pre-equilibrated with buffer A supplemented with 100 mM NaCl and 20 mM imidazole ...
-
bioRxiv - Microbiology 2021Quote: ... the obtained supernatants were filtered through sterile PVDF filters (pore size 0.22 μm) and loaded on 1 ml His-Trap columns (GE Healthcare), pre-equilibrated with ten column volumes of each Millipore water and sodium phosphate buffer A ...
-
bioRxiv - Microbiology 2020Quote: ... His-CD147 (produced by our laboratory) was fixed to the surface of CM5 sensor chips (GE Healthcare Bio-Sciences AB) by amino coupling kit (GE Healthcare ...
-
bioRxiv - Cell Biology 2021Quote: ... His-Bro1ΔAPRR purified from BL21-DE3 using Ni2+-affinity chromatography (5 ml HiTrap Chelating FF column; GE Healthcare, United Kingdom). GST-Bro1V(370-709 ...
-
bioRxiv - Immunology 2021Quote: ... His-CyPA (produced by our laboratory) was fixed to the surface of CM5 sensor chips (GE Healthcare Bio-Sciences AB) by an Amine Coupling Kit (GE Healthcare ...
-
bioRxiv - Cell Biology 2021Quote: ... Insoluble material was sedimented by centrifugation at 13,500 g for 30 min at 4°C prior to loading on His-trap FF columns (GE Healthcare) pre-equilibrated with lysis buffer ...